Safety Messages ..............................................................................2
Guidelines for Product Use .............................................................2
Operation Guidelines .......................................................................2
Installation .....................................................................................2
Plumbing .......................................................................................3
Starting ..........................................................................................3
General Maintenance .......................................................................3
Flushing the Muffler System ...........................................................3
Frequently Asked Questions (FAQ) ................................................3
Pump Curves ....................................................................................4
Limited Warranty ..............................................................................4
Exploded View of Compressor ........................................................5
Repair Kit Parts List .........................................................................5
Safety Messages
Safety is important to us. We have included safety messages throughout this manual and for your protection. Please read and follow all directions.
A safety message has a safety alert symbol followed by an explanation of what the hazard is, what can happen and what you should do to avoid injury. This is the safety alert symbol:
The safety alert symbol and "WARNING" or "CAUTION" will precede all safety messages:
ELECTRICAL SHOCK HAZARD
Disconnect electrical power at the circuit breaker or fuse box before installing this product. Install where it will not come into contact with water or other liquids and where it will be weather protected. Electrically ground this product. Failure to follow these instructions can result in death, fire or electrical shock.
Guidelines for Product Use
• Pump only clean, dry, atmospheric air.
• Operate at 32–104°F (0–40°C).
• Protect unit from dirt, foreign material and moisture.
• Never lubricate oilless air compressors.
Operation Guidelines
Installation
Make sure the wiring is done by a qualified electrician familiar with NEMA MG2 safety standards, national electric code and all local safety codes. Select fuses, motor protective switches or thermal protective switches to provide protection. Fuses act as short circuit protection for the motor, not as protection against overload. Incoming line fuses help to withstand the motor's starting current. Motor starters with thermal magnetic overload or circuit breakers protect the motor from overload or reduced voltage conditions. The wiring diagram attached to the product provides required electrical information.
Make sure that installation clearances do not block air flow. Blocking air flow over the product in any way can cause the product to overheat.
WARNING
You will be killed or seriously injured if you don't follow instructions.
CAUTION
You can be killed or seriously injured if you don't follow instructions.
• Do not pump flammable or explosive gases or use in an atmosphere that contains such gases.
• Protect all surrounding items from exhaust air. This exhaust air can become very hot.
• Corrosive gases and particulate material will damage the unit. Water vapor, oil-based contaminants or other liquids must be filtered out.
• Do not flush with kerosene or other combustible solvents.