PENBERTHY FROST PROOF EXTENSION
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Before installation these instructions must be read fully and understood
PRODUCT WARRANTY
Emerson warrants its Penberthy products
as designed and manufactured to be free
of defects in the material and workmanship
for a period of one year after the date of
installation or eighteen months after the date
of manufacture, whichever is earliest. Emerson
will, at its option, replace or repair any products
which fail during the warranty period due to
defective material or workmanship.
Prior to submitting any claim for warranty
service, the owner must submit proof of
purchase to Emerson and obtain written
TABLE OF CONTENTS
Product warranty ................................................ 1
1 About the manual..................................... 2
2 Introduction ............................................. 2
2.1 Features and specifications ........................ 2
2.2 Design ratings at temperature ................... 2
2.3 Application data ........................................... 2
3
Inspection and performance confirmation
3.1 Receiving inspection .................................... 2
3.2 User's rating inspection .............................. 2
4 Installation ............................................... 3
4.1 Inspection and cleaning of gage glass ....... 3
4.2 Use of clear silicone rubber sealant .......... 3
4.3 Familiarization ............................................. 3
4.4 Installation of extension to gage ................. 3
5 Operation ................................................. 4
5.1 Pre-operational check ................................. 4
5.2 Operating ...................................................... 4
6 Maintenance ............................................ 4
6.1 Preventative maintenance ........................... 4
6.2 Preventative maintenance -
cleaningofextension ................................... 4
7 Removal – disassembly – reassembly..... 4
7.1 Disassembly ................................................. 4
7.2 Reassembly .................................................. 4
8 Disposal at end of useful life ................... 4
9 Telephone assistance .............................. 5
10 Exploded parts diagram .......................... 5
Tables and figures
Table 1 - Design ratings ................................... 2
Figure 1 - Exploded parts diagram ................... 5
authorization to return the product. Thereafter,
the product shall be returned to Emerson with
freight prepaid.
This warranty shall not apply if the product has
been disassembled, tampered with, repaired
or otherwise altered outside of the Emerson
factory, or if it has been subject to misuse,
neglect or accident.
.. 2
The responsibility of Emerson hereunder
is limited to repairing or replacing the
product at its expense. Emerson shall not be
liable for loss, damage or expenses
directly or indirectly to the installation or use
of its products, or from any other cause or
for consequential damages. It is expressly
understood that Emerson is not responsible
for damage or injury caused to other products,
buildings, personnel or property, by reason of
the installation or use of its products.
This is Emerson's sole warranty and in lieu of
all other warranties, expressed or implied which
are hereby excluded, including in particular all
warranties of merchantability or fitness for a
particular purpose.
This document and the warranty contained
herein may not be modified and no other
warranty, expressed or implied, shall be made
by or on behalf of Emerson unless made in
writing and signed by the company's general
manager or director of engineering.
related
valves.emerson.com
© 2017 Emerson. All Rights Reserved. VCIOM-04079-EN 17/05

PENBERTHY FROST PROOF EXTENSION
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
1 ABOUT THE MANUAL
This manual has been prepared as an aid and
guide for personnel involved in installation or
maintenance. All instructions must be read and
understood thoroughly before attempting any
installation, operation or maintenance.
Safety instructions
Emerson does not have any control over the
manner in which its frost proof extension is
handled, installed or used. Emerson cannot and
will not guarantee that a frost proof extension is
suitable for or compatible with the user's specific
application.
CAUTION
Safety glasses should be worn when installing a frost
proof extension. Failure to follow any instruction
could possibly result in a malfunction of the frost
proof extension resulting in loss of ability to read
liquid level, property damage or physical injury.
2 INTRODUCTION
2.1 Features and specifications
Penberthy frost proof extensions are designed
to be mounted readily and able to fit all vision
slot lengths of Series L, M, H and LC liquid level
gages. Penberthy frost proof extensions will
extend the viewing window glass out beyond the
range of frost build up.
2.2 Design ratings
Penberthy frost proof extensions are available
in three different extension sizes to handle the
temperature ranges as listed below:
3 INSPECTION AND PERFORMANCE
CONFIRMATION
3.1 Receiving inspection
Safety instructions
Exercise care in handling extension parts
to avoid scratching, denting or otherwise
damaging the polished edge of the extension.
Any marks on the polished edge, as well as dirt,
paint, or tape, will result in a reduction of ability
to read liquid level.
Upon receipt of frost proof extension, check
all components carefully for damage incurred
in shipping. If damage is evident or suspected,
do not attempt installation. Notify the carrier
immediately and request a damage inspection.
3.2 User’s rating inspection
The user should confirm that:
1. The frost proof extension size and length
conform to the description on the user's
purchase order.
2. The operating conditions described in
the purchase order agree with the actual
operating conditions at the installation site.
3. The actual operating conditions at the
installation site are within the application
data shown on the applicable technical data
sheet or product proposal referred to above.
4. The materials of construction of the frost
proof extension are compatible with the
surrounding atmosphere in the specific
application.
TABLE 1 - DESIGN RATINGS
Temperature range Extension size
-60°F [ -51°C] to 150°F [66°C] 2 inches [ 51 mm]
-140°F [ -96°C] to 150°F [66°C] 4 inches [102 mm]
-220°F [-140°C] to 150°F [66°C] 6 inches [152 mm]
2.3 Application data
Note: for specific application data within the
design limits stated above, the user should
refer to the product proposal or should request
the supply of the applicable technical data
sheet.
WARNING
Under no circumstances should these design
ratings or application data be exceeded.
Exceeding design ratings or application data may
cause severe physical injury or property damage.
2