Pentair Nicheless Light AquaLumin II User Manual

Page 1
16
1
AquaLumin® II - Nicheless Light
Installation Guide
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Section Contents
1. Installing a mounting bracket and light fixture during new vinyl pool construction...........3
2. Replacing light fixture in existing pools......................................................................7
3. Replacing a lamp only..............................................................................................10
Parts List / Replacement Part Kits........................................................................13-15
Minimum Qualifications
Licensed or Certified Electrician
Electrician or Qualified Pool Serviceman
Qualified Pool Serviceman or Homeowner
P/N 99460100 Rev E - 01/15/08
AquaLumin
®
II - Nicheless Light Installation Guide
IMPORTANT NOTICE
This AquaLumin II light will install only with the following AquaLumin II Mounting Brackets, manufactured after JUNE 6, 1994:
AquaLumin II Vinyl Mounting Bracket Assembly 1" (P/N 78887800)
AquaLumin II Vinyl Mounting Bracket Assembly 3/4" (P/N 78887700)
BACK VIEW
Housing spacer
Mounting spacer
Mounting bracket
AquaLumin II - Manufactured after June 6, 1994
P/N 99460100 Rev E - 01/14/08
AquaLumin® II - Nicheless Light Installation Guide
Housing
Page 2
2
15
Technical Support
Contact Technical Support at:
Sanford, North Carolina (8 A.M. to 5 P.M.)
Moorpark, California (8 A.M. to 5 P.M.)
Phone: (800) 831-7133
Fax: (800) 284-4151
Web sites: visit www.pentairpool.com and www.staritepool.com
Replacement Part Kits
AquaLumin II Replacement Part Kits
Part Number Description
600140 Kwik change lens set
619613 - Green lens cover Qty. 1 619614 - Orange lens cover Qty. 1 619615 - Blue lens cover Qty. 1 619616 - Red lens cover Qty. 1
600138 Bulb replacement kit 120V / 250V
619484 - Bulb (120V/250W) Qty. 1 619599 - Lens gasket Qty. 1 619792 - Sealing screws Qty. 10
600139 Bulb replacement kit 12V / 100V
619584 - Bulb (12V/100W) Qty. 1 619599 - Lens gasket Qty. 1 619792 - Sealing screws Qty. 10
© 2008 Pentair Water Pool and Spa, Inc. All rights reserved
This document is subject to change without notice
1620 Hawkins Ave., Sanford, NC 27330 • (800) 831-7133 • (919) 566-8000 10951 West Los Angeles Ave., Moorpark, CA 93021 • (800) 831-7133 • (805) 553-5000
AquaLuminn Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Pentair Water Pool and Spa, Inc. disclaims proprietary interest in marks and names of others.
AquaLumin
®
II and the Pentair Water Pool and Spa
®
II - Nicheless Light Installation Guide
®
are registered trademarks of Pentair Water Pool and Spa, Inc.
600141 Le ns replacement kit
619797 - Lens Qty. 1 619599 - Lens gasket Qty. 1 619792 - Sealing screws Qty. 10
AquaLumin® II - Nicheless Light Installation Guide
Page 3
14
1
2
3
5
6
4
3
Light Assembly Parts
Section 1: Installing a mounting bracket and light fixture during new vinyl
pool construction
D A N G E R !
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
This Nicheless light fixture must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock and may also cause damage to property. Always disconnect power to the pool light at the circuit breaker before servicing the light. Failure to do so could result in death or serious injury to serviceman, pool users or others due to electrical shock.
A. Preparatory steps which must be completed by the electrician before light is installed,
see Figure 1.
1. Be sure the electrical system of the pool conforms with the requirements of the current National Electrical Code (NEC) and all local codes and ordinances. A licensed or certified electrician must install the electrical system to meet or exceed those requirements before the Nicheless Light is installed. Some of the requirements of the NEC are listed below.
AquaLumin
Part
Item Number Description
1 619601 Face ring (white)
619632 Face ring (black) 2 619797 Lens 3 619599 Lens gasket 4 78889900 Captive screw 5* 619584 Halogen lamp 12 volt /100 watt
619484 Halogen lamp 120 volt / 250 watt 6 619792 Sealing screws (10 req.)
600140 Kwik change lens set (4) (not shown)
Note: (*) Sold in Bulb Replacement Kits 600139
and 600138.
®
II - Nicheless Light Installation Guide
AquaLumin II Replacement Parts
a. The lighting circuit must have a Ground Fault Circuit Interrupter (GFCI), and have an
appropriately rated circuit breaker.
b. The junction box (or, for
12 volt models, the low voltage transformer) is located at least 12 inches above water level, and at least 48 inches from the edge of the pool, see Figure 1.
c. The light fixture and all
metal items within five (5) feet of the pool must
TO GFCI, CIRCUIT BREAKER AND POWER SOURCE
RIGID CONDUIT
MOUNTING HUB
Figure 1
XISTING
TO E BONDING CONNECTOR
48"
MIN.
12" MIN. FROM BOTTOM OF JUNCTION BOX OR LOW VOLTAGE TRANSFORMER TO WATER LINE
WATER
18" MIN. FROM WATER TO TOP OF FACE RING
LEVEL
PILOT SCREW AT TOP
TOP OF FACE RING
SPONDS
CORRE TO CENTER OF MOUNTING HUB
be properly electrically bonded.
AquaLumin® II - Nicheless Light Installation Guide
Page 4
4
( & )
13
Section 1: Installing a mounting bracket and light fixture during new vinyl
pool construction (Continued)
d. The mounting bracket and mounting hub must be
properly installed so that the top edge of the face ring of the Nicheless Light is at least 18 inches below the surface of the water in the pool. The top of the face ring will line up with the center of the Plastic Mounting Hub, see Figure 1 on page 3.
e. The mounting bracket (not shown) and mounting hub
must be properly electrically bonded and grounded via the No. 8 AWG ground connector located at the upper left mounting bolt positioned, see Figure 2.
2. To be certain that the pool's electrical system meets all applicable requirements, you should also consult the local
building department.
3. Use only Pentair Nicheless Fixtures, (Mounting Bracket Assembly), to ensure proper bonding and grounding connections.
B. Perform the following steps after the electrical system requirements are met
(see Section 1A (page 3) for requirements)
Figure 2
Vinyl Liner Mounting Bracket Parts
Patent Number 5,051,875
Models 250 watt / 120 volt and
100 watt / 12 volt (transformer required)
1. Locate position on a vertical wall where light is to be installed. The top of the light face ring must be 18 inches below normal water level as required by NEC Article 680.
2. Cut or punch a three (3) inch diameter hole through pool wall with center 18 inches below normal water level for mounting hub and mounting bracket installation.
3. If using plastic conduit, install PVC conduit adapter (provided) before installing plastic mounting hub. Use only recommended sealant for PVC/ABS threads. Position mounting hub over hole with the word “TOP” at the top, and secure with mounting flange and two (2) hex nuts and lock washers. Tighten hex nuts evenly with equal torque.
NOTE: Attach the stainless steel mounting bracket temporarily to ABS mounting hub. Perfect top and bottom alignment of ABS hub will be easier.
CAUTION: Remove mounting bracket before liner is installed. Failure to remove mounting bracket can damage the liner during installation.
AquaLumin
®
II - Nicheless Light Installation Guide
Vinyl Liner Replacement Parts
Part
Item Number Description
1 619547 Wall mounting bracket assembly
2 619548 Metal bracket cup assembly
3 619549 Mounting hub 3/4 in. assembly
4 619550 Mounting hub 1 in. assembly 5 78872600 Mounting spacer 6 619617 Housing spacer 7 86001800 Nipple, 1 in.
AquaLumin® II - Nicheless Light Installation Guide
Page 5
12
5
Section 3: Replacing a lamp only (Continued)
13. While holding the glass lens and plastic face ring, turn the light over and place it face down on a flat soft clean surface. Be careful not to scratch the lens.
14. Insert one new sealing screw, provided with the Bulb Replacement Kit, through the circular hole located at the TOP (12 o'clock) of the back of the housing and loosely tighten it into the face ring. Insert the remaining new sealing screw through the circular hole located at the BOTTOM (6 o'clock) of the back of the housing and loosely tighten it into the face ring. The BOTTOM (6 o'clock) circular hole is accessible through a hole drilled in the center of the hook mounting bracket.
15. Continue to tighten all the sealing screws into the face ring. It is recommended that opposing sealing screws be tightened in order (12 o'clock and 6 o'clock; 3 o'clock and 9 o'clock, etc.) to the recommended torque of 10-15 in-lbs. This provides even pressure on the lens and lens gasket and creates a seal between the environment and the inside of the light fixture.
16. Wrap a length of the cord up to a maximum of eight (8) feet long on the back of the light assembly. Wind a maximum of three (3) wraps of cord so that the last wrap stops at the top of the light. This extra cord allows the light to be brought out of the pool for servicing.
NOTE: Leave 2" to 3" of slack cord at the top so that the light may be tipped back for removal.
WARNING Always install a new lens gasket, part number 619599, whenever
reassembling the light. Failure to do so may permit water to leak into the assembly which could cause; (a) an electrical hazard resulting in death or serious injury to pool users, installer, or others due to electrical shock, or (b) breakage of the lamp or lens, which likewise could result in serious injury to pool user, installers, or bystanders, or in damage to property.
17. Feed the remaining cord through the conduit hole in the mounting hub. Place the hook mounting bracket over the pin on the bottom of the mounting bracket. Press down lightly to secure in place. Secure at the top of the light with the captive screw.
18. Before operating the light for more than 10 seconds, be sure the Nicheless Light is completely submerged in water. To check for proper operation, switch on the main switch
or circuit breaker, as well as the switch which operates the Nicheless Light.
Section 1: Installing a mounting bracket and light fixture during new vinyl
pool construction (Continued)
4. Connect bonding wire from bonding grid to bonding lug on rear of the mounting hub assembly.
5. Before installing liner, be sure gasket is firmly attached to mounting hub. After liner is installed and properly stretched into position, locate bolt holes in hub and punch liner for four bracket mounting bolts. Install the mounting spacer against the liner and hold in position with mounting bracket. Secure with four (4) bracket mounting bolts and washers.
NOTE: If using PVC conduit, you must attach grounding wire to grounding lug on upper left mounting bolt positioned, see Figure 4, on page 6.
6. Wrap a length of the cord up to a maximum of eight (8) feet long on the back of the light assembly. Wind a maximum of three (3) wraps of cord so the last wrap stops at the top of the light. This extra cord allows you to bring the light out of the pool to install a new lamp and for servicing.
NOTE: Leave 2" to 3" of slack cord at the top so that the light may be tipped back for removal.
7. Feed the remaining cord through the conduit hole in the mounting hub. Place hook mounting bracket over the pin on the bottom of the mounting bracket and press down lightly to secure in place. Secure at the top of the light with the captive screw. When installed properly, the housing spacer should fill any gap between the pool wall and the light.
Figure 3.
AquaLumin
WARNING Use only the special stainless steel captive screw (see Light Assembly Parts, item 4, on page 14) provided with this Nicheless Light. This screw
mounts and electrically grounds the housing securely to the Nicheless fixture. Failure to use the screw provided could create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock.
®
II - Nicheless Light Installation Guide
NOTE: If PVC conduit is being used, a #8 ground wire for U.L. or a #6 ground wire for CSA, must be pulled through the conduit along with the light cord and fastened at the junction box and at the grounding lug located on the light wall Mounting Bracket (the Upper left bracket mounting bolt).
AquaLumin® II - Nicheless Light Installation Guide
Page 6
6
11
Section 1: Installing a mounting bracket and light fixture during new vinyl
pool construction (Continued)
8. Cut the cord at the junction box, leaving at least six (6) inches of cord to make connections.
9. Strip 6 inches of the outer cord jacket to expose the three insulated wires. Be careful not to damage the insulation on the three inner wires.
10. Connect cord to electrical wires at Junction Box, be careful to not pull the three (3) in. of slack cord at the light through the conduit when connecting the wires. All wiring should be connected to a Class A Ground Fault Circuit Interrupter (GFCI), in accordance with electrical codes, see Section 1.A.1.a on page 3.
11. Connect all three wires to the corresponding circuit wires in the junction box and secure the junction box cover in place.
WARNING: Never operate this Nicheless Light for more than 10 seconds unless it is totally submerged in water. Without total submersion, the light assembly will get extremely hot, which may result in serious burns or in breakage of the lamp or lens. This may result in serious injury to pool users, installer, or bystanders, or in damage to property.
WARNING: Use only the special stainless steel captive screw (see Light
Assembly Parts, item 4, on page 14) provided with this Nicheless Light. This screw
mounts and electrically grounds the housing securely to the Nicheless fixture. Failure to use the screw provided could create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock.
Section 3: Replacing a lamp only (Continued)
WARNING: Be sure power is OFF before installing or removing lamp. Allow lamp to cool
before relamping. This light fixture uses a Halogen Quartz lamp. Do Not touch lamp with bare hands, this may severely reduce its life. Use the plastic furnished with the replacement lamp to eliminate finger prints from getting on lamp.
8. To remove the lamp:
a. Place the light in front of you so that the captive screw hole is at the top, and the lamp
is in a horizontal position.
b. Grasp the lamp on the right side.
c. Push the lamp to the left, compressing the spring in the spring loaded lamp socket,
until the right side of the lamp comes free from the fixed socket end.
9. Install the new lamp by performing step 8, a through c, in reverse order. NOTE: Select proper lamp for either 12 volt or 120 volt applications. Take care not to touch the halogen bulb with bare hands.
WARNING Always install a new lens gasket, part number 619599, whenever
reassembling the light. Failure to do so may permit water to leak into the assembly which could cause; (a) an electrical hazard resulting in death or serious injury to pool users, installer, or others due to electrical shock, or (b) breakage of the lamp or lens, which likewise could result in serious injury to pool user, installers, or bystanders, or in damage to property.
10. Never reuse the old lens gasket when reassembling the light. Replace the old lens gasket with a new genuine Pentair Water AquaLumin II lens gasket (P/N 619599), provided in the Bulb Replacement Kit. The orientation of the tabs on the lens gasket is not important.
Figure 4.
12. Before operating the light for more than 10 seconds, fill pool until the Nicheless Light is completely submerged in water. To check for proper operation, turn on main switch or circuit breaker, as well as the switch which operates the Nicheless Light.
C. Winterizing: Light should be left in place for winterization.
AquaLumin
®
II - Nicheless Light Installation Guide
11. Replace the eight (8) sealing screws left in the face ring with eight (8) new sealing screws provided in the Bulb Replacement Kit. NOTE: Install the new sealing screws in the same location as those removed, leaving "TOP" (12 o'clock) and "BOTTOM" (6 o'clock) open.
12. Reinstall the lens gasket, lens and plastic face ring. While replacing the lens, be sure the tabs around the perimeter of the lens gasket are not under the flange of the lens. Orientate the lens so that the word "TOP" is aligned with the captive screw hole. When reinstalling the plastic face ring, align the heads of the sealing screws with the large circular holes of the keyway slots. Press down on the plastic face ring and rotate in the clockwise direction until the sealing screws interfere with the housing (at the end of the slot). Orientate the plastic face ring so that the words "MADE IN USA" are aligned with the captive screw hole on the housing as well as the word "TOP" on the lens.
AquaLumin® II - Nicheless Light Installation Guide
Page 7
10
7
Section 3: Replacing a lamp only
The following steps may be performed by a qualified pool serviceman or a homeowner.
NOTE: Use ONLY the Pentair Bulb Replacement Kit when relamping (P/N 600139 - 12V/100W or P/N 600138 - 120V/250W). See relamping installation instructions provided with the light.
WARNING Never operate this Nicheless Light for more than 10 seconds unless it is totally submerged in water. Without total submersion, the light assembly will get extremely hot, which may result in serious burns or in breakage of the lamp or lens. This may result in serious injury to pool users, installer, or bystanders, or in damage to property.
WARNING Use only the special stainless steel pilot screw (see Light Assembly Parts, item 4, on page 14) provided with this Nicheless Light. This screw mounts and electri-
cally grounds the housing securely to the Nicheless fixture. Failure to use the screw provided could create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock.
D A N G E R !
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
Always disconnect power to the pool light at the circuit breaker before servicing the light. Failure to do so could result in death or serious injury to installer, serviceman, pool users, or others due to electrical shock.
1. Turn off main electrical switch or circuit breaker as well as the switch which operates the Nicheless Light.
2. Unscrew the captive screw on the top of the light, then tilt the top of the light out from the wall and lift the bottom of the light out of the bracket. Unwind the excess cable that is stored in the back of the light.
3. Place the light face down on the deck on a flat soft clean surface. Take care not to scratch the lens.
4. Using a Phillips head screwdriver, loosen (do not remove) all ten 10 screws on the back of the light.
5. Using a Phillips head screwdriver, remove the two (2) screws located at the TOP (12 o'clock) and BOTTOM (6 o'clock) on the back of the light.
6. While holding the glass lens and plastic face ring, turn the light over. Rotate the face ring in a counter-clockwise direction such that the heads of the sealing screws align with the large circular holes of the keyways slots. Lift the plastic face ring away from the housing to remove the lens and lens gasket.
7. To remove the lens and lens gasket, gently pull on the tabs located around the perimeter of the lens gasket. This will allow air to enter the housing and will assist with removal of the lens.
AquaLumin
®
II - Nicheless Light Installation Guide
Section 2: Replacing light fixture in existing pools
WARNING: Use only the special stainless steel captive screw (see Light Assembly Parts, item 4, on page 14) provided with this Nicheless Light. This screw
mounts and electrically grounds the housing securely to the Nicheless fixture. Failure to use the screw provided could create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock.
IMPORTANT NOTICE This AquaLumin II light will install only with the following AquaLumin II Mounting Brackets, manufactured after JUNE 6, 1994.
D A N G E R !
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION
This Nicheless light fixture must be installed by a licensed or certified electrician or a qualified pool serviceman in accordance with the National Electrical Code and all applicable local codes and ordinances. Improper installation will create an electrical hazard which could result in death or serious injury to pool users, installers or others due to electrical shock and may also cause damage to property. Always disconnect power to the pool light at the circuit breaker before servicing the light. Failure to do so could result in death or serious injury to serviceman, pool users or others due to electrical shock.
Description Part Number
AquaLumin II Vinyl Mounting Bracket Assembly 1" 78887800 AquaLumin II Vinyl Mounting Bracket Assembly 3/4" 78887700
A. The following are preparatory steps which must be completed by the electrician or
qualified pool serviceman before replacing light fixture, see Figure 5 on page 8.
1. Verify the pool meets the requirements of the current National Electrical Code and all local
codes and ordinances. A licensed or certified electrician must install the electrical system to meet or exceed those requirements before the Nicheless Light is installed. Some of the requirements of the National Electrical Code which the pool's electrical system must meet are as follows:
a. The lighting circuit must have a Ground Fault Circuit Interrupter (GFCI), and an
appropriately rated circuit breaker.
AquaLumin® II - Nicheless Light Installation Guide
Page 8
8
9
Section 2: Replacing light fixture in existing pools (Continued)
b. The junction box, or the low voltage transformer for 12 volt models, is located at least
12 inches above water level and at least 48 inches from the edge of the pool, see Figure 5.
c. The light fixture and all metal items within five (5) feet of the pool must be properly
electrically bonded.
d. The mounting bracket must be properly installed so that the top edge of the face ring
of the Nicheless Light is at least 18 inches below the surface of the water in the pool, see Figure 5.
e. The mounting bracket and mounting hub must be properly electrically bonded and
grounded via the No. 8 AWG ground connector located at the rear of the Nicheless fixture, see Figure 5.
2. Consult the local building department to be certain that the pool's electrical system meets all applicable requirements.
3. Install this light fixture only in a Pentair Products mounting bracket. Mounting brackets made by other manufacturers may not provide proper bonding and grounding connections.
TO GFCI, CIRCUIT BREAKER AND POWER SOURCE
RIGID CONDUIT
MOUNTING HUB
Figure 5
TO EXISTING BONDING CONNECTOR
48"
MIN.
12" MIN. FROM BOTTOM OF JUNCTION BOX OR LOW VOLTAGE TRANSFORMER TO WATER LINE
WATER LEVEL
18" MIN. FROM WATER TO TOP OF FACE RING
PILOT SCREW AT TOP
TOP OF FACE RING CORRESPONDS TO CENTER OF MOUNTING HUB
Section 2: Replacing light fixture in existing pools (Continued)
B. Replacing light fixture after electrical system requirements are met
1. Turn off main electrical switch or circuit breaker, as well as the switch which operates the Nicheless Light.
WARNING: Failure to bring the pool's electrical system up to code requirements before installing this Nicheless Light will create an electrical hazard which could result in death or serious injury to pool users, installers, or others due to electrical shock, and may also cause damage to property.
2. To remove light assembly, remove captive screw at top of housing, remove light assembly from mounting bracket, and place assembly on deck. Take care not to scratch the lens.
3. Remove junction box cover, disconnect the light fixture wires, and pull the cord through the conduit.
4. Feed the new light fixture cord through the conduit from the Nicheless Fixture to the junction box.
NOTE: Depending on the length of the conduit, special tools may be required to pull the cord through the conduit.
5. Wrap a length of the cord up to a maximum of eight (8) feet long on the back of the light assembly. Wind a minimum of three (3) wraps of cord so that the last wrap stops at the top of the light. This extra cord allows you to bring the light out of the pool for installation of a new lamp and for servicing.
NOTE: Leave 2" to 3" of slack cord at the top so that the light may be tipped back for removal.
6. Feed the remaining cord through the conduit hole in the mounting hub. Place hook mounting bracket over pin on the bottom of the mounting bracket and press down lightly to secure into place. Secure at top of the light with the captive screw.
7. Cut the cord at the junction box, leaving at least six (6) inches of cord to make connections.
8. Strip six (6) inches of the outer cord jacket from the cord to expose the three insulated wires. Be careful not to damage the insulation on the three inner wires.
9. Connect cord to electrical wires at Junction Box, be sure not to pull the three (3) inches of slack cord at the back of the light through the conduit when connecting the wires. All wiring should be connected to a Class A GFCI in accordance with electrical codes, see Section
2.A.1.a on page 7.
10. Connect all three wires to the corresponding circuit wires in the junction box and secure the junction box cover in place.
11. Before operating the light for more than 10 seconds, fill pool until the Nicheless Light is completely submerged in water. To check for proper operation, turn on main switch or circuit breaker, as well as the switch which operates the Nicheless Light.
AquaLumin
®
II - Nicheless Light Installation Guide
AquaLumin® II - Nicheless Light Installation Guide