Pelco UDI5000-MTRX, UDI5000-MTRX-US Specsheet

PRODUCT SPECIFICATION
video management solutions
Endura® UDI5000-MTRX Universal Device Interface
INTEGRATION PLATFORM FOR THIRD-PARTY SYSTEMS AND MATRIX KEYBOARDS
Product Features
User-Friendly Web-Based Administration
Supports Three Operation Modes: ASCII, Matrix Digital Decoder, and
Virtual Matrix
Diagnostics Available Through Self-Contained Endura
and Simple Network Management Protocol (SNMP)
®
Diagnostics
The UDI5000-MTRX provides users with a powerful means by which to leverage investments in legacy analog systems and integrations, while affording customers the benefits of today’s IP and megapixel camera technologies. The UDI5000-MTRX supports three operating modes: ASCII mode, Matrix Digital Decoder mode (MDD), and Virtual Matrix mode (V9700). In ASCII mode, third-party systems interface with Endura commands from Pelco’s CM9700 matrix to access and pull live and recorded Endura video onto matrix monitors through a network decoder and a third-party video down converter. V9700 mode makes use of familiar CM9760 keyboards to control Endura devices and monitors, and takes full advantage of megapixel and HD camera technology advancements.
®
utilizing the Pelco ASCII protocol. MDD mode processes
ASCII Protocol Management
When operating in ASCII mode, the UDI5000-MTRX allows third-party systems that integrated with the analog matrix through the Pelco ASCII protocol to work with Endura. The UDI5000-MTRX in ASCII mode presents 1,024 virtual alarms that can be configured in Endura for scripted responses to alarms or to convert ASCII switching commands to Endura software commands, allowing ASCII-driven switching of cameras onto Endura monitors.
V9700 Virtual Matrix Mode
In V9700 mode, the UDI5000-MTRX partially simulates a Pelco CM9780 analog matrix. A traditional PSM file is loaded onto the UDI5000-MTRX, which also processes Pelco P protocol commands from CM9760 keyboards and CM9760 alarm interface units connected through third-party serial to ethernet converters. While operating in V9700 mode, security administrators can continue leveraging most standard security operating procedures developed around analog matrix switches but in a virtual matrix environment. In addition, operators with previous experience using the CM9760-KBD keyboard can leverage their past experience and training when switching to a virtual matrix implementation. The V9700 mode supports Satellite Matrix Functionality (SMF) through the CM9700-NIU, thus allowing the Endura system to extend the useful life of existing analog matrix installations. When configured for V9700-SMF, CM9700 analog video can be converted and displayed on Endura digital monitors, and digital video from the Endura system can be converted and displayed on V9700 analog monitors. Matrix operators can have access to Endura
cameras on matrix monitors, and the ability to call up and switch matrix cameras and IP cameras onto Endura decoder monitors through the CM9760-KBD.
Matrix Digital Decoder Mode
In MDD mode, the UDI5000-MTRX bridges Endura products to the CM9700 Series matrix system (using 9.03.012 software or later versions). Adding the UDI5000-MTRX with a NET5402R-HD to a matrix system allows security professionals to leverage the digital advantages of Endura with their tried and true CM9700 Series matrix system. This allows users to continue viewing live analog video through the matrix while viewing digital live or recorded video from the Endura system through the NET5402R-HD high definition digital decoder connected as an input on the matrix through a third-party video down converter.
Convenient Scalability and Packaging
The UDI5000-MTRX supports Endura's unlimited scalability by providing a deterministic way to manage the processing load introduced with keyboard integration. Each UDI5000-MTRX can accommodate up to 10 connections, such as CM9760 Series keyboards and CM9760 alarm interface units. To provide unrestricted scalability, each UDI5000-MTRX is an independent server that can run multiple concurrent connections that are each running multiple routines. This capacity virtually eliminates undue load on other Endura servers and system components. UDI5000-MTRX servers can also act in a hot standby mode where the mission-critical nature of the installation demands redundancy.
The UDI5000-MTRX server is a half-width, 1 RU server. The compact size allows for two units to be rack mounted next to each other in just 1 RU of space using the optional rack mount kit. No additional software licensing is required.
Network Administration and Upgradeability
The UDI5000-MTRX supports Simple Network Management Protocol (SNMP) monitoring and traps along with Endura diagnostic monitoring. As such, health status information is available through the Endura WS5200 advanced system management software or an external SNMP monitoring application. The UDI5000-MTRX complies with Endura’s firmware upgrade scheme, allowing administrators to easily push out updated drivers and other utilities over the network as they become available from Pelco.
International Standards
Organization Registered Firm;
ISO 9001 Quality System
C4680 / REVISED 3-14-13
TECHNICAL SPECIFICATIONS
MODEL
Use the following table to create a model number to specify your UDI5000-MTRX. For example, the model number for a unit that includes a European power cord is UDI5000-MTRX-EU.
Model Country Code
-US = North America
-EU = Europe
UDI5000-MTRX
-UK = United Kingdom
-CN = China
-AU = Australia
-AR = Argentina
SUPPLIED ACCESSORIES
Power Cord 1 power cord (based on country designation)
Note: Units shipped to China do not include power cords.
OPTIONAL ACCESSORIES
RK-UDI5000 UDI5000 Series rack mount kit: 1 RU rack
mount assembly, hardware, and power supply support bracket
USER-SUPPLIED ACCESSORIES
In V9700 mode, third-party serial-to-Ethernet converters are required to connect the CM9760-KBD or CM9760-ALM products to the UDI5000-MTRX. In MDD mode, both serial-to-Ethernet and Video Down Converters are required. ASCII mode can use a serial-to-ethernet converter if needed.
SYSTEM
Operating System Embedded Linux
NETWORK
Interface 1 Gigabit Ethernet RJ-45
(10/100/1000Base-T)
FRONT PANEL
Power Button On/off Indicators
Power Blue if power Network Activity Green, amber, red Unit Status Green, amber, red
Auxiliary Interface 1 USB 2.0 port
Note: The temperature at the unit air intake can be significantly higher than room temperature. Temperature is affected by rack configuration, floor layout, air conditioning strategy, and other issues. To prevent performance failure and unit damage, make sure the temperature at the unit is continuously within the operating temperature range.
PHYSICAL
Construction Steel cabinet Finish
Front Panel Gray metallic with black end caps Chassis Black matte finish
Mounting
Desktop (feet) or rack 1 RU per unit, requires optional rack mount kit Unit Weight 3.0 kg (6.6 lb) Shipping Weight 3.6 kg (8.0 lb)
RECOMMENDED PC REQUIREMENTS
Web Browser Microsoft® Internet Explorer® 7 or later Media Player Adobe
®
Flash® Player 3.0
SYSTEM COMPATIBILITY REQUIREMENTS
WS5200 v2.3 or later VCD5202 v2.3.2.0017 or later NET5402R v2.3.2.0017 or later CM9700 Series matrix and components (in MDD mode) v9.03.032 or later CM9760-KBD (in V9700 mode) v8.45 or later CM9760-ALM
CERTIFICATIONS/RATINGS/PATENTS*
• CE, Class A
• FCC, Class A
• UL/cUL Listed
•C-Tick
•CCC *At the time of this publication, this certification is pending. Please
consult the factory, our Web site (www.pelco.com), or the most recent B.O.S.S.
®
update for the current status of certifications.
NOTE: VALUES IN PARENTHESES ARE INCHES;
ALL OTHERS ARE CENTIMETERS.
21.60 (8.80)
REAR PANEL
Serial Port RS-232 DB-9 connector Network Port 1 Gigabit Ethernet RJ-45 Other Ports (not used) 2 USB 2.0 ports, 1 parallel port, 1 S-Video
port, 1 VGA port, audio input/output
POWER
Power Consumption 31.2 W, 107 BTU/H Power Input 12 VDC ±10%
ENVIRONMENTAL
Operating Temperature 10° to 35°C (50° to 95°F) at unit air intake Storage Temperature –40° to 65°C (–40° to 149°F) Operating Humidity 20% to 80%, noncondensing Maximum Humidity Gradient 10% per hour Operating Altitude –15 to 3,048 m (–50 to 10,000 ft) Operating Vibration 0.25 G at 3 Hz to 200 Hz at a sweep rate of
9.5 octave/minute
Pelco by Schneider Electric
3500 Pelco Way, Clovis, California 93612-5699 United States
USA & Canada Tel (800) 289-9100 Fax (800) 289-9150 International Tel +1 (559) 292-1981 Fax +1 (559) 348-1120 www.pelco.com www.pelco.com/community
4.30 (1.70) 5.00 (1.80)
31.30 (12.32)
34.20 (13.46)
NOTICE: Judgment as to the suitability of the products for users’ purposes is solely the users’ responsibility. Users should refer to the Operation manuals for cautionary statements regarding user selected options and how they might affect video quality. Users shall determine the suitability of the products for their own intended application, picture rate and picture quality. In the event users intend to use the video for evidentiary purposes in a judicial proceeding or otherwise, users should consult with their attorney regarding any particular requirements for such use.
Pelco, the Pelco logo, and other trademar ks associated with Pelco products referred
to in this publication are trademarks of Pelco, Inc. or its affiliates. ONVIF and th e
ONVIF logo are trademarks of ONVIF Inc. All other prod uct names and
Product specifications and availability are subjec t to change without notice.
services are the property of their respective companie s.
©Copyright 2013, Pelco, Inc. All rights reserved.
Loading...