Thank you for purchasing Pelco’s premier integrated dome system, Spectra® IV/Spectra IV SE. Your new system features a high
resolution camera/optics package with programmable dome drive software.
This manual is designed primarily to be a reference tool for the installation and operation of your system. Inside you will find
information about features and commands, as well as a detailed menu tree and a quick start guide. Installation on page 7 provides
information required to set up and install the dome drive. Please thoroughly familiarize yourself with the information in this manual
before installing and using your system.
6C3412M-D (12/08)
Page 6
Installation
This manual contains installation instructions only for the Spectra IV/Spectra IV SE dome drive. For complete installation
instructions for a Spectra IV/Spectra IV SE dome system, refer to the installation manual shipped with the back box.
SWITCH SETTINGS
Before installing the dome drive, configure the receiver address, termination, and baud setting. The DIP switches used to
configure these settings are located on the base of the dome drive.
Figure 1 shows the default settings for the DIP switches. Switch SW1-1 (SW1, switch 1) is set to the ON position; all other
switches are set to the OFF position.
Refer to the following sections to set the address, termination, and baud settings for the dome drive.
ON
SW2
12345678910
ON
SW1
12345678
Figure 1. Default Switch Settings
SW1: RECEIVER ADDRESS
Set the SW1 switches for the address of the dome drive. The following information is required to set the dome drive
address:
P-type control: The default address is 2. Refer to Table A on page 10 for address settings that use P-type control. The
maximum number of receivers is 32.
D-type control: The default address is 1. Refer to Table B on page 11 for address settings that use D-type control. The
maximum number of receivers is 254.
SW2 SWITCH 1: AD-32 PRESET SYSTEM
SW2-1 should be set to the ON position if an AD-32 controller and Pelco’s TXB-AD translator board are used to control the
dome system.
SW2 SWITCH 2: CM9502 SETTING
If a CM9502 matrix system is used with the dome drive, set SW2-2 to the ON position.
C3412M-D (12/08)7
Page 7
SW2 SWITCH 3: CONTROL SYSTEM COMPATIBILITY
Coaxial Control Systems
Although Spectra IV/Spectra IV SE dome systems can operate with coaxial control systems from many manufacturers, the
system is designed for optimal performance with Pelco Coaxitron® control products within the length specified for coaxial
cable.
To compensate for coaxial control systems from other manufacturers, Pelco has provided DIP switch SW2-3. Setting
SW2-3 to the ON position may improve dome control with these control systems.
If you are using a Pelco Coaxitron controller, leave SW2-3 in the default OFF position.
Notes:
•This coaxial control system compatibility feature is only available for dome drive revisions A4 and later (revisions A0
and later for Spectra IV Horizon dome drives). The revision number can be found on the barcode label on the top of
the dome drive. Software version 1.090 and later indicates this mode is available by placing an asterisk next to the
switch number in the Dip Switch Information menu.
•In some configurations, Pelco CM9502 Series matrix systems use nonstandard Coaxitron commands for functions like
pattern playback. If you experience problems with these functions, set SW2-3 to the ON position.
Pelco P Protocol Control Systems
To compensate for Pelco P protocol control systems from other manufacturers, set SW2-3 to the ON position. This may
improve dome control with some of these control systems.
SW2 SWITCHES 4–5: SERIAL PORT SETTINGS
RS-422 Setting (Default)
SW2-4 and SW2-5 should both be set to the OFF position for RS-422 setting.
For control, only two wires should be connected to the RX- and RX+ connectors on the circuit board inside the back box. For
bidirectional control, four wires should be connected to the RX-, RX+, TX-, and TX+ connectors on the circuit board inside
the back box.
RS-485, 4-Wire Setting
SW2-4 should be set to OFF and SW2-5 should be set to ON if a 4-wire serial port connection is used with RS-485.
Note: This setting is most commonly used with Pelco Endura® systems.
RS-485, 2-Wire Setting
SW2-4 and SW2-5 should both be set to the ON position if a 2-wire serial port connection is used with RS-485.
This setting is used to allow the Spectra dome system to transmit and receive commands on the same pair of wires. Only
two wires should be connected to the RX- and RX+ connectors on the circuit board inside the back box.
8C3412M-D (12/08)
Page 8
SW2 SWITCHES 6–8: BAUD SETTINGS
Pelco’s D-type controllers are set for 2400 baud. The default setting for the dome drive is 2400 baud. If you are using a
Pelco D-type controller, do not reset SW2 switches 1–3 or SW2 switches 6–8.
P-type controllers can operate at 2400, 4800, and 9600 baud. Set the SW2 switches (6, 7, and 8), located on the base of
the dome drive, to the same baud as the P-type controller.
Switch NumberSW2-6SW2-7SW2-8
2400 Baud (default for D-type control)OffOffOff
4800 Baud (default for P-type control)OnOffOff
9600 BaudOffOnOff
SW2 Switch 9: Coaxial/UTP Cable
SW2-9 should be set to the OFF position (default) if you are using coaxial cable. If you are using unsheilded twisted pair
(UTP) cable, set SW2-9 to the ON position.
SW2 Switch 10: Termination Setting
When connecting more than one Spectra IV/Spectra IV SE dome system to a single controller, terminate the unit farthest
from the controller. Termination is only required for the last dome in the series.
The dome drive is shipped from the factory in the unterminated (OFF) position. To terminate the dome drive, set SW2-10 to
the ON position.
Note: Dome termination is not required for Coaxitron
®
control.
DOME DRIVE INSTALLATION
Install the dome drive. Align the blue and red tabs with the blue and red arrows on the hinged door inside the back box.
Push the tabs in. Insert one side and then the other side. Continue pushing on the ends of the tabs until both sides click
into place (refer to Figure 2). To use your dome system, refer to Getting Started on page 19.
Figure 2. Dome Drive Installation
Note: When removing a dome drive that has been in use, caution should be taken to avoid direct contact with the top
plate of the unit. This section of the unit will be warm to the touch when first removed from an operating unit.
C3412M-D (12/08)9
Page 9
Table A. Switch Settings for SW1 P-Type Control
SPECTRA
ADDRESS
1OFFOFFOFFOFFOFFOFFOFFOFF
2ONOFFOFFOFFOFFOFFOFFOFF
3OFFONOFFOFFOFFOFFOFFOFF
4ONONOFFOFFOFFOFFOFFOFF
5OFFOFFONOFFOFFOFFOFFOFF
6ONOFFONOFFOFFOFFOFFOFF
7OFFONONOFFOFFOFFOFFOFF
8ONONONOFFOFFOFFOFFOFF
9OFFOFFOFFONO FFOFFOFFOFF
10ONOFFOFFONOFFOFFOFFOFF
11OFFONOFFONOFFOFFOFFOFF
12ONONOFFONOFFOFFOFFOFF
13OFFOFFONONOFFOFFOFFOFF
14ONOFFONONOFFOFFOFFOFF
15OFFONONONOFFOFFOFFOFF
16ONONONONOFFOFFOFFOFF
17OFFOFFOFFOFFONOFFOFFOFF
18ONOFFOFFOFFONOFFOFFOFF
19OFFONOFFOFFONOFFOFFOFF
20ONONOFFOFFONOFFOFFOFF
21OFFOFFONOFFONOFFOFFOFF
22ONOFFONOFFONOFFOFFOFF
23OFFONONOFFONOFFOFFOFF
24ONONONOFFONOFFOFFOFF
25OFFOFFOFFONONOFFOFFOFF
26ONOFFOFFONONOFFOFFOFF
27OFFONOFFONONOFFOFFOFF
28ONONOFFONONOFFOFFOFF
29OFFOFFONONONOFFOFFOFF
30ONOFFONONONOFFOFFOFF
31 OFFONONONONOFFOFFOFF
32ONONONONONOFFOFFOFF
SW1-1SW1-2SW1-3SW1-4SW1-5SW1-6SW1-7SW1-8
SWITCH SETTING
10C3412M-D (12/08)
Page 10
Table B. Switch Settings for SW1 D-Type Control
SPECTRA
ADDRESS
1O NOFFOFFOFFOFFOFFOFFOFF
2OFFONOFFOFFOFFOFFOFFOFF
3O NONOFFOFFOFFOFFOFFOFF
4OFFOFFONOFFOFFOFFOFFOFF
5ONOFFONOFFOFFOFFOFFOFF
6OFFONONOF FOFFOFFOF FOFF
7O NONONOFFOFFOFFOFFOFF
8OFFOFFOFFONOFFOFFOFFOFF
9 ONOFFOFFONOFFOFFOFFOFF
10OFFONOFFONOFFOFFOFFOFF
11ONONOFFONOFFOFFOFFOFF
12OFFOFFONONOFFOFFOFFOFF
13ONOFFONONOFFOFFOFFOFF
14OFFONONONOFFOFFOFFOFF
15ONONONONOFFOFFOFFOFF
16OFFOFFOFFOFFONOFFOFFOFF
17ONOFFOFFOFFONOFFOFFOFF
18OFFONOFFOF FONOFFOFFOFF
19ONONOFFOFFONOFFOFFOFF
20OFFOFFONOFFONOFFOFFOFF
21ONOFFONOFFONOFFOFFOFF
22OFFONONOF FONOFFOF FOFF
23ONONONOFFONOFFOFFOFF
24OFFOFFOFFONONOFFOFFOFF
25ONOFFOFFONONOFFOFFOFF
26OFFONOFFONONOFFOFFOFF
27ONONOFFONONOFFOFFOFF
28OFFOFFONONONOFFOFFOFF
29ONOFFONONONOFFOFFOFF
30OFFONONONONOFFOFFOFF
31ONONONONONOFFOFFOFF
32OFFOFFOFFOFFOFFONOFFOFF
33ONOFFOFFOFFOFFONOFFOFF
34OFFONOFFOF FOFFONOFFOFF
35ONONOFFOFFOFFONOFFOFF
SW1-1SW1-2SW1-3SW1-4SW1-5SW1-6SW1-7SW1-8
SWITCH SETTING
C3412M-D (12/08)11
Page 11
Table B. Switch Settings for SW1 D-Type Control (Continued)
SPECTRA
ADDRESS
36OFFOFFONOFFOFFONOFFOFF
37ONOFFONOFFOFFONOFFOFF
38OFFONONOF FOFFONOFFOFF
39ONONONOFFOFFONOFFOFF
40OFFOFFOFFONOFFONOFFOFF
41ONOFFOFFONOFFONOFFOFF
42OFFONOFFONOFFONOFFOFF
43ONONOFFONOFFONOFFOFF
44OFFOFFONONOFFONOFFOFF
45ONOFFONONOFFONOFFOFF
46OFFONONONOFFONOFFOFF
47ONONONONOFFONOFFOFF
48OFFOFFOFFOFFONONOFFOFF
49ONOFFOFFOFFONONOFFOFF
50OFFONOFFOF FONONOF FOFF
51ONONOFFOFFONONOFFOFF
52OFFOFFONOFFONONOFFOFF
53ONOFFONOFFONONOFFOFF
54OFFONONOF FONONOF FOFF
55ONONONOFFONONOFFOFF
56OFFOFFOFFONONONOFFOFF
57ONOFFOFFONONONOFFOFF
58OFFONOFFONONONOFFOFF
59ONONOFFONONONOFFOFF
60OFFOFFONONONONOFFOFF
61ONOFFONONONONOFFOFF
62OFFONONONONONOFFOFF
63ONONONONONONOFFOFF
64OFFOFFOFFOFFOFFOFFONOFF
65ONOFFOFFOFFOFFOFFONOFF
66OFFONOFFOF FOFFOFFONOFF
67ONONOFFOFFOFFOFFONOFF
68OFFOFFONOFFOFFOFFONOFF
69ONOFFONOFFOFFOFFONOFF
70OFFONONOF FOFFOFFONOFF
SW1-1SW1-2SW1-3SW1-4SW1-5SW1-6SW1-7SW1-8
SWITCH SETTING
12C3412M-D (12/08)
Page 12
Table B. Switch Settings for SW1 D-Type Control (Continued)
SPECTRA
ADDRESS
71ONONONOFFOFFOFFONOFF
72OFFOFFOFFONOFFOFFONOFF
73ONOFFOFFONOFFOFFONOFF
74OFFONOFFONOFFOFFONOFF
75ONONOFFONOFFOFFONOFF
76OFFOFFONONOFFOFFONOFF
77ONOFFONONOFFOFFONOFF
78OFFONONONOFFOFFONOFF
79ONONONONOFFOFFONOFF
80OFFOFFOFFOFFONOFFONOFF
81ONOFFOFFOFFONOFFONOFF
82OFFONOFFOF FONOFFONOFF
83ONONOFFOFFONOFFONOFF
84OFFOFFONOFFONOFFONOFF
85ONOFFONOFFONOFFONOFF
86OFFONONOF FONOFFONOFF
87ONONONOFFONOFFONOFF
88OFFOFFOFFONONOFFONOFF
89ONOFFOFFONONOFFONOFF
90OFFONOFFONONOFFONOFF
91ONONOFFONONOFFONOFF
92OFFOFFONONONOFFONOFF
93ONOFFONONONOFFONOFF
94OFFONONONONOFFONOFF
95ONONONONONOFFONOFF
96OFFOFFOFFOFFOFFONONOFF
97ONOFFOFFOFFOFFONONOFF
98OFFONOFFOF FOFFONONOFF
99ONONOFFOFFOFFONONOFF
100OFFOFFONOFFOFFONONOFF
101ONOFFONOFFOFFONONOFF
102OFFONONOFFOFFONONOFF
103ONONONOFFOFFONONOFF
104OFFOFFOFFONOFFONONOFF
105ONOFFOFFONOFFONONOFF
SW1-1SW1-2SW1-3SW1-4SW1-5SW1-6SW1-7SW1-8
SWITCH SETTING
C3412M-D (12/08)13
Page 13
Table B. Switch Settings for SW1 D-Type Control (Continued)
SPECTRA
ADDRESS
106OFFONOFFONOFFONONOFF
107ONONOFFONOFFONONOFF
108OFFOFFONONOFFONONOFF
109ONOFFONONOFFONONOFF
110OFFONONONOFFONONOFF
111 ONONONONOFFONONOFF
112OFFOFFOFFOFFONONONOFF
113ONOFFOFFOFFONONONOFF
114OFFONOFFOFFONONONOFF
115 ONONOFFOFFONONONOFF
116OFFOFFONOFFONONONOFF
117ONOFFONOFFONONONOFF
118OFFONONOFFONONONOFF
119ONONONOFFONONONOFF
120OFFOFFOFFONONONONOFF
121 ONOFFOFFONONONONOFF
122OFFONOFFONONONONOFF
123ONONOFFONONONONOFF
124OFFOFFONONONONONOFF
125ONOFFONONONONONOFF
126OFFONONONONONONOFF
127 ONONONONONONONOFF
128OFFOFFOFFOFFOFFOFFOFFON
129ONOFFOFFOFFOFFOFFOFFON
130OFFONOFFOFFOFFOFFOFFON
131ONONOFFOFFOFFOFFOFFON
132OFFOFFONOFFOFFOFFOFFON
133ONOFFONOFFOFFOFFOFFON
134OFFONONOFFOFFOFFOFFON
135ONONONOFFOFFOFFOFFON
136OFFOFFOFFONOFFOFFOFFON
137ONOFFOFFONOFFOFFOFFON
138OFFONOFFONOFFOFFOFFON
139ONONOFFONOFFOFFOFFON
140OFFOFFONONOFFOFFOFFON
SW1-1SW1-2SW1-3SW1-4SW1-5SW1-6SW1-7SW1-8
SWITCH SETTING
14C3412M-D (12/08)
Page 14
Table B. Switch Settings for SW1 D-Type Control (Continued)
SPECTRA
ADDRESS
141ONOFFONONOFFOFFOFFON
142OFFONONONOFFOFFOFFON
143 ONONONONOFFOFFOFFON
144OFFOFFOFFOFFONOFFOFFON
145ONOFFOFFOFFONOFFOFFON
146OFFONOFFOFFONOFFOFFON
147 ONONOFFOFFONOFFOFFON
148OFFOFFONOFFONOFFOFFON
149ONOFFONOFFONOFFOFFON
150OFFONONOFFONOFFOFFON
151ONONONOFFONOFFOFFON
152OFFOFFOFFONONOFFOFFON
153ONOFFOFFONONOFFOFFON
154OFFONOFFONONOFFOFFON
155ONONOFFONONOFFOFFON
156OFFOFFONONONOFFOFFON
157ONOFFONONONOFFOFFON
158OFFONONONONOFFOFFON
159 ONONONONONOFFOFFON
160OFFOFFOFFOFFOFFONOFFON
161ONOFFOFFOFFOFFONOFFON
162OFFONOFFOFFOFFONOFFON
163ONONOFFOFFOFFONOFFON
164OFFOFFONOFFOFFONOFFON
165ONOFFONOFFOFFONOFFON
166OFFONONOFFOFFONOFFON
167ONONONOFFOFFONOFFON
168OFFOFFOFFONOFFONOFFON
169ONOFFOFFONOFFONOFFON
170OFFONOFFONOFFONOFFON
171ONONOFFONOFFONOFFON
172OFFOFFONONOFFONOFFON
173ONOFFONONOFFONOFFON
174OFFONONONOFFONOFFON
175 ONONONONOFFONOFFON
SW1-1SW1-2SW1-3SW1-4SW1-5SW1-6SW1-7SW1-8
SWITCH SETTING
C3412M-D (12/08)15
Page 15
Table B. Switch Settings for SW1 D-Type Control (Continued)
SPECTRA
ADDRESS
176OFFOFFOFFOFFONONOFFON
177ONOFFOFFOFFONONOFFON
178OFFONOFFOFFONONOFFON
179 ONONOFFOFFONONOFFON
180OFFOFFONOFFONONOFFON
181ONOFFONOFFONONOFFON
182OFFONONOFFONONOFFON
183ONONONOFFONONOFFON
184OFFOFFOFFONONONOFFON
185ONOFFOFFONONONOFFON
186OFFONOFFONONONOFFON
187ONONOFFONONONOFFON
188OFFOFFONONONONOFFON
189ONOFFONONONONOFFON
190OFFONONONONONOFFON
191 ONONONONONONOFFON
192OFFOFFOFFOFFOFFOFFONON
193ONOFFOFFOFFOFFOFFONON
194OFFONOFFOFFOFFOFFONON
195ONONOFFOFFOFFOFFONON
196OFFOFFONOFFOFFOFFONON
197ONOFFONOFFOFFOFFONON
198OFFONONOFFOFFOFFONON
199ONONONOFFOFFOFFONON
200OFFOFFOFFONOFFOFFONON
201 ONOFFOFFONOFFOFFON ON
202OFFONOFFONOFFOFFONON
203ONONOFFONOFFOFFONON
204OFFOFFONONOFFOFFONON
205ONOFFONONOFFOFFONON
206OFFONONONOFFOFFONON
207 ONONONONOFFOFFONON
208OFFOFFOFFOFFONOFFONON
209ONOFFOFFOFFONOFFONON
210OFFONOFFOFFONOFFONON
SW1-1SW1-2SW1-3SW1-4SW1-5SW1-6SW1-7SW1-8
SWITCH SETTING
16C3412M-D (12/08)
Page 16
Table B. Switch Settings for SW1 D-Type Control (Continued)
SPECTRA
ADDRESS
211ONONOFFOFFONOFFONON
212OFFOFFONOFFONOFFONON
213ONOFFONOFFONOFFONON
214OFFONONOFFONOFFONON
215ONONONOFFONOFFONON
216OFFOFFOFFONONOFFONON
217ONOFFOFFONONOFFONON
218OFFONOFFONONOFFONON
219ONONOFFONONOFFONON
220OFFOFFONONONOFFONON
221ONOFFONONONOFFONON
222OFFONONONONOFFONON
223 ONONONONONOFFONON
224OFFOFFOFFOFFOFFONONON
225ONOFFOFFOFFOFFONONON
226OFFONOFFOFFOFFONONON
227ONONOFFOFFOFFONONON
228OFFOFFONOFFOFFONONON
229ONOFFONOFFOFFONONON
230OFFONONOFFOFFONONON
231ONONONOFFOFFONONON
232OFFOFFOFFONOFFONONON
233ONOFFOFFONOFFONONON
234OFFONOFFONOFFONONON
235ONONOFFONOFFONONON
236OFFOFFONONOFFONONON
237ONOFFONONOFFONONON
238OFFONONONOFFONONON
239ONONONONOFFONONON
240OFFOFFOFFOFFONONONON
241ONOFFOFFOFFONONONON
242OFFONOFFOFFONONONON
243 ONONOFFOFFONONONON
244OFFOFFONOFFONONONON
245ONOFFONOFFONONONON
SW1-1SW1-2SW1-3SW1-4SW1-5SW1-6SW1-7SW1-8
SWITCH SETTING
C3412M-D (12/08)17
Page 17
Table B. Switch Settings for SW1 D-Type Control (Continued)
SPECTRA
ADDRESS
246OFFONONOFFONONONON
247ONONONOFFONONONON
248OFFOFFOFFONONONONON
249 ONOFFOFFONONONONON
250OFFONOFFONONONONON
251ONONOFFONONONONON
252OFFOFFONONONONONON
253ONOFFONONONONONON
254OFFONONONONONONON
SW1-1SW1-2SW1-3SW1-4SW1-5SW1-6SW1-7SW1-8
SWITCH SETTING
18C3412M-D (12/08)
Page 18
Getting Started
Once installed, apply power to the Spectra IV/Spectra IV SE dome system. The system will start a configuration sequence.
When configuration is done, the following information is displayed:
Pelco Spectra IV/Spectra IV SE
Version X.XX
D Address: 1
P Address: 2
Comm 2400, N, 8, 1
CONFIGURE DONE
This information will remain on the monitor until dome operation begins.
Note: When installing a Spectra IV dome drive in a Spectra III
installation is complete, the dome drive will continue with a normal configuration sequence.
™
back box for the first time, a message appears. When the
C3412M-D (12/08)19
Page 19
How to Operate Your Dome System
OperationHow to Control
Pan and TiltMove the joystick or press the direction keys left/right and up/down.
Zoom FarTo zoom far:
1. Press the Zoom Tele button or turn the joystick clockwise until zoom stops at the optical zoom
limit.
2. Release the button or joystick for one second.
3. To continue zooming (digitally), press the button or turn the joystick clockwise again until you
have the picture you want or reach the digital zoom1 limit.
Zoom WidePress the Zoom Wide button or turn the joystick counterclockwise.
Scanning
Stop ScanPreset 96
Random ScanPreset 97
Frame ScanPreset 98
Auto ScanPreset 99
PresetsRefer to the documentation supplied with the control system.
Patterns
2
ZonesRefer to Zones on page 64 and to the documentation supplied with the control system.
Refer to the documentation supplied with the control system.
AlarmsRefer to Alarms on page 68.
Auto FlipTurn on or off in the programming menu. Refer to Auto Flip on page 50.
1
Digital zoom magnifies the image electronically and the picture may appear pixilated. The larger the digital zoom limit the greater the
reduction in resolution.
2
The dome cannot do electronic zoom in a pattern. Optical zoom will operate in a pattern.
20C3412M-D (12/08)
Page 20
QUICK PROGRAMMING GUIDE
Access main menu (preset 95). Refer to Accessing Main Menu (Preset 95) on page 21.
Use the joystick to position the cursor beside menu selection.
Note: If your controller does not have a joystick, use the up or down key.
Press Iris Open, the submenu/cursor moves to the right.
Move the joystick up or down to view selections.
Press Iris Open to make a selection.
Press Iris Close to cancel a selection.
ACCESSING MAIN MENU (PRESET 95)
You can call up the main menu on your monitor by programming (setting or creating) preset 95 (preset 28 in AD32-preset
mode).
Programming preset 95 for Pelco’s controllers varies according to the type of controller you are using. Instructions for
programming preset 95 are given below for various Pelco controllers.
CM6700/CM6800
1. Enter the number of the Spectra IV/Spectra IV SE dome system and press the CAM key.
2. Enter 95 and hold the PRESET key for two seconds.
3. In the Edit Preset menu, go to SET and press the ACK key. The main menu appears.
KBD200A/KBD300A (Direct Mode Only)
1. Enter 95.
2. Hold the PRESET key (approximately five seconds) until the main menu appears on the screen.
C3412M-D (12/08)21
Page 21
CM9500
1. Enter the number of the Spectra IV/Spectra IV SE dome system and press the CAM key. The main menu appears.
2. Highlight SETUP in the main menu and press the SELECT key.
3. Highlight CAM in the Setup menu and press the SELECT key.
4. Highlight PRESET in the Camera menu and press the SELECT key.
5. Enter 95 and press the F1 key. The main menu appears.
CM9740/CM9760/CM9770/CM9780
1. Press the ESCAPE key to open the main menu. Select DEF. The Define submenu appears.
2. Enter your four-digit PIN if this is your first time entering this mode.
3. Enter 95 and select PRST. The main menu appears on the monitor.
4. Select the Quit icon to return to the default menu.
KBD4000/KBD4002
1. Press the SPOT MONITOR key.
2. Enter 95, then hold the PRESET key (approximately five seconds) until the main menu appears on the screen.
MPT9500
Standard Coaxitron Mode
1. Enter 95 and press the PRESET SET key.
2. Position the asterisk in the YES row and press the F1 key. The main menu appears.
Extended Coaxitron or RS-485 Mode
1. Enter 95 and press the PRESET SET key.
2. Press the F2 key. The main menu appears.
22C3412M-D (12/08)
Page 22
NET300/NET350/NET4001A
1. Check the Set box.
2. Click the preset 95 button. The main menu appears.
ENDURA WORKSTATION
1. Right-click in the video pane of the Spectra IV/Spectra IV SE dome system.
2. Click Preset and then click Select Preset.
3. Enter 95 and then click OK.
VCD5000
1. Enter 95 for the preset action. The shortcuts menu appears.
The language for the on-screen menus is selectable. Available languages include English,
Spanish, French, German, Italian, Portuguese, Russian, Polish, Turkish, and Czech. The factory
default language is English.
To change the display language:
1. Use the joystick to position the cursor beside LANGUAGE.
2. Press Iris Open. The cursor moves to the right, beside the current, selected language.
3. Move the joystick up or down to view selections. Press Iris Open to enter selection.
All on-screen menus are changed to the selected language.
*This setting applies only to Pressurized Spectra IV dome systems.
SERIAL #
DOME DRIVE MODEL
BACK BOX MEMORY
SOFTWARE VERSION
BUILD
FONT VERSION
COMM
D ADDRESS
P ADDRESS
CM9500 MODE
32 PRESETS
PROTOCOL
PRESSURIZED*
<ADDITIONAL>
BACK
EXIT
The System Information menu displays the dome drive model, software version, available
memory, DIP switch information, and other diagnostic information.
System settings cannot be changed using this menu; this information is for reference only.
Use the following steps to display the System Information menu:
1.Use the joystick to position the cursor beside SYSTEM INFORMATION.
2.Press Iris Open. The SYSTEM INFORMATION menu opens.
DIP SWITCH INFORMATION
The DIP Switch Information menu displays the dome drive’s current DIP switch settings. This
provides a way to remotely view the DIP switch settings without removing the dome drive from
the back box.
DIP SWITCH INFORMATION
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 9 0
SW1[- - - - - - - -] SW2[- - - - - - - - - -]
SW1 1-8 :
D ADDRESS 1
P ADDRESS 1
SW2 1 : 32 PRESETS. OFF
SW2 2 : CM9500 MODE. OFF
SW2 3 : COAX SPIV
SW2 4-5 : RS422 <->
SW2 6-8 : COMM. 2400.N.8.1
SW2 9 : UTC SOURCE. COAX
SW2 10 : TX/RX TERM.. OFF
PRESS IRIS OPEN TO CONTINUE
ADDITIONAL
FREE MEMORY
LAST RESET
AZIMUTH ZERO OFFSET
MOTOR ACTIVE
CAMERA ACTIVE
VIDEO LEVEL
CAMERA MODEL
LANGUAGE 1
LANGUAGE 2
LANGUAGE 3
LANGUAGE 4
LANGUAGE 5
LANGUAGE 6
LANGUAGE 7
LANGUAGE 8
LANGUAGE 9
LANGUAGE 10
<DIPSWITCH INFORMATION>
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
PRESET LABEL
ZONE LABEL
ZOOM
AZIMUTH/ELEVATION
DIRECTION
ALARM MESSAGE
DATE/TIME
EVENT LABEL
<LABEL POSITIONS>
RESTORE FACTORY DEFAULTS
BACK
EXIT
Display setup allows you to program how labels are displayed on the monitor. The following
labels are available:
PRESET LABEL: Identifies preset.
ZONE LABEL: Identifies zone.
ZOOM: Identifies the amount of magnification.
AZIMUTH
1
/ELEVATION2: Amount of pan from zero degrees vertical and the amount of tilt from
zero degrees horizontal.
DIRECTION: Displays compass direction.
ALARM MESSAGE: Displays activated alarm.
DATE/TIME: Displays current date and time.
EVENT LABEL: Displays activated event.
A preset label is displayed when a preset is called. A zone label is displayed when the system
moves into a zone. The zoom ratio label is displayed when zoom is activated. Azimuth/elevation
and direction labels are displayed when pan/tilt is activated. An alarm message appears on the
monitor when an alarm occurs. An event label appears on the monitor when an event occurs.
The following settings are available for each label except date and time:
OFF: Label is not displayed when activated.
CONSTANT: The label is continually displayed when activated.
2 SECONDS: The label is displayed for 2 seconds after activation.
5 SECONDS: The label is displayed for 5 seconds after activation.
10 SECONDS: The label is displayed for 10 seconds after activation.
The settings for date and time are ON or OFF.
1
Azimuth is the pan angle from zero to 359 degrees.
2
Elevation is the tilt position from zero (horizon) to -90 degrees.
*This setting applies only to Pressurized Spectra IV dome systems.
Pelco has calibrated settings that optimize the white balance and the picture for several lighting
conditions. There are three settings:
T1 (default): For use in outdoor applications.
T2: For use in indoor applications.
T3: (Available only with 23X models.) For use in applications that use sodium lighting.
AUTO FOCUS
Auto focus allows the lens to remain in focus during zoom-in, zoom-out, and motion functions.
There are two auto focus settings:
ON (default): If auto focus mode is set to ON, the camera will focus automatically when using
pan, tilt, and zoom (PTZ) functions.
OFF: Focus is operated manually. To focus, press the Focus Far or Focus Near button on the
controller.
Sure Focus
When sure focus is enabled and all PTZ motions are stopped, the camera will attempt to find a
fixed focus position and lock to an object in the scene. If a focus lock is acquired or a specific
amount of time has expired with no focus lock, the focus position remains fixed until PTZ is
resumed.
CAMERA
TYPE OF LIGHTING
AUTO FOCUS
SURE FOCUS
ZOOM LIMIT
ZOOM SPEED
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
<ADVANCED SETTINGS>
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
TYPE OF LIGHTING
AUTO FOCUS
SURE FOCUS
ZOOM LIMIT
ZOOM SPEED
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
<ADVANCED SETTINGS>
BACK
EXIT
ZOOM SPEED
Zoom speed allows the user to define how fast the dome will go from full wide zoom to the16X,
18X, 22X, 23X, or 35X optical zoom.
Available zoom speed settings for 16X models include:
HIGH: 1.9 seconds
MEDIUM (default): 3.6 seconds
LOW: 6.0 seconds
Available zoom speed settings for 18X and 23X models include:
HIGH: 2.9 seconds
MEDIUM (default): 4.2 seconds
LOW: 5.8 seconds
Available zoom speed settings for 22X models include:
HIGH: 2.4 seconds
MEDIUM (default): 3.9 seconds
LOW: 6.3 seconds
Available zoom speed settings for 35X models include:
HIGH: 3.2 seconds
MEDIUM (default): 4.6 seconds
LOW: 6.6 seconds
Note: When using the HIGH setting, the image may be out of focus until zooming stops.
LOW LIGHT LIMIT
Low light limit is the maximum duration, in fractions of a second, that the electronic shutter will
remain open in low light conditions. The default setting is 2.
Settings include the following:
2 = 1/2 second 8 = 1/8 second30 = 1/30 second
4 = 1/4 second15 = 1/15 second60 = 1/60 second
*This setting applies only to Pressurized Spectra IV dome systems.
The 18X, 23X, and 35X cameras have two modes of operation: color, and black-white. You can
increase sensitivity in low light conditions by switching to black-white mode (removing the IR cut
filter). Color mode is preferred in normal lighting conditions.
The following are the settings for the IR cut filter:
OFF: Manual operation is controlled by preset 88 (filter IN) and 89 (filter OUT).
AUTO (default): Automatic operation is controlled by the auto IR level setting.
IN: Images are always displayed in color mode.
OUT: Images are always displayed in black-white mode.
Note: The IN and OUT settings are only available when editing camera settings through the
Presets menu (refer to Presets on page 57).
Low Light Focus
If you are using an IR illuminator, the low light focus feature of the camera can be tuned to
correspond to the setting of the illuminator.
There are three low light focus settings:
OFF (default): Low light focus is not activated.
850NM: Low light focus is tuned to 850 nm (nanometers).
950NM: Low light focus is tuned to 950 nm.
CAMERA
TYPE OF LIGHTING
AUTO FOCUS
SURE FOCUS
ZOOM LIMIT
ZOOM SPEED
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
<ADVANCED SETTINGS>
BACK
EXIT
Auto IR Level
The auto IR level is the light level at which the infrared filter switches IN or OUT.
Following are the available settings for the auto IR level:
DUSK (default): Approximately 6 lux (black-white); approximately 13 lux (color).
DARK: Approximately 0.1 lux (black-white); approximately 2 lux (color).
Notes:
• If backlight compensation is ON and the IR cut filter switches OUT in normal lighting
conditions, adjust the Auto IR Level to a darker setting. Refer to Backlight Compensation (BLC)
on page 45.
• Low light does not mean no light. Some type of illumination is required (street light, IR light,
etc.). The camera is not sensitive to IR light when the IR cut filter is IN.
*This setting applies only to Pressurized Spectra IV dome systems.
TYPE OF LIGHTING
AUTO FOCUS
SURE FOCUS
ZOOM LIMIT
ZOOM SPEED
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
<ADVANCED SETTINGS>
BACK
EXIT
SHUTTER SPEED
Shutter speed is the duration of the electronic shutter. Program shutter speed to operate
automatically (Auto) or manually (Numeric Value).
AUTO (default): The electronic shutter speed is set automatically by the amount of light sensed
by the camera.
NUMERIC VALUE: Spectra IV/Spectra IV SE dome systems have several numerical shutter
speed settings. The higher the number, the faster the electronic shutter.
The slowest shutter speed setting is 2 = 1/2 second.
The fastest setting is 30,000 = 1/30,000 second.
Increasing the shutter speed lowers the light sensitivity and reduces the streaking of fast moving
objects.
Set the shutter speed to 100 if you are using an NTSC camera in a 50 Hz environment. This will
eliminate any flicker that may occur in the picture.
AGC LIMIT
AGC limit allows users to adjust how the system balances AGC (automatic gain control) and
electronic shutter in low light conditions. As scene lighting decreases, the system will
automatically adjust, adding a mixture of AGC and slow shutter according to the AGC limit
setting. AGC limit can be set between 0 and 40, with 40 applying maximum AGC before slow
shutter. In contrast, setting AGC limit to 0 will force the system software to apply maximum slow
shutter (as defined by the low light limit setting) before any AGC is applied. The default AGC
settings vary depending on camera model.
Note: The maximum slow shutter that the system will achieve is 1/2 second shutter (refer to
Low Light Limit on page 40).
ADVANCED SETTINGS
SHUTTER SPEED
AGC LIMIT
AUTO IRIS
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO SHARPNESSSHARPNESS LEVEL
AUTO WHITE BALANCE
R GAIN
B GAIN
BACKLIGHT COMP
VIDEO LEVEL
SENSOR SCAN MODE
FIELD ALIGN
E. IMAGE STABILIZER
IMAGE ENHANCEMENT
LOW LUX NOISE REDUCTION
WIDE DYNAMIC RANGE
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
TYPE OF LIGHTING
AUTO FOCUS
SURE FOCUS
ZOOM LIMIT
ZOOM SPEED
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
<ADVANCED SETTINGS>
BACK
EXIT
AUTO IRIS
Auto iris is the lens function that automatically opens and closes the iris in response to changing
light conditions.
Program the auto iris to operate automatically or at a user-defined level.
OFF: Auto iris is disabled, and control is always manual.
AUTO (default): The iris is adjusted automatically to produce a constant video output as
determined by the auto iris level setting.
If auto iris is in the auto mode, it will remain that way until the iris is manually opened or closed.
The dome will return to auto mode when it is panned or tilted more than 15 degrees.
Auto Iris Level
Auto iris level is the numeric value the auto iris uses to maintain the brightness level of the
camera. Increase the value to brighten the scene. Decrease the value to darken the scene.
This setting can be adjusted if the video level in the auto iris mode is too bright or too dark.
Note: If backlight compensation is ON, decrease the auto iris level setting.
Auto Iris Peak
Increasing the peak value will cause the auto iris circuit to react more to highlights or “peaks” in
the picture. Decreasing this value will cause it to use the average video level to adjust the iris.
ADVANCED SETTINGS
SHUTTER SPEED
AGC LIMIT
AUTO IRIS
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO SHARPNESSSHARPNESS LEVEL
AUTO WHITE BALANCE
R GAIN
B GAIN
BACKLIGHT COMP
VIDEO LEVEL
SENSOR SCAN MODE
FIELD ALIGN
E. IMAGE STABILIZER
IMAGE ENHANCEMENT
LOW LUX NOISE REDUCTION
WIDE DYNAMIC RANGE
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
TYPE OF LIGHTING
AUTO FOCUS
SURE FOCUS
ZOOM LIMIT
ZOOM SPEED
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
<ADVANCED SETTINGS>
BACK
EXIT
ADVANCED SETTINGS
SHUTTER SPEED
AGC LIMIT
AUTO IRIS
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO SHARPNESSSHARPNESS LEVEL
AUTO WHITE BALANCE
R GAIN
B GAIN
BACKLIGHT COMP
VIDEO LEVEL
SENSOR SCAN MODE
FIELD ALIGN
E. IMAGE STABILIZER
IMAGE ENHANCEMENT
LOW LUX NOISE REDUCTION
WIDE DYNAMIC RANGE
BACK
EXIT
AUTO WHITE BALANCE
This feature automatically processes the viewed image to retain color balance over a color
temperature range. The default setting for auto white balance is ON.
R GAIN: Adjusts the picture output in the red range. As you change the value, you will see the
color change on your monitor.
B GAIN: Adjusts the picture output in the blue range. As you change the value, you will see the
color change on your monitor.
*This setting applies only to Pressurized Spectra IV dome systems.
TYPE OF LIGHTING
AUTO FOCUS
SURE FOCUS
ZOOM LIMIT
ZOOM SPEED
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
<ADVANCED SETTINGS>
BACK
EXIT
BACKLIGHT COMPENSATION (BLC)
If a bright backlight is present, the subjects in the picture may appear dark or as a silhouette.
Backlight compensation enhances objects in the center of the picture. The dome uses the center
of the picture to adjust the iris. If there is a bright light source outside of this area, it will wash
out to white. The camera will adjust the iris so that the object in the sensitive area is properly
exposed.
There are two backlight compensation settings:
OFF (default): Backlight compensation is not activated.
ON: Backlight compensation is activated.
If backlight compensation is ON, decrease the auto iris level setting and adjust the auto IR level
to a darker setting. Refer to Auto Iris Level on page 43 and Auto IR Level section on page 41.
VIDEO LEVEL
Set the video output to one of the following options:
NORMAL: 1.0 Vp-p.
HIGH (default setting): 1.2 Vp-p. to compensate for losses in video cable.
ADVANCED SETTINGS
SHUTTER SPEED
AGC LIMIT
AUTO IRIS
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO SHARPNESSSHARPNESS LEVEL
AUTO WHITE BALANCE
R GAIN
B GAIN
BACKLIGHT COMP
VIDEO LEVEL
SENSOR SCAN MODE
FIELD ALIGN
E. IMAGE STABILIZER
IMAGE ENHANCEMENT
LOW LUX NOISE REDUCTION
WIDE DYNAMIC RANGE
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.*This setting applies only to Pressurized Spectra IV dome systems.
TYPE OF LIGHTING
AUTO FOCUS
SURE FOCUS
ZOOM LIMIT
ZOOM SPEED
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
<ADVANCED SETTINGS>
BACK
EXIT
ADVANCED SETTINGS
SHUTTER SPEED
AGC LIMIT
AUTO IRIS
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO SHARPNESSSHARPNESS LEVEL
AUTO WHITE BALANCE
R GAIN
B GAIN
BACKLIGHT COMP
VIDEO LEVEL
SENSOR SCAN MODE
FIELD ALIGN
E. IMAGE STABILIZER
IMAGE ENHANCEMENT
LOW LUX NOISE REDUCTION
WIDE DYNAMIC RANGE
BACK
EXIT
SENSOR SCAN MODE
(Applies only to 35X models.)
Sensor scan mode controls the internal processing of the camera's image sensor. The data
scanned from the image sensor at each field time is used for the internal image control
algorithms and digital signal processing (DSP).
Note: When changing from PROGRESSIVE to INTERLACED, or vice-versa, the camera restarts to
establish the new setting.
There are two sensor scan modes:
PROGRESSIVE (default): Produces a higher quality image by using each line scanned from the
image sensor.
INTERLACED: Produces a slight increase in sensitivity by using blended data from pairs of lines
scanned from the image sensor.
When sensor scan mode is set to INTERLACED, the wide dynamic range and image enhancement
features are automatically disabled. There may be additional effects, such as a degradation of
the signal-to-noise ratio, degradation of the color reproduction, and a loss of motion detection for
presets configured with motion detection.
FIELD ALIGN
(Applies only to 18X, 23X, and 35X models.)
Field align determines whether the camera produces progressive segmented frame output (PsF)
or interlaced frame output. Analog video from the camera is always output in separate fields as
required for compatibility. This feature allows PsF to be recombined by an encoding device
without a time difference between fields, as is typically seen from interlaced analog video
output. Enabling field align requires that the encoding device you are using always combines the
odd and even fields in the specified order.
There are three field alignment settings:
OFF (default): Field alignment is disabled. Use this setting if you are using an analog device/
system or a digital encoder that does not support PsF.
ODD: Arranges the odd field for a particular video frame before the even field for that frame.
EVEN: Arranges the even field for a particular video frame before the odd field for that frame.
Notes:
• If you enable field alignment by selecting ODD or EVEN, you must disable any deinterlacing
settings for the encoding device to achieve maximum resolution.
• The ODD and EVEN settings require that the sensor scan mode is set to PROGRESSIVE. If field
align is set to ODD or EVEN, the sensor scan mode automatically changes to PROGRESSIVE.
TYPE OF LIGHTING
AUTO FOCUS
SURE FOCUS
ZOOM LIMIT
ZOOM SPEED
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
<ADVANCED SETTINGS>
BACK
EXIT
ELECTRONIC IMAGE STABILIZATION
(Applies only to 35X models.)
Electronic image stabilization is a feature of the camera that can compensate for some forms of
external influences. In all cases, care should be taken to make sure that any dome system is
mounted to a rigid location.
In the event that vibration is introduced to the dome system, a user can select one of the
electronic image stabilization settings in the menu. The available settings are OFF, 5 Hz, and
10 Hz. Users should apply each of the settings to the camera to see which one best addresses
the vibration that is affecting the video quality.
Electronic image stabilization will not correct for all ranges of vibration. If either of the settings
fails to eliminate the vibration seen in the video, other measures should be taken to isolate the
vibration or to seek a more rigid mounting location.
Notes:
• When electronic image stabilization is applied, digital slow shutter and wide dynamic range
are disabled. Zoom, image resolution, and viewing angle are also limited when this feature
is activated.
• Electronic image stabilization cannot be used while in a preset that has motion detection
activated.
ADVANCED SETTINGS
SHUTTER SPEED
AGC LIMIT
AUTO IRIS
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO SHARPNESSSHARPNESS LEVEL
AUTO WHITE BALANCE
R GAIN
B GAIN
BACKLIGHT COMP
VIDEO LEVEL
SENSOR SCAN MODE
FIELD ALIGN
E. IMAGE STABILIZER
IMAGE ENHANCEMENT
LOW LUX NOISE REDUCTION
WIDE DYNAMIC RANGE
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
TYPE OF LIGHTING
AUTO FOCUS
SURE FOCUS
ZOOM LIMIT
ZOOM SPEED
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
<ADVANCED SETTINGS>
BACK
EXIT
IMAGE ENHANCEMENT
(Applies only to 35X models.)
The image enhancement feature improves the definition of objects, lines, or text in high contrast
areas, making them appear sharper.
There are two image enhancement settings:
DEFAULT: Image enhancement is not activated.
ENHANCED: Image enhancement is activated.
Warning: When using this feature be aware that picture noise, although unnoticeable to
the eye, will increase and may cause compression rate changes in DVRs, NVRs, and
network devices.
LOW LUX NOISE REDUCTION
(Applies only to 18X and 23X models.)
Low lux noise reduction helps to reduce video noise in low light scenes. When enabled, low lux
noise reduction is directly affected by the AGC settings for the dome system.
The following are the low lux noise reduction settings:
ON (default): Low lux noise reduction is enabled. As the scene darkens and AGC increases, the
noise reduction effect automatically increases. As noise reduction increases, you may also notice
some afterimaging and a slight reduction in color saturation.
OFF: Low lux noise reduction is disabled.
ADVANCED SETTINGS
SHUTTER SPEED
AGC LIMIT
AUTO IRIS
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO SHARPNESSSHARPNESS LEVEL
AUTO WHITE BALANCE
R GAIN
B GAIN
BACKLIGHT COMP
VIDEO LEVEL
SENSOR SCAN MODE
FIELD ALIGN
E. IMAGE STABILIZER
IMAGE ENHANCEMENT
LOW LUX NOISE REDUCTION
WIDE DYNAMIC RANGE
TYPE OF LIGHTING
AUTO FOCUS
SURE FOCUS
ZOOM LIMIT
ZOOM SPEED
LOW LIGHT LIMIT
IR CUT FILTER
LOW LIGHT FOCUS
AUTO IR LEVEL
<ADVANCED SETTINGS>
BACK
EXIT
WIDE DYNAMIC RANGE
(Applies only to 23X and 35X models.)
Wide dynamic range (WDR) balances the brightest and darkest sections of a scene to produce a
picture that is better balanced in lighting and provides more detail.
Available settings are OFF and ON; the default setting is OFF. When wide dynamic range is set to
ON the frame rate is reduced from the standard 30–15 frames per second (fps). Also, when this
setting is ON the iris will not close completely, even in manual mode.
Note: Wide dynamic range is disabled when electronic image stabilization is set to 5 Hz or 10 Hz.
Wide Dynamic Range ONWide Dynamic Range OFF
ADVANCED SETTINGS
SHUTTER SPEED
AGC LIMIT
AUTO IRIS
AUTO IRIS LEVEL
AUTO IRIS PEAK
AUTO SHARPNESSSHARPNESS LEVEL
AUTO WHITE BALANCE
R GAIN
B GAIN
BACKLIGHT COMP
VIDEO LEVEL
SENSOR SCAN MODE
FIELD ALIGN
E. IMAGE STABILIZER
IMAGE ENHANCEMENT
LOW LUX NOISE REDUCTION
WIDE DYNAMIC RANGE
When the camera tilts downward and goes just beyond the vertical position, the dome rotates
180 degrees. When the dome rotates (flips), the camera starts moving upward as long as you
continue to hold the joystick in the down position. Once you let go of the joystick after the dome
rotates, joystick control returns to normal operation. The auto-flip feature is useful for following a
person who passes directly beneath the dome.
There are two auto flip modes:
ON (default): Auto flip mode is enabled.
OFF: Auto flip mode is disabled.
PROPORTIONAL PAN
Proportional pan automatically reduces or increases the pan and tilt speeds in proportion to the
amount of zoom. At telephoto zoom settings, the pan and tilt speeds will be slower for a given
amount of joystick deflection than at wide zoom settings. This keeps the image from moving too
fast on the monitor when there is a large amount of zoom.
There are three proportional pan modes:
ON (default): Enables the proportional pan mode.
OFF: Disables proportional pan mode. The pan speed will not depend on the amount of zoom.
2X: Increases the speed of the proportional pan mode to twice that used when proportional pan
is set to ON.
MOTION
AUTO FLIP
PROPORTIONAL PAN
PARK TIME (MINUTES)
PARK ACTION
SCAN SPEED (DEG/S)
PRESET FREEZE FRAME
Scan speed is the degrees per second that the dome will pan when in a scan mode. Scan speed is
adjustable from 1 to 40 degrees per second through the programming menu. The default setting
is 25 degrees per second.
PRESET FREEZE FRAME
This feature freezes the scene on the monitor when going to a preset. This allows for smooth
transition from one preset scene to another. Preset freeze frame also reduces bandwidth when
used with digital network systems such as PelcoNet™ and guarantees that blanked areas will not
be revealed when going to a preset.
There are three preset freeze frame settings:
ON: The image on the screen freezes when a preset is called. When the dome reaches the
preset, the image is unfrozen and the preset scene is displayed.
OFF: The image is never frozen.
AUTO (default): Freeze frame is turned on automatically if window blanking is ON. If window
blanking is OFF, freeze frame is off.
MOTION
AUTO FLIP
PROPORTIONAL PAN
PARK TIME (MINUTES)
PARK ACTION
SCAN SPEED (DEG/S)
PRESET FREEZE FRAME
Azimuth is the pan angle from zero to 359 degrees. Azimuth zero is the pan position you specify to
be the zero degree point. Azimuth zero is normally set to magnetic north. Once set, azimuth and
compass readings are based on the set Azimuth Zero point.
To program azimuth zero:
1. Use the joystick to position the cursor beside SET AZIMUTH ZERO.
2. Press Iris Open.
3. Follow the directions displayed on the monitor.
To clear azimuth zero:
1. Use the joystick to position the cursor beside CLEAR AZIMUTH ZERO.
2. Press Iris Open.
3. Follow the directions displayed on the monitor.
MOTION
AUTO FLIP
PROPORTIONAL PAN
PARK TIME (MINUTES)
PARK ACTION
SCAN SPEED (DEG/S)
PRESET FREEZE FRAME
Line sync refers to a programmable function that allows you to synchronize all cameras within a
matrix system.
Spectra IV and Spectra IV SE dome systems automatically sense V-Sync input. No line sync setup
is required for Pelco control systems that provide a V-Sync signal.
For matrix systems that do not output V-Sync, there are two settings for line synchronization:
ON (default): Adjusts the phase of the line sync to synchronize input power. Line sync phase
settings range from zero to 359 degrees.
OFF: The dome synchronizes to the internal clock.
LINE SYNC
LINE SYNC
LINE SYNC PHASE
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
56C3412M-D (12/08)
Page 56
PRESETS
The model of the back box you are using limits the number of programmable presets that can be stored and retrieved in the
back box memory. If you are using an older model back box, you may program and use up to the maximum number of
presets available to the dome drive. However, if the dome drive is changed, the back box model will limit the number of
stored presets available to the new dome drive. Refer to the table below for more information.
The Spectra IV dome system, which includes 16X and 18X models, has 128 preset positions. The programmable presets
are numbered 1–32, 35–82, and 100–150.
The Spectra IV SE dome system, which includes 22X, 23X, and 35X models, has 256 preset positions. The programmable
presets are numbered 1–32, 35–82, and 100–256.
Note: The number of available presets may be limited by the head-ins, controllers, and DVRs that are connected to your
dome system.
Each of the user-definable presets can be programmed to use pan, tilt, camera settings, and motion detection.
The following presets are predefined for specific functions:
PresetAction
33:Flip command. Pans the dome drive 180 degrees.
34:Pan zero command. Directs the dome drive to the factory-determined zero reference point.
83–87:Reserved.
88:IR filter IN (color).
89:IR filter OUT (black-white).
90–91:Manual limit stops.
92–93:Scan limit stops.
94:Reserved.
95:Select main programming menu.
96:Stop a scan.
97:Random scanning.
98:Frame scanning.
99:Start auto scanning
REFERENCE INFORMATION
AZIMUTH ELEVATION ZOOM RATIO CUSTOM CAMERA SETTINGS -
4. Edit preset camera settings:
a. Use the joystick to position the cursor beside EDIT CAMERA SETTINGS.
b. Press Iris Open. The EDIT CAMERA SETTINGS window appears on the monitor. Refer
to Camera on page 38 and Advanced Camera Settings on page 42 to change preset
camera settings.
c. To edit the camera settings schedule, use the joystick to position the cursor beside
EDIT SCHEDULE. Press Iris Open.
The Edit Schedule menu is a duplicate of the Edit Event menu (refer to Event on
page 80) with the following exceptions. In the Edit Schedule menu, the event type
cannot be changed. Also, the Holiday feature cannot be accessed from the Edit
Schedule menu.
For instructions on changing the features in the Edit Schedule menu, refer to Edit Event on page 83.
Notes:
• For 23X and 35X models, there are two additional options available for the IR cut filter that are
only available when programming a preset. The additional settings are IN and OUT. If the IR cut
filter is set to IN, the preset scene will be in color. If the IR cut filter is set to OUT, the preset
scene will be in black-white.
• You can copy camera settings from one preset to another preset. To copy camera settings do
the following:
(1) Use the joystick to position the cursor beside COPY CAMERA SETTINGS.
(2) Press Iris Open. The cursor moves to the right.
(3) Move the joystick up or down to view selections. Press Iris Open to enter selection.
*This setting applies only to Pressurized Spectra IV dome systems.
REFERENCE INFORMATION
AZIMUTH
ELEVATION
ZOOM RATIO
CUSTOM CAMERA SETTINGS
ACTIVATE AUX COMMAND
(Applies only to 23X and 35X models.)
Motion detection can be programmed to trigger an auxiliary command when motion is detected.
The following are the settings for ACTIVATE AUX:
OFF (default): Motion detection will not trigger an AUX command.
1: Triggers a command to AUX 1.
2: Triggers a command to AUX 2.
AUX TIME
(Applies only to 23X and 35X models.)
Aux time is the length of time the auxiliary will remain on after motion is detected. Available
settings for AUX TIME are 1–60 seconds.
EDIT SCHEDULE
The Edit Schedule menu is a duplicate of the Edit Event menu (refer to Event on page 80) with
the following exceptions. In the Edit Schedule menu, the event type cannot be changed. Also,
the Holiday feature cannot be accessed from the Edit Schedule menu.
For instructions on changing the features in the Edit Schedule menu, refer to Edit Event on
page 83.
MOTION DETECTION
MOTION DETECTION ENABLED
<EDIT DETECTION AREAS>
ACTIVATE AUX
AUX TIME (SECS)
BACK
EXIT
*This setting applies only to Pressurized Spectra IV dome systems.
PATTERN NUMBER
<PROGRAM PATTERN>
<CLEAR PATTERN>
<EDIT SCHEDULE>
BACK
EXIT
REFERENCE INFORMATION
PATTERN USAGE
REMAINING
A pattern is a memorized, repeating series of pan, tilt, zoom, and preset functions that can be
recalled with a command from a controller or automatically by a programmed function (alarm,
park, event, or power-up).
Both 16X and 18X models have one user-defined pattern available. The 22X, 23X, and 35X models
can handle up to eight patterns. Pattern length is based upon memory usage rather than a fixed
amount of time. The complexity of a pattern will determine the amount of storage available to
program other patterns.
Note: In most cases, the memory available will allow for ample time to schedule typical
patterns. If the scheduled patterns are unusually lengthy or complex, there is a possibility that
there may not be enough remaining memory to program all eight patterns for the 22X, 23X, and
35X models.
To program a pattern:
1. Use the joystick to position the cursor beside PATTERN NUMBER. Press Iris Open.
The cursor moves to the right.
2. Move the joystick up or down to view selections. Press Iris Open to enter selection.
3. Use the joystick to position the cursor beside PROGRAM PATTERN.
4. Press Iris Open. The Patterns programming window appears on the monitor.
5. Follow the directions displayed on the monitor.
After a pattern is programmed, the remaining storage percentage is displayed on the screen.
This is the amount of memory available to program the remaining patterns.
To clear a pattern:
1. Use the joystick to position the cursor beside CLEAR PATTERN.
2. Press Iris Open.
3. Follow the directions displayed on the monitor.
To edit the pattern schedule:
The Edit Schedule menu is a duplicate of the Edit Event menu (refer to Event on page 80) with
the following exceptions. In the Edit Schedule menu, the event type cannot be changed. Also,
the Holiday feature cannot be accessed from the Edit Schedule menu.
For instructions on changing the features in the Edit Schedule menu, refer to Edit Event on
page 83.
Note: When programming one or more presets within a pattern, use the normal controller
commands to call a preset. Not all controllers can start all patterns. However, any of the patterns
can be automatically started with park, power-up, event, and alarm functions.
*This setting applies only to Pressurized Spectra IV dome systems.
A zone is a pan area, defined by a left and right limit, on the 360-degree pan plane. The
Spectra IV and Spectra IV SE dome systems are capable of eight zones, each with a 20-character
label.
To program a zone:
1. Use the joystick to position the cursor beside ZONE NUMBER. Press Iris Open, and the
cursor moves to the right.
2. Move the joystick up or down to view selections. Press Iris Open to enter selection.
3. Use the joystick to position the cursor beside EDIT ZONE.
4. Press Iris Open. The Zone programming window appears on the monitor.
5. Follow the directions displayed on the monitor. After the left and right limit stops are set,
the Zones menu reappears with the ZONE ENABLED option set to YES.
To edit a zone label:
1. Use the joystick to position the cursor beside EDIT ZONE LABEL.
2. Press Iris Open. The following information appears on the monitor:
LABEL FOR ZONE
ZONE NUMBER
1234567890 OK
ABCDEFGHIJ CANCEL
KLMNOPQRST
UVWXYZ.,-/ SPACE
abcdefghij BACKSPACE
klmnopqrst
uvwxyz*;:
------
ZONES
ZONE NUMBER
* * * ZONE NOT DEFINED * * *
<EDIT ZONE LABEL>
<EDIT ZONE>
ZONE ENABLED
ZONE BLANKING
<CLEAR ZONE>
BACK
EXIT
To clear a character, position the cursor beside BACKSPACE, and then press Iris Open.
4. When the label is completed, move the cursor to OK. Press Iris Open to return to the Zones
menu.
To disable a zone (a zone is enabled automatically when it is programmed) or to blank a zone:
1. Move the cursor beside ZONE ENABLED or ZONE BLANKING.
2. Press Iris Open. The cursor moves to the right.
3. Move the joystick up or down to view selections. Press Iris Open to enter selection.
To clear a zone:
1. Use the joystick to position the cursor beside CLEAR ZONE.
2. Press Iris Open. Follow the instructions on the screen.
*This setting applies only to Pressurized Spectra IV dome systems.
64C3412M-D (12/08)
3. Use the joystick to position the cursor beside a character. Press Iris Open to enter selection.
Window blanking allows a user to program four-sided areas that cannot be viewed by the
operator of the dome system. A blanked area will move with pan and tilt functions and
automatically adjust in size as the lens zooms telephoto and wide.
The 16X and 18X models have one user-defined window blank available. The 22X, 23X, and 35X
models have eight available user-defined window blanks.
Spectra IV and Spectra IV SE dome systems have two styles of window blanking: Gray and Smear.
If the style is set to Gray, the blanked area is covered with a solid gray window. If Smear is
selected images behind the window will be noticeable but not distinguishable.
1. Use the joystick to position the cursor beside WINDOW BLANKING. Press Iris Open.
The WINDOW BLANKING menu appears on the screen.
2. Move the joystick to position the cursor beside SET WINDOWS. Press Iris Open to enter.
3. Position the cursor beside WINDOW NUMBER. Press Iris Open. The cursor moves to the
right.
4. Move the joystick up or down to view selections. Press Iris Open to enter selection.
5. Use the joystick to position the cursor beside EDIT WINDOW LOCATION. Press Iris Open,
and then follow the instructions that appear on the screen. When all four corners are set,
the SET WINDOWS menu reappears, the blanked area is displayed, and the ENABLE
WINDOW option is set to YES.
Notes:
• Use the inside corner of the window selection tool as a guide
when selecting the upper left, upper right, bottom right, and
bottom left corners of the window.
• Set windows are not visible when editing a new window
location.
*This setting applies only to Pressurized Spectra IV dome systems.
6. The blanked area can be programmed to turn on or off at a specified zoom point. To set the
zoom point:
a. Use the joystick to position the cursor beside EDIT WINDOW ZOOM, and then press
Iris Open.
b. Zoom in to the point where you want window blanking to turn on. Press Iris Open to
set the zoom point.
Notes:
• Since the area is already blanked out, it may be difficult to determine when you want
window blanking to turn on. Reverse the window before setting the zoom point. When
finished reverse the window again to blank out the area.
• Increase the size of the window if any part of the blanked area is revealed during PTZ
operations.
WINDOW BLANKING
STYLE
BLANK ALL ABOVE
BLANK ALL BELOW
<SET WINDOWS>
BACK
EXIT
Window Blanking DisabledWindow Blanking Enabled
EDIT SCHEDULE
The Edit Schedule menu is a duplicate of the Edit Event menu (refer to Event on page 80) with the
following exceptions. In the Edit Schedule menu, the event type cannot be changed. Also, the
Holiday feature cannot be accessed from the Edit Schedule menu.
For instructions on changing the features in the Edit Schedule menu, refer to Edit Event on
page 83.
A blanked out area can be reversed to make it visible and the areas on both sides of it not visible.
The areas above and below the blanking area remain visible. Reversing the window a second
time will return it to its original condition.
CLEAR WINDOW
All areas that have been set for window blanking are cleared.
*This setting applies only to Pressurized Spectra IV dome systems.
Page 66
BLANK ALL ABOVE/BLANK ALL BELOW
The Blank All Above and Blank All Below options add additional flexibility to setting up privacy areas. These settings are
ideal for applications where a complete pan location needs to be blanked.
Table C. Window Blank Settings
Blank All AboveBlank All Below
Tilt Angle Blanked AreaTilt Angle Blanked Area
OFFNo blankingOFFNo blanking
0Horizon to 3° above horizon0Horizon to 92° below horizon
-103° above horizon to 10° below horizon-1010° to 92° below horizon
-203° above horizon to 20° below horizon-2020° to 92° below horizon
-303° above horizon to 30° below horizon-3030° to 92° below horizon
-403° above horizon to 40° below horizon-4040° to 92° below horizon
-503° above horizon to 50° below horizon-5050° to 92° below horizon
-603° above horizon to 60° below horizon-6060° to 92° below horizon
-703° above horizon to 70° below horizon-7070° to 92° below horizon
-803° above horizon to 80° below horizon-8080° to 92° below horizon
The Spectra IV SE dome systems have seven alarm inputs that can be programmed as high,
medium, or low priority. When an alarm is received, an input signal to the dome triggers the userdefined action (go to preset, run pattern, etc.) programmed for the alarm.
Note: Refer to the notation in step 6 for the limited alarm features available for 16X and 18X
models.
There are three global alarm settings:
RESUME: This mode lets the dome resume its previous activity (scan, pattern, or previous
position) after all alarms are cleared.
SEQUENCE: This is the time the dome will perform an alarm activity when more than one alarm
of the same priority occurs at the same time.
RESET DELAY: This is the amount of time the dome considers the alarm to be active after it has
physically cleared.
Use the following steps to program alarm settings.
1. Use the joystick to position the cursor beside ALARM SETTINGS. Press Iris Open.
2. Select the alarm number:
a. Use the joystick to position the cursor beside ALARM NUMBER.
b. Press Iris Open. The cursor moves to the right.
ALARMS
RESUME
SEQUENCE (SECS)
RESET DELAY (SECS)
<ALARM SETTINGS>
BACK
EXIT
ALARM SETTINGS
ALARM NUMBER
ALARM PRIORITY
ALARM ACTION
ACTIVATE AUX
ALARM CONTACT
<EDIT SCHEDULE>
BACK
EXIT
c. Move the joystick up or down to view selections. Press Iris Open to enter selection.
*This setting applies only to Pressurized Spectra IV dome systems.
a. Use the joystick to position the cursor beside ALARM PRIORITY.
b. Press Iris Open. The cursor moves to the right.
c. Move the joystick up or down to view the available selections. Available settings
include HIGH, MEDIUM, and LOW (default). If multiple alarms with different priorities
are active at the same time, the dome will only go to the alarms with the highest
priority.
a. Use the joystick to position the cursor beside ACTIVATE AUX.
b. Press Iris Open. The cursor moves to the right.
c. Move the joystick up or down to view the following available selections.
NO (default): Not activated.
1: An alarm action will close AUX 1.
2: An alarm action will close AUX 2.
d. Press Iris Open to enter selection.
Note: The AUX 1/AUX2 will stop when all the alarms assigned to it have cleared. If the
AUX1/AUX is set up as momentary, then it will be activated each time a new alarm is
activated.
6. Set the alarm contact:
a. Use the joystick to position the cursor beside ALARM CONTACT.
b. Press Iris Open. The cursor moves to the right.
c. Move the joystick up or down to view the following available selections.
N/O (default): Normally open.
N/C: Normally closed.
d. Press Iris Open to enter selection.
Note: The alarm contact feature is functional and available for 16X and 18X models only if
the dome drive is installed in a Spectra III SE or Spectra IV SE back box.
7. To edit the alarm schedule:
The Edit Schedule menu is a duplicate of the Edit Event menu (refer to Event on page 80)
with the following exceptions. In the Edit Schedule menu, the event type cannot be
changed. Also, the Holiday feature cannot be accessed from the Edit Schedule menu.
ALARM SETTINGS
ALARM NUMBER
ALARM PRIORITY
ALARM ACTION
ACTIVATE AUX
ALARM CONTACT
<EDIT SCHEDULE>
BACK
EXIT
70C3412M-D (12/08)
For instructions on changing the features in the Edit Schedule menu, refer to Edit Event on
page 83.
*This setting applies only to Pressurized Spectra IV dome systems.
AUX 1 MODE TOGGLE
DWELL TIME (SECS) 1
AUX 2 MODE TOGGLE
DWELL TIME (SECS) 1
<EDIT SCHEDULE>
BACK
EXIT
Note: If a 16X or 18X model dome drive is installed in a Spectra III SE or Spectra IV SE back box,
the auxiliary feature is functional and available. If a 16X or 18X model is installed in a standard
Spectra III or Spectra IV back box, the auxiliary feature is not available.
An auxiliary output is a programmable signal from the dome back box that can trigger another
device to operate. An auxiliary output is programmable to trigger from an alarm or from a controller.
An AUX 1 command from the controller will activate the relay in the dome and operate the device
that is connected to the relay. The output of AUX 1 can be connected to the alarm input of a
system switch to activate automatic monitor switching and recording.
An AUX 2 command from the controller will place a ground at the output of AUX 2 to operate the
device that is connected to it.
The following are the available AUX mode settings:
TOGGLE (default): Changes the state of the auxiliary output every time an AUX command
is received from the controller.
LATCHING: Must receive an AUX ON/AUX OFF command from the controller to turn the
auxiliary output on/off.
MOMENTARY: An AUX ON command from the controller turns the auxiliary output on for the
programmed DWELL TIME. The auxiliary output will automatically turn off when the dwell time
is finished.
EDIT SCHEDULE
The Edit Schedule menu is a duplicate of the Edit Event menu (refer to Event on page 80) with
the following exceptions. In the Edit Schedule menu, the event type cannot be changed. Also,
the Holiday feature cannot be accessed from the Edit Schedule menu.
For instructions on changing the features in the Edit Schedule menu, refer to Edit Event on
page 83.
*This setting applies only to Pressurized Spectra IV dome systems.
Title text is the label used to identify the camera viewed on the monitor. Up to 20 characters can
be used for a title.
To edit the title text label, do the following:
1.Use the joystick to position the cursor beside EDIT TITLE TEXT.
2.Press Iris Open. The following appears on the monitor:
EDIT TITLE TEXT
1234567890 OK
ABCDEFGHIJ CANCEL
KLMNOPQRST
UVWXY.,-/ SPACE
abcdefghij BACKSPACE
klmnopqrst
uvwxyz#&: *
3.Use the joystick to position the cursor beside a character. Press Iris Open to select the
character. To clear a character, position the cursor beside BACKSPACE, and then press Iris
Open.
4.When the title is completed, move the cursor to OK. Press Iris Open to return to the Title
Text m enu.
5.Enable the title text label by doing the following:
a. Move the cursor beside ENABLE TITLE TEXT.
b. Press Iris Open. The cursor moves to the right.
c. Move the joystick up or down to view the selections. Select ON and then press Iris
ENABLE TITLE TEXT
<EDIT TITLE TEXT>
BACK
EXIT
TITLE TEXT
*This setting applies only to Pressurized Spectra IV dome systems.
REPEAT
ACK ACTION
ACTIVATE AUX
<CURRENT READING>
RESET ALERT
BACK
EXIT
Note: The Alert option applies only to Pressurized Spectra IV dome systems. Spectra IV systems
that are not pressurized will not display this menu item.
Sensors strategically placed inside the pressurized dome system continually monitor pressure,
temperature, and dew point. If internal conditions reach unacceptable levels, an alert message
appears on the screen describing the alert condition. For example, if pressure drops below 1 psig,
LOW PRESSURE is displayed on the monitor.
The following system conditions will trigger an alert message:
System ConditionAlert Message
Temperature is above 140°F (60°C)HIGH TEMPERATURE
Temperature is below -40°F (-40°C)LOW TEMPERATURE
Pressure is above 13 PSIGHIGH PRESSURE
Pressure is below 1 PSIGLOW PRESSURE
The difference between the temperature and DEW POINT (HIGH HUMIDITY)
the dew point is less than or equal to 3°C.
The alert message will be repeatedly displayed until the system controller acknowledges the
alert condition by selecting ACK ALERT in the main menu. Once acknowledged, the alert message
changes to the programmed acknowledge action (ACK ACTION). If the alert condition remains
active after a period of time, the alert message reappears on the monitor, restarting the alert
message cycle. This cycle will continue to repeat until the alert condition is resolved.
REPEAT
This setting programs how often an alert message is repeatedly displayed until the system
controller acknowledges the alert condition. The following are the settings:
CONSTANT: The alert message is continuously displayed on the monitor until acknowledged.
15 MIN: The alert message is displayed every 15 minutes for a 15-second duration until
acknowledged.
30 MIN: The alert message is displayed every 30 minutes for a 15-second duration until
acknowledged.
60 MIN: The alert message is displayed every 60 minutes for a 15-second duration until
acknowledged.
OFF: The alert message is disabled and will not be displayed on the monitor.
REPEAT
ACK ACTION
ACTIVATE AUX
<CURRENT READING>
RESET ALERT
BACK
EXIT
ACK ACTION
Set ACK ACTION to program the frequency at which an alert message is displayed after the alert
condition has been acknowledged. The following settings are available:
ALWAYS ON: The alert message is displayed until alert conditions are cleared.
OFF 8 HRS: The alert message is turned off for 8 hours. Message returns after 8 hours if the
alert condition persists.
OFF 24 HRS: The alert message is turned off for 24 hours. Message returns after 24 hours if
the alert condition persists.
OFF 48 HRS: The alert message is turned off for 48 hours. Message returns after 48 hours if the
alert condition persists.
ACTIVATE AUX
This setting activates an auxiliary when an alert condition exists. Settings include the following
options:
NONE (default): Not activated.
1: An alert condition will close AUX 1.
2: An alert condition will close AUX 2.
CURRENT READING
The Current Reading menu displays the existing status of temperature, pressure, and dew point
inside the dome system. An arrow displayed to the left of a menu item denotes that an alert
condition exists.
An up arrow indicates the reading is over the threshold. A down arrow indicates the reading is
below the threshold.
The high temperature alert occurs if the temperature is above 140°F (60°C).
The low temperature alert occurs if the temperature is below -40°F (-40°C).
The high pressure alert occurs if the pressure is above 13 PSIG.
The low pressure alert occurs if the pressure is below 1 PSIG.
The dew point (high humidity) alert occurs if the difference between the temperature and the dew
point is less than or equal to 3°C.
CURRENT READING
TEMPERATURE
DEWPOINT
PRESSURE
REFRESH
BACK
EXIT
74C3412M-D (12/08)
Note: The normal operating temperature inside the unit will be greater than the temperature
outside the back box due to the heat emitted by the system’s electronics.
RESET ALERT
Reset alert clears the alert condition and removes the alert label from the monitor. The system
automatically checks internal conditions 60 seconds after reset. If conditions are still unacceptable,
the alert label reappears on the screen indicating further corrective action is required.
Spectra IV and Spectra IV SE feature password protection to prevent unauthorized changes to the
dome settings. An operator can open the System Information and Display Setup menus, but
cannot access any of the dome settings menus.
Controller/keyboard commands cannot override password-protected settings. If a keyboard is
used to set a preset, pattern, or zone, the Enter Password menu appears on the monitor.
The password must be entered before programming can continue.
At least one character must be entered to create a valid password.
PASSWORD
ENABLE PASSWORD
<EDIT PASSWORD>
BACK
EXIT
EDIT THE PASSWORD
---------1234567890 OK
ABCDEFGHIJ CANCEL
KLMNOPQRST
UVWXYZ.,-/ SPACE
abcdefghij BACKSPACE
klmnopqrst
uvwxyz*;:
*This setting applies only to Pressurized Spectra IV dome systems.
The clock is used to program the current date and time. The date and time set in the Clock menu
is used to program events. The date and time can also be displayed on the monitor when the
menus are not being accessed.
To program the clock, do the following:
1. Use the joystick to position the cursor beside TIME BASE. Press Iris Open. The following are
the settings for time base:
POWER LINE: This is the most accurate time base and is the preferred selection in areas
with a stable power line frequency.
INTERNAL CLOCK: The internal clock should be used in areas where the power line
frequency is not accurate.
a. Move the joystick up or down to view the selections.
b. Press Iris Open to select INTERNAL CLOCK or POWER LINE.
2. Use the joystick to position the cursor beside TIME FORMAT. Press Iris Open. Move the
joystick up or down to view the selections. Select 12 HOUR or 24 HOUR, and then press Iris
Open to confirm the time format.
3. Use the joystick to position the cursor beside SET TIME. Press Iris Open. Scroll through the
hours until the desired time appears. Use the joystick to move the cursor to the right. Scroll
through the minutes until the desired time appears. Press Iris Open to select the time.
4. Use the joystick to position the cursor beside DATE FORMAT. Press Iris Open. Move the
joystick up or down to select MM/DD/YYYY or DD/MM/YYYY. Press Iris Open to confirm
the date format.
5. Use the joystick to position the cursor beside SET DATE. Press Iris Open. Scroll through the
days, months, and years until the desired number appears. Press Iris Open to select the
date.
6. Use the joystick to position the cursor beside DAYLIGHT SAVINGS. Press Iris Open.
The following are the settings for daylight savings:
OFF: Daylight saving time will be turned off.
FIXED DATE: Daylight saving time occurs on the same date each year.
RELATIVE DATE: Daylight saving time occurs on a different date each year, such as the
first Sunday in April.
*This setting applies only to Pressurized Spectra IV dome systems.
C3412M-D (12/08)77
Page 77
7. If FIXED DATE was selected, the following appears on the monitor:
CLOCK
TIME BASE INTERNAL CLOCK
TIME FORMAT 12 HOUR
SET TIME 00:00 AM
DATE FORMAT MM/DD/YYYY
SET DATE 00/00/0000
DAYLIGHT SAVINGS FIXED DATE
TIME SHIFT 1 HOUR
START DATE
MONTH APRIL
DAY 1
START TIME 02:00 AM
END DATE
MONTH OCTOBER
DAY 1
END TIME 02:00 AM
BACK
EXIT
a. Use the joystick to position the cursor beside TIME SHIFT. Press Iris Open. Scroll through the options until the
desired selection appears. Press Iris Open to select the time shift.
b. Use the joystick to position the cursor beside the start date MONTH. Press Iris Open. Scroll through the options
until the desired month appears. Press Iris Open to select the month.
c. Use the joystick to position the cursor beside the start date DAY. Press Iris Open. Scroll through the options until
the desired date appears. Press Iris Open to select the day.
d. Use the joystick to position the cursor beside START TIME. Press Iris Open. Scroll through the hours until the
desired time appears. Use the joystick to move the cursor to the right. Scroll through the minutes until the
desired time appears. Press Iris Open to select the start time.
e. Repeat steps b–d for the ending date and time.
78C3412M-D (12/08)
Page 78
8. If RELATIVE DATE was selected, the following appears on the monitor:
CLOCK
TIME BASE INTERNAL CLOCK
TIME FORMAT 12 HOUR
SET TIME 00:00 AM
DATE FORMAT MM/DD/YYYY
SET DATE 00/00/0000
DAYLIGHT SAVINGS RELATIVE DATE
TIME SHIFT 1 HOUR
START DATE
MONTH APRIL
WEEK 1ST
DAY SUNDAY
START TIME 02:00 AM
END DATE
MONTH OCTOBER
WEEK LAST
DAY SUNDAY
END TIME 02:00 AM
BACK
EXIT
Follow the instructions in step 7 for FIXED DATE, adding WEEK.
An event is a preprogrammed camera, park, scan, preset, pattern, window blanking, alarm, or
auxiliary function that can be performed automatically at a specific date and time.
For example, suppose a camera is set to run in a continuous pattern that scans a parking lot
during business hours Monday through Friday. On Saturday and Sunday the camera needs to stop
running the pattern and observe a gate. First, program a preset to set the camera to observe the
gate. Second, schedule an event to activate the preset on the weekends. Finally, a second,
separate event must be scheduled to end the first event and allow the camera to return to the
pattern on Monday.
Note: Events do not have a selectable duration. A second event must be scheduled to end a
previous event.
Events can be programmed from the Preset, Pattern, Window Blanking, Alarm, or Aux menus, or
they can be programmed from the Event menu. Events are managed individually or as a group
from the Event menu.
*This setting applies only to Pressurized Spectra IV dome systems.
Any of the available event types can be selected from this menu, or you may select ALL EVENTS
to manage the events as a group.The following are the settings for event type:
SCAN: A scan event executes a specified scan (random, auto, or frame scan) using the limit
stops and scan speed defined in the Motion menu. Refer to Motion Settings on page 50.
PARK: A park event executes the user-defined park action as specified in the Motion menu.
Refer to Park Action on page 51.
WINDOW BLANKING: A window blanking event activates or deactivates a previously defined
window blank. The window blank remains activated or deactivated until another programmed
event changes the state of the window or you modify it through the Window Blanking menu.
Refer to Window Blanking on page 65.
AUX: An auxiliary event turns on/off an auxiliary output when the event triggers. Refer to Aux on
page 71.
ALARM: An alarm event executes the action associated with the specified alarm number. Refer
to Alarms on page 68.
PATTERN: A pattern event starts a previously defined pattern when the event is triggered. Refer
to Patterns on page 63.
CAMERA: A camera event assigns the camera settings of a preset to the current camera
settings located in the Camera menu. Refer to Camera on page 38. The preset that is referenced
by the event must be defined prior to setting up a camera event.
For the camera event to function, the referenced preset must have Custom Camera Settings
activated. Refer to Presets on page 57.
Note: If you have camera settings defined in the Camera menu that you wish to restore
following a camera event which overwrites those settings, you must save the original settings as
a separate preset prior to the camera event being triggered. You can then set a second camera
event to call the preset that has the original settings saved. Camera settings can also be changed
manually from the Camera menu following the original camera event.
PRESET: A preset event executes a previously defined preset when the event is triggered. Refer
to Presets on page 57.
Note: The event type cannot be changed if you are accessing it through the Edit Schedule option
from the Preset, Pattern, Window Blanking, Alarm, or Aux menu.
*This setting applies only to Pressurized Spectra IV dome systems.
Use the following steps to manage an existing event.
1. Use the joystick to position the cursor beside EVENT LABEL. Press Iris Open.
2. Move the joystick up or down to scroll through the events. Press Iris Open to enter selection.
As you scroll through the events, the reference information at the bottom of the screen
displays the corresponding details for each event. To view a list of all events and their
details, refer to List Event on page 84.
EVENT LABEL
After an event is programmed, the label can be changed using the following steps:
1. Use the joystick to position the cursor beside EDIT EVENT LABEL.
2. Press Iris Open. The following appears on the monitor:
EDIT EVENT LABEL
EVENT 1
1234567890 OK
ABCDEFGHIJ CANCEL
KLMNOPQRST
UVWXY.,-/ SPACE
abcdefghij BACKSPACE
klmnopqrst
uvwxyz#&:*
3. Use the joystick to position the cursor beside a character. Press Iris Open to enter the
selection. To clear a character, position the cursor beside BACKSPACE, and then press Iris
Open.
4. When the label is completed, move the cursor to OK. Press Iris Open to return to the Edit
Schedule menu.
After an event is labeled, the label will be displayed when the event is activated according to the
display setup values for this label. Refer to Display Setup on page 36 for instructions on how to
change the way a label is displayed on the monitor.
*This setting applies only to Pressurized Spectra IV dome systems.
1. Use the joystick to position the cursor beside EDIT EVENT.
2. Press Iris Open. The following appears on the monitor:
EDIT EVENT
EVENT LABEL EVENT 1
EVENT ACTIVE NO
EVENT TIME 12:00 AM
EVENT OCCURS
SUNDAY OFF
MONDAY OFF
TUESDAY OFF
WEDNESDAY OFF
THURSDAY OFF
FRIDAY OFF
SATURDAY OFF
HOLIDAY SKIP HOLIDAYS
EVENT TYPE PRESET
NUMBER 1
BACK
EXIT
a. Use the joystick to position the cursor beside EVENT ACTIVE. Press Iris Open. Scroll
to select NO to leave the event inactive or YES to activate the event. Press Iris Open to
confirm your selection.
b. Use the joystick to position the cursor beside EVENT TIME. Press Iris Open. Scroll
through the hours until the desired time appears. Use the joystick to move the cursor
to the right. Scroll through the minutes until the desired time appears. Press Iris Open
to select the time.
c. Use the joystick to position the cursor beside SUNDAY. Press Iris Open. The available
options are OFF and ON. Press Iris Open to confirm your selection.
d. Follow the instructions in the previous step for the remaining days of the week.
e. Use the joystick to position the cursor beside HOLIDAY. Press Iris Open. The following
are the holiday settings:
SKIP HOLIDAYS: The event will not occur on a day of the week for which it is set if
that date is in the list of holidays.
ON: The event will activate on holidays that are set in the Event menu, in addition to
its normally scheduled days of the week.
OFF: The event only occurs on the days of the week that it is scheduled; holidays have
no effect on the event.
*This setting applies only to Pressurized Spectra IV dome systems.
1. Use the joystick to position the cursor beside CLEAR EVENT.
2. Press Iris Open.
3. Follow the directions displayed on the monitor.
LIST EVENT
To list events:
1. Use the joystick to position the cursor beside LIST EVENT.
2. Press Iris Open.
3. All programmed events will be listed.
HOLIDAY
Use the following steps to create a new holiday.
1. Use the joystick to position the cursor beside HOLIDAY. Press Iris Open.
2. Move the joystick up or down to scroll through the options. If no holidays were created in
the past, NEW is the only selectable option. Press Iris Open to select NEW.
3. Proceed to Edit Holiday on page 85.
Use the following steps to manage an existing holiday.
1. Use the joystick to position the cursor beside HOLIDAY. Press Iris Open.
2. Move the joystick up or down to scroll through the holidays. Press Iris Open to enter a
selection.
3. Proceed to Edit Holiday on page 85.
Note: Holidays cannot be changed through the Edit Schedule option from the Preset, Pattern,
Window Blanking, Alarm, or Aux menus.
*This setting applies only to Pressurized Spectra IV dome systems.
Use this function to reset all camera settings to factory default parameters.
CYCLE CAMERA POWER
If the camera is not operating or if you lose camera control, cycle camera power. Cycling camera
power resets the camera but does not change any saved camera settings.
REBOOT SYSTEM
Reboot the system if it is not operating or if there is no control. Rebooting the system will cycle
dome and camera power without changing programmed dome settings.
88C3412M-D (12/08)
Page 88
Software/Language File Upload
The RJ-45 data port of the dome drive allows access for on-site setup, testing, and uploading of revised operating
software and language files. A Pelco field service tool is required to perform these operations. Field service tools include
Pelco’s remote monitor kit (IPS-RMK), remote data port box (IPS-RDPE-2), and remote monitor cable (IPS-CABLE).
For instructions on how to upload revised operating software and language files refer to the Installation/Operation manual
supplied with the field service tool.
Note: Only perform software uploads when necessary. Software uploads do not need to be performed if the dome system
is operating properly.
During a software/language file upload, a progress bar will appear on the monitor to indicate data is being transferred to
the Spectra dome system. The default setting for data transmission is 115.2 KB per second. Noisy and long-run
connections will slow the transmission rate.
C3412M-D (12/08)89
Page 89
Suggested Preventative Maintenance
The Spectra IV and Spectra IV SE dome systems do not require any special maintenance.
Occasionally, dust may build up on the inside or the outside of the dome. If this occurs, turn power off to the unit and
remove the lower dome from the back box. Remove the dust from the lower dome using compressed air from a spray can.
Replace the lower dome following the installation instructions that were shipped with it.
Warning: Proper eye protection should be worn when using compressed air cans.
90C3412M-D (12/08)
Page 90
Specifications
16X MODELS
DD4TC16
Signal FormatNTSC
Scanning System2:1 Interlace
Image Sensor1/4-inch interline transfer CCD
Effective Pixels768 (H) X 494 (V)
Horizontal Resolution>470 TV lines
Lensf/1.4 (focal length, 4~64 mm; 16X optical zoom, 8X digital zoom)
Zoom Speed (optical range)1.9/3.6/6.0 seconds
Horizontal Angle of View43° at 4 mm wide zoom; 3° at 64 mm telephoto zoom
FocusAutomatic with manual override
Maximum Sensitivity at 35 IRE0.05 lux at 1/2 sec. shutter speed (color)
Sync SystemAC line lock, phase adjustable using remote control, V-Sync
Shutter Speed Automatic (electronic iris)/manual; 1/2 ~ 1/30,000
Iris ControlAutomatic iris control with manual override
Gain ControlAutomatic with manual override
Video Output1 Vp-p, 75 ohms
Video Signal-to-Noise>50 dB
DD4TC16-X
Signal FormatPAL
Scanning System2:1 Interlace
Image Sensor1/4-inch interline transfer CCD
Effective Pixels752 (H) X 582 (V)
Horizontal Resolution>460 TV lines
Lensf/1.4 (focal length, 4~64 mm; 16X optical zoom, 8X digital zoom)
Zoom Speed (optical range)1.9/3.6/6.0 seconds
Horizontal Angle of View43° at 4 mm wide zoom; 3° at 64 mm telephoto zoom
FocusAutomatic with manual override
Maximum Sensitivity at 35 IRE0.05 lux at 1/1.5 sec. shutter speed (color)
Sync SystemAC line lock, phase adjustable using remote control, V-Sync
Shutter SpeedAutomatic (electronic iris)/manual; 1/1.5~1/30,000
Iris ControlAutomatic iris control with manual override
Gain ControlAutomatic with manual override
Video Output1 Vp-p, 75 ohms
Video Signal-to-Noise>50 dB
C3412M-D (12/08)91
Page 91
18X MODELS
DD4CBW18
Signal Format NTSC
Scanning System 2:1 Interlace
Image Sensor 1/4-inch progressive scan CCD
Effective Pixels 768 (H) X 494 (V)
Horizontal Resolution 540 TV lines
Lens f/1.6 (focal length, 3.8~68.4 mm; 18X optical zoom, 12X digital zoom)
Zoom Speed (optical range) 2.9/4.2/5.8 seconds
Horizontal Angle of View 51° at 3.8 mm wide zoom; 3° at 68.4 mm telephoto zoom
Focus Automatic with manual override
Maximum Sensitivity at 35 IRE 0.025 lux at 1/2 sec. shutter speed (color)
Sync System Internal/AC line lock, phase adjustable using remote control, V-Sync
White Balance Automatic with manual override
Shutter Speed Automatic (electronic iris)/manual; 1/2~1/30,000
Iris Control Automatic iris control with manual override
Gain Control Automatic/off
Video Output 1 Vp-p, 75 ohms
Video Signal-to-Noise >50 dB
DD4CBW18-X
Signal Format PAL
Scanning System 2:1 Interlace
Image Sensor 1/4-inch progressive scan CCD
Effective Pixels 752 (H) X 582 (V)
Horizontal Resolution 540 TV lines
Lens f/1.6 (focal length, 3.8~68.4 mm; 18X optical zoom, 12X digital zoom)
Zoom Speed (optical range) 2.9/4.2/5.8 seconds
Horizontal Angle of View 51° at 3.8 mm wide zoom; 3° at 68.4 mm telephoto zoom
FocusAutomatic with manual override
Maximum Sensitivity at 35 IRE 0.025 lux at 1/1.5 sec. shutter speed (color)
Sync System Internal/AC line lock, phase adjustable using remote control, V-Sync
White Balance Automatic with manual override
Shutter Speed Automatic (electronic iris)/manual; 1/1.5~1/30,000
Iris Control Automatic iris control with manual override
Gain Control Automatic/off
Video Output 1 Vp-p, 75 ohms
Video Signal-to-Noise >50 dB
0.1 lux at 1/60 sec. shutter speed (B-W)
0.004 lux at 1/2 sec. shutter speed (B-W)
0.1 lux at 1/50 sec. shutter speed (B-W)
0.004 lux at 1/1.5 sec. shutter speed (B-W)
92C3412M-D (12/08)
Page 92
22X MODELS
DD4C22
Signal FormatNTSC
Scanning System2:1 Interlace
Image Sensor1/4-inch CCD
Effective Pixels768 (H) X 494 (V)
Horizontal Resolution>470 TV lines
Lensf/1.6 (focal length, 4~88 mm; 22X optical zoom, 12X digital zoom)
Zoom Speed (optical range)2.4/3.9/6.3 seconds
Horizontal Angle of View47° at 4 mm wide zoom; 2.2° at 88 mm telephoto zoom
FocusAutomatic with manual override
Maximum Sensitivity at 35 IRE0.02 lux at 1/2 sec. shutter speed
Sync SystemInternal/AC line lock, phase adjustable using remote control, V-Sync
White BalanceAutomatic with manual override
Shutter Speed Automatic (electronic iris)/manual; 1/2~1/30,000
Iris ControlAutomatic iris control with manual override
Gain ControlAutomatic/off
Video Output1 Vp-p, 75 ohms
Video Signal-to-Noise>50 dB
DD4C22-X
Signal FormatPAL
Scanning System2:1 Interlace
Image Sensor1/4-inch CCD
Effective Pixels752 (H) X 582 (V)
Horizontal Resolution>460 TV lines
Lensf/1.6 (focal length, 4~88 mm; 22X optical zoom, 12X digital zoom)
Zoom Speed (optical range)2.4/3.9/6.3 seconds
Horizontal Angle of View47° at 4 mm wide zoom; 2.2° at 88 mm telephoto zoom
FocusAutomatic with manual override
Maximum Sensitivity at 35 IRE0.02 lux at 1/1.5 sec. shutter speed
Sync SystemInternal/AC line lock, phase adjustable using remote control, V-Sync
White BalanceAutomatic with manual override
Shutter SpeedAutomatic (electronic iris)/manual; 1/1.5~1/30,000
Iris ControlAutomatic iris control with manual override
Gain ControlAutomatic/off
Video Output1 Vp-p, 75 ohms
Video Signal-to-Noise>50 dB
C3412M-D (12/08)93
Page 93
23X MODELS
DD4CBW23
Signal FormatNTSC
Scanning System2:1 Interlace
Image Sensor1/4-inch progressive scan CCD
Effective Pixels768 (H) X 494 (V)
Horizontal Resolution540 TV lines
Lensf/1.6 (focal length, 3.6~82.8 mm; 23X optical zoom, 12X digital zoom)
Zoom Speed (optical range)2.9/4.2/5.8 seconds
Horizontal Angle of View54° at 3.6 mm wide zoom; 2.5° at 82.8 mm telephoto zoom
FocusAutomatic with manual override
Maximum Sensitivity at 35 IRE0.025 lux at 1/2 sec. shutter speed (color)
Sync SystemInternal/AC line lock, phase adjustable using remote control, V-Sync
White BalanceAutomatic with manual override
Shutter Speed Automatic (electronic iris)/manual; 1/2~1/30,000
Iris ControlAutomatic iris control with manual override
Gain ControlAutomatic/off
Video Output1 Vp-p, 75 ohms
Video Signal-to-Noise>50 dB
Wide Dynamic Range80X
0.1 lux at 1/60 sec. shutter speed (B-W)
0.004 lux at 1/2 sec. shutter speed (B-W)
94C3412M-D (12/08)
Page 94
DD4CBW23-X
Signal FormatPAL
Scanning System2:1 Interlace
Image Sensor1/4-inch progressive scan CCD
Effective Pixels752 (H) X 582 (V)
Horizontal Resolution540 TV lines
Lensf/1.6 (focal length, 3.6~82.8 mm; 23X optical zoom, 12X digital zoom)
Zoom Speed2.9/4.2/5.8 seconds
Horizontal Angle of View54° at 3.6 mm wide zoom; 2.5° at 82.8 mm telephoto zoom
FocusAutomatic with manual override
Maximum Sensitivity at 35 IRE0.025 lux at 1/1.5 sec. shutter speed (color)
0.1 lux at 1/50 sec. shutter speed (B-W)
0.004 lux at 1/1.5 sec. shutter speed (B-W)
Sync SystemInternal/AC line lock, phase adjustable using remote control, V-Sync
White BalanceAutomatic with manual override
Shutter SpeedAutomatic (electronic iris)/manual; 1/1.5~1/30,000
Iris ControlAutomatic iris control with manual override
Gain ControlAutomatic/off
Video Output1 Vp-p, 75 ohms
Video Signal-to-Noise>50 dB
Wide Dynamic Range80X
C3412M-D (12/08)95
Page 95
35X MODELS
DD4CBW35
Signal FormatNTSC
Scanning System2:1 Interlace/1:1 Progressive (user-selectable)
Image Sensor1/4-inch CCD
Effective Pixels768 (H) X 494 (V)
Horizontal Resolution>540 TV lines
Lensf/1.4 (focal length, 3.4~119 mm; 35X optical zoom, 12X digital zoom)
Zoom Speed (optical range)3.2/4.6/6.6 seconds
Horizontal Angle of View55.8° at 3.4 mm wide zoom; 1.7° at 119 mm telephoto zoom
FocusAutomatic with manual override
Maximum Sensitivity at 35 IRE0.55 lux at 1/60 sec. shutter speed (color)
Sync SystemInternal/AC line lock, phase adjustable using remote control, V-Sync
White BalanceAutomatic with manual override
Shutter Speed Automatic (electronic iris)/manual; 1/2~1/30,000
Iris ControlAutomatic iris control with manual override
Gain ControlAutomatic/off
Video Output1 Vp-p, 75 ohms
Video Signal-to-Noise>46–50 dB
Wide Dynamic Range128X
0.063 lux at 1/4 sec. shutter speed (color)
0.00018 lux at 1/2 sec. shutter speed (B-W)
96C3412M-D (12/08)
Page 96
DD4CBW35-X
Signal FormatPAL
Scanning System2:1 Interlace/1:1 Progressive (user-selectable)
Image Sensor1/4-inch CCD
Effective Pixels752 (H) X 582 (V)
Horizontal Resolution>540 TV lines
Lensf/1.4 (focal length, 3.4~119 mm; 35X optical zoom, 12X digital zoom)
Zoom Speed3.2/4.6/6.6 seconds
Horizontal Angle of View55.8° at 3.4 mm wide zoom; 1.7° at 119 mm telephoto zoom
FocusAutomatic with manual override
Maximum Sensitivity at 35 IRE0.50 lux at 1/50 sec. shutter speed (color)
0.062 lux at 1/3 sec. shutter speed (color)
0.00014 lux at 1/1.5 sec. shutter speed (B-W)
Sync SystemInternal/AC line lock, phase adjustable using remote control, V-Sync
White BalanceAutomatic with manual override
Shutter SpeedAutomatic (electronic iris)/manual; 1/1.5~1/30,000
Iris ControlAutomatic iris control with manual override
Gain ControlAutomatic/off
Video Output1 Vp-p, 75 ohms
Video Signal-to-Noise>46–50 dB
Wide Dynamic Range128X
The materials used in the manufacture of this document and its components are compliant to the requirements of Directive 2002/95/EC.
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the
European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures
for recycling this equipment.
C3412M-D (12/08)97
Page 97
Page 98
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in
material or workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
• Five years:
– Fiber optic products
– TW3000 Series unshielded twisted pair (UTP) transmission products
– CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and
MC3651H-2X camera models
• Three years:
– Pelco-branded fixed camera models (CCC1390H Series, C10DN Series,
C10CH Series, and IP3701H Series)
– EH1500 Series enclosures
®
– Spectra
– Camclosure
– DX Series digital video recorders, DVR5100 Series digital video
– Endura
– Genex
– PMCL200/300/400 Series LCD monitors
• Two years:
– Standard motorized or fixed focal length lenses
– DF5/DF8 Series fixed dome products
– Legacy
– Spectra III
– Esprit Ti and TI2500 Series thermal imaging products
– Esprit and WW5700 Series window wiper (excluding wiper blades).
– CM6700/CM6800/CM9700 Series matrix
– Digital Light Processing (DLP
– Intelli-M
• One year:
– Video cassette recorders (VCRs), except video heads. Video heads will
• Six months:
– All pan and tilts, scanners, or preset lenses used in continuous motion
IV products (including Spectra IV IP)
®
Series (IS, ICS, IP) integrated camera systems
®
recorders, Digital Sentry
video recorders, and NVR300 Series network video recorders
®
Series distributed network-based video products
®
Series products (multiplexers, server, and keyboard)
®
Series integrated positioning systems
™
, Spectra Mini, Spectra Mini IP, Esprit®, ExSite®, and PS20
scanners, including when used in continuous motion applications.
The lamp and color wheel will be covered for a period of 90 days. The
air filter is not covered under warranty.
®
eIDC controllers
Series hardware products, DVX Series digital
®
) displays (except lamp and color wheel).
be covered for a period of six months.
applications (preset scan, tour, and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of
Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid
to a Pelco designated location. Repairs made necessary by reason of misuse,
alteration, normal wear, or accident are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss
resulting from the specific use or application made of the Products. Pelco’s
liability for any claim, whether based on breach of contract, negligence,
infringement of any rights of any party or product liability, relating to the
Products shall not exceed the price paid by the Dealer to Pelco for such
Products. In no event will Pelco be liable for any special, incidental, or
consequential damages (including loss of use, loss of profit, and claims of third
parties) however caused, whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer
may also have additional rights, which are subject to variation from state to
state.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100
or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the
following information:
1. Model and serial number
2. Date of shipment, P.O. number, sales order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product that does not fall
under the warranty conditions stated above, please include a written
explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by which
the item was received by Pelco.
RETURNS
To expedite parts returned for repair or credit, please call Pelco at (800) 289-9100
or (559) 292-1981 to obtain an authorization number (CA number if returned for
credit, and RA number if returned for repair) and designated return location.
All merchandise returned for credit may be subject to a 20 percent restocking
and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the
assigned CA or RA number and freight should be prepaid
11-11-08
REVISION HISTORY
Manual #DateComments
C3412M9/06Original version.
C3412M-A10/06Upgraded 23X to Spectra IV SE and added 18X information. Corrected specifications. Revised SW2 Switches 4–5 section.
C3412M-B6/07Corrected menus and Specifications. Added cross references. Added information about low light focus, event labels, and image
C3412M-C11/07Updated manual to reflect software version 1.070. Added DIP switch and progressive scan sections. Revised switch settings, type of
C3412M-D12/08Updated to reflect software version 1.090. Added new sections for sure focus, event types, low lux noise reduction, sensor scan mode,
lighting, IR cut filter, and proportional pan settings.
and field align. Revised information regarding SW2-3, type of lighting settings, 18X and 23X specifications, auto white balance defaults,
and limitations to presets. Removed all references to 22X black-white models.
Page 99
www.pelco.com
Pelco, Inc. Worldwide Headquarters 3500 Pelco Way Clovis, California 93612 USA
USA & Canada Tel (800) 289-9100 Fax (800) 289-9150
International Tel +1 (559) 292-1981 Fax +1 (559) 348-1120
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.