Pelco SS2000, SS22, SS2002 User Manual

®
SS20, SS22,
SS2000, SS2002
Series
Discreet
Surveillance
Enclosures
Installation/
Operation Manual
U
®
L
LISTED
Pelco • 300 W. Pontiac Way, Clovis • CA 93612-5699 USA • Pelco Online @ http://www.pelco.com In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 • DataFAX (800) 289-9108 International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120 • DataFAX (1-559) 292-0435

CONTENTS

Section Page
1.0 GENERAL .................................................................................................. 3
1.1 IMPORTANT SAFEGUARDS AND WARNINGS ...............................3
2.0 DESCRIPTION ..........................................................................................4
2.1 MODELS............................................................................................4
3.0 INSTALLATION .......................................................................................... 5
3.1 CONDUCTOR AND CABLE REQUIREMENTS ................................ 5
3.1.1Recommended Mounts..............................................................5
3.1.2Recommended Cables ..............................................................5
3.2 CONNECTOR ASSEMBL Y ................................................................9
3.3 MOUNTING ......................................................................................11
3.4 DOME INST ALLA TION .....................................................................12
4.0 EXPLODED ASSEMBL Y DIAGRAM.........................................................13
5.0 ADJUSTMENTS .......................................................................................15
6.0 MAINTENANCE ........................................................................................16
7.0 SPECIFICATIONS ....................................................................................17
8.0 WARRANTY AND RETURN INFORMATION ...........................................20

LIST OF ILLUSTRATIONS

Figure Page
1 SS20/SS22/SS2000/SS2002 Dimension Drawing.............................4
2 SS2000/SS2000-SL/SS2002-SL Wiring Diagram..............................6
3 SS2000-PP Wiring Diagram ..............................................................7
4 SS2000SL-PP Wiring Diagram .........................................................8
5 Connector Assembly.......................................................................... 9
6 Mating Cable Assembly Configuration (non-PP Versions) ................10
7 Mating Cable Assembly Configuration (PP Versions) .......................10
8 Mounting Configurations ...................................................................11
9 SS2000/SS2002 Exploded Assembly Diagram ................................14
10 Limit Stop Locations .........................................................................15
11 Tilt Limit Stop Modifications ..............................................................15

LIST OF TABLES

Table Page
A SS2000/SS2002 Exploded Assembly Diagram ................................13
REVISION HISTORY
Manual # Date Comments
C429M-A 10/94 Wire colors revised on figures 2-4, 6 and 7. (Pin 8 -
C429M-B 7/96 Revised to include new models SS22 and SS2002-SL.
8/96 Revised Section 5.0, Mechanical Parts List, regarding 7/97 Corrected wiring for pins 19 and 27 in Figure 7 per ECO 2/98 Revised Section 6.0, Maintenance. Changed manual to
Figure 2; Pins 8 & 23 - Figures 3 and 4; Pins 8, 11, 12, 13 - Figures 6 and 7.)
lower dome part numbers and quantities of velcro. 97-235. new style.
2 Pelco Manual C429M-B (2/98)

1.0 GENERAL

1.1 IMPORTANT SAFEGUARDS AND WARNINGS

CAUTION:
This device is designed to operate at 24 volts AC power. Input volt­ages must not exceed 28 volts or drop below 22 volts, or else damage the the motors will occur. Should you need technical assis­tance, please call (800) 289-
9100.
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
4. After replacement/repair of this unit’s electrical components, conduct a resis­tance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry.
5. The installation method and materials should be capable of supporting four times the weight of the enclosure, pan/tilt, camera and lens combination.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
CAUTION:
RISK OF
ELECTRIC SHOCK.
DO NOT OPEN.
TO REDUCE THE RISK OF ELECTRICAL SHOCK,
DO NOT REMOVE COVER. NO USER-
SERVICEABLE P ARTS INSIDE. REFER SERVICING
TO QUALIFIED SERVICE PERSONNEL.
CAUTION:
Please thoroughly familiarize yourself with the information
in this manual prior to installation and operation.
Pelco Manual C429M-B (2/98) 3

2.0 DESCRIPTION

Pelco’s SS20/SS22/SS2000/SS2002 Series domes are full-sphere, discreet sur­veillance enclosures designed to be suspended from ceilings and to compliment the interior design of businesses, hotels, and offices.
The black opaque (or chrome) lower dome effectively camouflages a CTTV security/ surveillance system without compromising the quality of the video picture.
Options for the SS2000/SS2002 include a standard pan/tilt, pan/tilt with continuous 360° pan rotation (SL), or preset pan/tilt available in either the standard or SL ver­sion pan/tilt. All pan/tilts are pre-wired for all system functions, dramatically reduc­ing installation time. The use of standard manufactured components increases the reliability and serviceability of the system.

2.1 MODELS

SS20 Full sphere discreet surveillance dome with fixed mount for
CCD type cameras. 14" black opaque lower dome with 1 f-stop light loss.
SS22 Same as SS20 except supplied with a 14" chrome opaque
lower dome with 2 f-stop light loss.
SS2000 Full sphere discreet surveillance dome with high speed integral
pan/tilt for CCD type cameras. 14" black opaque lower dome with 1 f-stop light loss.
SS2000-PP Full sphere discreet surveillance dome with high speed integral
pan/tilt with presets (/PP option) for CCD type cameras. 14" black opaque lower dome with 1 f-stop light loss.
SS2000-SL Same as SS2000 except supplied with 360° continuous pan
rotation
SS2002-SL Same as SS2000-SL except supplied with a 14" chrome
opaque lower dome with 2 f-stop light loss.
SS2000SL-PP Same as SS2000-PP except supplied with 360° continuous
pan rotation.
NOTE: VALUES IN PARENTHESIS ARE CENTIMETERS; ALL OTHERS ARE INCHES.
Figure 1. SS20/SS22/SS2000/SS2002 Dimension Drawing
4 Pelco Manual C429M-B (2/98)

3.0 INSTALLATION

Save the shipping carton and plastic packing in case the unit has to be returned for credit or repair.

3.1 CONDUCTOR AND CABLE REQUIREMENTS

NOTE:
The following are cable re­quirements. A relay box (RB24) is available to extend the operating dis­tance up to 13,000 feet (3,962 m) over 16 Awg wire.
A minimum of 11 conductors plus coax is required, which includes common re­quirements for motorized zoom lens and camera AC power.
Non-PP Models
11 Conductor 12 Conductor*
18 Awg 227 ft (82m) 494 ft (150 m) 16 Awg 432 ft (131 m) 785 ft (239 m) 14 Awg 690 ft (210 m) 1,253 ft (381 m)
PP Models
17 Conductor 18 Conductor*
18 Awg 227 ft (82m) 494 ft (150 m) 16 Awg 432 ft (131 m) 785 ft (239 m) 14 Awg 690 ft (210 m) 1,253 ft (381 m)
* Using 2 conductors for common Calculations are based on a 10% cable loss with both motors running.

3.1.1 Recommended Mounts

MRWA Wall mount adapter MRCA Ceiling mount adapter

3.1.2 Recommended Cables

C1906 Pretested 6-foot cable with video coax C1925 Pretested 25-foot cable with video coax
Pelco Manual C429M-B (2/98) 5
Figure 2. SS2000/SS2000-SL/SS2002-SL Wiring Diagram
6 Pelco Manual C429M-B (2/98)
Figure 3. SS2000-PP Wiring Diagram
Pelco Manual C429M-B (2/98) 7
Figure 4. SS2000SL-PP Wiring Diagram
8 Pelco Manual C429M-B (2/98)

3.2 CONNECTOR ASSEMBLY

NOTE:
Contacts cannot be removed from the connector without the use of an AMP extraction tool, part num­ber ZT305183 (for 9-, 14-, or 16-pin connector) or ZT91067-2 (for 28-pin connector), which is available from Pelco.
To install and test the SS2000/SS2002 Series dome you will need to assemble the connector parts provided. Fabricate the interconnecting cable as outlined below (see Figure 5):
1. Slide the cable clamp (part A , item 1) over the cable with the threaded end facing the connector (item 5).
2. If the cable has a diameter less than 1/2 inch (1.3 cm), slide the rubber boot (item 2) over the end of the cable and press inside the cable clamp to form a good seal.
3. Strip back the cable jacket approximately 1-1/4 inches (3.2 cm) and separate the individual conductors.
4. The contact pins supplied with the mating connector are the “crimp” type which may also be soldered if you so desire.
5. After crimping or soldering the contacts, push them into the proper holes in the connector until they snap in place.
6. Slide part A of the cable clamp toward the connector and screw the parts together. Attach part B (item 1) onto part A and connect both parts with the screws provided.
7. Connect the cable assembly to the unit and seat the connector by twisting the locking collar until it snaps into position.
8. For ease of installation, a mating cable assembly is supplied with the domes to extend the cable from the pan/tilt. Please refer to Figures 6 and 7 for wiring (pin locations and color codes).
Figure 5. Connector Assembly
Pelco Manual C429M-B (2/98) 9
14-POS RECEPTACLE CON206403-3
7 6 5 4
11 10 9 8
14 13 12
FRONT VIEW
14-PIN CONNECTOR
CABLE, 12 COND. @ 6' WIR201912
COAX @ 6' WIRRG59/U9259
CRIMP SOCKET CON66105-2
CABLE CLAMP CON206070-1
POSITION COLOR FUNCTION
1 BROWN COMMON/PAN AND TILT 2 CORE COAX VIDEO
3 2 1
3 RED LEFT 4 SHIELD COAX VIDEO 5 YELLOW DOWN 6 ORANGE UP 7 BLUE RIGHT 8 GREEN GROUND
9 WHITE AC HIGH, CAMERA 10 BLACK IRIS 11 TAN (OR BLK/WHT) FOCUS 12 PINK (OR RED/WHT) ZOOM 13 VIOLET COMMON, LENS 14 GRAY AC LOW, CAMERA
Figure 6. Mating Cable Assembly Configuration (non-PP Versions)
CONCP88-2
28-POS RECEPTACLE CON205839-3
3 1
8 4 14 9 20 15
25 21
28 26
FRONT VIEW
28-PIN CONNECTOR
CABLE, 12 COND. @ 6' WIR201912
CABLE, 9 COND. @ 6' WIR220709
COAX @ 6'
CRIMP SOCKET CON1-66504-0
CABLE CLAMP' CON206070-1
WIRRG174/U
CONCPM88-174
NO. COLOR FUNCTION NO. COLOR FUNCTION
1 BROWN COMMON/PAN AND TILT 15 —— —— 2 CORE COAX VIDEO 16 —— —— 3 RED LEFT 17 BLUE HIGH, PRESET 4 SHIELD COAX VIDEO 18 BROWN COMMON, PRESET 5 YELLOW DOWN 19 WHT/ORG/BLK SPARE 6 ORANGE UP 20 RED ZOOM, PRESET 7 BLUE RIGHT 21 YELLOW FOCUS, PRESET 8 GREEN GROUND 22 BLACK PAN, PRESET
9 WHITE AC HIGH, CAMERA 23 VIOLET TILT, PRESET 10 BLACK IRIS 24 WHITE PAN, PRESET (SL only) 11 TAN (OR BLK/WHT) FOCUS 25 —— —— 12 PINK (OR RED/WHT) ZOOM 26 —— —— 13 VIOLET COMMON, LENS 27 —— —— 14 GRAY AC LOW, CAMERA 28 —— ——
12 Conductor Cable
Coax
9 Conductor Cable
Figure 7. Mating Cable Assembly Configuration (PP Versions)
10 Pelco Manual C429M-B (2/98)

3.3 MOUNTING

The SS2000/SS2002 enclosure is designed to be suspended from a suitable length of 1-1/2" pipe threaded at both ends. This pipe can be interfaced to either a Pelco MRWA wall adapter, MRCA ceiling adapter, or coupled to a longer length of pipe. Refer to Figure 8 for mounting configurations.
STRUCTURAL CEILING MOUNTING
WALL MOUNTING
DROP CEILING MOUNTING
Figure 8. Mounting Configurations
Pelco Manual C429M-B (2/98) 11

3.4 DOME INSTALLATION

To install your dome system, perform the following steps (refer to Figure 9):
1. Select the appropriate pipe length and mounting method. If the MRCA or MRW A mount is used, tighten the pipe to approximately 30 ft lb, then tighten the 8-32 screw in the pipe nut to lock the pipe threads. Slide the upper dome onto the pipe and lock it out of the way with a suitable retainer.
2. Screw the mounting flange (item 4) onto the pipe and tighten securely (ap­proximately 20 ft lb). Tighten the 8-32 screw in the pipe nut to lock the pipe threads.
3. Align the three-hole pattern in the pan spindle with the holes in the lower bracket (item 5), and attach with 1/4"-20 x 5/8" hex head bolts and lock wash­ers provided. Tighten firmly .
4. Attach the upper (drive) bracket (item 3) to the bottom (spindle side) of the pan/tilt using four (4) 8-32 x 1/2" pan head screws and lock washers provided. Refer to Figure 9 for proper orientation.
5. Connect the installation cable to the pan/tilt and feed it through the center of the 1-1/2" pipe. Pull the cable and connector back up into the pipe so that it does not get caught on the rotating parts.
6. Assemble the lower bracket and pan/tilt to the mounting flange (item 4) using 1/4" x 5/8" hex head bolts and flat washers.
7. Install the camera/lens assembly onto the tilt table of the pan/tilt. Connect the proper cables.
NOTE:
The small hole in the upper dome (for safety chain attachment) should be positioned at the back (con­nector) end of the camera.
NOTE:
For SS20/SS22 mounting, re­fer to steps 1, 2, 6, 7, 8, and 10. For step 9, adjust the tilt and rotation, and tighten all hardware.
8. Remove the retainer from the upper dome and lower it until it seats itself on the drive bracket.
9. Turn the system “ON” and rotate the pan/tilt. Check for cable interference. Tilt the camera up and down and check for clearance of all moving parts.
10. After all tests have been done and the system is functioning properly, attach the safety chain to the upper dome with the fasteners provided. Install the lower dome and align the viewing window.
11. Check for sufficient clearance between the lens and the lower dome.
12 Pelco Manual C429M-B (2/98)

4.0 EXPLODED ASSEMBLY DIAGRAM

Table A. SS2000/SS2002 Exploded Assembly Diagram
Item Qty Description Part Number
1 1 Dome, upper SS200010000 2 1 Dome, lower, Black (Opaque) SS200010001*
Dome, lower, Chrome (Opaque) SS2012000* 3 1 Bracket, drive SS20004007COMP 4 1 Bracket, upper SS20001000COMP 5 1 Bracket, lower SS20004008COMP 6 48 V elcro, black, 5/8" wide x inch (not shown) TV10002 7 50 V elcro, black, 5/8" wide x inch (not shown) (SS22 & SS2002-SL) TV10003
56 Velcro, black, 5/8" wide x inch (not shown) (SS20 & SS2000 Series) TV10003 8 1 Chain, safety SB2511000 9 1 Pan/tilt assembly PT2500
1 Fixed mount assembly (Model SS20 only) SS20001001ASSY
10 1 Cable assembly , 14-pin x 6' (For SS2000 and SS2000-SL) SS1000ASSY
Cable assembly, 28-pin x 6' (SS2000-PP and SS2000SL-PP) SS1001ASSY 11 1 Pipe, mounting SS34002COMP 12 1 Snap body for safety chain (not shown) SB2511001
* Part number is for the dome only. To order a complete lower dome assembly, specify the part numbers SS20004300COMP (black)
and SS20200COMP (chrome). These part numbers include items 2, 7, 8, and 12.
Pelco Manual C429M-B (2/98) 13
Figure 9. SS2000/SS2002 Exploded Assembly Diagram
14 Pelco Manual C429M-B (2/98)

5.0 ADJUSTMENTS

To adjust the pan/tilt limits, perform the following steps. Refer to Figure 10 for limit stop locations.
CAUTION:
Do not attempt to adjust limit stops when the pan/tilt is in operation. Damage to the equipment can result. Do not operate equipment without limit stops. SL models are sup­plied without pan limit stops, therefore, no adjustments are necessary.
Factory pan limits are set to 0-355° and tilt limits are set to 0-90° (horizontal to vertical). Under normal conditions, the tilt limits should not have to be reset. To adjust limit stops, perform the following steps:
1. Pan to the right using the joystick control until the desired pan limit is reached. Adjust the pan limit stop until the actuator clicks. Lock the limit into position.
2. Pan to the desired left position, adjust the pan limit stop until the actuator clicks, and lock into position.
3. Pan to the left and right to verify exact positioning and tighten both stops se­curely.
4. The tilt limit is designed to allow for 0-90° travel (horizontal to vertical). The tilt can be adjusted to any point between horizontal and vertical, but must never exceed these boundaries.
5. T o alter the factory-set tilt limit, bend the actuator stops on the micro switches. Move the tilt table to the desired position and adjust the actuators until the switch clicks, lock into position (see Figure 11).
6. Tilt up and down to verify exact positioning.

Figure 10. Limit Stop Locations Figure 11. Tilt Limit Stop Modifications

Pelco Manual C429M-B (2/98) 15

6.0 MAINTENANCE

Clean the acrylic lower dome as necessary to maintain a clear picture. Be careful not to scratch the surfaces of the dome.
Exterior Surface - Clean the dome's exterior surface with a nonabrasive cleaning cloth and cleaning agent that is safe for acrylic plastic. Either liquid or spray cleaner/ wax suitable for fine furniture is acceptable.
Interior Surface (Except Chrome) - Clean the same as the exterior surface. Interior Surface (Chrome) - The inside surface of a chrome dome is easily scratched.
Use the following precautions to maintain the dome's surface. a. Always handle the dome from the outside of its circular flange. b. Never touch the coated inside surface. The acid in your fingerprints will even-
tually etch the coating if the fingerprints are not carefully removed according to the recommended cleaning procedure in item “e.”
c. If dust or other contaminants accumulate on the dome's interior, remove the
debris with compressed air. Compressed air cans are available from photo­graphic equipment or electronic supply dealers.
d. If heavy residue accumulates and cannot be removed with air pressure, rinse
with water and immediately dry with air pressure so that water spots will not remain. A void wiping the coated surface with direct hand pressure - it will eas­ily abrade unless extreme care is taken. Once scratched, the dome cannot be recoated.
e. If internal wiping is necessary, avoid hand rubbing. Instead, make a wick as
follows: Use a very soft paper towel. Roll a section into a tightly wound tube. Tear the
tube in half, and wet the fuzzy end of the wick with a solution of isopropyl alcohol diluted with water. Hold the dome with its opening facing downward and wipe the interior of the dome with the wet end of the wick. Use a circular motion, starting from the outside and spiraling into the center. Use a new wick for each two passes over the dome.
16 Pelco Manual C429M-B (2/98)

7.0 SPECIFICATIONS

ELECTRICAL
Input Voltage: 24 VAC required for pan/tilt Running Current
Pan: 0.31 amp (7.44 vA) Tilt: 0.38 amp (9.12 vA)
Connectors
Pan/Tilt: Amp CPC type (mate supplied) Lens: Hirschmann MAB6100
Video: BNC Camera Power: Spade lugs Motors: Two-phase induction type, instantaneous reversing Limit Switches
Pan: 5 amp, (external adjustment)
Tilt: 5 amp, (external adjustment) Conductor
Requirements as listed, plus coax cable:
Non-PP models: Pan/tilt (5 plus ground), Lens (4), Camera AC (2)
PP models: Pan/tilt (9 plus ground), Lens (6), Camera AC (2)
MECHANICAL
Pan: 0-355° movement in horizontal plane (Models SS2000, SS2000-PP)
Pan Speed: 24°/sec ± 1° (no load condition) Tilt: -90° from horizontal plane Tilt Speed: 12°/sec ± .5° (no load condition) Maximum Load: 10 lb (4.6 kg) Gearing: Chain and direct drive Bearings
Pan: Heavy duty ball bearing and Oilite bronze bushing
Tilt: Oilite bronze bushing Braking: Friction
360° continuous rotation (Models SS2000-SL, SS2000SL-PP)
Pelco Manual C429M-B (2/98) 17
GENERAL
Maximum Camera/ Lens Length: 12.5 inches (31.75 cm)
Ambient Temperature Range: 35°F to 120°F (1.6°C to 48.8°C)
Construction
Upper dome: Black, high-impact plastic, ABS
Lower dome: Acrylic hemisphere with distortion-free viewing window with
Dimensions: See Figure 1 Weight
Model SS20/
SS22: 7 lb
All other models: 14 lb 13 oz Shipping Weight
Model SS20/
SS22: 8 lb
All other models: 17 lb
light attenuation factor of 1 f-stop; model SS2002-SL has 2 f­stop light attenuation factor. Rotates with pan/tilt and camera/ lens
(Design and product specifications subject to change without notice.)
18 Pelco Manual C429M-B (2/98)
NOTES
Pelco Manual C429M-B (2/98) 19

8.0 WARRANTY AND RETURN INFORMATION

WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Excep­tions to this warranty are as noted below:
Three years on Genex™ Series multiplexers.
Two years on all standard motorized and fixed focal length lenses.
Two years on Legacy®, Intercept®, PV1000 Series, CM6700/CM8500/CM9500/
CM9750/CM9760 Matrix, Spectra™, DF5 Series and DF8 Fixed Dome products.
Two years on WW5700 series window wiper (excluding wiper blades).
Two years on cameras.
Six months on all pan and tilts, scanners or preset lenses used in continuous
motion applications (that is, preset scan, tour and auto scan modes).
Pelco will warranty all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss result­ing from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.
®Pelco and the Pelco logo are registered
trademarks of Pelco.
©Copyright 1998, Pelco. All rights
reserved.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information:
1. Model and serial number
2. Date of shipment, P .O. number , Sales Order number , or Pelco invoice number
3. Details of the defect or problem If there is a dispute regarding the warranty of a product which does not fall under
the warranty conditions stated above, please include a written explanation with the product when returned.
Ship freight prepaid to: Pelco
300 West Pontiac Way Clovis, CA 93612-5699
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair). Goods returned for repair or credit should be clearly identified with the assigned CA/RA number and freight should be prepaid. All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Ship freight prepaid to: Pelco
300 West Pontiac Way Clovis, CA 93612-5699
20 Pelco Manual C429M-B (2/98)
Loading...