6. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
7. Only use attachments/accessories specified by the manufacturer.
8. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such
as vases shall be placed on the apparatus.
9. Installation should be done only by qualified personnel and conform to all local codes.
10. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is
designed for indoor use only and it must not be installed where exposed to rain and moisture.
11. Use only installation methods and materials capable of supporting four times the maximum
specified load.
12. Use stainless steel hardware to fasten the mount to outdoor surfaces.
13. Only use replacement parts recommended by Pelco.
14. After replacement/repair of this unit’s electrical components, conduct a resistance measurement
between the line and exposed parts to verify the exposed parts have not been connected to the line
circuitry.
WARNING: This product is sensitive to Electrostatic Discharge (ESD). To avoid ESD damage to this
product, use ESD safe practices during installation. Before touching, adjusting or handling this product,
correctly attach an ESD wrist strap to your wrist and appropriately discharge your body and tools. For more
information about ESD control and safe handling practices of electronics, please refer to ANSI/ESD S20.201999 or contact the Electrostatic Discharge Association (www.esda.org).
The materials used in the manufacture of this document and its components are compliant to the requirements
of Directive 2002/95/EC.
This equipment contains electrical or electronic components that must be recycled properly to comply with
Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic
equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.
4C3446M (7/08)
Regulatory Notices
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However there is no guarantee that the interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and the receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
•Consult the dealer or an experienced radio/TV technician for help.
You may also find helpful the following booklet, prepared by the FCC: “How to Identify and Resolve
Radio-TV Interference Problems.” This booklet is available from the U.S. Government Printing Office,
Washington D.C. 20402.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment
can void your authority to operate this equipment under Federal Communications Commission’s rules.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
C3446M (7/08)5
Description
The Spectra® Mini IP dome system is an indoor mini dome system with a built-in 100Base-TX network
interface for live streaming to a standard Web browser (Microsoft
Spectra Mini IP dome features open architecture connectivity for third-party software recording solutions
and is also Endura Enabled
The Spectra Mini IP also includes built-in Power over Ethernet (PoE), which supplies power to the dome
system through the network. If PoE is not available, the unit is prewired for 24 VAC.
Before installing your new system, thoroughly familiarize yourself with the information in this manual.
™
to record, manage, configure, and view multiple live streams.
®
Internet Explorer® or Firefox®). The
SYSTEM MODELS
Model NumberDescription
SD4N-B0Spectra Mini IP, indoor, black, smoked dome, NTSC
SD4N-B0-XSpectra Mini IP, indoor, black, smoked dome, PAL
SD4N-B1Spectra Mini IP, indoor, black, clear dome, NTSC
SD4N-B1-XSpectra Mini IP, indoor, black, clear dome, PAL
SD4N-W0Spectra Mini IP, indoor, white, smoked dome, NTSC
SD4N-W0-XSpectra Mini IP, indoor, white, smoked dome, PAL
SD4N-W1Spectra Mini IP, indoor, white, clear dome, NTSC
SD4N-W1-XSpectra Mini IP, indoor, white, clear dome, PAL
6C3446M (7/08)
PARTS LIST
The following parts are supplied with the Spectra Mini IP dome system:
Qty Description
1Dome drive
1Dome bubble with trim ring
1
Installation manual (C3446M)
1Operation/Configuration manual (C3447M)
1Spring paddle flex assembly
1Hardware kit
2 #10 x 1.50-inch self-tapping screws for suspended ceiling installation
2 #8-32 x 3.50-inch machine screws for suspended ceiling installations
2 #8 x 3.50-inch self-tapping screws for surface mount installation
The following parts, in addition to the normal installation tools, are needed but not supplied:
Qty Description
1Small flashlight for viewing connectors
1Long-handled flat-blade screwdriver for wiring terminal
26-32 toggle bolts for surface mount installation (optional)
28-32 studs and nuts for surface mount installation to concrete
C3446M (7/08)7
BASIC SYSTEM CONFIGURATIONS
The following illustrations demonstrate the possible configurations of Spectra Mini IP with a variety of
network options.
IMPORTANT NOTE. PLEASE READ. The network implementations in this document are shown as
general representations only and are not intended to show detailed network topologies. Your actual
network will differ, requiring changes or perhaps additional network equipment to accommodate the
systems as illustrated. Please contact your local Pelco Representative to discuss your specific
requirements.
Refer to Network Settings in the Spectra Mini IP Operation/Configuration manual (C3447M) for more
information about DHCP and static IP networks. Refer to Table A when viewing Figure 1 on page 9,
Figure 2 on page 9, Figure 3 on page 10, and Figure 4 on page 11.
Table A. Legend for System Configuration Example Diagrams
Spectra Mini IP dome system
Web browser
TCP/IP/Internet
®
Endura
network
DVR
Network Switch
Cable Modem Router/Switch
8C3446M (7/08)
DHCP NETWORK
In this configuration, the DHCP network is accessed through the Web browser.
NOTE: For a secure network, Pelco recommends placing the dome behind a firewall.
Refer to Table A on page 8.
Figure 1. DHCP Network Example
ENDURA NETWORK
Refer to Table A on page 8.
Figure 2. Endura Network Example
C3446M (7/08)9