Pentair Siata V132 User Manual

SIATA V132
SFE
User Guide Siata V132-SFE
2 / 28 Ref. MKT-UG-003 / A - 14.10.2016
Original settings
Installation settings
Installation no. 2: Resin type3: Resin volume4: Valve serial no. 5: Controller serial no. 6: Outlet water hardness7: [°tH] Tank size8: [°tH] Brine tank size9: [L]
Hydraulic settings
10
Injector size11: BLFC12: DLFC13: Accessories14:
Electrical settings
15
Voltage16: [V] Frequency17: [Hz] Power18: [W]
Software settings
19
Regeneration start mode20: Prescale of the volumetric meter21: Vol. to be treated before starting the regen22: [L] Cycle 123: [Min] Cycle 2 : [Min] Cycle 3 : [Min] Cycle 4 : [Min] No. of regen. before a salt alarm is generated24: Days of interval for the mandatory regen25: Duration of the cycle end pulse26: [Min] Interval time between regeneration27: [H]
No. FR DE ES IT NL
1 Paramètres d'installation Installationseinstellungen Ajustes de instalación Impostazioni di installazione Installatie-instellingen 2 N° d’installation Installationsnr. Instalación nº Installazione n. Installatienr. 3 Type de résine Harztyp Tipo de resina Tipo di resina Harstype 4 Volume de résine Harzvolumen Volumen de resina Volume di resina Harsvolume 5 N° de série de vanne Ventil-Seriennr. Nº. de serie de válvula N. di serie valvola Klep serienr. 6 N° de série de contrôleur Seriennr. Steuerung N.º de serie del programador N. di serie controller Serienr. controller 7 Dureté de l'eau en sortie Auslass-Wasserhärte Dureza de agua de salida Durezza acqua in uscita Uitlaat waterhardheid 8 Taille du réservoir Behältergröße Tamaño del depósito Dimensioni bombola Tankgrootte
9 Taille du réservoir de saumure Solebehältergröße
Tamaño del depósito de salmuera
Dimensioni tino di salamoia Pekelbakgrootte
10 Réglages hydrauliques Hydraulikeinstellungen Ajustes hidráulicos Impostazioni idrauliche Hydraulische instellingen 11 Taille d’injecteur Injektorgröße Tamaño del inyector Dimensioni iniettori Injectorgrootte 12 Taille BLFC BLFC-Größe Tamaño BLFC Dimensioni BLFC Grootte BLFC 13 Taille DLFC DLFC-Größe Tamaño DLFC Dimensioni DLFC Grootte DLFC 14 Accessoires Zubehör Accesorios Accessori Accessoires 15 Paramètres électriques Elektrische Einstellungen Ajustes eléctricos Impostazioni elettriche Elektrische instellingen 16 Tension Spannung Tensión Tensione Spanning 17 Fréquence Frequenz Frecuencia Frequenza Frequentie 18 Alimentation Leistung Alimentación Potenza Stroom 19 Configuration Software-Einstellungen Ajustes de software Impostazioni software Software-instellingen
20
Mode de démarrage de régénération
Regenerationsstartmodus Modo de inicio de regeneración Modalità di avvio rigenerazione Regeneratie startmodus
21
Préétalonnage du compteur volumétrique
Voreinstellung des Volumenmessers
Prerreglaje del contador volumétrico
Preimpostazione del contatore volumetrico
Voorinstelling van de volumetrische waterteller
22
Vol. à traiter avant de commencer la regen
Zu behandelndes Vol. vor dem Start der Regen
Vol. a tratar antes de iniciar regen
Volume da trattare prima della rigenerazione
Vol. te behandelen voor het starten van de regen
23 Cycles Zyklus Ciclo Ciclo Cyclus
24
Nbre de régén. avant le déclenchement d’une alarme de sel
Anz. Regen. vor Salzmangelanzeige
N.º de regeneraciones antes de que se genere una alarma de la sal
N. di rigenerazioni prima di un allarme sale
Aantal regeneraties voordat een zoutalarm wordt gegenereerd
25
Jours d’intervalle pour la régénération obligatoire
Intervall in Tagen für obligatorische Regen
Días de intervalo para la regeneración obligatoria
Giorni di intervallo per rigenerazione obbligatoria
Intervaldagen voor de voorgeschreven regeneratie
User Guide Siata V132-SFE
Ref. MKT-UG-003 / A - 14.10.2016 3 / 28
Maintenance record book
Date¹ Description² Name³ Signature⁴
No. FR DE ES IT NL
1 Date Datum Fecha Data Datum 2 Description Beschreibung Descripción Descrizione Beschrijving 3 Nom Name Nombre Nome Naam 4 Signature Unterschrift Firma Firma Handtekening
User Guide Siata V132-SFE
4 / 28 Ref. MKT-UG-003 / A - 14.10.2016
1 . Generalities
Caution: Before handling the system, each user must read and understand the instructions in this document.The
safety instructions must be observed. Retain this document for future reference.
1.1. Scope of the documentation
The documentation provides the information necessary for appropriate use of the system. It informs the user to ensure efficient execution of operation or maintenance procedures. This document is not aimed at the installer. Visit our website https://www.pentairaquaeurope.com/product-finder/product-type/control-valves to download the installer manual
1.2. Release management
1.3. Manufacturer identifier, product
1.4. Applicable norms
This product complies with the following guidelines:
And meets the following technical standards :
1.5. Limitation of liability
Pentair Quality System EMEA products benefit, under specific conditions, from a manufacturer warranty that may be invoked by Pentair’s direct customers. Users should contact the vendor of this product for applicable conditions and in case of a potential warranty claim. Pentair accepts no liability for equipment installed by the user upstream or downstream of Pentair products, as well as for process/production processes which are installed and connected around or even related to the installation. Disturbances, failures, direct or indirect damages that are caused by such equipment or processes are also excluded from the warranty. Pentair shall not accept any liability for any loss or damage of profits, revenues, use, production, or contracts, or for any indirect, special or consequential loss or damage whatsoever. Please refer to the Pentair List Price to know more about terms and conditions applicable to this product.
Release Date Author Description
A 14.10.2016 STF First edition
Manufacturer: Pentair Manufacturing Italy Srl
Via Masaccio, 13 56010 Lugnano di Vicopisano (PI) – Italy
Product: Siata V132-SFE
• DM174: "Regulation of materials and objects that can be used in stationary collection, treatment, supply and distribution of water intended for human consumption.";
• Attestation de Conformité Sanitaire (ACS): "Test and Certification valid for France performed by independent laboratories for the evaluation of materials and components that are in contact with drinking water.";
• 2006/42/EC: Machinery Directive; • 2014/35/UE: Low Voltage Directive;
• 2014/30/UE: Electromagnetic compatibility;
• UNI EN ISO 9001 (Certificate no. 95.022 SSG ICS)
• EN 61010-1 • EN 61000-6-1
• EN 61000-6-2 • EN 61000-6-3
• EN 61000-6-4 • EN 55014-1
• EN 55014-2
A
User Guide Siata V132-SFE
Ref. MKT-UG-003 / A - 14.10.2016 5 / 28
EN
2 . Safety
2.1. Location of safety labels
Note: Ensure that the safety tags on the device are completely legible and clean. If necessary, replace them with
new labels and put them in the same places.
2.2. Hazards
All the safety and protection instructions contained in this document must be observed in order to avoid serious or permanent injuries, damage to property or environmental pollution. At the same time, any other legal regulations, accident prevention and environmental protection measures, as well as any recognized technical regulations relating to appropriate and risk-free methods of working which apply in the country and place of use of the device must be adhered to. Any non-observation of the safety and protection rules, as well as any existing legal and technical regulations, will result in a risk of temporary or permanent injury, damage to property or environmental pollution.
2.2.1. Personnel
Only qualified and professional personnel, based on their training, experience and instruction as well as their knowledge of the regulations, the safety rules and operations performed, are authorized to carry out necessary work.
2.2.2. Material
To ensure proper system operation, observe the following points :
• Be careful of electrical hazards due to the 230V/12V transformer.
• Do not put your fingers in the product (moving parts and residual voltage).
2.3. Hygiene and sanitation
Contact your local dealer and ask for a sanitization treatment if the treated water has an off-taste or an unusual odor. It is strongly recommended to disinfect the system at least once a year.
3 . Description
3.1. Technical specifications
3.2. Environmental conditions
Pressure ............................................ ..............Hydrostatic: 22 bar / Recommended operating pressure: 1.5 - 6.0 bar
Maximum backwash (ΔP 1.8 bar):..... ..............3.0 m3/h
• Maximum relative humidity : 80% for temperatures up to 31 °C decreasing linearly to 50% relative humidity at 40°C;
• Main supply voltage fluctuations up to ±10% of the nominal voltage.
• Temperature from 5°C to 38°C.
• Not directly exposed to the sun.
• Installed in a dry place.
A
PN: SN:
Valve serial label
Part number
Serial number
Controller serial label
Serial label
A
User Guide Siata V132-SFE
6 / 28 Ref. MKT-UG-003 / A - 14.10.2016
3.3. Description and components location
3.4. Bypassing
If the system is equipped with a bypass and if a problem occurs, turn the valves to bypass the system as shown in the picture below.
4 . Programming
Note: The controller must be plugged to be programmed.
After 30 seconds without a button press, the unit returns to normal operation.
4.1. Basic programming
Note: Menus are displayed in a defined and incremental order.
While the parameters are being edited, the icon is on and blinking.
Display format change
Time of day
Day of the week
A Press to enter the menus sequence. B Adjust the format to be displayed with and .
C Press to validate the selection and advance to the next parameter.
D Adjust the time with and .
Time flashes.
E Press to validate the selection and advance to the next parameter.
F Adjust the day with and .
Day flashes.
G Press to validate the selection and advance to the next parameter.
A
UP button
DOWN button
LCD display
Injector
Inlet (quick connection)
Regen button
Outlet (quick connection)
Closed drain
Twin pilots
Long manifold
Injector
Meter
Inlet (threaded connection)
Outlet (threaded connection)
Drain
External pilot connections
Short manifold
Normal
operation
In Bypass
In InOut Out
A
A
A
A
A
A
A
A
A
SUTUMO WE TH FR SA
A
A
User Guide Siata V132-SFE
Ref. MKT-UG-003 / A - 14.10.2016 7 / 28
EN
Day of regeneration
Note: The display shows “dX Y” where X is the day of the week (1-7) and Y shows whether the selected day is enabled
for regeneration “1” or not, “0”.
Time of regeneration
4.2. History
To access the recorded information, press and hold for 5 seconds.
5 . Operation
5.1. Recommendations
• Use only regenerate salts designed for water softening EN973;
• For optimal system operation, the use of clean salt free from impurities is recommended (for example salt pellets);
• Do not use ice melt, block, or rock salts;
• The sanitizing process (both with liquid and electrochlorination) introduces chlorine elements which may reduce the lifetime of the ion exchange resins. Refer to the technical guides for resins in common use, providing necessary checks on the system.
5.2. Manual regeneration
6 . Error messages
The following error messages may be displayed during operation:
7 . Maintenance
Mandatory: Cleaning and maintenance shall take place at regular intervals in order to guarantee the proper
functioning of the complete system, and be documented in the Maintenance record book.
8 . Troubleshooting
Please follow this procedure for any technical support:
A Collect the required information for a technical assistance request.
Product identification (see 2.1. Location of safety labels, page 5 and Original settings, page 2);Error number displayed on the controller;
B Contact your local dealer who installed this device (see contact details on last page).
Also call him if the water tastes salty, if the water is not softened or if there is no salt consumption.
H Select the day with and enable or disable the regeneration with .
The days with enabled regeneration flash.
I Press to validate the selection and advance to the next parameter.
J Adjust the time of regeneration with and .
Time flashes.
K Press to validate the selection.
"End" appears on the screen, programming is now complete.
Immediate regeneration
A Press and hold for 5 seconds.
Regeneration icon displayed.Camshaft starts rotating to cycle C1.
Note: Salt alarm, the brine tank is empty. Press any key to acknowledge this alarm and reset the salt alarm
counter to the programmed value. No regenerations are carried out during the salt alarm.
Refill the brine tank with salt.
Note: Microswitch alarm. The module cannot find the service position. No regenerations are carried out
during the microswitch alarm.
Call your local dealer. See 8 . Troubleshooting, page 7.
A
A
SUTUMO WE TH FR SA
A
A
A
A
A
A
A
A
A
User Guide Siata V132-SFE
8 / 28 Ref. MKT-UG-003 / A - 14.10.2016
1 . Généralités
Attention: Avant de manipuler le système, chaque utilisateur doit lire et assimiler les instructions contenues dans le pré-
sent document. Les consignes de sécurité doivent être respectées. Conserver ce document pour référence ultérieure.
1.1. Champ d’application de ce document
Le document contient les informations nécessaires à une utilisation appropriée du produit. Il informe l’utilisateur afin de garantir la bonne exécution des procédures d’utilisation et de maintenance. Ce document n’est pas destiné à l’installateur. Visitez notre site Web https://www.pentairaquaeurope.com/product-finder/product-type/control-valves pour télécharger le manuel d’installation
1.2. Gestion des versions
1.3. Identifiant du fabricant, produit
1.4. Normes applicables
Ce produit est conforme aux directives suivantes :
Et est conforme aux normes techniques suivantes :
1.5. Limitation de responsabilité
Dans le cadre du système de qualité Pentair, les produits EMEA bénéficient, sous certaines conditions, d’une garantie du fabricant à la­quelle les clients directs de Pentair peuvent recourir. Les utilisateurs doivent contacter le revendeur de ce produit pour les conditions applicables et dans le cas d’une éventuelle demande en garantie. Pentair décline toute responsabilité concernant des équipements ins­tallés par l’utilisateur en amont ou en aval des produits Pentair, ainsi que pour tout procédé ou processus de production installé et rac­cordé autour de l’installation, voire lié avec celle-ci. Tout dysfonctionnement ou défaillance et tout dommage direct ou indirect résultant de tels équipements ou processus sont également exclus de la garantie. Pentair n’assume aucune responsabilité pour toute perte ou tout préjudice en matière de profits, de revenus, d’utilisation, de production ou de contrats, ou pour toute perte ou tout dommage indirect, spécial ou consécutif, quelle qu’en soit la nature. Veuillez consulter la liste de prix de Pentair pour en savoir plus sur les modalités et les conditions applicables au présent produit.
Version Date Auteur Description
A 14.10.2016 STF Première édition
Fabricant : Pentair Manufacturing Italy Srl
Via Masaccio, 13 56010 Lugnano di Vicopisano (PI) – Italie
Produit : Siata V132-SFE
• DM 174 : « Règlement relatif aux matériaux et aux objets pouvant être utilisés dans les installations fixes de captage, de traitement, d’adduction et de distribution d’eau destinée à la consommation humaine » ;
• Attestation de Conformité Sanitaire (ACS) : « Essai et certification valable pour la France effectués par des laboratoires indépen­dants pour l’évaluation des matériaux et des composants qui sont en contact avec l’eau potable. »
• 2006/42/CE : Directive machines ; • 2014/35/UE : Directive « Basse tension »;
• 2014/30/UE : Compatibilité électromagnétique ;
• UNI EN ISO 9001 (Certificat n° 95.022 SSG ICS)
• EN 61010-1 • EN 61000-6-1
• EN 61000-6-2 • EN 61000-6-3
• EN 61000-6-4 • EN 55014-1
• EN 55014-2
A
User Guide Siata V132-SFE
Ref. MKT-UG-003 / A - 14.10.2016 9 / 28
FR
2 . Sécurité
2.1. Emplacement des étiquettes de sécurité
Information: S’assurer que les étiquettes de sécurité sur l’appareil sont parfaitement lisibles et propres. Si nécessaire,
les remplacer par de nouvelles étiquettes à disposer au même endroit.
2.2. Risques
Toutes les instructions de sécurité et de protection contenues dans ce document doivent être respectées afin d’éviter des blessures graves ou permanentes, des dommages matériels ou une pollution environnementale. De même, toutes les autres réglementations et mesures de prévention des accidents et de protection de l’environnement, ainsi que tout règlement technique reconnu relatif aux méthodes de travail sûres et appropriées applicables dans le pays et sur le lieu d’utilisation de l’appareil doivent être respectés. Toute violation des règles de sécurité et de protection ou de toute réglementation légale et technique existantes pourra entraîner des blessures, dommages matériels ou une pollution environnementale irrémédiables ou temporaires.
2.2.1. Personnel
Seuls des personnels qualifiés et des professionnels dûment formés sont autorisés à exécuter les interventions requises, en fonction de leur formation, de leur expérience, des instructions reçues et de leur connaissance des règles de sécurité ainsi que des opérations à réaliser.
2.2.2. Matériel
Afin d’assurer le bon fonctionnement du système, tenir compte des points suivants :
• Prendre garde aux dangers électriques liés à la présence du transformateur 230 V/12 V.
• Ne pas mettre une main dans l'appareil (pièces mobiles et tension résiduelle).
2.3. Hygiène et désinfection
Contacter votre revendeur et demander un traitement de désinfection si l’eau traitée a un mauvais goût ou une odeur inhabituelle. Il est fortement recommandé de désinfecter le système au moins une fois par an.
3 . Description
3.1. Caractéristiques techniques
3.2. Conditions environnementales
Pression ................................................. ............... Hydrostatique : 22 bars / Pression de fonctionnement recommandée : 1,5 - 6,0 bars
Détassage maximum (Δp 1,8 bar) :........ ............... 3,0 m3/h
• Humidité relative maximale : 80 % pour des températures allant jusqu’à 31 °C décroissant linéairement à 50 % d’humidité relative à 40 °C ;
• Variations de la tension d'alimentation secteur de ± 10 % de la tension nominale.
• Température de 5 °C à 38 °C.
• Pas d’exposition directe au soleil.
• Conserver dans un endroit sec.
A
PN: SN:
Étiquette de série de vanne
Référence
Numéro de série
Étiquette de série de contrôleur
Étiquette de série
A