Pentair Nuheat Signature Operating Instructions Manual

1SIGNATURE OPERATING MANUAL
THERMAL BUILDING SOLUTIONS WW W.NUHEAT.COM
OPERATING MANUAL
SIGNATURE
2 THERMAL BUILDING SOLUTIONS
3SIGNATURE OPERATING MANUAL
TABLE OF CONTENTS
SYSTEM TESTS .................................................................................................... 5
SETUP WIZARD .................................................................................................... 5
GFCI ..................................................................................................................... 5
SECTION 1: HOME SCREEN ................................................................................. 6
1.1 Temporary Bypass and Hold Options ............................................ 7
1.2 Energy Use ................................................................................ 8
1.3 Settings .................................................................................... 8
SECTION 2: SETUP/PREFERENCES ...................................................................... 9
2.1 Language .................................................................................. 9
2.2 Date .......................................................................................... 9
2.3 Time ......................................................................................... 9
2.4 Unit ......................................................................................... 10
2.5 Operating Mode ....................................................................... 10
2.6 Temperature Control ................................................................. 11
2.7 Temperature Display ................................................................ 12
2.8 Floor Type ................................................................................ 12
2.9 Early Start ............................................................................... 12
2.10 Floor Limit ............................................................................... 13
2.11 Screen Brightness .................................................................... 13
2.12 Screensaver ............................................................................ 13
SECTION 3: PROGRAM/SCHEDULE .................................................................... 14
SECTION 4: WIFI SETTINGS ............................................................................... 15
SECTION 5: WEATHER SETTINGS ...................................................................... 16
SECTION 6: THERMOSTAT INFORMATION .......................................................... 17
SECTION 8: WIFI TROUBLESHOOTING ................................................................ 19
4 THERMAL BUILDING SOLUTIONS
THANK YOU FOR CHOOSING NUHEAT SIGNATURE!
You have chosen the most advanced thermostat to control your Nuheat electric floor heating system. This manual will cover each of the features of the Nuheat SIGNATURE thermostat.
INTRODUCTION
5SIGNATURE OPERATING MANUAL
The Nuheat SIGNATURE thermostat features a series of diagnostic tests to confirm the thermostat is installed and functioning properly.
The System Tests option is available the first time the thermostat is connected to power or after a factory reset is initiated.
The Nuheat SIGNATURE thermostat features a Setup Wizard to guide you through the basic setup process.
The Setup Wizard is available the first time the thermostat is connected to power or after a factory reset is initiated. Refer to section 6 on page 17.
The Nuheat SIGNATURE thermostat has a built-in GFCI (Ground Fault Circuit Interrupter). The GFCI protects against risks of electrocution caused by a current leakage. If the current leakage exceeds 5 mA, the GFCI will automatically be triggered, thus cutting power to the floor heating system. To indicate the fault, a message will appear on the screen informing you of the fault. To reset the GFCI, press the button on the right side of the thermostat. If problem persists, contact Nuheat at 1.800.778.WARM(9276).
SETUP WIZARD
GFCI
SYSTEM TESTS
6 THERMAL BUILDING SOLUTIONS
1. Change date and time
2. Access WiFi settings
3. Access weather forecast (WiFi connection required)
4. Current temperature
5. Target temperature or setpoint
6. Operating mode - Auto* means the thermostat is following the program/schedule. Manual means the thermostat is NOT following the program/schedule and is being controlled manually. Refer to section 2.5 on page 10.
7. Increase the temperature
8. Decrease the temperature
9. Heating indicator - when visible, system is heating
10. Access Energy Use data
11. Access Settings menu
*When thermostat is in Auto mode:
Resume Programmed Schedule
- only appears if thermostat is in Auto mode and temperature is manually increased/decreased Hold Options - only appears if thermostat is in Auto mode and temperature is manually increased/decreased. Refer to section 1.1 on page 7.
SECTION 1: HOME SCREEN
1 2
3
4
7
8
9
10 11
5
6
7SIGNATURE OPERATING MANUAL
SECTION 1: HOME SCREEN
Section 1.1 Temporary Bypass and Hold Options
If the thermostat is following the program/schedule (in Auto mode), you can temporarily bypass the programmed temperature by pressing the or button until the desired Set To temperature is displayed. The thermostat will maintain this temperature until the start of the next period.
Press Resume Program to cancel the temporary bypass.
Press Hold Options to access more options.
Hold Options
The Nuheat SIGNATURE thermostat allows you to set the duration you want to hold the temporary bypass temperature. Change the duration of the hold time by pressing the or arrows. Alternatively, press Permanent Hold to hold the temporary bypass temperature indefinitely.
Press Cancel to ignore the change or press Save to confirm.
On the home screen, press Resume Program to cancel the temporary bypass.
8 THERMAL BUILDING SOLUTIONS
SECTION 1: HOME SCREEN
Section 1.2 Energy Use
The Nuheat SIGNATURE thermostat tracks the amount of time your floor heating system has been heating.
Press Day/Week/Year to view the different time ranges.
Press Back to return to the home screen.
NOTE: The thermostat cycles the heating on and off to maintain the desired setpoint temperature. Actual heating time is normally a percentage of the scheduled ON time.
Section 1.3 Settings
The following options are available under the Settings menu:
• Setup/Preferences
• Program/Schedule
• WiFi Settings
• Weather Settings
• Thermostat Info
• Factory Reset
Example: Thermostat is programmed to turn on at 5:00pm and turn off at 8:00pm. The total ON time is 3 hours but the number of hours the system is actually HEATING may be a percentage of the total ON time.
Loading...
+ 16 hidden pages