Pentair AUTOTROL 255 Logix 740, AUTOTROL 255 Logix 760 User Manual

AUTOTROL
255 Logix
740 -760
User Guide 255 / LOGIX 740-760
2 / 28 Ref. MKT-UG-001 / A - 14.10.2016
Original settings
1
Installation no. 2: Resin type3: Resin volume4: Valve serial no. 5: Outlet water hardness6: [°tH] Tank size7: [°tH] Brine tank size8: [L]
Hydraulic settings
9
Injector size10: DLFC size11: Refill controller number12: BLFC size13:
Electrical settings
14
Voltage15: [V] Frequency16: [Hz] Power17: [W]
Software settings
18
Regeneration time19: Day of the week20: Days between regen.21: Qty of salt per regen.22: [kg] System capacity23: [m3°tH] Inlet water hardness24: [°tH] Cycle 125: [min] Cycle 2 : [min] Cycle 3 : [min] Cycle 4 : [min] Cycle 5 : [min] Cycle 6 : [min] Cycle 7 : [min] Cycle 8 : [min]
No. FR DE ES IT NL
1 Paramètres d'installation Installationseinstellungen Ajustes de instalación Impostazioni di installazione Installatie-instellingen 2 N° d’installation Installationsnr. Instalación nº Installazione n. Installatienr. 3 Type de résine Harztyp Tipo de resina Tipo di resina Harstype 4 Volume de résine Harzvolumen Volumen de resina Volume di resina Harsvolume 5 N° de série de vanne Ventil-Seriennr. Nº. de serie de válvula N. di serie valvola Klep serienr. 6 Dureté de l'eau en sortie Auslass-Wasserhärte Dureza de agua de salida Durezza acqua in uscita Uitlaat waterhardheid 7 Taille du réservoir Behältergröße Tamaño del depósito Dimensioni bombola Tankgrootte
8 Taille du réservoir de saumure Solebehältergröße
Tamaño del depósito de salmuera
Dimensioni tino di salamoia Pekelbakgrootte
9 Réglages hydrauliques Hydraulikeinstellungen Ajustes hidráulicos Impostazioni idrauliche Hydraulische instellingen 10 Taille d’injecteur Injektorgröße Tamaño del inyector Dimensioni iniettori Injectorgrootte 11 Taille DLFC DLFC-Größe Tamaño DLFC Dimensioni DLFC Grootte DLFC
12
Numéro de contrôleur de remplissage
Ansaugsteuerungsnummer
Número de controlador de relleno
Numero controller di reintegro Vulling controllernummer
13 Taille BLFC BLFC-Größe Tamaño BLFC Dimensioni BLFC Grootte BLFC 14 Paramètres électriques Elektrische Einstellungen Ajustes eléctricos Impostazioni elettriche Elektrische instellingen 15 Tension Spannung Tensión Tensione Spanning 16 Fréquence Frequenz Frecuencia Frequenza Frequentie 17 Alimentation Leistung Alimentación Potenza Stroom 18 Configuration Software-Einstellungen Ajustes de software Impostazioni software Software-instellingen 19 Temps de régénération Regenerationszeit Hora de regeneración Ora di rigenerazione Regeneratietijd 20 Jour de la semaine Wochentag Día de la semana Giorno della settimana Dag van de week 21 Jours entre deux régénérations Tage zwischen Regen. Días entre regen. Giorni tra rigen. Dagen tussen regeneratie 22 Qté de sel pour régénération Salzmenge pro Regen Cant de sal por regen. Q.tà di sale per rigen. Hoev. zout per regeneratie 23 Capacité du système Systemkapazität Capacidad del sistema Capacità del sistema Systeemcapaciteit 24 Dureté de l'eau en entrée Einlass-Wasserhärte Dureza de agua de entrada Durezza acqua in entrata Ingang waterhardheid 25 Cycles Zyklus Ciclo Ciclo Cyclus
User Guide 255 / LOGIX 740-760
Ref. MKT-UG-001 / A - 14.10.2016 3 / 28
Maintenance record book
Date¹ Description² Name³ Signature⁴
No. FR DE ES IT NL
1 Date Datum Fecha Data Datum 2 Description Beschreibung Descripción Descrizione Beschrijving 3 Nom Name Nombre Nome Naam 4 Signature Unterschrift Firma Firma Handtekening
User Guide 255 / LOGIX 740-760
4 / 28 Ref. MKT-UG-001 / A - 14.10.2016
1 . Generalities
Caution: Before handling the system, each user must read and understand the instructions in this document.The
safety instructions must be observed.Retain this document for future reference.
1.1. Scope of the documentation
The documentation provides the information necessary for appropriate use of the system. It informs the user to ensure efficient execution of operation or maintenance procedures. This document is not aimed at the installer. Visit our website https://www.pentairaquaeurope.com/product-finder/product-type/control-valves to download the installer manual.
1.2. Release management
1.3. Manufacturer identifier, product
1.4. Applicable norms
This product complies with the following guidelines:
And meets the following technical standards :
1.5. Limitation of liability
Pentair Quality System EMEA products benefit, under specific conditions, from a manufacturer warranty that may be invoked by Pentair’s direct customers. Users should contact the vendor of this product for applicable conditions and in case of a potential warranty claim. Pentair accepts no liability for equipment installed by the user upstream or downstream of Pentair products, as well as for process/production processes which are installed and connected around or even related to the installation. Disturbances, failures, direct or indirect damages that are caused by such equipment or processes are also excluded from the warranty. Pentair shall not accept any liability for any loss or damage of profits, revenues, use, production, or contracts, or for any indirect, special or consequential loss or damage whatsoever. Please refer to the Pentair List Price to know more about terms and conditions applicable to this product.
Release Date Author Description
A 14.10.2016 STF First edition
Manufacturer: Pentair Manufacturing Italy Srl
Via Masaccio, 13 56010 Lugnano di Vicopisano (PI) – Italy
Product: 255 / LOGIX 740-760
• DM174: "Regulation of materials and objects that can be used in stationary collection, treatment, supply and distribution of water intended for human consumption.";
• Attestation de Conformité Sanitaire (ACS): "Test and Certification valid for France performed by independent laboratories for the evaluation of materials and components that are in contact with drinking water.";
• 2006/42/EC: Machinery Directive; • 2014/35/UE: Low Voltage Directive;
• 2014/30/UE: Electromagnetic compatibility;
• 2011/65/EC: Restriction of use of certain hazardous substances in electrical and electronic equipment (RoHS). Meets the following technical standards :
• IEC/EN 60335-1; • IEC 61010-1;
• EN 55014-1; • EN 55014-2;
• EN 61000-3-2: 2006 + A1: 2009 + A2: 2009; • EN 61000-3-3: 2008;
• EN 61000-6-2: 2005; • N 61000-6-3: 2007 + A1: 2011;
• EN 61326-1.
A
User Guide 255 / LOGIX 740-760
Ref. MKT-UG-001 / A - 14.10.2016 5 / 28
EN
2 . Safety
2.1. Safety tags location
Note: Ensure that the safety tags on the device are completely legible and clean. If necessary, replace them with
new tags and put them in the same places.
2.2. Hazards
All the safety and protection instructions contained in this document must be observed in order to avoid serious or permanent injuries, damage to property or environmental pollution. At the same time, any other legal regulations, accident prevention and environmental protection measures, as well as any recognized technical regulations relating to appropriate and risk-free methods of working which apply in the country and place of use of the device must be adhered to. Any non-observation of the safety and protection rules, as well as any existing legal and technical regulations, will result in a risk of temporary or permanent injury, damage to property or environmental pollution.
2.2.1. Personnel
Only qualified and professional personnel, based on their training, experience and instruction as well as their knowledge of the regulations, the safety rules and operations performed, are authorized to carry out necessary work.
2.2.2. Material
To ensure proper system operation, observe the following points :
• Do not remove the locking bar.
• Be careful of electrical hazards due to the 230V/12V transformer.
• Do not put your fingers in the product (moving parts and residual voltage).
2.3. Hygiene and sanitation
Contact your local dealer and ask for a sanitization treatment if the treated water has an off-taste or an unusual odor. It is strongly recommended to disinfect the system at least once a year.
3 . Description
3.1. Technical specifications
3.2. Environmental conditions
Pressure ............................................Hydrostatic: 20 bar; Working: 1.4 - 8.2 bar
Water temperature ............................2 - 38°C
• Maximum relative humidity 80% for temperatures up to 31°C decreasing linearly to 50% relative humidity at 40°C.
• Main supply voltage fluctuations up to ±10% of the nominal voltage.
• Indoor use only.
• Temperature from 5°C to 40°C.
A
Installation warning
Locking bar label
Serial label
Model
Part number
Electrical ratings
Serial number
A
User Guide 255 / LOGIX 740-760
6 / 28 Ref. MKT-UG-001 / A - 14.10.2016
3.3. Description and components location
3.4. Bypassing
If the system is equipped with a bypass and if a problem occurs, turn the valves to bypass the system as shown in the picture below.
4 . Programming
Note: After 30 seconds without a button press, the unit returns to normal operation.
4.1. Basic programming
Note: At any time, press to return to the home screen.
Menus are displayed in a defined and incremental order.
Time setting and winter time - summer time change
Day of week
A Press when the time of the day is displayed.
Time flashes.
B Adjust displayed time with and . C Press to validate the selection and advance to the next parameter.
D Press .
Arrow flashes.
E Select displayed day with and . F Press to validate the selection and advance to the next parameter.
A
1
P
x2
x100
C
KG
LBS
MIN
PM
H
234 56 7
7
R
Controller
Outlet
Inlet
Drain
Manual REGEN button
UP button
SET button
DOWN button
LCD display
DLFC
Injector screen
Locking bar
B
Y
P
A
S
S
B
Y
P
A
S
S
B
Y
P
A
S
S
B
Y
P
A
S
S
Normal
operation
In Bypass
In InOut Out
A
A
A
1234567
7
R
A
A
A
A
A
1234567
7
R
A
A
A
A
User Guide 255 / LOGIX 740-760
Ref. MKT-UG-001 / A - 14.10.2016 7 / 28
EN
Regeneration time
4.2. History
To access the recorded information, press simultaneously and when the controller is in service mode.
5 . Operation
5.1. Recommendations
• Use only regenerate salts designed for water softening EN973;
• For optimal system operation, the use of clean salt free from impurities is recommended (for example salt pellets);
• Do not use ice melt, block, or rock salts;
• The sanitizing process (both with liquid and electrochlorination) introduces chlorine elements which may reduce the life of the ion exchange resins. Refer to the technical guides for resins in common use, providing necessary checks on the system.
5.2. Manual regeneration
Note: The unit returns to normal operation if no buttons are pressed within 30 seconds.
Manual delayed regeneration
6 . Maintenance
Mandatory: Cleaning and maintenance shall take place at regular intervals in order to guarantee the proper
functioning of the complete system, and be documented in the Maintenance record book.
7 . Troubleshooting
Please follow this procedure for any technical support:
A Collect the required information for a technical assistance request.
Product identification (see 2.1. Safety tags location, page 5 and Original settings, page 2;Error number displayed on the controller;
B Contact your local dealer who installed this device (see contact details on last page).
Also call him if the water tastes salty, if the water is not softened or if there is no salt consumption.
G Press .
Regeneration time flashes.
H Adjust displayed time with and .
Default setting: 2:00am.
I Press to validate the selection and advance to the next parameter.
The following steps appears after regeneration time, do not modify them : Days to regenerate (740 Time-clock controller only) Calendar override (760 Demand controller only) Amount of regenerant used per regeneration Estimated capacity Hardness (760 Demand controller only)
Immediate regeneration
A Press and hold for 5 seconds.
Regeneration icon displayed.Camshaft starts rotating to cycle C1.
Immediate double regeneration
B When cycle C1 starts, press and hold for 5 seconds.
x2 icon displayed.
Note:
The second regeneration begins after current regeneration completed.
The regeneration will start on the scheduled date
A Press .
Regeneration icon flashes.
Note:
To cancel: press again.
A
1234567
7
R
A
A
A
A
A
A
A
A
A
A
A
User Guide 255 / LOGIX 740-760
8 / 28 Ref. MKT-UG-001 / A - 14.10.2016
1 . Généralités
Attention: Avant de manipuler le système, chaque utilisateur doit lire et assimiler les instructions contenues dans le pré-
sent document. Les consignes de sécurité doivent être respectées. Conserver ce document pour référence ultérieure.
1.1. Champ d'application du document
La documentation contient les informations nécessaires à une utilisation appropriée du produit. Elle informe l'utilisateur afin d'assurer la bonne exécution des procédures de service et d’entretien. Ce document n’est pas destiné à l’installateur. Visitez notre site Web sur https://www.pentairaquaeurope.com/product-finder/product-type/control-valves pour télécharger le manuel d'installation.
1.2. Gestion des versions
1.3. Identifiant du fabricant, produit
1.4. Normes applicables
Ce produit est conforme aux directives suivantes :
Et est conforme aux normes techniques suivantes :
1.5. Limitation de responsabilité
Les produits du système qualité Pentair EMEA bénéficient, sous certaines conditions, d'une garantie du fabricant qui peut être invoquée par les clients directs de Pentair. Les utilisateurs doivent contacter le vendeur de ce produit pour les conditions applicables et dans le cas d'une éventuelle demande en garantie. Pentair n'accepte aucune responsabilité pour tout équipement installé en amont ou en aval des produits Pentair ainsi que pour tout procédé ou processus de production installé et connecté autour de l’installation ou même seu­lement en lien avec celle-ci. Toute défaillance ou panne et tout dommage direct ou indirect résultant d’un tel équipement ou de tels pro­cessus, sont également exclus de la garantie. Pentair n’acceptera aucune responsabilité pour toute perte ou pour tout dommage affectant les profits, les revenus, l’utilisation, la production ou les contrats, ou pour toute perte ou tout dommage indirect, spécial ou conséquent, quel qu’en soit la nature. Veuillez consulter la grille tarifaire de Pentait pour en savoir plus sur les modalités et les conditions applicables au présent produit.
Version Date Auteur Description
A 14.10.2016 STF Première édition
Fabricant : Pentair Manufacturing Italy Srl
Via Masaccio, 13 56010 Lugnano di Vicopisano (PI) – Italie
Produit : 255 / LOGIX 740-760
• DM174 : « Réglementation relative aux matériaux et objets qui peuvent être utilisés dans la collecte stationnaire, le traitement, la fourniture et la distribution de l'eau destinée à la consommation humaine »
• Attestation de Conformité Sanitaire (ACS) : « Essai et certification valable pour la France effectués par des laboratoires indépen­dants pour l’évaluation des matériaux et des composants qui sont en contact avec l'eau potable. »
• 2006/42/CE : Directive relative aux machines ;
2014/35/UE: Directive « Basse tension »;
2014/30/UE : Compatibilité électromagnétique ;
• 2011/65/CE : Restriction de l'utilisation de certaines substances dangereuses dans les équipements électriques et électroniques (RoHS) Conforme aux normes techniques suivantes :
• IEC/EN 60335-1 ; • IEC 61010-1 ;
• EN 55014-1 ; • EN 55014-2 ;
• EN 61000-3-2 : 2006 +A1 : 2009 + A2 : 2009 • EN 61000-3-3 : 2008
• EN 61000-6-2 : 2005 • EN 61000-6-3 : 2007 +A1 : 2011
• EN 61326-1.
A
User Guide 255 / LOGIX 740-760
Ref. MKT-UG-001 / A - 14.10.2016 9 / 28
FR
2 . Sécurité
2.1. Localisation des balises de sécurité
Information: S’assurer que les balises de sécurité sur l’appareil sont bien lisibles et propres. Si nécessaire, les remplacer
par de nouvelles étiquettes à disposer au même endroit.
2.2. Risques
Toutes les instructions de sécurité et de protection contenues dans ce document doivent être respectées afin d'éviter des blessures per­manentes ou graves, des dommages matériels ou tout risque de pollution à l'environnement. De même, toutes les autres réglementations et mesures de prévention des accidents et de protection de l'environnement, ainsi que toute réglementation technique reconnue relative aux méthodes de travail sûres et appropriées applicables dans le pays et sur le lieu d'utili­sation de l'appareil doivent être respectées. Toute infraction aux règles de sécurité et de protection ou à toute réglementation légale et technique existante comportera des risques de blessures temporaires ou permanentes, de dommages aux biens ou de pollution de l’environnement.
2.2.1. Personnel
Seuls les membres du personnel qualifiés et professionnellement formés sont autorisés à exécuter les opérations requises, en fonction de leur for­mation, de leur expérience, de leur instruction et de leur connaissance des règles de sécurité et des opérations à réaliser.
2.2.2. Matériau
Afin d'assurer le bon fonctionnement du système, tenir compte des points suivants :
• Ne pas retirer le levier de blocage.
• Prendre garde aux dangers électriques liés à la présence du transformateur 230V/12V.
• Ne pas mettre vos doigts dans le produit (pièces mobiles et tension résiduelle).
2.3. Hygiène et assainissement
Contacter votre revendeur et demander un traitement de désinfection si l'eau traitée a un mauvais goût ou une odeur inhabituelle. Il est fortement recommandé de désinfecter le système au moins une fois par an.
3 . Description
3.1. Spécifications Techniques
3.2. Conditions environnementales
Pression ................................................. hydrostatique : 20 bar ; Service : 1,4 - 8;2 bar
Température de l'eau................................. de 2 à 38 °C (de 35 à 100 °F)
• Humidité relative maximale de 80 % pour des températures allant jusqu'à 31 °C décroissant linéairement à 50 % d'humidité relative à 40 °C.
• Variations de la tension d’alimentation au secteur de ± 10% de la tension nominale.
• Pour utilisation en intérieur uniquement
• Température de 5 °C à 40 °C.
A
Avertissement avant
l’installation
Étiquette de levier de blocage
Étiquette de série
Modèle
Référence
Spécifications
électriques
Numéro de série
A
Loading...