Section I.Installing Light Fixture During New Pool or Spa Construction .....................................................................3
Section II.Replacing Light Fixture in an Existing Pool or Spa ........................................................................................4
Section III.Switch Options for Synchronizing Multiple SAL Spectrum AquaLight Fixtures ........................................ 5
Section VI.SAL Spectrum AquaLight Replacement Parts .............................................................................................8
Sección I.Instalación del artefacto de iluminación durante la construcción de una piscina nueva o baño termal ..... 11
Section I.Installation du luminaire pendant la construction d’une nouvelle piscine ou d’un nouveau spa .............. 19
DANGER
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
This underwater light must be installed by a licensed or certified electrician in accordance with the National
Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical
hazard which could result in death or serious injury to pool or spa users, installer, or others due to electrical
shock, and may also cause damage to property. Read and follow the specific instructions below.
WARNING
Before installing this underwater light, read and follow all warning notices and instructions accompanying this light. Failure
to follow safety warnings and instructions can result in severe injury, death, or property damage. Call (800) 831-7133 for
additional free copies of these instructions.
Important Notice
Attention Installer.
This manual contains important information about the installation, operation and safe use of this
product. This information should be given to the owner/operator of this equipment.
Pentair Water Pool and Spa, Inc.
1620 Hawkins Ave., Sanford, NC 27330 • (800) 831-7133 • (919) 566-8000
10951 West Los Angeles Ave., Moorpark, CA 93021 • (800) 831-7133 • (805) 553-5000
Visit us on the Internet at: www.pentairpool.com or www.staritepool.com
Rev. D 10-5-071P/N 650041
DANGER! Risk of Electrical Shock or Electrocution!
This product must be installed by a licensed or certified electrician or a qualified pool serviceman
in accordance with the National Electrical Code and all applicable local codes and ordinances.
Improper installation will create an electrical hazard which could result in death --- or serious injury
to pool users, installers or others due to electrical shock, and may also cause damage to property.
Always disconnect the power to the pool light at the circuit breaker before servicing the light.
Failure to do so could result in death or serious injury to serviceman, pool users or others due to
electrical shock. READ AND FOLLOW ALL INSTRUCTIONS IN THIS MANUAL.
WARNING — Important Safety Information for Pentair Niche and Light Installation
•
All Niche and Light installations must conform with all codes. If local codes mandate a
cord seal, use Pentair plastic niches (P/N 79206600 and P/N 79206700).
•Under no circumstances replace lights by splicing wire under water or behind niche.
WARNING — RISK OF ELECTRIC SHOCK AND INJURY.
USE ONLY THE INSTALLATION METHOD SPECIFIED BELOW.
Important Safety Information for Fountain Fixture Installations
Swimming Pool or SpaWet-Niche Swimming PoolFixture Housing (Forming Shell) ONLY.
(or Spa) Luminaire (Light)DO NOT USE Fountain Fixture Stand.
FountainWet-Niche SubmersibleFixture Housing (Forming Shell) or
Swimming Pool (or Spa)Fountain Fixture Stand.
Luminaire (Light)
(*) Note: Wet-niche luminaires complying with requirements for both uses may bear both the Listed Wet-Niche Swimming Pool (or Spa)
Luminaire UL Mark and the Listed Wet-Niche Submersible Luminaire UL Mark. A luminaire not bearing the corresponding UL Listing Mark
is not considered by UL to have been produced under UL’s Listing and Follow-Up Service for the associated usage location.
1620 Hawkins Ave., Sanford, NC 27330 • (800) 831-7133 • (919) 566-8000
10951 West Los Angeles Ave., Moorpark, CA 93021 • (800) 831-7133 • (805) 553-5000
This document is subject to change without notice.
Trademarks and Disclaimers: Pentair Water Pool and Spa, SAL, Spectrum AquaLight, SAm, and Spectrum Amerlite are registered trademarks of Pentair
Water Pool and Spa, Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names of their
products. Pentair Water Pool and Spa, Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
P/N 6500412Rev. D 10-5-07
Section I.Installing Light Fixture
During New Pool or Spa
Construction
A. The electrician must complete preparatory
steps before light fixture is installed; see
Figure 1.
1.Ensure that the pool or spa meets the
requirements of the current National
Electrical Code and all local codes
and ordinances. A licensed or
certified electrician must install the
electrical system to meet or exceed
those requirements before the
underwater light is installed. Some
of the requirements of the National Electrical Code which the pool's or spa’s electrical systems must meet are as follows.
a.The lighting circuit must have a Ground Fault Circuit Interrupter (GFCI) for line voltage models, and must have an
appropriately rated circuit breaker.
b.The Junction Box (or, for 12 volt models, the low voltage transformer) must be located at least eight (8) inches above
water level, at least four (4) inches above ground level, and at least 48 inches from the edge of the pool or spa; see
Figure 1.
c.The light fixture and all metal items within five (5) feet of the pool or spa must be properly electrically bonded.
To GFCI, Circuit
Breaker and
Power Source.
Figure 1.
Rigid
Conduit
#8 AWG Ground
Connector bonded
to rebar.
4" min.
48"
min.
8" min. Junction Box or
low Voltage Transformer.
18" min. to top of Lens.
Pilot screw @ 12 o'clock position
Concrete must be cut
back around Niche to
6.0"
allow for a compacted
plaster seal.
Coil 4 ft. of light cord
around Fixture.
d.The wet niche must be properly installed so the pilot screw hole is at the 12 o’clock position and that the top edge of
the underwater light’s lens is at least 18 inches below the surface of the water in the pool; see Figure 1. (Not more than
48 inch depth in Canada.)
NOTE
The required orientation of all Pentair lights is with the pilot screw at the 12 o’clock position. This is guaranteed by proper niche
installation.
e.The wet niche must be properly electrically bonded and grounded via the No. 8 AWG ground connector located at the
rear of the niche; see Figure 1.
NOTE
The pool or spa electrical system can be verified with a Pool and Spa Electrical Qualification Test kit. The test kit is available from Pentair
Water Pool and Spa, Inc. The electrical system inspection using this kit must be performed by trained and certified personnel.
2.To be certain that the pool or spa’s electrical system meets all applicable requirements, the electrician should also consult
the local building department.
®
3.Use only Pentair Water Pool and Spa
B. Steps to perform after the electrical system requirements are met.
1.Feed cord through conduit to Junction box, leaving at least four (4) feet of cord at the light fixture to coil around the light;
see Figure 1. This four (4) feet of cord around the light allows the light to be serviced after the pool or spa is filled with
water.
2.Cut the cord at the Junction Box, leaving at least six (6) inches of cord to make connections.
3.Strip six (6) inches of the outer cord jacket to expose the three insulated wires.
the three (3) inner wires.
4.Install strain relief over cord jacket and connect all three (3) wires to the corresponding circuit wires in the Junction Box.
Install the Junction Box cover.
wet niches to insure proper bonding and grounding connections.
Be careful not to damage the insulation on
WARNING
Never operate this underwater light for more than 10 seconds unless it is totally submerged in water. Without total submersion, the
light assembly will get extremely hot, which may result in serious burns or in breakage of the lamp or lens. This may result in serious
injury to pool or spa users, installers, or bystanders, or in damage to property.
Rev. D 10-5-073P/N 650041
5.Coil the 4 foot length of cord around the fixture and place the light assembly into the niche.
6.Engage the retainer tab on the bottom of the face ring, then pivot the top of the fixture inward and tighten the special
pilot screw.
WARNING
Use only the special pilot screw provided with this underwater light. This screw mounts and electrically grounds the housing
securely to the mounting ring and wet niche. Failure to use the screw provided could create an electrical hazard which could
result in death or serious injury to pool or spa users, installers or others due to electrical shock.
7.Fill the pool or spa until the underwater light is completely submerged in water before operating the light for more
than 10 seconds. Turn on main switch or circuit breaker, and the switch which operates the underwater light, to
check for proper operation. Refer to Operating Instructions, Section IV.
Section II.Replacing Light Fixture in an Existing Pool or Spa
DANGER
Risk of Electrical Shock or Electrocution
This underwater light must be installed by a licensed or certified electrician or a qualified pool or spa serviceman in
accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will
create an electrical hazard which could result in death or serious injury to pool or spa users, installers or others due to
electrical shock, and may also cause damage to property.
Always disconnect the power to the pool or spa light at the circuit breaker before servicing the light. Failure to do so
could result in death or serious injury to serviceman, pool or spa users or others due to electrical shock.
A. Before replacing the light fixture.
1.Verify that the pool or spa meets the requirements of the current National Electrical Code and all local codes and
ordinances. A licensed or certified electrician must install the electrical system to meet or exceed those
requirements before the underwater light is installed. Some of the requirements of the National Electrical Code
which the pool or spa’s electrical system must meet are as follows:
a.The lighting circuit must have a Ground Fault Circuit Interrupter (GFCI) for line voltage models, and must have
an appropriately rated circuit breaker.
b.The Junction Box (or, for 12 volt models, the low voltage transformer) must be located at least 8 inches above
ground or water level, at least four (4) inches above ground level, and at least 48 inches from the edge of the pool
or spa; see Figure 1.
c.The light fixture and all metal items within 5 feet of the pool or spa must be properly electrically bonded.
d.The wet niche must be properly installed so that the top edge of the underwater light’s lens is at least 18
inches below the surface of the water in the pool or spa; see Figure 1.
e.The wet niche must be properly electrically bonded and grounded via the No. 8 AWG ground connector
located at the rear of the niche; see Figure 1.
NOTE
The pool or spa electrical system can be verified with a Pool and Spa Electrical Qualification Test Kit. The test kit is available from
Pentair Water Pool and Spa, Inc. The electrical system inspection using this kit must be performed by trained and certified
personnel.
2.To be certain that the pool or spa’s electrical system meets all applicable requirements, the electrician should also
consult the local building department.
®
3.Use only Pentair Water Pool and Spa
B. Replacing the light fixture after electrical system requirements are met.
P/N 6500414Rev. D 10-5-07
wet niches to insure proper bonding and grounding connections.
WARNING
Failure to bring the pool or spa’s electrical system up to code requirements before installing the underwater light will create an
electrical hazard which could result in death or serious injury to pool or spa users, installers, or others due to electrical shock,
and may also cause damage to property.
NOTE
The light fixture may be replaced without removing water from the pool or spa.
1.Turn off main electrical switch or circuit breaker, as well as the switch which operates the underwater light.
2.To remove the light assembly, remove the special pilot screw at top of the face ring, remove the light assembly
from the niche, and place the assembly on the deck.
WARNING
Be sure to keep the special pilot screw from this underwater light. This screw mounts and electrically grounds the housing
securely to the mounting ring and wet niche. Failure to use the screw provided could create an electrical hazard which could
result in death or serious injury to pool or spa users, installers or others due to electrical shock.
3.Remove Junction Box cover, disconnect the light fixture wires and strain relief, then pull the cord out of the conduit
from the niche.
4.Feed the new light fixture cord through the conduit from the niche to the Junction Box.
NOTE
Depending on the length of the conduit, special tools may be required to pull the cord through the conduit.
5.Leave at least 4 feet of cord to coil around the light fixture; see Figure 1. This allows the light to be serviced after
the pool or spa is filled with water.
6.Cut the cord at the Junction Box, leaving at least 6 inches of cord to make connections.
7.Strip 6 inches of the outer cord jacket from the cord to expose the three insulated wires. Be careful not to damage
the insulation on the three inner wires.
8.Install the strain relief over the cord jacket and connect all three wires to the corresponding circuit wires in the
Junction Box, black wire to power, white wire to common, and green wire to ground. Install the Junction Box cover.
WARNING
Use only the special pilot screw provided with this underwater light. This screw mounts and electrically grounds the housing
securely to the mounting ring and wet niche. Failure to use the screw provided could create an electrical hazard which could
result in death or serious injury to pool or spa users, installers or others due to electrical shock.
9.Replace light assembly into the niche and tighten the special pilot screw.
WARNING
Never operate this underwater light for more than 10 seconds unless it is totally submerged in water. Without total submersion,
the light assembly will get extremely hot, which may result in serious burns or in breakage of the lamp or lens. This may result in
serious injury to pool or spa users, installers, or bystanders, or in damage to property.
10. Fill the pool or spa until the underwater light is completely submerged in water before operating the light for more
than 10 seconds. Turn on main switch or circuit breaker, as well as the switch which operates the underwater
light, to check for proper operation. Refer in Operating Instructions, Section IV.
Section III.Switch Options for Synchronizing Multiple SAL®/SAm® Fixtures
A. Multiple SAL lights and/or SAm lights with colors ALWAYS synchronized.
1.To the extent allowed by code and capacity of the electrical equipment, multiple SAL lights and SAm lights may be
controlled with a single switch so their colors will always be synchronized.
B. Multiple SAL lights and SAm lights controlled separately with color synchronization capability.
1.Separate switches may be used to control the on/off and color functions of each SAL/SAm. It is recommended that
these switches are located next to each other to facilitate simple color synchronization when desired.
Rev. D 10-5-075P/N 650041
Section IV.SAL® Operating Instructions
A. Switch ON -- The SAL turns on with the color it displayed when it was turned off.
st
OFF/ON -- The SAL illuminates white for up to 30 seconds to synchronize with other SAL lights or SAm
B. 1
Spectrum Amerlite lights, then rolls through the spectrum until receipt of the next switch command.
nd
OFF/ON -- The SAL locks onto the color displayed.
C. 2
st
D. OFF/ON -- Repeats 1
E. OFF/ON -- Repeats 2
OFF/ON action (B).
nd
OFF/ON action (C).
NOTE: The OFF/ON switch action must be done in less than 5 seconds.
NOTE
To synchronize colors on multiple SALor SAm lights, perform the above actions on both of their switches simultaneously.
Section V.Replacing Lamps (see Figure 2)
DANGER
Always disconnect power to the pool or spa light at the circuit breaker before servicing the light. Failure to do so could
result in death or serious injury to installer, serviceman, pool or spa users or others due to electrical shock.
A. Turn off main electrical switch or circuit
breaker, as well as the switch which operates
the underwater light.
B. The following items will be needed:
1.A new lens gasket (p/n 79108500).
2.Four (4) new lamps. See Table 1.
LampLampLampLampNo. p erP/N
VoltageWattageSizeTypeFixture
12V35WMR81650036
12V35WMR11FTF3650037
* NOTE: Both 120V and 12V SALs use the same 12V lamps.
WARNING
Replace all lamps with lamps of the same type and wattage.
Failure to replace the lamps with those of the same type will
damage the light assembly and may cause an electrical hazard
resulting in death or serious injury to pool or spa users, installers,
or others due to electrical shock, and may also cause damage to
property.
C. To remove light assembly, remove the special pilot screw at
top of face ring, remove light assembly from niche, and
gently place assembly on deck. It is not necessary to drain
down the pool or spa.
WARNING
Be sure to keep the special pilot screw from this underwater light.
This screw mounts and electrically grounds the housing securely
to the mounting ring and wet niche. Failure to use the screw
provided could create an electrical hazard which could result in
death or serious injury to pool or spa users, installers or others
due to electrical shock.
WARNING
Be sure the power of OFF before removing or installing lamps.
Allow lamps to cool before re-lamping. This light fixture uses
quartz halogen lamps. Hold lamps on the outside only. DO NOT
touch the bulb or inside reflector surface with bare hands; doing
so could severely reduce lamp life.
Wire Clamp
Figure 2.
Lamp Specifications *
Pilot Screw
w/Gum Washer
S/S Face Ring Assy.
Screw
Table 1.
Dichro Plate
Retaining Screws (2)
Dichro Assy.
Lamp - MR11 (3)
Lamp - MR8 (1)
Housing Assy.
Lens
Gasket
D. Disassemble the light fixture and remove lamps. See Figure 2.
P/N 6500416Rev. D 10-5-07
1.Remove the Phillips hex head screw from the wire spring clamp.
2.Remove the wire spring clamp, face ring, lens and gasket from the housing. Remove the gasket from the lens.
3.Remove the two Phillips hex head Dichro Plate retaining screws.
4.Carefully remove the Dichro Plate and four lamps. Discard lamps.
E. Install the new lamps. See Figure 2.
1.Install the MR8 (small) lamp in the socket labeled "SMALL LAMP".
2.Install the three MR11 lamps in the remaining sockets.
3.Position the Dichro Plate over the lamps with round opening over the MR8 (small) lamp. Insure that all three guide
tabs are inside of the lamp reflector.
4.Install the two Dichro Plate retaining screws. Do not over-tighten.
WARNING
Never operate the underwater light for more than 10 seconds unless it is totally submerged in water. Without total submersion,
the light assembly will get extremely hot and may result in serious burns or in breakage of the lamp or lens. This may result in
serious injury to pool or spa users, installers, or bystanders, or in damage to property.
WARNING
Always install a new lens gasket (part number 79108500) whenever disassembling the light. Failure to do so may permit water
to leak into the assembly which could cause:
(a) an electrical hazard resulting in death or serious injury to pool or spa users, installers, or others due to electrical shock, or
(b) breakage of the lamp or lens, which likewise could result in serious injury to pool or spa users, installers, or
bystanders, or in damage to property.
F. Reassemble the fixture. See Figure 3.
1. Remove the gasket from the lens and install a new gasket, p/n 79108500, on the lens. A NEW LENS GASKET
MUST BE USED EACH TIME THE LIGHT IS REASSEMBLED.
2. While holding the fixture upright, place the lens with gasket and face ring on top of the light shell. Align the pilot
screw in the face ring with the arrow on the label marked "Arrow on this label must line up with the pilot screw on
the face ring".
3. While holding the aligned face ring and shell together, turn the assembly upside down and set it on the old gasket,
using the old gasket as an assembly fixture. This will keep the lens and gasket assembly from being pushed out of
the face ring while you secure it to the light fixture. See Figure 4.
4. With the bent ends of the circular wire clamp pointing up, spread the clamp and place it in the "U" recesses of the
face ring clips. Ensure that the bent ends of the clamp are located between the pair of clips as shown in Figure 3,
location A. Check to see that the clamp is properly engaged with all of the clips.
5. Hold the ends of the wire clamp together. Insert the bolt through the open loop and thread it into the nut. Using a
Phillips head screwdriver or a 3/8 in. hex nut driver, tighten the screw until the distance between the ends of the
clamp equals ¼ inch or less. See Figure 4.
6. Discard the old gasket.
G. Reinstall the fixture.
1. Coil the extra cord around the fixture and place the light assembly into the niche.
2. Engage the retainer tab on the bottom of the face ring, then pivot the top of the fixture inward and tighten the
special pilot screw.
Rev. D 10-5-077P/N 650041
WARNING
Use only the special pilot screw provided with this
underwater light. This screw mounts and electrically
grounds the housing securely to the mounting ring and
wet niche. Failure to use the screw provided could
create an electrical hazard which could result in death
or serious injury to pool or spa users, installers or
others due to electrical shock.
H. Fill pool or spa until the underwater light is
completely submerged in water before operating
the light for more than 10 seconds. Turn on main
switch or circuit breaker, as well as the switch
which specifically operates the underwater light,
to check for proper operation.
Wire Clamp
Figure 3.
Figure 4.
Screw
Clips
Pilot Screw
A
Position of
Wire Clamp
Line up Pilot Screw
with Arrow on Label
Section VI.SAL® Spectrum AquaLight® Replacement Parts
2
1
9
1650036Lamp, MR8, 35W 12V, (1 req.)
2650037Lamp, MR11 FTF, 35W 12V, (3 req.)
3650066Dichro Assembly
4650052Screw, S/S, Phillips hex hd., 6-32 x 3/8 in.
579108500Gasket, Lens
6650045Lens, clear, 4 in. dia., tempered
679107800Lens, clear, 4 in. dia., tempered (Canada only)
779104800Pilot Screw with captive gum washer, brass
7619355Pilot Screw with captive gum washer, S/S
879111600Face Ring Assembly, S/S
979210400Uni-tension wire assy., S/S w/ welded nut
NOT SHOWN
619570XPS3-Receiver, X-10
3
4
8
7
56
SAVE THESE
INSTRUCTIONS.
P/N 6500418Rev. D 10-5-07
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.