Pentair NOCCHI SSH Owner's Manual

SSH
IT - ISTRUZIONI ORIGINALI IN LINGUA ITALIANA
1PAGE 33PAGE 49 65 81 97PAGE PAGE PAGE PAGED E NL RUSF17PAGEENIT
SUMMARY
CHAPTER DESCRIPTION PAGE
1.1 Documentation supplied 18
1.2 Ownership of information 18
1.3 Machine identification data 18
1.4 EC compliance declaration 18
1.5 General safety information 19
1 GENERAL INFORMATION
3 INSTALLATION
4 OPERATION
5 MAINTENANCE
6 OPERATING PROBLEMS Table 31
7 DEMOLITION
- PRODUCT SPECIFICATION - 113
- GARANZIA - 116
1.6 Conventions 21
1.7 Recommended use 21
1.8 Non recommended use 22
1.9 Warranty 23
1.10 Assistance 23
1.11 How to use the documentation supplied 23
2.1 Description 23
2.2 Technical characteristics 24
3.1 Lifting 24
3.2 Transportation 24
3.3 Storage 25
3.4 Preliminary inspections 25
3.5 Preparation of the installation site 25
3.6 Installations 27
4.1 Priming 28
4.2 Start-up 29
4.3 Checking the frequency of starts and stops 30
5.1 Lubrication 30
5.2 Temporary disabling 30
5.3 Periodical inspection 30
5.4 Extraordinary maintenance 31
7.1 Machine disabling 32
7.2 Residual risks after disabling 32
GB
17
GB
CHAPTER 1
GENERAL INFORMATION
1.1 DOCUMENTATION SUPPLIED
1.1.1 MANUAL
This manual is addressed to the operators responsible for operating the machine during all the technical stages of its life.
CONTENTS
This manual contains the following information:
• Manufacturer’s declaration
• Safety information
• Commercial information
• Information on documentation
Le informazioni sono suddivise nei seguenti capitoli e appendici di questo manuale:
• Chapter 1: General information
• Chapter 2: Description
• Chapter 3: Installation
1.2 OWNERSHIP OF INFORMATION
The information contained in this manual is property of PENTAIR INTERNATIONAL Sarl. It is forbidden to reproduce in whole or in part this manual without the explicit authorisation of PENT AIR INTERNATIONAL Sarl. The information contained in this manual is related only to the machines indicated in section “Product Specifications”. PENTAIR INTERNATIONAL reserves the right to make the changes deemed necessary to the machines not listed in the “Machine identification data”.
1.3 MACHINE IDENTIFICATION DATA
MACHINE CODE DESCRIPTION
DHR Horizontal multi-stage centrifugal electropump.
4- Rated flow rate m3/h
50 Number of stages x 10
1.4 EC COMPLIANCE DECLARATION
See page 2
• Machine description
• Transportation information
• Storage information
• Installation information
• Chapter 4: Operation
• Chapter 5: Maintenance
• Chapter 6: Operating problems
• Information on adjustments
• Operational information
• Maintenance information
• Dismantling information
• Chapter 7: Dismantling
• Appendix: Product specifications
18
1.5 GENERAL SAFETY INFORMATION
It is advisable to carefully follow the instructions contained in this manual with specific reference to notes, warnings and danger signs.
DANGER
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
WARNNG
Users should always follow the accident prevention laws in force in the country where the product is installed.
DANGER
Before repairing or servicing the electropump, disconnect it from the socket and/or turn the main switch to Off (when present) to interrupt the power supplied to the electropump. This prevents the electropump from accidentally restarting and from causing accidents to people and/or damages to the people.
DANGER
Do not service, install or move the electropump while it is powered, because these operations can cause serious accidents or even death.
WARNNG
During operation, do not remove or move the electropump.
DANGER
Before using the electropump, always check that the cable and all electric devices are efficient, shielded and protected.
DANGER
When starting the electropump (by inserting the plug into the socket and/or turning the main switch to on), always wear shoes and make sure that the hands are dry.
NOTE
Failure to follow the safety procedures and precautions contained in the documentation supplied shall relieve PENTAIR INTERNATIONAL from all liability thereof.
GB
19
GB
1.5.1 PERSONNEL QUALIFICATIONS
Qualification and protection limits established for operators
OPERATOR QUALIFICATION RECCOMENDED INDIVIDUAL PROTECTION MEAN
Knowledge and command of the chapters:
CARRIER
INSTALLER
USER
MAINTENANCE MAN
DEMOLISHER
• General information
• Description
• Installation
Qualification complying with the provisions of the Country of installation, knowledge and command of the chapters:
• General information
• Description
• Installation
Knowledge and command of the chapters:
• General information
• Description
• Use
Fitness acknowledged by PENTAIR INTERNATIONAL Sarl, knowledge and command of the chapters:
• General information
• Description
• Maintenance
Knowledge and command of the chapters:
• General information
• Description
• Dismantling
Protective shoes and gloves.
Protective shoes and gloves.
Protective shoes and gloves, high temperature protecting overall and gloves.
Protective shoes and gloves.
Protective shoes and gloves.
DANGER
The machine operates in safety conditions if it is used by qualified personnel in accordance with the instructions and information contained in this manual and present on board. All the operations referred to in this manual should be performed by qualified personnel equipped with the protection means described in this manual.
NOTE
PENTAIR INTERNATIONAL shall not be liable for accidents if the machine is used from non qualified or unauthorised personnel and originating from the failure to follow the instructions contained in this manual and present on the machine board.
20
1.5.2 SPECIAL MEASURES
The use of personnel with a qualification differing from the one indicated can endanger the safety of people and/or damage the property.
CONVENTIONS
1.6.1 TERMINOLOGICAL CONVENTIONS
The following conventions have been adopted throughout the manual
GB
• Machine: elettropompe specificate in
"Scheda prodotto"
1.6.2 TYPESETTING CONVENTIONS
DANGER
Le indicazioni di pericolo indicano quelle procedure la cui mancata o parziale osservanza può produrre danni fisici all'operatore.
WARNNG
Le indicazioni di attenzione indicano quelle procedure la cui mancata o parziale osservanza può produrre danni alla macchina o alle apparecchiature ad essa collegate.
NOTE
Le indicazioni di nota contengono delle informazioni, importanti, evidenziate al di fuori del testo a cui si riferiscono.
1.7 RECOMMENDED USE
1.7.1 RECOMMENDED USE
The machine has been designed, manufactured and protected to allow the transfer, circulation and increase of pressure of the following types of liquid:
• Water with temperature ranging
between +10 °C and 90 °C up to 6 bar, 50°C up to 10 bar
• Authorised technician:
person authorised by PENTAIR INTERNA TIONAL to perform even the operations not specifically indicated in this manual
• Fluids with a viscosity similar to
water, neutral and non-explosive fluids
• Specialised technician: person
authorised to perform even the operations not specifically indicated in this manual after being authorised by PENTAIR INTERNATIONAL
• The machine has been designed,
manufactured and protected to guarantee a flow rate of fluid that changes according to the desired head (see “Product specifications”)
21
Loading...