Pentair HLTSTAT10C, HLTSTAT20C Instruction Manual

© 2016 Pentair Equipment Protection 89115889Rev. E P/N 89115890© 2016 Pentair Equipment Protection 89115889Rev. E P/N 89115890
Hazardous Location Heaters
Thermostat
INSTRUCTION MANUAL
© 2016 Pentair Equipment Protection
- 2 -
NOTE: The respective operating instructions must be observed. For EC Type Examination Certificate PTB 03 ATEX 1136X and IEC Scheme Certificate IECEX PTB 07.0054X, see www.pentairprotect.com.
TABLE OF CONTENTS
Application .............................................................................................................. 3
Control Accuracy .............................................................................................................. 3
Technical Data ........................................................................................................ 3
Design Data ....................................................................................................................... 3
HLTSTAT Thermostat Nominal Setpoints ....................................................................... 3
Explosion Protection ........................................................................................................ 4
Installation Instructions ........................................................................................ 4
ROUTINE CHECK TESTS.................................................................................................. 5
Initial Operation ................................................................................................................ 5
Wiring Diagram ...................................................................................................... 7
Maintenance ........................................................................................................... 7
CE Declaration of Conformity ............................................................................... 8
WARRANTY........................................................................................................... 10
RETURN AND REPAIR POLICY ...................................................................................... 10
LIMITATION OF LIABILITY .............................................................................................. 11
© 2016 Pentair Equipment Protection
- 3 -
APPLICATION
When connected to an electric heater, the thermostat can regulate the temperature in a housing to the pre-set, nominal, setpoint; see HLTSTAT Thermostat Nominal Setpoints table below.
The thermostat closes the circuit when the temperature is below the setpoint and opens it when the temperature is above the setpoint.
CONTROL ACCURACY
The air temperature in a heated housing is not the same everywhere. Depending on the difference between inside and outside temperature (delta T), insulation, configuration of the heater and the installed equipment etc., the temperature (e.g. between top and bottom) can fluctuate by 18 F [10 C] or more.
For exact temperature control of an instrument, a proportional controller with temperature sensor should be used.
TECHNICAL DATA
DESIGN DATA
HLTSTAT10C, HLTSTAT20C
Rated voltage (VAC or VDC) 0 - 400V
Maximum Rated Current (Amps) (acc. to DIN VDE 0298)
10
Temperature Tolerance +/- 5 F [3 C]
Temperature class T6
Ambient temperature
-76 to +140 F (-60 to +60 C)
Maximum permissible operating temperature range at normal rating
-76 to +302 F
(-60 to +150 C)
Connection cable
39 (1m) long silicone cable, notch and oil
resistant, 3x AWG16; Ø 0.37 (9.4mm)
Conduit connection ½ NPT
Ingress Protection IP66 / IP68 (1bar/30min)
Material
seawater-proof aluminium, black
anodized
Length (in./mm) 3.5 (89)
Width (in./mm) 1.6 (41)
Depth (in./mm) 1.2 (30)
Weight (lb./g) 1.1 (28)
HLTSTAT THERMOSTAT NOMINAL SETPOINTS
Type Switch on Switch off
HLTSTAT10C 50 F / 10 C 64 F / 18 C
HLTSTAT20C 68 F / 20 C 82 F / 28 C
© 2016 Pentair Equipment Protection
- 4 -
EXPLOSION PROTECTION
TAE
Manufacturer INTERTEC-Hess
CSA Certificate 1655545 (LR43674)
CSA Type of Protection
Cl. I, Grp. ABCD T6
Cl. II Grp. EFG
IEC Scheme Certificate IECEx PTB 07.0054X
EC Type Examination Certificate PTB 03 ATEX 1136 X
Marking
II 2 G Ex d IIC T6
II 2 D Ex tD A21 IP68 T80 C
INSTALLATION INSTRUCTIONS
The thermostat must be attached to the face of the heater as noted. Pentair DAHHL finned heaters are equipped with slotted mounting rails in the fins. Slightly loosen the mounting bolt included in the thermostat.
Insert the head of the bolt into one of the slotted mounting rails of the finned profile. The PTFE spacer must remain outside, as this provides the right gap from the thermostat to the surface of the heater fins. Carefully tighten the bolt by turning the thermostat. DO NOT OVERTIGHTEN.
The thermostat is equipped with a ground terminal. Use a cable gland or a ½ NPT conduit depending on the application.
Be careful not to bend or exert any load on the connection cable during unpacking and transport.
Before entering the customer-supplied Ex junction box, the connection cable must be firmly installed and mechanically protected observing the permissible bending radius of 5 times the outside cable diameter.
If the connection is made in a hazardous area, the connection cable must be connected in a housing that meets the requirements of one of the types of ignition protection mentioned in EN 50014 Section 1.2.
When determining the operating temperature, the maximum permissible ambient temperature, self-heating and, possibly, heat transfer (medium) must be considered.
In dust hazardous areas, the applicable requirements of the EN 60079-14 have to be observed.
CAUTION! Remove the RED protection cap only for ½ NPT conduit installation. Never remove the adapter. See Figure 3 on page 6
The components must only be connected and secured by certified technical personnel in accordance with the label specifications rated voltage and rated current. Circuit breakers suitable for up to 16 A can be used for short circuit and line protection.
A ground terminal is provided for the purpose of ensuring potential equalization; see Figure 1 on page 5. The terminal is marked as such.