Pump System Installation and Service Manual
118-5 SYSTEM
Sump Pump Hide-Away Basin System
(14.5" W, 16" H, 1.5" Discharge Opening)
NOTE! To the installer: Please make sure you provide this manual to the owner of the pumping equipment or to the responsible party who maintains the system.
Page 2
General Information
Thank you for purchasing your Hydromatic years of trouble-free operation, please read the following manual carefully.
®
product. To help ensure
trays, washing machines, wet bars, water softeners, dehumidifiers, etc. This pump system installs above floor level, no need to dig a sump! This pump system cannot be used for laundry/dishwasher applications in a commercial or industrial environment.
using 1-1/2" or 1-1/4" PVC pipe on the discharge line, a Hydromatic CV-170 check valve is recommend­ed. Once check valve has been installed, plumb the discharge line into an existing drain line.
Basin:
Before operation:
Read the following instructions carefully. Reasonable care and safe methods should be practiced. Check local codes and requirements before installation.
Attention:
This manual contains important information for the safe use of this product. Read this manual completely before using this product and refer to it often for continued safe product use. DO NOT THROW AWAY OR LOSE THIS MANUAL. Keep it in a safe place so that you may refer to it often.
Warning:
Before handling these pumps and controls, always disconnect the power first. Do not smoke or use sparkable electrical devices or flames in a septic (gaseous) or possible septic sump.
Installation Instructions
Diagram 1 shows the various connections that must be made for proper installation and operation. This is only a guide; actual installation may vary depending on the particular situation.
Inlet:
A 1-1/2" inlet is provided on the 118-5 Hide-Away Basin System. One method of hookup is to use a 1-1/2" PVC MIP adapter or a 1-1/2" PVC MIP marvel connection (or a similar type of connection). You may use a 1-1/2" extension tailpiece or 1-1/2" PVC pipe; it depends on the type of fittings used on the basin inlet. The P-Trap should be installed once the appropriate connections are made on the basin inlet. Once these fittings are installed the rest of the piping may be plumbed.
Hydromatic’s 118-5 Hide-Away Basin System includes a corrosion­resistant polypropylene tank with a gasket cover. An inlet strainer is pro­vided in the basin cover above the inlet. The strainer is sealed and held in place with the four screws provided.
System Maintenance
Caution:
Always disconnect pump from the electrical power source before doing any maintenance. Your sink pump system is manufactured for easy maintenance. Each unit is individually factory-tested to ensure proper adjustment and operation. If unit fails to operate properly, carefully read instructions again to make sure correct procedure has been followed.
Pump Warning
Warranty void if product is modified, drilled, painted, or altered in any way; if used to pump hot water, or to pump liquids other than water (such as but not limited to chemicals, fertilizers, flammable liquids, herbicides, mud, tar, cement, wood chips); or otherwise abused.
The model 118-5 Hide-Away Basin System is specially designed for pumping wastewater from laundry
Vent:
Provision has been made for a 2" vent to allow maximum volume for any application and proper operation of pump. The vent may be reduced to no less than 1-1/4". Venting is essential for proper pump operation and should not be omitted. The 118-5 Hide-Away Basin System may be vented into an existing vent stack or use a BOCA in­line vent. Check local codes.
Discharge:
Do not restrict discharge line below 1-1/4". A check valve MUST be installed to prevent backflow of water after each cycle. If you are
Electrical Information
Note: The basin strainer requires routine maintenance. The strainer should be removed and cleaned monthly to prevent clogging.
WARNING! Risk of electrical shock. This pump is supplied with a grounding conductor and grounding type attachment plug. To reduce risk of electrical shock, connect only to a properly grounded grounding-type receptacle. This pump has not been investigated for use in swimming pool areas.
Page 3
DO NOT WORK ON PUMP
Inlet Pipe
and Trap
(not supplied)
Laundry Tray Wet Bar Dehumidifier Water Softener Washing Machine etc. (not supplied)
Pump, Switch and
Internal Piping
Tank
Gas-tight
Cover
Discharge Pipe
and Check Valve
(not supplied)
Vent Pipe
(not included)
Inlet Opening
Discharge Opening
Clean-out Filter
Vent
Opening
Pipe
Included
1
1
/2"
1
1
/2"
14
1
/2"
2"
11"
16"
UNTIL POWER IS UNPLUGGED.
DO NOT cut off ground pin or use an adapter fitting. DO NOT use an extension cord. The pump power cord should be connected to a separately fused, grounded 115 volt line with a minimum capacity of 15 amps. NEVER touch the pump when it is connected to electrical power.
The receptacle should be located at least 4 feet above floor level. When wiring this pump follow all local electrical and safety codes and ordinances as well as the most recent National Electrical Code. N.E.C., ANSI/NFPA 70 - 2000.
118-5 Parts List
Ref. No. Description Part No. Qty.
1 BASIN, SINK TANK 25530C000 1 2 BV-A1, SUMP PUMP 52623-000-1 1 3 COVER, SINK BASIN 25540C001 1 4 GASKET, COVER 23150074000 3.38 5 SCREW, 10-32 X 3/4" PANHEAD PHILLIPS 05434A061 8 6 COVER, SINK TANK STRAINER 25686A000 1 7 GASKET, STRAINER 25688B000 1 8 STRAINER 25685A000 1
9 FASTENERS, 1/4-20 X 5/8" 18475A007 4 10 PIPE, 1-1/2 X 12" TOE 13665-018-3 1 11 GROMMET, ELECTRICAL 25689A000 1 12 NAMEPLATE 14849-000-1 1 13 LABEL, WARNING 14848-000-1 1 14 CARTON 14851-000-1 1
Diagram 1
Page 4
WARRANTY
Hydromatic
®
warrants to the original purchaser of each Hydromatic product(s) that any part thereof that proves to be defective in material or workmanship within one year from date of installation or 18 months from manufacture date, whichever comes first, will be replaced at no charge with a new or remanufactured part, F.O.B. factory. Purchaser shall assume all responsibility and expense from removal, reinstallation and freight. Any item(s) designated as manufactured by others shall be covered only by the express warranty of the manufacturer thereof. This warranty does not apply to damage resulting from accident, alteration, design, misuse or abuse. The pump must be installed, operated and maintained in accordance with the published instructions of the appropriate Installation & Service Manual.
All dual seal non-clogs and 3–5 HP grinders must have seal failure and heat sensors attached and functional for Warranty to be in effect. If a seal failure should occur, Hydromatic will cover only the lower seal and labor thereof. Labor is based on Authorized Service Center contract allowance. If the heat sensor is not attached and functional, Warranty is void. If the seal failure sensor is not attached and functional, Warranty is void.
If the material furnished to the Buyer shall fail to conform to this contract or to any of the terms of this written warranty, Hydromatic shall replace such nonconforming material at the original point of delivery and shall furnish instruction for its disposition. Any transportation charges involved in such disposition shall be for the Buyer’s account. The Buyer’s exclusive and sole remedy on account or in respect of the furnishing of material that does not conform to this contract or to this written warranty, shall be to secure replacement thereof as aforesaid. Hydromatic shall not in any event be liable for the cost of any labor expended on any such material or for any incidental or consequential damages to anyone by reason of the fact that such material does not conform to this contract or to this written warranty.
ALL IMPLIED WARRANTIES, INCLUDING THE IMPLIED WARRANTY OF MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, ARE DISCLAIMED TO THE SAME EXTENT AS THE EXPRESS WARRANTY CONTAINED HEREIN. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you.
MANUFACTURER EXPRESSLY DISCLAIMS AND EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ARISING IN CONNECTION WITH THIS PRODUCT, INCLUDING WITHOUT LIMITATION, WHETHER IN TORT, NEGLIGENCE, STRICT LIABILITY CONTRACT OR OTHERWISE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
– Your Authorized Local Distributor –
USA
740 East 9th Street, Ashland, Ohio 44805
Tel: 419-289-3042 Fax: 419-281-4087
© 2007 Hydromatic®Ashland, Ohio. All Rights Reserved.
www.hydromatic.com
269 Trillium Drive, Kitchener, Ontario, Canada N2G 4W5
Tel: 519-896-2163 Fax: 519-896-6337
CANADA
Item # E-03-423 5/07Part # 5625-423-1