Pelco REL2064 Specsheet

PRODUCT SPECIFICATION
19.00 (48.26)
PWR
ALARM
REL2064
Relay Interface Unit
Made in USA
17.40 (44.20)
1.75
(4.45)
8.15
(20.70)
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES
REL2064 Relay Interface Unit
CONTROLS UP TO 64 RELAY CONTACT OUTPUTS
analog systems and controls
64 SPST Dry Contact Outputs
Provides Direct or Automatic Control of Peripheral Equipment
Connect to the CM6800 Series Matrix Switchers Using Pelco M
Protocol
Uses RS-485 Communication Interface
Multiple Units May Be Cascaded to Provide Multiple Relay Contact
Points on a Single M-Port Connection
Relay Output Contacts May Be Configured for Normally Open (N.O.)
or Normally Closed (N.C.) Operation
Relay Groups Can Retain Their Contact Position in the Event of a
Power Failure or Front Panel Reset
Powered by an Autoranging Power Supply
The REL2064 relay interface unit connects directly to the System 6800 matrix switcher/controller and provides dry contacts for direct or automatic control of peripheral equipment. Each REL2064 provides up to 64 single-pole, single-throw (SPST) dry contact outputs.
Using Pelco’s proprietary M protocol, the relay interface unit communicates with Pelco’s CM6800 matrix switcher using an RS-485 communication interface.
Up to four relay interface units may be cascaded to provide multiple relay contact points on a single CM6800 M-port connection.
Relay output contacts may be configured for normally open (N.O.) or normally closed (N.C.) operation.
The REL2064 provides a memory feature, which allows relay groups to retain their contact position in the event of a power failure or front panel reset.
The relay interface unit is powered by an autoranging power supply.
The REL2064 occupies one rack unit (1.75 inches or 4.45 cm), accommodating multiple types of mounting.
International Standards
Organization Registered Firm;
ISO 9001 Quality System
C1518 / REVISED 3-21-11
TECHNICAL SPECIFICATIONS
Pelco, the Pelco logo, and other tradema rks associated with Pelco products referred
to in this publication are trademarks of Pelco, Inc. or its affiliates. All other
product names and services are the p roperty of their respective companies.
Product specifications and availability are subject to change without notice.
©Copyright 2011, Pelco, Inc. All rights reserved.
MODEL
REL2064 Relay interface unit; provides 64 relays for
ELECTRICAL
Input Voltage 100 to 240 VAC, 50/60 Hz, autoranging Power Consumption 30 VA (reactive consumption); 5 W (active)
Data Ports
Input RS-485, RJ-45 connector;
Output RS-485, RJ-45 connector:
Indicators 2 power LEDs, green;
Fusing 500 mA, 250 V
Relay Output
Contact Parameters
Max. Switching Capacity 60 W Max. Operating Voltage 125 VAC, 50/60 Hz Max. Current 2 A Contact Resistance 75 milliohms
Rated Load Parameters 0.5 A at 125 VAC, 50/60 Hz
Operating Distance 4,000 feet (1,219 m) on 24 AWG wire
operating peripheral equipment.
baud rate selected with DIP switch
baud rate selected with DIP switch
1 data LED, red
2 A at 30 VDC
MECHANICAL
Connectors
Relay Inputs 4 dual-header, 32-input connectors with
Power 3-wire, 18 AWG RS-485 Two RJ-45 connectors Relay Out One 3-pin header with mating plug
mating plugs
GENERAL
Ambient Operating Temperature 32° to 122°F (0° to 50°C) Dimensions 8.15" D x 17.40" W x 1.75" H
Mounting Fits 19-inch EIA Standard rack (1 RU) Unit Weight 8 lb (3.63 kg) Shipping Weight 12 lb (5.4 kg)
(20.70 x 44.20 x 4.45 cm)
CERTIFICATIONS/RATINGS
• CE, Class B
• FCC, Class B
• UL/cUL Listed
•C-Tick
Pelco by Schneider Electric
3500 Pelco Way, Clovis, California 93612-5699 United States
USA & Canada Tel (800) 289-9100 Fax (800) 289-9150 International Tel +1 (559) 292-1981 Fax +1 (559) 348-1120 www.pelco.com