Pentair ONGA INTELLIMASTER INJ-4500L 075, ONGA INTELLIMASTER INJ-4500L 022, ONGA INTELLIMASTER INJ-4500L 015 User Quick Manual

USER QUICK MANUAL
ONGA
R
SAFETY INSTRUCTIONS
Please read the IMPORTANT SAFETY INFORMATION below, and all Warning and Caution information elsewhere.
System design, installation, commissioning and maintenance must be carried out only by personnel who have the necessary training and experience. They must carefully read this safety information and the instructions in this Guide and follow all information regarding transport, storage, installation and use of the Intellimaster series, including the specified environmental limitations.
Electric shock hazard! Disconnect and ISOLATE the Intellimaster series before attempting any work on it. High voltages are present at the terminals and within the drive for up to 10 minutes after disconnection of the electrical supply. Always ensure by using a suitable multimeter that no voltage is present on any drive power terminals prior to commencing any work.
Where supply to the drive is through a plug and socket connector, do not disconnect until 10 minutes have elapsed after turning off the supply.
The STOP function does not remove potentially lethal high voltages. ISOLATE the drive and wait 10 minutes before starting any work on it. Never carry out any work on the Drive, Motor or Motor cable whilst the input power is still applied.
The entry of conductive or flammable foreign bodies should be prevented. Flammable material should not be placed close to the drive Relative humidity must be less than 95% (non-condensing).
Ensure that the supply voltage, frequency and single phase input correspond to the rating of the Intellimaster as delivered.
Never connect the mains power supply to the Output terminals U, V, W.
Do not install any type of automatic switchgear between the drive and the motor.
The driven motor can start at power up if the enable input signal is present.
Do not perform any flash test or voltage withstand test on the Intellimaster series. Any electrical measurements required should be carried out with the Intellimaster series disconnected.
Danger : Indicates a risk of electric shock, which, if not avoided, could result in damage to the equipment and possible injury or death.
Danger : Indicates a potentially hazardous situation other than electrical, which if not avoided, could result in damage to property.
DISPLAY
2> LCD Color
1> LCD Display
<Alarm is Red><Stop is Purple><Operation is Blue>
Sensor Alarm
VFD Alarm
Pump Alarm
Parameter 1
Parameter 2
VFD Operation
VFD Stop
Changing to Constant Speed(MANUAL OPERATION MODE)
To set to MANUAL OPERATION MODE, press down on the STOP button for 3 seconds. The AUTO indication will disappear. In MANUAL OPERATION MODE, press the and once the indication is on Hz, change the constant speed required by pressing either the or and press the run button once the Hz is selected.
Changing to Constant Pressure(AUTO OPERATION MODE)
To set to AUTO OPERATION MODE, press down on the STOP button for 3 seconds. The AUTO indication will appear. In AUTO OPERATION MODE, the pump will operate according to the set pressure.
*NOTE: THIS IS THE CURRENT DEFAULT SETTING
21
SETTING
1> Switching to Constant Pressure or Constant Speed
2> Setting the pressure
Press or
button for 2 seconds.
Press or
button to set the desired pressure.
3
4
Press button to
complete the pressure setting.
STOP
RUN