Pentair silentflo Owner's Manual

OWNER’S MANUAL
Should the installer or owner be unfamiliar with the correct installation or operation of this type of equipment you should contact the distributor/manufacturer for the correct advice before proceeding
For the Installation, Operation and Service of
SilentFlo
The pump must be supplied from a circuit
with the installation or operation of this product.
protected by a residual current device (RCD) with
a maximum rated residual current of 30mA
Table of Contents
Page
Model Data 2 Installation 3 Pressure Testing 4 Pump Mount 5 Tef on Taping Instructions 6 Fittings 6 Pool Outlets 6 Entrapment Protection 7 Testing and Certif cation 7 Outlets per Pump 7 Water Velocity 7 Electrical 8 Operation 9 Priming Pump 10 Service and Maintenance 11 Troubleshooting 12 Parts Breakdown 14
1
Model Data
2
Part
Output Power
Max Total Head
Number (m)
(W) (hp)
SF550100 550 3/4 18
SF750103 750 1 17
SF1100100 1100 1.5 15
SF1500100 1500 2 12
Technical Information
Inlet (Suction):
ABS Barrel Union to suit 50mm I.D PVC pipe to AS/NZS 1477
Outlet (Discharge): ABS Barrel Un ion to suit 50mm I.D PVC pipe
to AS/NZS 1477
Max Working Pressure: 260 kPa
Water Temperature Range: 5°C – 38°C
IP Rating: IPX5
Electrical Rating: 230-240V 50Hz single phase
Motor: Built in auto reset overload protection.
Flexible power supply cord 10Amp.
Recommended pH Range: 7.2 - 7.8 (Guide Only)
Maximum Ambient temperature: 55°C
3
Incorrectly installed or tested equipment may fail, causing severe injury or property damage.
Read the following instructions in this owner’s manual when installing and operating equipment. Have a trained pool professional perform all pressure tests.
1. Do not connect system to high pressure or mains water system.
2. Use equipment only in a swimming pool or spa pool installation.
3. Install pump with at least 2 hydraulically balanced main drains equipped with correctly installed, screw ­fastened, antientrapment certified covers according to local regulations.
4. Trapped air in system can cause explosion. Ensure all air is out of the system before operating or testing equipment.
Silentflo is electrically connected. Ensure that it is isolated from electrical supply during installation and any subsequent service work.
The pump should be installed and serviced by a suitably qualified person in order to avoid hazard.
These instructions are a guide only. Should you the installer or owner of the product be unfamiliar with the correct installation or operation of this product you should contact a suitably qualified person for advice.
Freezing conditions will damage the unit, as water expands as it freezes. Ensure that Silentflo is located so that it is not prone to freezing, or ensure that the product is disconnected and dried of water during cold conditions.
Installation
4
(Have a trained pool professional perform all pressure tests). Before pressure testing, make the following safety checks:
1. Check all clamps, bolts, lids, and system accessories prior to testing.
2. Release all air in system before testing.
3. Tighten trap lid to 4.1kg-m torque for testing.
4. Water pressure for test must be less than 170kPa (25 PSI)
5. Water tempertaure for test must be less than 38°C
6. Limit test to 24 hours. After test, visually check system to be sure it is ready for operation. Remove trap lid and retighten hand tight only.
Fire and burn hazard. Modern motors run at high temperatures. To reduce risk of fire, do not allow leaves, debris, or foreign matter to collect around the pump motor. To avoid burns when handling the motor, let it cool for at least 20 minutes before trying to work on it. A thermal overload switch protects the motor from heat damage during operation.
Only qualifi ed, licensed personnel should install pump. The electrical installation shall be in accordance with the national wiring rules (AS/NZS 3000) for class I, IP55 rated products. Refer to page 10 for Electrical Installation.
Pressure Testing