Penberthy Threaded Sight Windows, Penberthy-EN Manuals & Guides

PENBERTHY THREADED SIGHT WINDOWS
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
Before installation, these instructions must be carefully read and understood.
TABLE OF CONTENTS
TABLES AND FIGURES
Prior to submitting any claim for warranty service, the owner must submit proof of purchase to Emerson and obtain written authorization to return the product. Thereafter, the product shall be returned to Emerson, with freight paid.
This warranty shall not apply if the product has been disassembled, tampered with, repaired or otherwise altered outside of Emerson factory, or if it has been subject to misuse, neglect or accident.
The responsibility of Emerson hereunder is limited to repairing or replacing the product at its expense. Emerson shall not be liable for loss, damage or expenses related directly or indirectly to the installation or use of its products, or from any other cause or for consequential damages. It is expressly understood that Emerson is not responsible for damage or injury caused to other products, buildings, personnel or property, by reason of the installation or use of its products.
Product Warranty ........................................... 1
1. About the Manual ...................................... 2
2. Introduction............................................... 2
2.1 System Description ................................ 2
3. Available Models ....................................... 2
3.1 Design Ratings at Maximum and
Minimum Operating Temperatures ...... 2
4. Assembly................................................... 3
4.1 Assembling Threaded Sight Windows .. 3
5. Installation ................................................ 3
6. Operation .................................................. 4
7. Maintenance .............................................. 4
7.1 Maintenance procedures ....................... 4
7.2 Troubleshooting ..................................... 4
8. Removal-Disassembly-Reassembly ......... 5
8.1 Disassembly ........................................... 5
8.2 Reassembly ............................................ 5
9. Disposal at End of Useful Life ................... 5
10. Telephone Assistance ............................... 5
11. Exploded Parts Diagram ........................... 6
Table 1 Maximum Design Ratings for
Units with Tempered Glass ............ 2
Table 2 Cover Torque Values ....................... 3
Figure 1 Exploded Parts Drawing ................. 6
Emerson warrants its Penberthy products as designed and manufactured by Emerson to be free of defects in the material and workmanship for a period of one year after the date of installation or eighteen months after the date of manufacture, whichever is earliest. Emerson will, at its option, replace or repair any products which fail during the warranty period due to defective material or workmanship.
THIS IS EMERSON’S SOLE WARRANTY AND IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED WHICH ARE HEREBY EXCLUDED, INCLUDING IN PARTICULAR ALL WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
This document and the warranty contained herein may not be modified and no other warranty, expressed or implied, shall be made by or on behalf of Emerson unless made in writing and signed by the General Manager or Director of Engineering of Emerson.
© 2017 Emerson. All Rights Reserved. VCIOM-12339-EN 19/06Emerson.com/FinalControl
PENBERTHY THREADED SIGHT WINDOWS
INSTALLATION, OPERATION AND MAINTENANCE MANUAL
1.0 ABOUT THE MANUAL
This manual has been prepared as an aid and guide for personnel involved in installation and maintenance. All instructions must be read and understood thoroughly before attempting any installation, operation, or maintenance.
WARNING
Always wear safety glasses when installing, servicing or operating a threaded sight window. Failure to follow any instruction could possibly result in a malfunction of the threaded sight window or glass breakage with resulting sudden release of pressure causing serious personal injury or property damage.
2.0 INTRODUCTION
Penberthy Threaded Sight Windows can be used anywhere that a ¼" to 3" piping "T" or a female NPT exists. Threaded Sight Windows offer a quick and inexpensive method of observing a fluid.
At a glance, the Threaded Sight Window allows for monitoring of:
• Liquid presence - change in level or volume of liquid in the viewing area
• Liquid color - change in tint or hue
• Liquid clarity - change in opacity, brightness or purity
The Threaded Sight Window provides a circular glass window for convenient fluid monitoring. The window assists the operation manager by creating a monitoring port for fluid process volumes, directions, and reactions without exposing the liquid to the external environment. The Threaded Sight Window is recommended for applications less than or equal to 285 psig (1.97 MPaG).
2.1 System Description
3.0 AVAILABLE MODELS
The Penberthy Threaded Sight Window consists of four basic components. Each component may vary slightly, depending on the desired physical and mechanical properties for the window. Use the exploded parts view in Section12.0 as additional reference material. Cover: the cover provides a machined surface
Standard materials of construction for the WTSL metal housings are carbon steel and stainless steel. Standard glass is tempered borosilicate with neoprene gasketing being the standard gasket for steel and Teflon
316STS. in which the glass and cushion are protectively seated. The threaded cover provides an effective means of "screw" compressing the
3.1 Design Ratings at Maximum and Minimum
Operating Temperatures
glass between the cover and body. Body: the threaded body provides rigid, in-line or vessel attachment capability. In addition, the body provides a flat, machined cavity in which the cover compresses the gasket.
Glass: the glass provides a window for in-line
WARNING
Never exceed these design ratings or application
data limits. Exceeding design ratings or
application data limits can cause serious personal
injury or property damage.
or vessel fluid observation. Gaskets: the gaskets are compressed by the cover to tightly seal the gap between the glass and the body to prevent leaking.
TABLE 1 - MAXIMUM DESIGN RATINGS FOR UNITS WITH TEMPERED GLASS
Gasket Material (psig [MPa])
Body Material Temperature Rating
Carbon steel -20°F [-29°C] to 100°F [38°C]
at 400°F [204°C]
316 Stainless steel -300°F [-184°C] to 100°F [38°C]
at 500°F [260°C]
Body Material Temperature Rating
Carbon steel -20°F [-29°C] to 100°F [38°C]
at 250°F [121°C] at 300°F [149°C] at 400°F [204°C]
316 Stainless steel -20°F [-29°C] to 100°F [38°C]
-65°F [-54°C] to 100°F [38°C]
-300°F [-184°C] to 100°F [38°C] at 250°F [121°C] at 300°F [149°C] at 400°F [204°C]
®
Teflon
285 [1.97] 200 [1.38] 275 [1.90] 170 [1.17]
Teflon®IFG-5500®Grafoil
285 [1.97]
200 [1.38] 275 [1.90]
195 [1.34]
IFG-5500
285 [1.97] 200 [1.38] 275 [1.90] 170 [1.17]
Gasket Material (psig [MPa])
285 [1.97]
200 [1.38]
275 [1.90]
195 [1.34]
®
285 [1.97]
230 [1.59]
275 [1.90]
215 [1.48]
®
®
for
Grafoil
285 [1.97] 200 [1.38] 275 [1.90] 170 [1.17]
Buna N
285 [1.97] 245 [1.69]
275 [1.90]
225 [1.55]
®
2