P&E Microcomputer Systems, Inc. reserves the right to make changes without further notice to any products herein to improve reliability, function, or
design. P&E Microcomputer Systems, Inc. does not assume any liability arising out of the application or use of any product or circuit described herein.
This software and accompanying documentation are protected by United States Copyright law and also by International Treaty provisions. Any use of this
software in violation of copyright law or the terms of this agreement will be prosecuted.
All the software described in this document is copyrighted by P&E Microcomputer Systems, Inc. Copyright notices have been included in the software.
P&E Microcomputer Systems authorizes you to make archival copies of the software and documentation for the sole purpose of back-up and protecting
your investment from loss. Under no circumstances may you copy this software or documentation for the purpose of distribution to others. Under no
conditions may you remove the copyright notices from this software or documentation.
This software may be used by one person on as many computers as that person uses, provided that the software is never used on two computers at the
same time. P&E expects that group programming projects making use of this software will purchase a copy of the software and documentation for each
user in the group. Contact P&E for volume discounts and site licensing agreements.
P&E Microcomputer Systems does not assume any liability for the use of this software beyond the original purchase price of the software. In no event will
P&E Microcomputer Systems be liable for additional damages, including any lost profits, lost savings or other incidental or consequential damages arising
out of the use or inability to use these programs, even if P&E Microcomputer Systems has been advised of the possibility of such damage.
By using this software, you accept the terms of this agreement.
1.2.2Cyclone Control Suite Advanced Features License .................................................................................................... 10
1.2.3SDHC Port Activation License..................................................................................................................................... 10
2QUICK START GUIDE FOR SAP OPERATION.......................................................................................11
2.1Installing The Cyclone Software....................................................................................................................11
2.2Setting Up The Cyclone Hardware................................................................................................................11
2.3Creating A Stand-Alone Programming Image ...............................................................................................13
2.3.1Advanced Features .....................................................................................................................................................16
3.5Cyclone System Power .................................................................................................................................19
3.6RS232 Communication (Serial Port) .............................................................................................................19
3.14Cyclone Time / Real Time Clock ...................................................................................................................21
4.2.2Power provided by the Cyclone to the debug cable ....................................................................................................36
4.2.3External Power passed through the Cyclone and out 2.5 mm barrel port...................................................................37
4.2.4External Power passed through the Cyclone to the debug cable................................................................................37
4.2.5Power provided by the Cyclone and out 2.5 mm barrel port .......................................................................................38
5.1.4Error Information Icon.................................................................................................................................................. 40
5.1.5AUX Button (Appears If Configured) ...........................................................................................................................40
6.1.1Specify CPU Manufacturer..........................................................................................................................................49
6.1.5Communication Mode and Rate Settings....................................................................................................................56
6.1.6Target Voltage and Power Settings.............................................................................................................................56
6.1.9FX Exclusive Features ................................................................................................................................................59
6.1.10Store Image To Cyclone..............................................................................................................................................59
6.1.11Store Image To Disk....................................................................................................................................................60
7.1Operation Via Start Button ............................................................................................................................63
7.4.1Error Information Icon.................................................................................................................................................. 65
7.4.2AUX Button (Appears If Configured) ...........................................................................................................................65
8.2Cyclone Control SDK ....................................................................................................................................69
8.2.2Backwards Compatibility With Classic Cyclone Control API ....................................................................................... 70
8.2.3Getting Started with the Cyclone Control DLL............................................................................................................. 70
8.3Cyclone Control Console...............................................................................................................................87
8.4Cyclone Control GUI .....................................................................................................................................90
8.4.2The Control Tabs......................................................................................................................................................... 92
8.4.3The Status and Error Window: ....................................................................................................................................97
9.2.4Using Command Line Parameters Inside a .CFG File ..............................................................................................107
10.4Connecting The Cyclone Device .................................................................................................................112
10.4.1Connecting the Cyclone to the PC over a network....................................................................................................112
10.4.2Connecting Cyclone-to-PC via an Ethernet cable.....................................................................................................113
10.5Cyclone IP Setup Via LCD Menu ................................................................................................................113
11.2Encrypting/Decrypting a Programming Image.............................................................................................116
11.3What is Encrypted in an eSAP File, and How .............................................................................................116
11.4Managing Encryption For Production Programming ...................................................................................117
11.4.1Provisioning a Cyclone with an ImageKey ................................................................................................................117
11.4.2Removing ImageKeys From A Cyclone .................................................................................................................... 119
11.4.3Loading and Programming with Encrypted SAP Images .......................................................................................... 119
11.4.4Encryption Status of SAP Images .............................................................................................................................120
11.5Safer Production That's Easy To Implement...............................................................................................121
12AUTOMATIC SERIAL NUMBER MECHANISM......................................................................................122
12.2.1Startup And File Options ...........................................................................................................................................123
12.2.2Serial Number File.....................................................................................................................................................124
12.2.3Serial File Unique ID ................................................................................................................................................. 124
12.2.4Serial File Name To Display......................................................................................................................................124
12.2.6Number of Bytes in Serial Number............................................................................................................................124
12.2.9Serial Number Bytes as Hex .....................................................................................................................................124
12.2.12Binary, Numeric, Constant, Alpha Upper, Alpha Lower, and Printable .....................................................................125
12.2.13Byte Program Order ..................................................................................................................................................125
12.3.1Serial File Example ................................................................................................................................................... 125
12.4Serial Number Handling ..............................................................................................................................126
12.4.1Invoking A Serial File Via Command-Line.................................................................................................................127
12.5Creating A SAP Image With Multiple Serial Numbers.................................................................................127
12.6Shared Serial Numbers ...............................................................................................................................128
13.1How to Install Your License.........................................................................................................................133
14.1My Cyclone Is Non-Responsive, Is There A Way To Re-Activate It?..........................................................138
14.1.1What Is Bootloader Mode?........................................................................................................................................138
14.1.2When Is Bootloader Mode Used? ............................................................................................................................. 138
14.1.3How Is Bootloader Mode Entered? ........................................................................................................................... 138
14.2I Received A “SAP Image Needs To Be Updated” Error Using A Next-Gen Cyclone, How Do I Update? .138
14.2.1How Do I Use SAP_Convert_Console.exe? ............................................................................................................. 138
14.3When Trying To Install The CYCLONE Software, A Popup WDREG Error Occurs Telling Me That There Are
Open Devices Using WinDriver...................................................................................................................139
15.1Debug Mode Communication Related Errors..............................................................................................140
15.2SAP Image Handling Related Errors...........................................................................................................140
15.3SAP Communication Handling Related Errors............................................................................................141
15.4SAP Algorithm Header Operation Handling Related Errors ........................................................................141
15.5SAP Operation Related Errors ....................................................................................................................141
15.6SAP Blank Check Range and Module Related Errors ................................................................................141
15.7SAP Erase Range and Module Related Errors ...........................................................................................141
15.8SAP Program Byte, Word, and Module Related Errors...............................................................................141
15.9SAP Verify Checksum Related Errors.........................................................................................................142
15.10SAP Verify Range and Module Related Errors ...........................................................................................142
15.11SAP User Function Related Errors..............................................................................................................142
15.12SAP Trim Related Errors.............................................................................................................................142
15.14Operation Security Related Errors ..............................................................................................................143
15.16Serial Number Related Errors .....................................................................................................................144
15.17Download Count Related Errors..................................................................................................................144
PEmicro's Cyclone LC production programmers are powerful, fast, and feature rich in-circuit
programming solutions. PEmicro offers two models which have the same feature set and only vary
by the devices supported.
Part# CYCLONE-LC-ARM supports a wide variety of ARM Cortex devices.
Part# CYCLONE-LC-UNIV supports those ARM Cortex devices as well as the following NXP
device families: Kinetis, LPC, S32, MPC55xx-57xx), MPC5xx/8xx, DSC, S12Z, RS08, S08, HC08,
HC(S)12(X), ColdFire, and STMicroelectronics’ SPC5 & STM8.
Note:PEmicro refreshed Cyclone names and part numbers in July 2019. The part numbers listed on
earlier Cyclones will differ slightly. CYCLONE is now called Cyclone LC, however the hardware
has not changed.
Figure 1-1: Cyclone LC Supported Architectures
Cyclone LC programmers are designed to withstand the demands of a production environment.
They are Stand-Alone Programmers (SAP) that can be operated manually or used to host
automated programming. In manual SAP mode the Cyclone is operated using the touchscreen
LCD Menu and/or the Start button. Host-controlled SAP mode, for automated programming, is
accomplished using the Cyclone Control Suite.
1.1Cyclone Feature Comparison
In addition to Cyclone LC programmers, PEmicro offers Cyclone FX programmers that include
enhanced speed, storage, and security features, plus advanced Cyclone control/automation
features which make them an incredibly powerful and versatile solution. See CHAPTER 16 - CYCLONE FEATURE OVERVIEW / COMPARISON for a CYCLONE feature overview and
comparison with the Cyclone FX programmers.
1.2Advanced Feature Licenses
PEmicro offers Cyclone LC users the flexibility to add many of the advanced security, automation/
control, and expandable memory features included with the Cyclone FX. These features can be
added by purchasing and installing the appropriate activation license.
1.2.1ProCryption Security License
The ProCryption Security License offers two extremely valuable security features:
User Manual For Cyclone LC Programmers9
1. RSA/AES encryption of programming images
Users create unique ImageKeys which are used to encrypt their programming images.
SAP images encrypted in this way can only be loaded onto a Cyclone or programmed with
a Cyclone if that Cyclone has been provisioned with the identical ImageKey.
2. The ability to restrict image programming by programming count or date range.
Programming restrictions on images are easily configured during the image creation
process.
Together these security features help keep the user’s valuable IP safe. The user should refer to
CHAPTER 11 - SAP IMAGE ENCRYPTION for more information on encrypted programming
images. Image restrictions are described in Section 6.1.8.2 - Image Restrictions.
1.2.2Cyclone Control Suite Advanced Features License
Cyclone LC programmers include a basic version of the Cyclone Control Suite. The Advanced
Cyclone Control Suite Update license enables additional features that allow the user to:
•Add/Remove/Update many images in the Cyclone (Console, SDK, GUI)
•Gang program: Simultaneously control multiple Cyclones via the USB, Serial, or Ethernet
connections
•Program (and read) Dynamic Data in addition to fixed image data
•Access a Remote Display for the Cyclone
•Read/write Cyclone properties
•Read Image and target Properties and Status
•Compare images against a SAP file
This gives the user much more control and flexibility during the production process. The user
should refer to Section 8.1 - Overview Of Cyclone Control Suite for more information.
1.2.3SDHC Port Activation License
The SDHC Port Activation License activates the SDHC port of the Cyclone LC. This allows the
user expand the storage capacity of the Cyclone by loading images onto SDHC cards. SDHC
cards can hold more and larger images than a Cyclone LC programmer can normally
accommodate. The Cyclone display and management tools allow the user to easily distinguish
between “internal” and “external” images. Section 6.2 - Managing Multiple SAP Images displays
an example of how external images are differentiated.
User Manual For Cyclone LC Programmers10
2QUICK START GUIDE FOR SAP OPERATION
This guide will allow the user to set up and program a simple Stand-Alone Programming (SAP) image
with the Cyclone by completing the following steps.
•Installing the Cyclone software
•Setting up the Cyclone hardware
•Creating a stand-alone programming image
•Launching Cyclone programming
This guide is intended as a supplement to the Cyclone’s User Manual, which contains in-depth
information about the topics covered here and much more.
2.1Installing The Cyclone Software
First, the Cyclone software should be installed on the user’s PC. It can be downloaded from the
Support & Downloads tab on the pemicro.com Cyclone product page, or directly from https://
www.pemicro.com/downloads/download_file.cfm?download_id=481.
Once the software is downloaded, the user should install it on their PC. If Cyclone software is already
installed on the PC, it is recommended that the old installation be removed before the user installs the
latest software.
2.2Setting Up The Cyclone Hardware
Step 1. Configure Cyclone power settings
The Cyclone has several different power configurations. The label on the bottom of the Cyclone
indicates the appropriate Jumper settings for each. The user should install the Jumpers as indicated
for their desired power configuration.
The Jumpers are located underneath the Cyclone’s access panel. They are labeled “Power Jumpers.”
and numbered from 1-4. The Cyclone-LC-ARM is shown in the example below; the jumper location will
be similar for all Cyclone models.
User Manual For Cyclone LC Programmers11
If power is provided via the Cyclone, the user may need to configure the programming image
accordingly. Image creation and configuration is discussed in Section 2.3 - Creating A Stand-Alone Programming Image.
For more information on the various power configurations, the user should refer to their Cyclone’s User
Manual. There is a also a blog post that covers this topic at: http://www.pemicro.com/blog/
index.cfm?post_id=121
Step 2. Connect Cyclone to a PC (for programming image setup)
The Cyclone programmer should be connected to the PC via USB, Serial, or Ethernet. Cables for each
of these options are included with the Cyclone.
Note:An Ethernet connection requires IP setup on the Cyclone unit; please refer to the Cyclone’s User
Manual for more information.
Step 3. Connect Cyclone to target
A ribbon cable should be connected from the appropriate Cyclone header (located under the Cyclone’s
access panel) to the header for your target device. Ribbon cables are provided with the Cyclone.
Step 4. Plug in power to the Cyclone
The provided power supply should be plugged into the System Power jack of the Cyclone programmer.
Other power connections should be made according to the power configuration selected in Step 1.
On power-up the user may need to agree to a firmware update on the Cyclone unit.
User Manual For Cyclone LC Programmers12
2.3Creating A Stand-Alone Programming Image
A stand-alone programming (SAP) image is the result of pre-processing the programming algorithms,
data to be programmed, programming options, and scripted programming commands. These are
combined into a single encrypted file. This SAP image can then be loaded onto the Cyclone and used
to program, without need for the Cyclone to be connected to a PC.
The Cyclone Image Creation Utility, shown below, allows the user to configure and save SAP images.
A simple programming image can be created in 6 steps:
Step 1. Run Cyclone Image Creation Utility
Step 2. Select Device Manufacturer & Device
Step 3. Set Up Programming Sequence
Step 4. Add Basic Programming Commands
Step 5. Configure Additional Settings
Step 6. Save SAP Image To Cyclone
User Manual For Cyclone LC Programmers13
The following instructions walk the user through each of these steps:
Step 1. Run Cyclone Image Creation Utility
CreateImage.exe is in the “ImageCreation” folder, in the location where the Cyclone software was
installed. For an in-depth description of the Cyclone Image Creation Utility, see Section 6.1 - Cyclone
Image Creation Utility.
Step 2. Select Device Manufacturer and Device
Specify CPU Manufacturer and Select New Device are used to choose the manufacturer of the target
device, and then the specific device or architecture.
Step 3. Programming Sequence Setup
The user should double-click on CM in the Programming Sequence window to choose the appropriate
Algorithm for the target device. They can navigate to the algorithm using the dialog provided.
Based on the algorithm that was selected, additional commands will be made available in the box of
programming commands on the left.
The user should then double-click on the SS command to specify the Object Code.
User Manual For Cyclone LC Programmers14
Step 4. Adding Basic Programming Commands
The user should then add other basic programming commands, using the list of commands on the left
side of the Programming Sequence area. The arrow and buttons allow the user to add, remove, and
re-sequence the commands, in the box on the right. As an example, some basic commands might be
•Erase
•Program
•Verify
Note:Launch Script Wizard can also be used to quickly complete Steps 3 and 4.
Step 5. Other Settings
The user should then specify any other settings that the SAP image should contain in order to program
correctly, such as
•Communication SWD vs JTAG
•Shift frequency
•Target Power and Voltage Settings
User Manual For Cyclone LC Programmers15
These settings can be made using the corresponding areas of the Cyclone Image Creation Utility.
Step 6. Save SAP image to Cyclone
The user should then save the SAP image onto the Cyclone by clicking the button to save to “Cyclone
Only” or “Cyclone & Disk.” The image will be automatically selected as the current SAP image on the
Cyclone.
2.3.1Advanced Features
Cyclone programmers can take advantage of several advanced features that are beyond the scope of
this Getting Started guide, such as RSA/AES encrypted programming images, programming
restrictions on images (see Section 6.1.8 - ProCryption Security License Features), and use of a
barcode scanner to launch programming (see CHAPTER 12 - USING A BARCODE SCANNER TO SELECT AN IMAGE & INITIATE PROGRAMMING). CYCLONE FX programmers include all of these
features, and CYCLONE programmers can use many of these features with the appropriate activation
license.
2.4Launching Cyclone Programming
There are three ways to launch programming.
1. Cyclone Start Button Press - The user simply presses the Start button located on top of
the Cyclone programmer.
2. Cyclone Control Console (command-line utility) - The user writes a script that specifies
parameters and initiates programming using the command line. More information is avail-
User Manual For Cyclone LC Programmers16
able in the Cyclone’s User manual or at: http://www.pemicro.com/blog/
index.cfm?post_id=142
3. SDK - The SDK is a software library that is used in conjunction with the user’s own code.
The user writes a customer application that uses this library of functions to launch programming. More information is available in the Cyclone’s User Manual, or at: http://
www.pemicro.com/blog/index.cfm?post_id=139
The “Success” or “Error” LED will illuminate to let the user know the result of programming.
Note:If programming is unsuccessful when using this quick start procedure, the user may instead wish
to use the included PROG software for their target device. The PROG software allows the user to
manually walk through the programming procedure step by step, which may help determine which
part of setup or programming function is causing difficulty.
User Manual For Cyclone LC Programmers17
3CYCLONE LC HARDWARE
The following is an overview of the features and interfaces of Cyclone LC programmers. Many of
these interfaces are labeled on the underside of the plastic case.
3.1Touchscreen LCD
The LCD Touchscreen displays information about the Cyclone’s configuration and the
programming process, and also allows the user to navigate the Cyclone’s menus. The location of
the Touchscreen LCD is shown in Figure 3-1.
3.2LED Indicators
The LED indicators for Error or Success will illuminate depending on the results of the
programming process and provide a clear visual indication of the results. The location of the LED
Indicators is shown in Figure 3-1.
3.3Start Button
The Start Button can be used to begin the programming process manually, provided that the
Cyclone is properly configured. The location of the Start Button is shown in Figure 3-1.
3.4Access Panel
The Access Panel can easily be opened to allow the user to connect/disconnect ribbon cables
from the headers, or to configure the Cyclone’s Power Jumpers to select one of the available
Power Management setups. The location of the Access Panel is shown in Figure 3-1; a layout of
the headers and jumpers beneath the Access Panel is shown in Figure 3-5.
Figure 3-1: Cyclone LC Top View
User Manual For Cyclone LC Programmers18
Figure 3-2: Cyclone LC Right Side View
3.5Cyclone System Power
The Cyclone LC programmer requires a regulated 6V DC Center Positive power supply with 2.5/
5.5mm female plug. Cyclones derive power from the Power Jack located on the right end of the
unit. The location of Cyclone System Power is shown in Figure 3-2.
3.6RS232 Communication (Serial Port)
The Cyclone LC provides a DB9 Female connector to communicate with a host computer through
the RS232 communication (115200 Baud, 8 Data bits, No parity, 1 Stop bit). The location of the
Serial Port is shown in Figure 3-2.
3.7Ethernet Communication
The Cyclone LC provides a standard RJ45 socket to communicate with a host computer through
the Ethernet Port (10/100 BaseT). The location of the Ethernet Port is shown in Figure 3-2.
3.8USB Communications
The Cyclone LC provides a USB connector for Universal Serial Bus communications between the
Cyclone and the host computer. The Cyclone LC is a USB 2.0 Full-Speed compliant device. The
location of the USB Port is shown in Figure 3-2.
3.9Electromechanical Relays
Inside the Cyclone LC programmer, two electromechanical relays are used to cycle target power.
The specifications of the relays are as following:
Maximum switched power: 30W or 125 VA
Maximum switched current: 1A
Maximum switched voltage: 150VDC or 300VAC
UL Rating: 1A at 30 VDC
1A at 125 VAC
PEmicro only recommends switching DC voltages up to 24 Volts.
User Manual For Cyclone LC Programmers19
3.10Power Connectors
The Cyclone LC programmers provide a Target Power Supply Input Jack and a Target Power
Supply Output Jack with 2.5/5.5 mm Pin Diameter. The power jacks are connected or
disconnected by two electromechanical relays. When connected, the Center Pin of the Target
Power Supply Input Jack is connected to the Center Pin of the Target Power Supply Output Jack.
When disconnected, both terminals of the Target Power Supply Output Jack are connected to
GND via a 1W, 100 Ohm resistor. The location of Target Power In is shown in Figure 3-3, and the
location of Target Power Out is shown in Figure 3-3.
3.11Reset Button
The Reset Button performs a hard reset of the Cyclone system. The location of the Reset Button is
shown in Figure 3-3.
Figure 3-3: Cyclone LC Front Side View
Figure 3-4: Cyclone LC Rear Side View
3.12SDHC Port
Note:The SDHC port is activated on all Cyclone FX programmers, and may be activated on Cyclone
LC programmers via purchase of the SDHC Port Activation License.
The SDHC port allows the user to store programming images that are, individually or collectively,
larger than the Cyclone’s internal memory. It also makes it quicker and more convenient to swap
programming images. PEmicro offers certified SDHC cards on our website at pemicro.com. The
location of the SDHC Port is shown in Figure 3-4.
Programming images are managed on the SD card in exactly the same way as they are in the
Cyclone’s internal memory. Please see Section 6.2 - Managing Multiple SAP Images for more
information about using the Manage Images utility.
Note:To view detailed information about the status of the SDHC card/port, tap the icon bar at the top of
the touchscreen menu. This status can provide you with relevant information if you are
User Manual For Cyclone LC Programmers20
encountering any difficulty while trying to use an SDHC card.
3.13Optional Oscillator (MON08 Only)
Cyclone LC programmers with MON08 support (PEmicro Part# CYCLONE-LC-UNIV only)
provide a software configurable 9.8304MHz or 4.9152 MHz oscillator clock signal to Pin 13 of the
MON08 Connector. The user may use this clock signal to overdrive the target RC or crystal
circuitry. If this signal is not used, just leave Pin 13 of the target MON08 header unconnected.
Please note that if the target already uses an oscillator as its clock, the Cyclone will NOT be able to
overdrive it. The clock should have sufficient drive to be used with a target system even if the
target system has an RC circuit or crystal connected.
3.14Cyclone Time / Real Time Clock
Cyclone LC programmers are equipped with a Real Time Clock (RTC) module designed to keep
accurate timing even when the Cyclone is turned off.
The Date & Time are displayed on the home screen. Date/Time settings can be configured by
navigating to the following menu using the touchscreen display:
Main Menu / Configure Cyclone Settings / Configure Time Settings
For more information on the available configuration options, see Section 5.2.3.3 - Configure
Time Settings (Cyclone Time / Real Time Clock).
3.15Power Jumper Settings
The Power Jumpers must be set differently for various power management options that the
Cyclone LC offers. If the target is being powered independently of the Cyclone LC, all pins in the
Power Jumpers header must instead be left unpopulated. To reveal the Power Jumpers header, lift
the access panel on the left end of the Cyclone LC. The location is indicated as Power Jumpers in
Figure 3-5. Please see CHAPTER 4 - TARGET POWER MANAGEMENT for the correct jumper
settings for the Cyclone’s power management options. A quick guide to these settings is also
located on the underside label of the Cyclone LC.
3.16Debug Connectors
When purchasing a Cyclone LC programmer, the user is able to choose between two part
numbers, each corresponding to a different level of device support. See the sticker on the
underside of the Cyclone to determine the PEmicro part# for your specific Cyclone LC
programmer.
PEmicro Part# CYCLONE-LC-ARM supports ARM Cortex devices only, so this programmer
provides one shrouded, un-keyed, 0.100-inch pitch dual row 0.025-inch square header, and two
shrouded, keyed 0.050-inch pitch dual row mini headers.
PEmicro Part# CYCLONE-LC-UNIV supports ARM Cortex devices and additionally supports
target connections to many 8-/16-/32-bit NXP architectures, so this programmer provides six
shrouded, un-keyed, 0.100-inch pitch dual row 0.025-inch square headers, and two shrouded,
keyed 0.050-inch pitch dual row mini headers.
To reveal the headers and connect/disconnect ribbon cables, lift the access panel on the left end
of the Cyclone. Each header is designated for one or more specific target architectures, as
indicated in Figure 3-5.
User Manual For Cyclone LC Programmers21
Figure 3-5: Target Headers & Power Jumpers (CYCLONE-LC-UNIV vs.CYCLONE-LC-ARM)
Mechanical drawings are shown below whose dimensions are representative of the pin size and
spacing of these headers.
Note:The number of pins depicted in the mechanical drawings may differ from the Cyclone headers; the
drawings are provided simply to demonstrate pin size and spacing.
Figure 3-6: 20-Pin Un-Keyed Header Dimensions
User Manual For Cyclone LC Programmers22
Figure 3-7: Mini 10-Pin and Mini 20-Pin Keyed Header Dimensions
3.17Target Headers For Part# CYCLONE-LC-ARM
PEmicro Part# CYCLONE-LC-ARM features 3 ports labeled A-C.
3.17.1PORT A: 10-Pin Keyed Mini Connector (Kinetis, S32 (ARM), other PEmicro-Supported ARM
devices)
3.17.1.1 JTAG Pin Assignments
The Cyclone provides a keyed 10-pin 0.050-inch pitch double row connector for ARM targets. The
location of the this header is indicated as PORT A in Figure 3-5. The 10-pin keyed mini connector
pin definitions for JTAG mode are as follows:
10-Pin Keyed Mini Connector JTAG Mode Pin Assignments
If high-performance options are available for the selected device they will appear in the “Shift
Frequency in MHz” drop-down. Cyclone FX programmers are capable of high-performance
communications when using certain ARM Cortex targets in SWD mode.
Note:Cyclone LC programmers cannot currently take advantage of high-performance options, although
the frequencies appear in the display.
Figure 3-9: High-Performance Options (FX ONLY)
3.17.2PORT B: 20-Pin Keyed Mini Connector (Kinetis, S32 (ARM), other PEmicro-Supported ARM
devices)
3.17.2.1 JTAG Mode Pin Assignments
The Cyclone provides a keyed 20-pin 0.050-inch pitch double row connector for ARM targets. The
location of the this header is indicated as PORT B in Figure 3-5. The 20-pin keyed mini connector
pin definitions for JTAG mode are as follows:
20-Pin Keyed Mini Connector JTAG Mode Pin Assignments
If high-performance options are available for the selected device they will appear in the “Shift
Frequency in M Hz” drop-down. Cyclone FX programmers are capable of high-performance
communications when using certain ARM Cortex targets in SWD mode.
Note:Cyclone LC programmers cannot currently take advantage of high-performance options, although
the frequencies appear in the display.
Figure 3-11: High-Performance Options (FX ONLY)
3.17.3PORT C: 20-Pin Debug Connector (Kinetis, S32 (ARM), other PEmicro-Supported ARM
devices)
3.17.3.1 JTAG Mode Pin Assignments
The Cyclone provides a 20-pin 0.100-inch pitch double row connector for ARM targets. The
location of the this header is indicated as PORT Cunder Part# CYCLONE-LC-ARM in Figure 3-5.
The 20-pin standard connector pin definitions for JTAG mode are as follows:
20-Pin Standard Connector JTAG Mode Pin Assignments
If high-performance options are available for the selected device they will appear in the “Shift
Frequency in MHz” drop-down. Cyclone FX programmers are capable of high-performance
communications when using certain ARM Cortex targets in SWD mode.
Note:Cyclone LC programmers cannot currently take advantage of high-performance options, although
the frequencies appear in the display.
Figure 3-13: High-Performance Options (FX ONLY)
3.18Target Headers For Part# CYCLONE-LC-UNIV
PEmicro Part# CYCLONE-LC-UNIV features 6 ports labeled A-H.
3.18.1PORT A: 10-Pin Keyed Mini Connector (Kinetis, S32 (ARM), other PEmicro-Supported ARM
devices)
3.18.1.1 JTAG Mode Pin Assignments
The Cyclone provides a keyed 10-pin 0.050-inch pitch double row connector for ARM targets. The
location of the this header is indicated as PORT A in Figure 3-5. The 10-pin keyed mini connector
pin definitions for JTAG mode are as follows:
10-Pin Keyed Mini Connector JTAG Mode Pin Assignments
If high-performance options are available for the selected device they will appear in the “Shift
Frequency in MHz” drop-down. Cyclone FX programmers are capable of high-performance
communications when using certain ARM Cortex targets in SWD mode.
Note:Cyclone LC programmers cannot currently take advantage of high-performance options, although
the frequencies appear in the display.
Figure 3-15: High-Performance Options (FX ONLY)
3.18.2PORT B: 20-Pin Keyed Mini Connector (Kinetis, S32 (ARM), other PEmicro-Supported ARM
devices)
3.18.2.1 JTAG Mode Pin Assignments
The Cyclone provides a keyed 20-pin 0.050-inch pitch double row connector for ARM targets. The
location of the this header is indicated as PORT B in Figure 3-5. The 20-pin keyed mini connector
pin definitions for JTAG mode are as follows:
20-Pin Keyed Mini Connector JTAG Mode Pin Assignments
If high-performance options are available for the selected device they will appear in the “Shift
Frequency in MHz” drop-down. Cyclone FX programmers are capable of high-performance
communications when using certain ARM Cortex targets in SWD mode.
Note:Cyclone LC programmers cannot currently take advantage of high-performance options, although
The Cyclone provides a standard 14-pin 0.100-inch pitch dual row 0.025-inch square header for
MPC55xx-57xx, DSC (MC56F8xxx), S32R, or STMicroelectronics’ SPC5 targets. The location of
the this header is indicated as PORT C in Figure 3-5.
MPC55xx-57xx, SPC5, or S32 (Power) Pinout
TDI12GND
TDO34GND
TCK56GND
NC78NC
User Manual For Cyclone LC Programmers28
RESET910TMS
VDDE71112GND
RDY1314JCOMP
DSC Pinout
TDI12GND
TDO34GND
TCK56GND
NC78NC/KEY
RESET910TMS
VDD1112GND
NC*1314TRST
*The pin is reserved for internal use within the PEmicro interface.
3.18.3.1 BERG14-to-MICTOR38 Optional Connector
PEmicro offers a 14-pin BERG to 38-pin MICTOR adapter, sold separately, that may be used on
Port C of the Cyclone LC. The PEmicro part number is BERG14-TO-MICTOR38.
The Cyclone provides a standard 26-pin 0.100-inch pitch dual row 0.025-inch square header for
ColdFire MCF52xx/53xx/54xx family of microprocessors. This port connects to the target hardware
using either the ColdFire extension cable for synchronous ColdFire targets such as MCF5272 &
MCF5206E (PEmicro part# CABLE-CF-ADAPTER, sold separately), or a standard 26-pin ribbon
cable for asynchronous ColdFire targets (included). Please refer to each processor’s user manual
to identify whether it is a synchronous or asynchronous interface. The location of the this header is
indicated as PORT D in Figure 3-5.
ColdFire V2/3/4 Pinout
N/C12BKPT
GND34DSCLK
GND56NC*
RESET78DSI
VCC910DSO
GND1112PST3
PST21314PST1
PST01516DDATA3
DDATA21718DDATA1
User Manual For Cyclone LC Programmers29
DDATA01920GND
N/C2122N/C
GND2324CLK
VCC2526TEA
*The pin is reserved for internal use within the PEmicro interface.
The ColdFire adapter for Synchronous targets and ribbon cable for Asynchronous targets is
pictured below:
Figure 3-20: ColdFire Ribbon Cable (for asynchronous ColdFire targets, included with Cyclone)
3.18.5PORT E: 16-Pin Debug Connector (MON08)
The Cyclone provides a 16-pin 0.100-inch pitch double row connector for MON08 targets. The
location of the this header is indicated as PORT E in Figure 3-5. The MON08 header adopts the
standard pin-out from MON08 debugging with some modifications. The general pin-out is as
follows: