Penberthy Frost proof extension, Penberthy-EN Manuals & Guides

PENBERTHY FROST PROOF EXTENSION
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
Before installation these instructions must be read fully and understood
PRODUCT WARRANTY
Emerson warrants its Penberthy products as designed and manufactured to be free of defects in the material and workmanship for a period of one year after the date of installation or eighteen months after the date of manufacture, whichever is earliest. Emerson will, at its option, replace or repair any products which fail during the warranty period due to defective material or workmanship.
Prior to submitting any claim for warranty service, the owner must submit proof of purchase to Emerson and obtain written
TABLE OF CONTENTS
Product warranty ................................................ 1
1 About the manual..................................... 2
2 Introduction ............................................. 2
2.1 Features and specifications ........................ 2
2.2 Design ratings at temperature ................... 2
2.3 Application data ........................................... 2
3
Inspection and performance confirmation
3.1 Receiving inspection .................................... 2
3.2 User's rating inspection .............................. 2
4 Installation ............................................... 3
4.1 Inspection and cleaning of gage glass ....... 3
4.2 Use of clear silicone rubber sealant .......... 3
4.3 Familiarization ............................................. 3
4.4 Installation of extension to gage ................. 3
5 Operation ................................................. 4
5.1 Pre-operational check ................................. 4
5.2 Operating ...................................................... 4
6 Maintenance ............................................ 4
6.1 Preventative maintenance ........................... 4
6.2 Preventative maintenance -
cleaningofextension ................................... 4
7 Removal – disassembly – reassembly..... 4
7.1 Disassembly ................................................. 4
7.2 Reassembly .................................................. 4
8 Disposal at end of useful life ................... 4
9 Telephone assistance .............................. 5
10 Exploded parts diagram .......................... 5
Tables and figures
Table 1 - Design ratings ................................... 2
Figure 1 - Exploded parts diagram ................... 5
authorization to return the product. Thereafter, the product shall be returned to Emerson with freight prepaid.
This warranty shall not apply if the product has been disassembled, tampered with, repaired or otherwise altered outside of the Emerson factory, or if it has been subject to misuse, neglect or accident.
.. 2
The responsibility of Emerson hereunder is limited to repairing or replacing the product at its expense. Emerson shall not be liable for loss, damage or expenses directly or indirectly to the installation or use of its products, or from any other cause or for consequential damages. It is expressly understood that Emerson is not responsible for damage or injury caused to other products, buildings, personnel or property, by reason of the installation or use of its products.
This is Emerson's sole warranty and in lieu of all other warranties, expressed or implied which are hereby excluded, including in particular all warranties of merchantability or fitness for a particular purpose.
This document and the warranty contained herein may not be modified and no other warranty, expressed or implied, shall be made by or on behalf of Emerson unless made in writing and signed by the company's general manager or director of engineering.
related
valves.emerson.com
© 2017 Emerson. All Rights Reserved. VCIOM-04079-EN 17/05
PENBERTHY FROST PROOF EXTENSION
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
1 ABOUT THE MANUAL
This manual has been prepared as an aid and guide for personnel involved in installation or maintenance. All instructions must be read and understood thoroughly before attempting any installation, operation or maintenance.
Safety instructions
Emerson does not have any control over the manner in which its frost proof extension is handled, installed or used. Emerson cannot and will not guarantee that a frost proof extension is suitable for or compatible with the user's specific application.
CAUTION
Safety glasses should be worn when installing a frost proof extension. Failure to follow any instruction could possibly result in a malfunction of the frost proof extension resulting in loss of ability to read liquid level, property damage or physical injury.
2 INTRODUCTION
2.1 Features and specifications
Penberthy frost proof extensions are designed to be mounted readily and able to fit all vision slot lengths of Series L, M, H and LC liquid level gages. Penberthy frost proof extensions will extend the viewing window glass out beyond the range of frost build up.
2.2 Design ratings
Penberthy frost proof extensions are available in three different extension sizes to handle the temperature ranges as listed below:
3 INSPECTION AND PERFORMANCE CONFIRMATION
3.1 Receiving inspection
Safety instructions
Exercise care in handling extension parts to avoid scratching, denting or otherwise damaging the polished edge of the extension. Any marks on the polished edge, as well as dirt, paint, or tape, will result in a reduction of ability to read liquid level.
Upon receipt of frost proof extension, check all components carefully for damage incurred in shipping. If damage is evident or suspected, do not attempt installation. Notify the carrier immediately and request a damage inspection.
3.2 User’s rating inspection
The user should confirm that:
1. The frost proof extension size and length conform to the description on the user's purchase order.
2. The operating conditions described in the purchase order agree with the actual operating conditions at the installation site.
3. The actual operating conditions at the installation site are within the application data shown on the applicable technical data sheet or product proposal referred to above.
4. The materials of construction of the frost proof extension are compatible with the surrounding atmosphere in the specific application.
TABLE 1 - DESIGN RATINGS
Temperature range Extension size
-60°F [ -51°C] to 150°F [66°C] 2 inches [ 51 mm]
-140°F [ -96°C] to 150°F [66°C] 4 inches [102 mm]
-220°F [-140°C] to 150°F [66°C] 6 inches [152 mm]
2.3 Application data Note: for specific application data within the
design limits stated above, the user should refer to the product proposal or should request the supply of the applicable technical data sheet.
WARNING
Under no circumstances should these design ratings or application data be exceeded. Exceeding design ratings or application data may cause severe physical injury or property damage.
2