CONTENTS
1. INTRODUCTION .................................................................................................. 2
2. FEATURES........................................................................................................... 2
3. UNPACKING ........................................................................................................ 3
4. DESCRIPTION OF EACH PART.......................................................................... 4
4-1. Display and symbols ................................................................................. 6
4-2. Switches.................................................................................................... 7
5. SETTING UP ........................................................................................................ 8
5-1. Attaching the display pole to the base ..................................................... 8
5-2. Installing the scale................................................................................... 10
5-3. Installing the batteries ..............................................................................11
6. BASIC OPERATION .......................................................................................... 12
6-1. Turning the power ON and OFF .............................................................. 12
6-2. Selecting a weighing unit......................................................................... 12
6-3. Basic weighing operation ........................................................................ 13
6-4. Weight display resolution ........................................................................ 13
7. COUNTING MODE............................................................................................. 14
8. COMPARATOR .................................................................................................. 15
9. CALIBRATION ................................................................................................... 17
9-1. Gravity acceleration correction................................................................ 17
9-2. Calibration using a weight ....................................................................... 18
9-3. Restoring to the factory setting values .................................................... 19
10. FUNCTIONS..................................................................................................... 20
10-1. Setting the parameters.......................................................................... 20
10-2. Function list ........................................................................................... 21
11. OPTIONS.......................................................................................................... 22
12. MAINTENANCE ............................................................................................... 22
12-1. Notes on maintenance .......................................................................... 22
12-2. Error codes............................................................................................ 22
13. SPECIFICATIONS............................................................................................ 23
13-1. Specifications ........................................................................................ 23
13-2. External dimensions.............................................................................. 24
GRAVITY ACCELERATION MAP .......................................................................... 26
1
1. INTRODUCTION
This manual describes how the SC/SE Series Wash Down Scales work and how to get the most out of them in terms of performance. Please read this manual completely before using the scale.
2. FEATURES
The SC/SE Series Wash Down Scales have the following features:
Dust-tight and water-tight construction, complying with IP68.
Water will not enter the scale even if immersed to a depth of 1 m for 24 hours.
The weighing platform of the SC series is made of stainless steel (SUS304), and
the SE series, steel. The weighing pan of both models is made of stainless steel (SUS430).
As a power source, size D batteries are used. The battery life, when Alkaline
batteries are used, is approximately 3,600 hours.
A large LCD with a character height of 39 mm is used.
Two weighing platform sizes are available. The SC-KAL and SE-KAL series have a
larger weighing pan, and the SC-KAM and SE-KAM series have a smaller weighing pan. Select a model that suits your own application.
Two types of weight display resolution are available, normal (1/3,000) and high
(1/6,000 or 1/7,500).
The counting function easily counts the number of objects of the same weight.
The comparator function compares the displayed value (weight value) with the
upper and lower limit values and shows the results. The optional OP-03 (SCE-03) comparator relay output can output the results as a relay signal.
The optional OP-02 (SCE-02) USB interface and OP-03 (SCE-03) RS-232C serial
interface can transmit the weight value to a personal computer.
2
3. UNPACKING
t
When unpacking, check whether all of the following items are included:
Instruction manual
SSCC//SSEE SSeerriieess
SC-30KAM / SC-60KAM / SC-150KAM / SC-60KAL / SC-150KAL
SE-30KAM / SE-60KAM / SE-150KAM / SE-60KAL / SE-150KAL
SC-KAL / KAM series ●SE-KAL / KAM series
WWaasshh DDoowwnn SSccaalleess
Pole support foo
*Pole support foot
*Only for the SE-KAM series
The cable length from the base to the display is approximately 1.5 m.
3
4. DESCRIPTION OF EACH PART
t
SC-KAL / KAM series
Weighing pan
Option slot
Spirit level
Display
Display pole
Display rear side
Battery cover
Leveling foo
Display knob
4
S-KAL / KAM series
Option slot
Display
Display pole
Weighing pan
Spirit level
Leveling foot
Display rear side
Battery cover
Display knob
5
4-1. Display and symbols
Display
STABLE indicator
NET indicator
ZERO indicator
ON/OFF switch
HI,OK,LO indicators
PRINT switch
Symbols
LCD
ON/OFF
UNITS switch
ZERO switch
Weighing units
Battery indicator
TARE swit ch
Symbol Description
STABLE
NET ◄
Turns on when the weight value is stable.
Turns on when the NET weight is displayed. (The tare operation is in progress.)
ZERO ◄ Turns on when the scale shows zero.
iHIi OK iLO
i
Turns on when the comparator results are displayed.
Weighing units “lb”, “oz”, “kg” and “pcs” are available. A selected unit turns on.
Battery indicator
The battery indicator changes as the battery capacity decreases, as shown below:
New Replace the batteries.
6
4-2. Switches
Switch Description
ON/OFF
ON/OFF switch
Turns the power ON or OFF. When turned ON, the scale will be automatically set to zero (power-on zero).
PRINT switch
Outputs the weight value to the printer. In the setting mode, this switch is used to increase the value of the selected blinking digit by one.
UNITS switch
Switches the weighing unit. In the setting mode, this switch is used to shift the blinking digit to the right.
ZERO switch
Zeroes the scale and sets the display to zero.
TARE switch
Subtracts the tare (container) weight placed on the weighing pan. In the setting mode, this switch is used to store the setting value and proceed to the next step.
The ZERO and TARE switches work when the weight value is stable.
The ZERO switch will zero the scale if the weight value is within ±2% of the
weighing capacity (kg) around the power-on zero point. The ZERO turns on. (ZERO operation)
The TARE switch will tare the scale and subtract the weight to zero as a tare
weight when the weight is a plus value. In this case the ZERO◄ and NET◄ indicators turn on. (TARE operation) When the tare is removed while the tare operation is in progress and the scale returns to the zero point, the ZERO◄ and NET◄ indicators turn on. In this case the displayed tare value will be negative.
When the tare is removed while the tare operation is in progress and the ZERO
operation described above is performed, the tare operation previously done is cleared and the NET◄ indicator turns off.
indicator
7