Penberthy Sight Flow Indicators Dual Window 300 P-Cl. ANSI & FM-Approved, Penberthy-EN Manuals & Guides

PENBERTHY SIGHT FLOW INDICATORS
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Before installation these instructions must be fully read and understood
TABLE OF CONTENTS
Product warranty ������������������������������������������������ 1 1�0 About the manual ��������������������������������������� 2 2�0 Introduction ������������������������������������������������� 2 2�1 Features and specifications ���������������� 2 2�2 Design ratings at maximum and
minimum operating temperatures ���� 2 2�3 Design ratings for FM approved units 3 2�4 Application data ����������������������������������� 3 3�0 Inspection and performance confirmation 3 3�1 Receiving inspection ���������������������������� 3 3�2 User's rating inspection ���������������������� 3 4�0 Installation �������������������������������������������������� 3 4�1
4�2 Positioning of specific models ������������ 4 4�3 Bolt torque �������������������������������������������� 4 5�0 Operation ����������������������������������������������������� 5 5�1 Pre-operational check� ����������������������� 5 5�2 Hydrostatic pressure test ������������������� 5 5�3 Operating ���������������������������������������������� 5 6�0 Maintenance ����������������������������������������������� 5 6�1 Preventative maintenance ������������������ 5 6�2 Maintenance procedures� ������������������� 5 6�3 Troubleshooting for soundness
7�0 Removal-disassembly-reassembly ���������� 6 7�1 Disassembly ����������������������������������������� 6 7�2 Reassembly������������������������������������������ 6 8�0 Disposal at end of useful life ��������������������� 8 9�0 Telephone assistance��������������������������������� 8 10�0 Exploded parts drawing ����������������������������� 9
Tables and Figures
Table 1 Design ratings at maximum and
Table 2 Design ratings for FM approved
Table 3 Bolt torque values ������������������������������ 4 Figure 1 Bolt tightening sequence ������������������� 4 Figure 2 Bolt loosening sequence ������������������� 5 Figure 3 Re-assembly��������������������������������������� 7 Figure 4 Exploded parts drawing ��������������������� 9
and precautions �����������������������������������4
of glass ������������������������������������������������� 6
minimum operating temperatures ��� 2
units ���������������������������������������������������� 3
Product warranty
Emerson warrants its Penberthy products as designed and manufactured by Emerson to be free of defects in the material and workmanship for a period of one year after the date of installation or eighteen months after the date of manufacture, whichever is earliest� Emerson will, at its option, replace or repair any products which fail during the warranty period due to defective material orworkmanship�
Prior to submitting any claim for warranty service, the owner must submit proof of purchase to Emerson and obtain written authorization to return the product� Thereafter, the product shall be returned to Emerson, with freight paid�
This warranty shall not apply if the product has been disassembled, tampered with, repaired or otherwise altered outside of Emerson factory, or if it has been subject to misuse, neglect oraccident�
The responsibility of Emerson hereunder is limited to repairing or replacing the product at its expense� Emerson shall not be liable for loss, damage or expenses related directly or indirectly to the installation or use of its products, or from any other cause or for consequential damages� It is expressly understood that Emerson is not responsible for damage or injury caused to other products, buildings, personnel or property, by reason of the installation or use of its products�
THIS IS EMERSON’S SOLE WARRANTY AND IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED WHICH ARE HEREBY EXCLUDED, INCLUDING IN PARTICULAR ALL WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE�
This document and the warranty contained
herein may not be modified and no other warranty, expressed or implied, shall be made by or on behalf of Emerson unless made in writing and signed by the General Manager or Director of Engineering of Emerson�
Emerson.com/FinalControl © 2019 Emerson� All Rights Reserved�
VCIOM-07131-EN 19/01
PENBERTHY SIGHT FLOW INDICATORS
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
1.0 ABOUT THE MANUAL
This manual has been prepared as an aid and guide for personnel involved installation or maintenance� All instructions must be read and understood thoroughly before attempting any installation, operation, or maintenance�
Important: Penberthy does not have control over the manner in which its dual window sight flow indicator is handled, installed, or used, and Penberthy cannot and does not warrant or guarantee that a dual window sight flow indicator is suitable or compatible with the user's specificapplication�
WARNING
Always wear safety glasses when installing, servicing or operating a dual window sight flow indicator. Failure to follow any instruction could possibly result in a malfunction of the dual window sight flow indicator or glass breakage with resulting sudden release of pressure, causing serious personal injury or property damage.
2.0 INTRODUCTION
2.1 Features and specifications
Penberthy dual window sight flow indicators are designed for the observation of flow in a process line� They are designed with dual glass to double the protection in case of accidental breakage of the inner or outer glass� They are available in a variety of models, sizes and connection styles� The user should refer to Penberthy dimension sheets to determine specific models and connection styles available�
TABLE 1 - MAXIMUM DESIGN RATINGS FOR UNITS WITH TEMPERED GLASS
Body material Temp rating
Carbon steel
316 Stainless steel
Body material Temp rating
Carbon steel
316 Stainless steel
-20°F (-29°C) to +100°F (38°C) AT +250°F (121°C) AT +300°F (149°C) AT +400°F (204°C) AT +500°F (260°C)
-20°F (-29°C) to +100°F (38°C)
-65°F (-54°C) to +100°F (38°C)
-300°F (-184°C) to +100°F (38°C) AT +250°F (121°C) AT +300°F (149°C) AT +400°F (204°C) AT +500°F (260°C)
-20°F (-29°C) to +100°F (38°C) AT +250°F (121°C) AT +300°F (149°C) AT +400°F (204°C) AT +500°F (260°C)
-20°F (-29°C) to +100°F (38°C)
-65°F (-54°C) to +100°F (38°C)
-300°F (-184°C) to +100°F (38°C) AT +250°F (121°C) AT +300°F (149°C) AT +400°F (204°C) AT +500°F (260°C)
Teflon
740 (5�10)
605 (4�17)
720 (4�96)
480 (3�31)
PCTFE (KEL-F®) Neoprene
740 (5�10)
635 (4�38)
720 (4�96)
515 (3�55)
Gasket material (psig (MPa))
®
740 (5�10)
605 (4�17)
720 (4�96)
480 (3�31)
®
Grafoil
Gasket material (psig (MPa))
740 (5�10)
655 (4�52)
720 (4�96)
560 (3�86)
740 (5�10)
605 (4�17)
720 (4�96)
480 (3�31)
IFG-5500
®
®
740 (5�10)
635 (4�38)
720 (4�96)
515 (3�55)
Buna-N
740 (5�10) 670 (4�62)
720 (4�96)
590 (4�07)
Viton
®
2.2 Design ratings at maximum and minimum operating temperatures
Refer to Table 1
2
PENBERTHY SIGHT FLOW INDICATORS
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
2.3 Design ratings for FM approved units
To determine maximum allowable working pressure for a specific temperature within the design limits stated above, the user should refer to Penberthy dimension sheets, or when provided, the specifically stated design limits on a Penberthy product proposal�
2.4 Application data
NOTE
For specific application data within the above ranges, consult the Penberthy product proposal for the specific model and size dual window sight flow indicator, or request Penberthy to supply the applicable Technical Data Bulletin�
WARNING
Never exceed these design ratings or application data limits. Exceeding design ratings or application data limits can cause serious personal injury or property damage.
3.0 INSPECTION AND PERFORMANCE CONFIRMATION
3.1 Receiving inspection
Upon receipt of dual window sight flow indicator, check all components carefully for damage incurred in shipping� If damage is evident or suspected, do not attempt installation� Notify carrier immediately and request a damage inspection�
3.2 Users' rating inspection
The user should confirm that: 1� The dual window sight flow indicator model
number and pressure/temperature rating stamped on nameplate (163) conforms to the description on the user's purchase order�
2� The operating conditions described in
the purchase order agree with the actual conditions at the installation site�
3� The actual operating conditions at the
installation site are within the application data shown on the Penberthy Technical Data Bulletin referred to above�
4� The materials of construction of the sight
flow indicator are compatible with both the contained fluid and surrounding atmosphere in the specific application�
TABLE 2
Gasket material (psig (MPa))
Body material Temp rating
Carbon steel 100°F (38°C) 300 (2�10) 316 Stainless steel 100°F (38°C) 300 (2�10)
IFG-5500
®
IMPORTANT
If the size, model or performance data of the dual window sight flow indicator as received does not conform with any of the criteria above, do not proceed with installation. Contact an authorized Penberthy distributor for direction on what to do.
4.0 INSTALLATION
Use only qualified experienced personnel who are familiar with this equipment and thoroughly understand all the instructions in this manual for the installation of this equipment�
Refer to Penberthy dimension sheets or Penberthy product proposal to obtain dimensional information for the specific size and model dual window sight flow indicator�
WARNING
Do not proceed with installation of a dual window sight flow indicator unless the glass has been examined and is free of scratches and other imperfections and the connections and inside of the dual window sight flow indicator have been cleaned and are free of any foreign materials. Glass that is chipped or scratched is weakened and should not be used under any circumstances. Pressure/temperature ratings within Table 1 and 2 are no longer valid for glass that is weakened. Failure to comply can cause serious personal injury or property damage.
Check the exploded view Figure 4 for the location of the inlet and outlet connections, and for the direction of the flow arrow to insure correct hook up�
GRAFOIL
®
3
PENBERTHY SIGHT FLOW INDICATORS
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
TABLE 3 - BOLT TORQUE VALUES
Neoprene®, Unit size in inches
½ and ¾ 8 to 10
1 8 to 11
1¼ and 1½ 9 to 12
2 17 to 20
2 ½ and 3 41 to 44
4 70 to 73
6 and 8 149 to 153
Buna-N, Viton
Tempered glass Tempered glass Tempered glass Tempered glass Tempered glass
(11 to 14)
(11 to 15)
(13 to 17)
(23 to 28)
(56 to 60)
(95 to 99)
( 202 to 208)
®
®
Teflon
10 to 12
(14 to 17)
12 to 15
(17 to 21)
13 to 16
(18 to 22)
25 to 28
(34 to 38)
61 to 64 (83 to 87) 98 to 101
(133 to 137)
217 to 221
(295 to 300)
4.1 Effect of related piping and precautions
1� Do not impose system piping loads on dual
window sight flow indicator� Unit is not designed to be a load bearing component� Piping must be supported and aligned with sight flow indicator connections to reduce the possibility of stresses imposed on theunit�
2� Locate the dual window sight flow indicator
where it can be easily seen�
3� Locate the dual window sight flow
indicator away from areas where objects may be dropped, thrown, or generally allowed to effect contact with the viewing windowglass�
4� Locate the dual window sight flow indicator
so it is protected from dust, grit, tools, and any other objects which may scratch, chip, or break the viewing window glass�
5� Locate the dual window sight flow indicator
so it is protected from external thermal shock, such as would be imposed on a unit in a high temperature application when exposed to a cold air blast or a cold waterwash�
WARNING
Failure to mount, protect, and locate the dual window sight flow indicator as described within items 1 through 5 above can cause serious personal injury or property damage.
Gasket material (ft·lb (Nm))
®
Grafoil
9 to 11
(13 to 15)
10 to 13
(14 to 18)
11 to 14
(15 to 19)
22 to 25
(30 to 34)
53 to 56
(72 to 76)
N/A 101 to 104
N/A 223 to 227
PCTFE
(KEL-F® ) IFG-5500®
10 to 12
(14 to 17)
12 to 15
(17 to 21)
13 to 16
(18 to 22)
26 to 29
(36 to 40)
63 to 66
(86 to 90)
(137 to 141)
(303 to 308)
(149 to 153)
(231 to 235)
(525 to 530)
4.2 Positioning of specific models
1� Flapper models may be mounted in a
horizontal plane provided the flapper closes over the inlet port by gravity when there is no flow�
2� Plain or rotator models may be mounted in
any acceptable position�
3� Drip tube models should be mounted
in a vertical plane with the flow arrow pointingdownward�
4� Ball models should be mounted in a
horizontal or vertical plane with the flow arrow pointing upward�
4.3 Bolt torque
Refer to Table 3
IMPORTANT
Prior to any bolt torque checks, the dual window sight flow indicator must be relieved of all pressure or vacuum, have been allowed to reach ambient temperature, and drained or purged of all fluids.
Bolt torque is vital to the proper operation of a dual window sight flow indicator� Gaskets compress over a period of time; therefore, bolt torque values must be checked, and brought up to those recommended in Table 3 by following the bolt tightening sequence in Figure 1�
18 to 21
(24 to 29)
21 to 25
(29 to 34)
23 to 26
(31 to 35)
44 to 47
(60 to 64)
110 to 113
170 to 173
387 to 391
FIGURE 1
5
8
Bolt tightening sequence
Sizes ½" through 1"
1
4
2
Bolt tightening sequence
Sizes 1¼" through 8"
1
4
3
2
3
7
6
4
PENBERTHY SIGHT FLOW INDICATORS
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
5.0 OPERATION
5.1 Pre-operational check
1� Check that all installation procedures have
been completed�
2� Check that bolts have been torqued to their
proper values as stated in Table 3�
3� Check that glass is clean and free of any
damage as described in Section 4�0�
4� Check to determine that all connections
are pressure tight�
5.2 Hydrostatic pressure test
1� Take all precautions necessary to handle
the possibility of leakage�
2� Hydrostatic pressure test installation to at
least 50 psig (340 kPaG), and correct any leakage before proceeding�
5.3 Operating
WARNING
Dual window sight flow indicator installations should be brought into service slowly to avoid excessive shock or stress on glass. Rapid pressurization of sight flow indicator can cause glass breakage with resulting sudden release of pressure, causing serious personal injury or property damage.
6.0 MAINTENANCE
Use only qualified, experienced personnel who are familiar with this equipment and thoroughly understand all the instructions in this manual for all maintenance�
WARNING
Do not proceed with any maintenance unless the dual window sight flow indicator has been relieved of all pressure or vacuum, has been allowed to reach ambient temperature and has been drained or purged of all fluids. Failure to do so can cause serious personal injury or property damage.
Determine upon evaluation of your own operating experience an appropriate maintenance schedule necessary for the specific application� Realistic maintenance schedules can only be determined with full knowledge of the services and application situation involved�
6.2 Maintenance procedures
WARNING
Regular and careful attention must be given to the cleaning and inspection of glass. Glass that is etched or even slightly scratched is weakened and may break under pressure. Design ratings listed in Section 2.2 and 2.3 are no longer valid for sight flow indicators that contain scratched, worn, or otherwise damaged glass, and such glass must be immediately replaced. Failure to do so can cause serious personal injury or property damage.
1� Glass a� Keep glass clean using a commercial
glass cleaner and a soft cloth� DO NOT use a wire brush, metal scraper or any device which could scratch the glass�
b� Inspect the surface of the glass for any
signs of clouding, etching, scratching, or physical damage such as bruises, checks or corrosion that penetrates the outer surface of the glass� Shining a light at approximately a 45° angle will aid in detecting some of these conditions, which will glisten more brightly than the surrounding glass when reflecting light� Detection of any such problem areas or any surface wear is sufficient evidence of damage� Immediately take sight flow indicator out of service� Do not proceed with operation of dual window sight flow indicator until the glass has been replaced by following the Disassembly­Reassembly instructions in Section 7�0�
FIGURE 2
4
1
Bolt loosening sequence
Sizes ½" through 1"
2
3
Bolt loosening sequence
Sizes 1¼" through 8"
8
5
6
7
4
1
2
3
6.1 Preventative maintenance
Create maintenance schedules, safety manuals, and inspection details for each specific installation of a dual window sight flow indicator�
On all installations, regularly check the following items for purposes of maintenance: 1� Glass, for cleanliness and signs of damage
or wear�
2� Shields, if used, for signs of clouding, wear,
or deterioration�
3� Sight flow indicator for signs of leakage at
gaskets, or at connections�
4� Sight flow indicator, for signs of internal or
external corrosion�
5� Bolt torque values�
5
PENBERTHY SIGHT FLOW INDICATORS
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
2� Shields Shields which show any signs of clouding,
wear, or deterioration are an indication that the sight flow indicator glass has been exposed, or could soon become exposed to the contained fluid� Immediately take sight flow indicator out of service� Do not proceed with operation of sight flow indicator until shields and glass have been replaced by following the Disassembly-Reassembly
instructions in Section 7�0� 3� Gasket leaks Gasket leaks must be immediately repaired�
Do not proceed with operation of a dual
window sight flow indicator until glass,
gaskets and cushions have been replaced
by following the Disassembly-Reassembly
instructions in Section 7�0� 4� Connection leaks Leaks at a flanged or threaded connection
should be corrected by tightening the bolts
at the connection or by taking the sight flow
indicator out of service and remaking the
connection using Teflon
on all male pipe threads� 5� Corrosion It is the user's responsibility to choose
a material of construction compatible
with both the contained fluid and
surrounding atmosphere in the user's
specific application� If internal or external
corrosion are present, an investigation
must immediately be carried out by the user
as to the cause of the problem, including
consultation with an authorized Penberthy
distributor� 6� Bolt torque Bolt torque schedules should be developed
by checking bolt torque values daily until
an appropriate cycle becomes apparent�
The appropriate schedule is such that the
minimum torque is always maintained while
not exceeding maximums at any time as
shown in Table 3�
6.3 Troubleshooting
Problem: Glass or shield becomes etched
or clouded in service�
Cause: Fluid being handled is not
compatible with the glass or shield material�
Cure: Install shields that are unaffected
by fluid� Problem: Glass continually breaks in service� Cause: Warped body as a result of
mechanical or thermal stresses� Cure: Replace sight flow indicator�
®
tape or equivalent
7.0 REMOVAL-DISASSEMBLY-REASSEMBLY
WARNING
Do not proceed with the removal or disassembly of a dual window sight flow indicator from connecting piping unless the sight flow indicator has been relieved of all pressure or vacuum, has been allowed to reach ambient temperature and has been drained or purged of all fluids. Failure to do so can cause serious personal injury or property damage.
7.1 Disassembly
a� Dual window sight flow indicators should be
disassembled by holding sight flow indicator firmly and loosening the bolts by following the bolt loosening sequence shown in Figure 2 for the specific size sight flow indicator�
WARNING
Once a dual window sight flow indicator has been disassembled, all glass, gaskets, cushions, and shields (where used) must be disposed of since they are permanently deformed by compression. Do not under any circumstances re-use those items since they can cause leaks or high stress points resulting in glass breakage. If re-used, the glass may break causing serious personal injury or property damage.
7.2 Reassembly
a� Refer to exploded view Figure 4� b� Prepare for installation of new glass by first
cleaning the gasket seating surfaces on the housing (181), the body (11), and the cushion seating surfaces on the glass covers (1)� This should be done using a soft metal scraper (preferably brass) to remove all burrs, rust, and bits of old gasket or cushion which may be present� Exercise extreme care to avoid gouging or scarring gasket or cushion seating surfaces�
WARNING
Failure to prepare gasket or cushion surfaces as described above can result in leaks or glass breakage with resulting serious personal injury or property damage.
c� Upon receipt of glass, inspect each piece
individually for shipping damage� During inspection, and during any subsequent handling of glass, care must be exercised to keep glass (especially the polished faces) from contacting each other or any other surfaces including table tops� If shipping damage is evident or suspected, notify carrier immediately and request a damage inspection� Glass should be kept in original wrap within original box until ready to use�
6
PENBERTHY SIGHT FLOW INDICATORS
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Bumping or sliding of glass against each other or against other surfaces may result in glass breaking, scratching, or chipping� Glass that is broken is dangerous and useless and should be disposed of in a safe manner determined by the user� Glass that is chipped or scratched is weakened and should not be used under any circumstances� Pressure/temperature ratings within Table 1 and 2 are no longer valid for glass that is weakened�
d� Place the sight flow indicator in a horizontal
position�
e� Install glass gasket (7) and housing gasket
(7B) on gasket surfaces of body�
f� Place band (331) around glass (48) and
center glass on gasket� g� Place gasket (7A) centered on glass� h� Prior to assembling housing over glass,
some measurements must be taken to
determine if any shim gaskets are required
to be installed between glass gasket and
housing in order to insure a proper seal of
the housing to the body� See Figure 3� 1� Measure the distance from the top
surface of the housing gasket to the top surface of the glass gasket, Dim "A"�
2� Measure the counter bore depth of
the housing, Dim� "B"� If Dim� "B" is greater than Dim "A", subtract Dim "A" from Dim� "B"� The difference of these measurements will determine what total thickness of shim gaskets will need to be installed between the top of the glass gasket and the housing�
Note: if Dim "A" and Dim� "B" measure the
same, no shim gaskets will be required� 3� Install proper thickness of shim
gaskets, if required, on top of glass gasket making sure that all gaskets are centered on glass�
i� Assemble housing (181) over glass, making
sure that all components stay centered� j� Place gasket centered inside housing� k� Place band around glass and center on
gasket� l� Place cushion (8) on glass and housing
gasket on housing� m� Prior to assembly of cover over glass, more
measurements must be taken to determine
if any shim gaskets are required to be
installed between cushion and cover to
insure a proper seal of the housing to the
cover� See Figure 3�
1� Measure the distances from the top
surface of the housing gasket to the top surface of the glass cushion, Dim "C"�
2� Measure the counter bore depth of the
cover, Dim� "D"�
3� If Dim� "D" is greater than Dim "C",
subtract Dim "C" from Dim� "D"� The difference of these dimensions will determine what total thickness of shim gaskets will need to be installed between the top of the glass cushion and the cover�
Note: if Dim "C" and Dim� "D" measure the
same, no shim gaskets will be required�
4� Install proper thickness of shim gaskets,
if required, on top of the glass cushion making sure that all gaskets are
centered on glass� n� Install cover into place� o� Turn assembly over making sure that all
components stay aligned and follow the same procedures above for the opposite side�
p� Threads on studs (3) and nuts (4) must be
cleaned of paint, rust, and scale� Apply a light coat of oil to the threads and insert bolts through the nameplate and two (2) covers, and install nuts finger tight�
q� Use a torque wrench to tighten the bolts�
Tighten the bolts in a sequence as shown in Figure 1� Tighten bolts in increments of 5 ft·lb (7 Nm) or 50% of torque value as shown in Table 3, whichever is greater� Continue tightening sequence at 5 ft·lb (7 Nm) max� torque until torque values in Table 3 are reached�
r� Gaskets will become compressed a short
time after bolts are tightened and torque values will decrease� Therefore, the sight flow indicator must be retorqued after 24 hours in service, to values established in Table 3 for the specific model dual window sight flow indicator�
WARNING
Do not re-torque a sight flow indicator while under pressure. A sight flow indicator in service must be freed of all pressure or vacuum, allowed to reach ambient temperature and be drained or purged of all fluids before retorquing is performed. Failure to follow this procedure can result in serious personal injury or property damage.
s� Refer to Section 4�0 Installation and
Section 5�0 Operation when returning dual window sight flow indicator to service�
FIGURE 3Safety instructions
“D”
Housing
“B”
Body
Cover
“C”
“A”
7
PENBERTHY SIGHT FLOW INDICATORS
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
8.0 DISPOSAL AT END OF USEFUL LIFE
Penberthy Dual Window Sight Flow Indicators are used in a variety of fluid applications� By following the appropriate federal and industry regulations, the user must determine the extent of preparation and treatment the Sight Flow Indicator must incur before its disposal� A Material Safety Data Sheet (MSDS) may be required before disposal services accept certain components�
Metal, glass and polymers should be recycled whenever possible� Refer to order and Emerson Material Specification sheets for materials of construction�
9.0 TELEPHONE ASSISTANCE
If you are having difficulty with your Dual Window Sight Flow Indicator, contact your local Penberthy distributor� You may also contact the factory direct at (956) 430-2500 and ask for an applications engineer� So that we may assist you more effectively, please have as much of the following information available as possible when you call:
- Model #
- Name of the company from whom you purchased the sight flow indicator
- Invoice # and date
- Process conditions (pressure, flow rates, tank shape, etc)
- A brief description of the problem
- Trouble shooting procedures that failed
If attempts to solve your problem fail, you may request to return your Sight Flow Indicator to the factory for intensive testing� You must obtain a Return Authorization (R�A�) number from Emerson before returning anything� Failure to do so will result in the unit being returned to you without being tested, freight collect� To obtain an R�A� number, the following information (in addition to that above) is needed:
- Reason for return
- Person to contact at your company
- "Ship To” address
There is a minimum charge for evaluation of non-warranty units� You will be contacted before any repairs are initiated should the cost exceed the minimum charge� If you return a unit under warranty, but is not defective, the minimum charge will apply�
NOTES
Grafoil® is a registered trademark of Graftech, Inc� IFG-5500® is a registered trademark of Garlock� Neoprene®, Viton® and Teflon® are registered trademarks of E� I� duPont de Nemours and Company� PCTFE (formerly known as Kel-F® - a registered trademark of the 3M company) now manufactured by Daikin�
8
PENBERTHY SIGHT FLOW INDICATORS
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
10.0 EXPLODED PARTS DRAWING
FIGURE 4
4
100
163
163A
1
331
7A
8
48
3
Inlet
connection
125
115A
106
115
43
181
7B
7A
331
48
7
9
7B
Outlet
connection
171
11
Typical drop tube type
128
Typical rotator type
Typical flapper type
Pos Description
100
1 Cover 3 Stud 4 Nut 7 Gasket 7A Gasket 7B Gasket 8 Cushion 9 Shield* 11 Body 43 Flapper 48 Glass 100 Screw 106 Rotator 115 Spacer 115A Spacer 125 Washer 128 Pin 137 Bolt 163 Nameplate 163A Nameplate 171 Tube 181 Housing 331 Band
RECOMMENDED SPARE PARTS
Ref no. Item Qty.
7 Gasket 2 7A Gasket 4 7B Gasket 2 8 Cushion 2 9 Shield* 2 48 Glass 4
* Shields are optional
PART LIST
Neither Emerson, Emerson Automation Solutions, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance of any product� Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user�
Penberthy is a mark owned by one of the companies in the Emerson Automation Solutions business unit of Emerson Electric Co� Emerson Automation Solutions, Emerson andthe Emerson logo are trademarks and service marks of Emerson Electric Co� All other marks are the property of their respective owners�
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability� All sales are governed by our terms and conditions, which are available upon request� We reserve the right to modify or improve the designs or specifications of such products at any time without notice�
Emerson�com/FinalControl