Pentair KX-HCM110A, BL-C1A, BB-HCM381A, BB-HCM331A, BL-C111A User Manual

...
ScreenLogic
Video & Lighting Protocol
Adapter
®
User’s and Installation Guide
ScreenLogic Video & Lighting Protocol Adapter Users and Installation Guide
i
ScreenLogic® Video & Lighting Protocol Adapter kit contents
The following items are included in the kit.
Kit contents
ScreenLogic Video & Lighting Protocol Adapter (P/N 520854Z)
AC/DC power adapter
RJ45 cable
DB9M to RJ45 adapter
User’s and Installation Guide (this manual)
Technical Support
Sanford, North Carolina (8 A.M. to 5 P.M. ET) Moorpark, California (8 A.M. to 5 P.M. PT)
Phone: (800) 831-7133 - Fax: (800) 284-4151
Related manuals - Download the IntelliTouch ScreenLogic User’s Guide (P/N 520493) at:
http://www.pentairpool.com/siteimages/ScreenLogic_Users_Guide.pdf
FCC Regulatory Safety Notice - This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
• Modifications not expressly approved by the party responsible for FCC compliance could void the user’s authority to operate the equipment.
IC Regulatory Notice
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
© 2008 Pentair Water Pool and Spa, Inc. All rights reserved.
1620 Hawkins Ave., Sanford, NC 27330 • (919) 566-8000 10951 West Los Angeles Ave., Moorpark, CA 93021 • (800) 553-5000
IntelliTouch®, ScreenLogic® and Pentair Water Pool and Spa® are registered trademarks of Pentair Water Pool and Spa, Inc. and/or its affiliated companies in the United States and/or other countries. Unless noted, names and brands of others that may be used in this document are not used to indicate an affiliation or endorsement between the proprietors of these names and brands and Pentair Water Pool and Spa, Inc. Those names and brands may be the trademarks or registered trademarks of those parties or others.
P/N 520936 - Rev A - 03/03/2008
ScreenLogic Video & Lighting Protocol Adapter User’s and Installation Guide
Contents
ScreenLogic Video and Lighting Protocol Adapter Connection Diagram. 2
Connecting the ScreenLogic Video & Lighting Protocol Adapter ............ 3
Installing the ScreenLogic Video & Lighting protocol adapter................. 4
Configuring the System ....................................................................... 5
Configuring the Video Camera(s) for the first time ................................ 6
Using the Video Camera Interface ......................................................... 9
Installing the Lights for the first time ................................................... 10
Using the Lights Interface ................................................................... 13
ScreenLogic Video & Lighting Protocol Adapter
Using the SceenLogic Video & Lighting Protocol adapter with your existing ScreenLogic system you can control up to four color video cameras to monitor your pool/spa and home areas via your ScreenLogic interface device or PC at home or remotely over the Internet. Also, using a Lighting Powerline Interface Module you can control any number of outside and inside lights.
Features:
Remotely monitor your property via video cameras
Control outside lights (pathway, front door, entry hallway, stairwells, garage entryway, etc.)
Control lights inside the home
Log on anywhere via your laptop or PC for full control
Compatible with all IntelliTouch systems
Supported Video Cameras and Light Switches
The following video camera models and Powerline Control systems are supported for use with the ScreenLogic Video & Lighting Protocol adapter:
1
- Panasonic video camera Models: BL-C1A, BL-C111A, BB-HCM311A,
BB-HCM331A, KX-HCM110A, BB-HCM381A
Note: Panasonic video cameras are widely available for sale on the Internet
- Powerline Control Systems, PulseWorx PCS models:
Note: PCS light switches * are compatible with incondescent light bulbs only. Lights with florescent light bulbs cannot be used.
Powerline Interface Module (PIM) - Model PIM-R (Serial Interface)
Note: (*) PCS light switches are widely available on the Internet. Refer to the following links: http://www.hometech.com/brains/upb.html#PO-PIMR
http://www.hometech.com/modules/upb.html#PO-WS1D6W
ScreenLogic Video & Lighting Protocol Adapter User’s and Installation Guide
Wall Switch Dimmer (600W)
Model # WS1D6
2
ScreenLogic Video and Lighting Protocol Adapter Connection Diagram
ScreenLogic Video
& Lighting Protocol
Existing ScreenLogic
Protocol Adapter
(Pentair Brick: xx-xx-xx)
COM 1
LAN
Adapter
AC Power
adapter
Powerline
WAN
234 1
Camera
Router
Wireless
ScreenLogic
234 1
For additional cameras
(max qty. 4) an optional
Network switch is
required.
ScreenLogic Video & Lighting Protocol Adapter User’s and Installation Guide
Interface
Module
compatible with
switches are
Note: PSC light
DB9M / RJ45
PCS Light switch(s) found
around the home
used.
bulbs cannot be
florescent light
Lights with
light bulbs only.
incondescent
Connecting the ScreenLogic Video & Lighting Protocol Adapter
The following describes how to connect the Video & Lighting Protocol adapter to an existing ScreenLogic system.
1. Connect the provided RJ45 (CAT5) cable to an available port (1, 2, 3, or 4) on the ScreenLogic wireless router. Connect the other end of the cable to the LAN port on the Video & Lighting Protocol adapter (see diagram on page 2).
2. Lights cable connection: Connect an RJ45 (CAT5) cable to the COM 1 port on the adapter. Connect the other end of the cable to the DB9M/RJ45 adapter. Connect the DB9M/RJ45 adapter to the RS-232 connector that is connected to the UPB Powerline Interface Module (PIM). See diagram on page 2.
3. Camera cable connection: Connect AC power plug to the video camera(s). Connect the RJ45 camera cable to port 1, 2, 3, or 4 on the ScreenLogic wireless router (see diagram on page 2).
If additional cameras are being installed, a Network Switch can be used to provide available ports. ScreenLogic supports a maximum of four cameras (see diagram on page 2).
ScreenLogic Video & Lighting Protocol Adapter Name
The Video & Lighting Protocol adapter system name is identified on the screen as: Pentair: xx-xx-xx (where xx-xx-xx are the last six (6) digits of the unit’s serial number which can be found on a sticker on the adapter). The name is displayed on the ScreenLogic Connect dialog as shown below:
3
Check this box to save the
current login information
Pentair Brick
(192.168.2.2.:80) is the
existing ScreenLogic
Protocol Adapter IP address.
Do not configure this
adapter.
ScreenLogic Video & Lighting
Protocol Adapter name
ScreenLogic Video & Lighting Protocol Adapter User’s and Installation Guide
Loading...
+ 11 hidden pages