Check entire box and inside all packing materials for parts. Before beginning
assembly, read the instructions and identify parts using the figures and parts listed in
this document. It is critical that all parts be carefully inspected by the installer prior to
installation to ensure that no damage occurred in transit and that a damaged part is
not used. If any damage occurred in transit, Pentair Water Commercial Pool and
Aquatics (“Pentair”) must be notified within three days of receipt of unit. Proper
installation cannot be overstressed, as an improper installation voids Pentair’s
warranty and may affect the safety of the user.
WARNING
IMPORTANT SAFETY INSTRUCTIONS
1. READ AND FOLLOW ALL INSTRUCTIONS. LIFT SAFETY CAN ONLY BE ENSURED IF THE LIFT
IS INSTALLED AND OPERATED PROPERLY – ACCORDING TO THESE INSTRUCTIONS.
2. WARNING- TO REDUCE RISK OF INJURY, DO NOT PERMIT CHILDREN TO USE OR OPERATE
THIS PRODUCT.
3. WARNING- DO NOT PERMIT CHILDREN TO PLAY ON THIS PRODUCT.
4. WARNING- NEVER APPLY DIRECT WATER PRESSURE TO ELECTRONIC COMPONENTS.
5. DO NOT USE THE AquaTRAMPT FOR WATER-DRAFTS OVER 9” (DECK TO WATERLINE).
6. NEVER OPERATE THIS LIFT UNDER LOAD WITH NO WATER (DRY POOL).
7. SAVE A COPY OF THESE INSTRUCTIONS.
WARNING
MAKE SURE THE AREA AROUND THE LIFT IS CLEAR BEFORE OPERATING. NEVER
OPERATE THE LIFT WITH ANY PERSON WITHIN THE OPERATING RANGE OF THE LIFT,
INCLUDING ON THE DECK OR IN THE WATER. NEVER MOVE THE LIFT DOWN WHILE
OVER THE DECK. IF THE LIFT COMES INTO CONTACT WITH THE DECK OR A WALL,
RELEASE THE BUTTON IMMEDIATELY OR PRESS THE EMERGENCY STOP BUTTON.
DO NOT ALLOW CHILDREN TO OPERATE THE LIFT WITHOUT SUPERVISION.
CHECK ALL NUTS AND BOLTS FOR TIGHTNESS AND FOR WORN PARTS BEFORE
EACH USE.
AquaTRAM PT Technical Support
Contact Technical support at:
Sanford, North Carolina (8 A.M. to 5 P.M.)
Phone: (800) 831-713
Fax: (919) 566-8920
Web sites: visit www.pentaircommercial.com
3
2
AquaTRAM PT POOL LIFT
TABLE OF CONTENTS
PAGE DESCRIPTION
4 PACKING LIST
5 INSTALLATION: ADA GUIDELINES
6-7 AquaTRAM PT ASSEMBLY INSTRUCTIONS
8 BATTERY CHARGING
9-10 TRANSPORTING AND USING THE AquaTRAM PT
11 TRANSPORT INSTRUCTIONS: CHAIR REMOVAL
12 AquaTRAM PT OPERATING INSTRUCTIONS
13-14 SAFETY & CARE FOR YOUR LIFT
15-18 TROUBLESHOOTING GUIDE
19 AquaTRAM PT INTEGRATED LIFT PARTS LIST
20 PORTABLE CART PARTS LIST
21 OPTIONS
22 WARRANTY
The AquaTRAM PT is designed and manufactured to be compliant with the Americans
with Disabilities Act (ADA). However, for the installed lift to be 100% compliant, the
installation must meet the requirement for CLEAR DECK SPACE as shown in the
diagram below. To be compliant, install the lift at 16 inches [406mm] from the pool edge
to the centerline of the seat, and make sure the deck has the required CLEAR DECK
SPACE as shown.
NOTE: As per ADA requirements the slope of the deck from the pool edge to the
centerline of the seat and within the clear deck space must be no greater than
1:48. The AquaTRAM PT should be used on pools with a deck to water
measurement no greater than 9”.
5
AquaTRAM PT- ASSEMBLY INSTRUCTIONS
1. Begin by placing the parts from the previous page at or near to the desired
poolside location.
2. Stack 10 supplied weight plates on the portable platform. To ensure
proper alignment stack 3 to 4 plates, check alignment by temporarily
putting the cover on, remove the cover and then stack 3 to 4 more plates.
Repeat until all 10 weight plates are on the platform and properly aligned.
3. Attach the weight stack cover assembly over the weight stack using the
supplied ¼” NYLOCK NUTS and ¼” FLAT WASHERS. NOTE: Be sure
to use silicone to seal the flange before bolting together.
4. Plug the ACTUATOR CABLE into the 24V CONTROL/BATTERY (see
next page) and attach it to the lift with the supplied WING BOLTS as
shown below. Make sure the actuator cable’s plug is fully inserted and
seated, or else the lift will not function (see next page).
6
PLUGS NOT SEATED
USING THE “EMERGENCY STOP BUTTON” PLUGS FULLY SEATED
On the side of the integrated control box is a large red
button. If you depress the “EMERGENCY STOP” button,
this will bypass the handset and stop the lift. The button
will lock in place until released. To release the
EMERGENCY STOP button and resume operation, turn
the button counter-clockwise until it pops out.
THE LIFT WILL NOT FUNCTION AGAIN UNTIL THE
EMERGENCY STOP BUTTON IS RELEASED!!
CHARGING THE BATTERY:
Before using the AquaTRAM PT Lift for the first time the 24V CONTROL/BATTERY
must be fully charged. This will take about 24 hours on the charger. It is also
recommended that the battery be fully charged before each use.
To recharge the battery, unplug all
cables and remove the 24V
CONTROL/BATTERY from the lift.
Plug the 24V CONTROL/BATTERY
into the charger as shown. When the
charger is plugged in the orange
CHARGE light will flash. When the
battery is fully charged, the CHARGE
light will stay on and the device is
ready to use.
CAUTION! THE UNIT WILL NOT CHARGE IF
THE EMERGENCY STOP BUTTON IS
DEPRESSED.
7
ALTERNATIVE: CHARGING THE BATTERY ON THE LIFT
The AquaTRAM PT is portable, so that it can be stored in an equipment or
storage room when not being used. If the AquaTRAM PT is used in this manner it
is allowable to charge the battery without removing the 24V
CONTROL/BATTERY from the lift. The Wall Charger is plugged directly into an
AC outlet, and the cord is plugged into the 24V CONTROL/BATTERY as shown
below.
NEVER CHARGE THE BATTERY ON THE LIFT NEAR WATER!
NEVER USE AN EXTENSION CORD WITH THE WALL CHARGER!
NEVER CHARGE THE BATTE RY OUTDOORS OR NEAR THE POOL!
8