Pentair SOLEO CL Installation And User Manual

SOLEO® CL
SB-PF-SOL-004C
®
CHLORINE
SOLEO
FILTRATION, PH & ORP
15:15 Water:+28.4°C Filtration : ON Chlorine : 1.31mg/L Air:+27.9°C pH: 7.3
ESC
VALID
INSTALLATION AND USER GUIDE
IMPORTANT SAFETY INSTRUCTIONS, READ AND FOLLOW ALL OF THE INSTRUCTIONS, KEEP THESE INSTRUCTIONS
PENTAIR WATER SOLUTIONS SB-CU-IMP-056C (Rev. 03/2019)
EN
Pentair thanks you for placing your trust in the company and purchasing a SOLEO®, the control automation system for essential swimming pool equipment. SOLEO® Chlore will automatically control your pool locally.
Please carefully read this user manual to fully benet from all of the functions of SOLEO® Chlore. Store it carefully so that it can be consulted at
any time.
Declaration of conformity
Directives – Harmonised standards
Pentair International Sarl - Avenue de Sévelin 18 - 1004 Lausanne - Switzerland
We declare, under our own responsibility, that the product meets the directives
SAFETY EN 61010-1:2010
EMC EN 61326-1: EN 301 489-3 EMF EN 62311 RADIO EN 300 220-2
SOLEO CHLORE (+ PARTS)
SB-PF-SOL-004C
Other normative documents
PART NUMBERS:
SB-SE-SOL-002B
Authorised person for technical documentation
Pentair International S.a.r.l Avenue de Sévelin 18 1004 Lausanne - Switzerland
Lausanne, 01/04/2019
Guillaume Goussé
European Vice President of Operations
Product specications: SB-PF-SOL-004C model Operating temperature: 0° to 40° C Operating hygrometry: 40% at 75° C Power supply: 230 V ~, 50 Hz Maximum operating altitude: 2,000 m Weight (excluding probes): 1.2 kg Main box (internal use): IP 64
Waste treatment of electronic devices at the end of their service life:
The crossed-out bin placed on the main parts which make up the product indicates that it must not be disposed of together with the household waste. It must be returned to an appropriate collection point for electronic device recycling (information available from the local household waste collection service). This product contains potentially dangerous substances which may have adverse effects on the environment and human health.
Customer Support: PISA, ITALY (8:30 A.M. to 4:30 P.M.) CET website: www.pentairpooleurope.com
- Warranty (excluding probes and consumables): 2 years
© 2019 Pentair International LLC, All rights reserved - The document is subject to change without notice
Trademarks and disclaimers: Soleo® and Pentair® are trademarks and/or registered trademarks of Pentair and/or its aliated companies. Unless indicated otherwise, names and brands of others that may be used in this document are not used to indicate an aliation or endorsement
between the owners of these names and brands and Pentair. Those names and brands may be the trademarks or the registered trademarks of these parties, or others.
Summary
PRESENTATION
> Safety instructions
> Content of packaging
> Description, general operation and functions of the device
INSTALLATION - SPECIFIC POINTS
> Installation organisation
> Mounting
> Electrical installation
> Water and air temperature sensors
> Connecting the probes
> Calibration of the chlorine probe and general points on chlorine
> Filtration - connections and settings
> Filtration - Expert menu
> Assisted backwash: Support for lter backwash.
> Connection of a ow rate detector and use of RedOx
> pH pump - connections and settings
> Menu for calibration and maintenance of the probes
> Radio menu (peering)
> Time Set menu, Information menu, Languages menu and History menu
p 03
p 04
p 05
p 07
p 08
p 09
p 10
p 11
p 12
p 13
p 14
p 15
p 16
p 17
p 19
p 19
p 20
OTHERS
> Navigation menus
> Assembling pH and ORP probes
> Updating internal rmware
> pH / RedOx / chlorine ratio
p 21
p 23
p 24
p 25
01
IMPORTANT SAFETY GUIDELINES, READ AND FOLLOW ALL OF THE INSTRUCTIONS, KEEP THESE INSTRUCTIONS
GENERAL POINTS
- DANGER - INSTALLERS, POOL SPECIALISTS AND OWNERS MUST CAREFULLY READ THESE WARNINGS AND ALL INSTRUCTIONS BEFORE USING THIS PRODUCT.
- WARNING - Most countries regulate the construction, installation and operation of public swimming pools and spas, and the construction of residential pools and spas. It is important to comply with these regulations, many of which directly regulate the installation and use of this product. Consult your local building and health codes for more information.
- WARNING - This installation and user guide contains important information on the installation, operation and safety of this product. This guide should be provided to the owner and/or user of this product.
INSTALLATION
- DANGER - RISK OF ELECTRIC SHOCK or electrocution
- BEFORE WORKING ON THIS DEVICE - Always cut the supply to the device at the circuit breaker before maintenance. Failure to do this may lead to
death or serious injury to service staff, pool users or others, due to an electric shock.
- DANGER - SERIOUS BODILY INJURY OR DEATH CAN RESULT IF THIS PRODUCT IS NOT INSTALLED AND USED CORRECTLY.
- WARNING - Before installing this product, read and follow the warnings and instructions of this guide. Failing to follow these warnings and
instructions may lead to serious injuries, death or material damage. Refer to www.pentairpooleurope.com for more information linked to this product.
- WARNING - Connect the device to a differential interrupter. If this system is used to control the underwater lighting devices, a differential interrupter must be installed upstream of these devices. Conductors downstream of the differential interrupter shall not be located in ducts, junction boxes or enclosures containing other conductors, except if the conductors are also protected by a differential interrupter. Refer to valid local codes for more details.
- WARNING - This product must be installed by an authorised or certied electrician or a qualied swimming pool professional. All of the applicable
installation codes and local regulations must also be respected. Poor installation will create an electrical hazard which could result in serious injury or the death of pool users, installers or others due to electric shocks, and may also cause damage to property.
- DANGER - DISCONNECT THE POWER SUPPLY CONNECTIONS BEFORE WORKING ON THIS DEVICE; ELECTRICAL POWER MAY BE SUPPLIED TO THE RELAY TERMINALS FROM OTHER SOURCES.
- WARNING – CHEMICAL BURN HAZARD: Make sure all pumps are switched off at the main circuit breakers at the domestic distribution board before
drilling into any pipes. Set rules for all handling related to electrical aspects, water and chemical products. Group the supply pumps and chemical
product tanks in a safe and secured area.
- WARNING - Do not use this product to control an automatic swimming pool cover. There is a risk that swimmers could become trapped under the cover.
- WARNING – Devices which are not intended for use in single-family dwellings may require additional safety equipment to comply with local regulations.
- WARNING – Except for remote controls, install components at a minimum of at least 1.5 m (5 feet) from the inside wall of the pool or spa.
- WARNING - This product is intended for use in swimming pool applications only.
- WARNING - A sucient equipotential connection (min. 4.5 mm2 recommended), in accordance with local regulations, is obligatory for all metal
components of the swimming pool, including the pool pump. This is necessary for the electrical safety as well as reduction of the corrosion risk.
02
USE
- DANGER - DO NOT LET CHILDREN OPERATE THIS EQUIPMENT.
- WARNING – Strictly respect the safety and handling procedures from the acid manufacturers, including protective measures for hands, body and
eyes during transfer and use of acid. Follow the prescribed safety precautions for handling muriatic acid intended for checking the water pH. Muriatic acid may cause serious physical harm and may damage the swimming pool equipment. Extra care must be taken when installing, maintaining and operating the acid pump feed systems. Acid is dangerous to handle and should be properly contained, transported, poured, stored and dispensed.
- WARNING – Check the pH and sanitizer levels of the water before using the pool and make sure the ltration device is not obstructed.
- WARNING – Periodically use an independent pH and chlorine testing kit to ensure that the pH and chlorine is at a safe level. If the pH and Oxidation
Reduction Potential (ORP) or conductivity probes are broken, depleted or dirty with oils, lotions, or other contaminants, they can report inaccurate results to the system causing incorrect water chemistry, which could harm people or equipment.
- WARNING – Consult the device display daily to ensure there are no alarm messages.
- DANGER – Water temperatures greater than 37.7° C (100° F) are a health hazard. Prolonged immersion in hot water may induce hyperthermia.
Hyperthermia occurs when the internal body temperature exceeds the normal temperature of 37° C (98.6 °F) by several degrees. Hyperthermia may
produce the following effects: (1) Unawareness of impending danger. (2) Failure to perceive heat. (3) Failure to recognise the need to leave the spa. (4) Physical inability to leave the spa. (5) Harm to the foetus in pregnant women. (6) Unconsciousness leading to the risk of drowning. The use of
alcohol, drugs or medicine is a factor which increases the risk of hyperthermia in hot tubs and spas.
- WARNING - When mixing acid with water, ALWAYS ADD THE ACID TO THE WATER. Never add water to the acid. When adding a chemical product to the swimming pool, carefully follow the manufacturer instructions.
- DANGER - DO NOT MIX SODIUM HYPOCHLORITE AND MURIATIC ACID.
- DANGER - Keep standard solutions away from children, ensure that the bottles are securely closed, store them in a dry and ventilated location and
do not let them freeze. The pH 4 calibration solution is acidic.
03
Contents of the box and description
Screen
(4 x 20 characters)
Menu navigation buttons
(Esc/Bottom/Top/Valid.)
Status light
(for updates)
Manufacturer tag
S/N 1234ABCD1234ABCD1234ABCD01
230 V 50 Hz~/IP64/3.2 W
433.4 MHz
Serial number
MADE IN ITALY
Mfg Year
SCAN ME
Apr-2019
SB-PF-SOL-004C SB-SE-SOL-002B
QC Passed
Pentair International Sarl Avenue de Sévelin 18 CH-1004 Lausanne, Switzerland
Fuse holder (1 A 250 VAC)
Connector cover
(Removable with a at screwdriver)
Screw cover
(Insulator of acidic vapours
and humidity circulating
via the screw hole)
Soft cover
(Insulator of acidic vapours
and humidity)
Place the soft cover back in its original position each time you have opened the device.
4 7
FRONT VIEW
SOLEO
FILTRATION, PH & ORP
15:15 Water:+28.4°C Filtration : ON Chlorine : 1.31mg/L Air:+27.9°C pH: 7.3
ESC
pH4 and pH7 calibration solutions
Necessary for calibrating the pH probe
The pH4 solution is acidic
®
CHLORINE
VALID
Water temperature sensor
(For air as an option)
pH probe (optional)
RedOx probe (optional)
with (with screw above) = probe out of the water
pH/ORP probe canister
without = probe in the water
The probe bottles are lled with potassium
chloride. !!! DO NOT DRINK!
Tighten/loosen the probe bottles.
pH
ORP
USB / mini USB
Update of the software
Never push or pull on the tted probe bottles.
Clamp band
For mounting the water temperature probe
CABLE GLANDS x 2
Screw thread: 1/2 inch
The 2 cable glands are compatible with 1/2’’ threading for assembly on a bypass. However Pentair advises installing the pH and RedOx probes in a probe holder.
04
Description
SOLEO CL is the brain of the system. SOLEO calculates automatically and controls the operating time of each piece of the equipment.
- Access to information in the technical room:
- SOLEO CL supplies the information on a backlit display.
- Control of the equipment in the technical room:
SOLEO CL supplies the dry contacts to which the classic equipment of the technical room is connected
(ltration pump, disinfectant [electrolyser, dosing pump], pH pump).
Please do not use the individual automations of the equipment. SOLEO CL will start/stop the devices.
If SOLEO CL is linked to a SPEEDEO, the activation duration of the lter is managed by SOLEO CL, while the
VS pump speeds are managed by SPEEDEO (depending on the events).
- Receiving and processing information:
The probes supply the information required for regulating SOLEO CL; indeed, at the end of a dosing (disinfection, addition of a pH regulator), the probes send a value which makes it possible for SOLEO CL to
rene its settings.
Functions
Filtration control:
- By calculating the time according to the pool temperature (automatic mode).
- By programming a 24 hour cycle (makes it possible to benet from off hours).
- By integrating the frost protection function (activation of the ltration below 3°C, modiable value).
- Possibility to select the start time and end time of the ltration in automatic mode (to prevent noise at night).
- Possibility to increase or reduce the ltration time according to the use of the swimming pool (economical
mode = pool with a low number of visitors, turbo mode = pool with a high number of visitors) or by default + or
- 30% (value can be adjusted).
- Possibility to change into “SHOCK” mode (forcing of the ltration and electrolyser for 24 hours).
Control of a disinfectant dosing pump or brominator:
- By integrating the information supplied through the amperometric probe.
Control of a pH pump:
- By integrating the information supplied through the pH probe.
SOLEO CL also makes it possible to visualise, on its screen (in the technical room):
- The instant pool information (free chlorine level, water level [pH + RedOx as options]).
- The functioning durations of the ltration and disinfection from the current day (since midnight) and from
the previous day.
- The functioning durations of the ltration and disinfection from the previous day (full 24 hours).
Therefore, in summer and winter, you no longer need to worry about your ltration and you limit the interven-
tions in the technical room to a bare minimum.
05
Installation organisation
However installing the probes in a bypass is advised (SB-PD-PRO-005B) which slightly optimises the quality of the measurement and the service life of the probes. The installation of the chlorine probe holder is described
in its own operating instructions. To prevent the probe holder being obstructed, installing a pre-lter
upstream is necessary. However SOLEO CL is supplied with 2 probe holders intended for clamp saddles, ensuring quick installation.
®
CHLORINE
SOLEO
FILTRATION, PH & ORP
15:15 Water:+28.4°C Filtration : ON Chlorine: 13.1mg/L Air:+27.9°C pH: 7.3
ESC
VALID
- The probe cables must not cross the power cable in the channel.
- Sampling faucet
- Installing a pre-lter
before the probe holder is necessary (not supplied).
- The hydraulic network must be linked to the earth to prevent the precision of the probes being altered.
!!!!!!!!!!!!!!!!!!!! ! No analysis ! ! chamber ow ! !!!!!!!!!!!!!!!!!!!!
- Amperometric chlorine probe (not supplied).
50 cm max.
ORP
pH
- Flow switch of the sensor bowl (not supplied).
- The probes must be placed
after ltration and before
the disinfection and heating pump.
- Limit the ow to ll the bowl (0.5L) in 1 minute.
The flow-switch of the amperometric chlorine probe detects an absence of flow. The chlorine regulation is disabled. Check the correct operation of the hydraulic equipment.
06
General diagram (without Speedeo)
®
CHLORINE
SOLEO
FILTRATION, PH & ORP
28/04/2017 15:23:48 Water temp. :+29.0°C pH:7.8 ORP: 607mV Cond:5264uS 3.28 g/l
ESC
VALID
pH/ORP
Amperometric
Flow switch
General diagram (with Speedeo)
®
CHLORINE
SOLEO
FILTRATION, PH & ORP
28/04/2017 15:23:48 Water temp. :+29.0°C pH:7.8 ORP:607mV Cond:5264uS 3.28g/l
ESC
VALID
pH/ORP
Flow switch
Amperometric
SPEEDEO
VARIABLE SPEED PUMP
28/04/2017 15:23:48 Water temp. :+29.0°C pH:7.8 ORP:607mV Cond:5264uS 3.28g/l
ESC
ClpH +/-
®
VALID
pH +/-
VS
Cl
07
Loading...
+ 19 hidden pages