Pentair Nicheless Light AquaLumin II User Manual

16
1
AquaLumin® II - Nicheless Light
Installation Guide
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Section Contents
1. Installing a mounting bracket and light fixture during new vinyl pool construction...........3
2. Replacing light fixture in existing pools......................................................................7
3. Replacing a lamp only..............................................................................................10
Parts List / Replacement Part Kits........................................................................13-15
Minimum Qualifications
Licensed or Certified Electrician
Electrician or Qualified Pool Serviceman
Qualified Pool Serviceman or Homeowner
P/N 99460100 Rev E - 01/15/08
AquaLumin
®
II - Nicheless Light Installation Guide
IMPORTANT NOTICE
This AquaLumin II light will install only with the following AquaLumin II Mounting Brackets, manufactured after JUNE 6, 1994:
AquaLumin II Vinyl Mounting Bracket Assembly 1" (P/N 78887800)
AquaLumin II Vinyl Mounting Bracket Assembly 3/4" (P/N 78887700)
BACK VIEW
Housing spacer
Mounting spacer
Mounting bracket
AquaLumin II - Manufactured after June 6, 1994
P/N 99460100 Rev E - 01/14/08
AquaLumin® II - Nicheless Light Installation Guide
Housing
2
15
Technical Support
Contact Technical Support at:
Sanford, North Carolina (8 A.M. to 5 P.M.)
Moorpark, California (8 A.M. to 5 P.M.)
Phone: (800) 831-7133
Fax: (800) 284-4151
Web sites: visit www.pentairpool.com and www.staritepool.com
Replacement Part Kits
AquaLumin II Replacement Part Kits
Part Number Description
600140 Kwik change lens set
619613 - Green lens cover Qty. 1 619614 - Orange lens cover Qty. 1 619615 - Blue lens cover Qty. 1 619616 - Red lens cover Qty. 1
600138 Bulb replacement kit 120V / 250V
619484 - Bulb (120V/250W) Qty. 1 619599 - Lens gasket Qty. 1 619792 - Sealing screws Qty. 10
600139 Bulb replacement kit 12V / 100V
619584 - Bulb (12V/100W) Qty. 1 619599 - Lens gasket Qty. 1 619792 - Sealing screws Qty. 10
© 2008 Pentair Water Pool and Spa, Inc. All rights reserved
This document is subject to change without notice
1620 Hawkins Ave., Sanford, NC 27330 • (800) 831-7133 • (919) 566-8000 10951 West Los Angeles Ave., Moorpark, CA 93021 • (800) 831-7133 • (805) 553-5000
AquaLuminn Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Pentair Water Pool and Spa, Inc. disclaims proprietary interest in marks and names of others.
AquaLumin
®
II and the Pentair Water Pool and Spa
®
II - Nicheless Light Installation Guide
®
are registered trademarks of Pentair Water Pool and Spa, Inc.
600141 Le ns replacement kit
619797 - Lens Qty. 1 619599 - Lens gasket Qty. 1 619792 - Sealing screws Qty. 10
AquaLumin® II - Nicheless Light Installation Guide
14
1
2
3
5
6
4
3
Light Assembly Parts
Section 1: Installing a mounting bracket and light fixture during new vinyl
pool construction
D A N G E R !
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
This Nicheless light fixture must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock and may also cause damage to property. Always disconnect power to the pool light at the circuit breaker before servicing the light. Failure to do so could result in death or serious injury to serviceman, pool users or others due to electrical shock.
A. Preparatory steps which must be completed by the electrician before light is installed,
see Figure 1.
1. Be sure the electrical system of the pool conforms with the requirements of the current National Electrical Code (NEC) and all local codes and ordinances. A licensed or certified electrician must install the electrical system to meet or exceed those requirements before the Nicheless Light is installed. Some of the requirements of the NEC are listed below.
AquaLumin
Part
Item Number Description
1 619601 Face ring (white)
619632 Face ring (black) 2 619797 Lens 3 619599 Lens gasket 4 78889900 Captive screw 5* 619584 Halogen lamp 12 volt /100 watt
619484 Halogen lamp 120 volt / 250 watt 6 619792 Sealing screws (10 req.)
600140 Kwik change lens set (4) (not shown)
Note: (*) Sold in Bulb Replacement Kits 600139
and 600138.
®
II - Nicheless Light Installation Guide
AquaLumin II Replacement Parts
a. The lighting circuit must have a Ground Fault Circuit Interrupter (GFCI), and have an
appropriately rated circuit breaker.
b. The junction box (or, for
12 volt models, the low voltage transformer) is located at least 12 inches above water level, and at least 48 inches from the edge of the pool, see Figure 1.
c. The light fixture and all
metal items within five (5) feet of the pool must
TO GFCI, CIRCUIT BREAKER AND POWER SOURCE
RIGID CONDUIT
MOUNTING HUB
Figure 1
XISTING
TO E BONDING CONNECTOR
48"
MIN.
12" MIN. FROM BOTTOM OF JUNCTION BOX OR LOW VOLTAGE TRANSFORMER TO WATER LINE
WATER
18" MIN. FROM WATER TO TOP OF FACE RING
LEVEL
PILOT SCREW AT TOP
TOP OF FACE RING
SPONDS
CORRE TO CENTER OF MOUNTING HUB
be properly electrically bonded.
AquaLumin® II - Nicheless Light Installation Guide
Loading...