Pentair AUTOMATIC BY-PASS VALVE KIT User Manual

AUTOMATIC BY-PASS VALVE KIT (P/N 462048)
FOR MASTERTEMP® AND MAX-E-THERM® POOL AND SPA HEATERS
INSTALLATION INSTRUCTIONS
FAILURE TO FOLLOW ALL INSTRUCTIONS AND WARNINGS CAN RESULT IN SERIOUS BODILY INJURY OR DEATH. THIS PRODUCT SHOULD BE
INSTALLED AND SERVICED ONLY BY A QUALIFIED POOL SERVICE PROFESSIONAL. INSTALLERS, POOL OPERATORS AND OWNERS MUST READ THESE WARNINGS AND ALL INSTRUCTIONS IN THE HEATER INSTALLATION AND USER’S GUIDE BEFORE USING THIS PRODUCT. THESE INSTRUCTIONS MUST BE LEFT WITH THE POOL OWNER.
Pentair Water Pool and Spa heater related products are available at: https://www.pentair.com/en/products/pool-spa-equipment/pool-heaters.html Call (800) 831-7133 for additional free copies of these instructions.
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS - SAVE THESE INSTRUCTIONS
Automatic By-pass Valve Overview
In conjunction with a Pentair IntelliFlo VF pump the automatic by-pass valve functionality of the latest MasterTemp heater will improve the head loss through the pool system, reduction of pump power consumption and the longevity of the heater by automatically taking the heater mostly out of the flow loop when not in use.
The following instructions describe how to configure your pool/spa hydraulics for a 3-way or 2-way automatic by-pass valve.
Related manuals:
IntelliValve Valve Actuator Manuals (P/N 522301)
Contents
2” 3-Way Valve (Pentair P/N 263026)
IntelliValve Actuator (Pentair P/N 521485)
2” Check Valve (Pentair P/N 263042)
P/N 462050.A 9/2020
1
AUTOMATIC BY-PASS VALVE SETUP INSTRUCTIONS
When installing this kit, basic safety precautions should always be followed. Read and follow all instructions.
Required installation tools:
#2 Phillips screwdriver
• Hacksaw (for cutting plumbing)
• 1/4” Nut driver
CAUTION! Before starting: Always disconnect AC power to the pool pump.
Automatic By-pass Valve Setup
Plumbing
1. Cut the heater inlet plumbing and install the 2” 3-Way valve (Pentair P/N 263026) as shown in Figure 1 & 2.
Cold Water In
Check
Valve
Hot Water Out To Pool
Figure 1. Valve positioned left side of heater
2. And the 2” check valve (Pentair P/N 263042).
3. Unscrew and remove the diverter valve knob and handle.
Figure 3. Diverter Handle/Knob
IntelliValve
IntelliValve
Cold Water In
Check Valve
Hot Water Out To Pool
Figure 2. Valve positioned left side of heater
Valve Knob
Valve Handle
2
AUTOMATIC BY-PASS VALVE SETUP INSTRUCTIONS
4. Remove the four (4) screws from the valve assembly top cover. See Figures 4 and 5 depending on where your heater is located relative to your valve.
Figure 4. Heater to Left of Valve
Figure 5. Heater to Right of Valve
3
Loading...
+ 5 hidden pages