PRODUCT SPECIFICATION
camera solutions
PT1260EX Pan/Tilt
EXPLOSIONPROOF
Product Features
• Meets NEMA Type 4X Standards
• 120 or 230 VAC Operation
• Rugged Construction
• For Use in a Variety of Harsh and Hazardous Environments
• Heavy Duty Adjustable Worm-Gear Final Drive
• Optional Preset Positioning Capability
• Limit Stops Internally Adjustable
• Indoor/Outdoor Applications
• Maximum Load 100 Pounds (45.4 kg)
The
PT1260EX
requirements of explosionproof and dust-ignition-proof electrical
equipment installed in Class I (Group C and D) and Class II, (Group E,
F, and G) hazardous locations.
Easily capable of handling loads up to 100 pounds (45.4 kg), the
PT1260EX
explosion-proof enclosure for potentially hazardous or combustible
applications.
The
PT1260EX
worm-gear final drives to ensure long operational life, as well as
drift-free operation.
pan/tilt has been engineered to meet the rigorous
is ideally suited for use with our EHX*E Series
features rugged, high torque AC motors and adjustable
6.25
(15.88)
2.50
(6.35)
7.00
(17.78)
14.06
(35.71)
14.50
(36.83)
Ø3.75 (0.95) 4X
0.656 X 0.281 OB 2X
(1.67 X 0.71)
Ø 0.281 (0.71) 5X
2.37
(6.02)
7.25
(18.42)
The
PT1260EX
is manufactured from anodized plate aluminum. All
internal and external parts are constructed of corrosion-protected
steel or aluminum, and the fasteners are stainless steel. Pan and tilt
limit stops are internally adjustable.
16.50
(41.91)
11.00
(27.94)
TO CL TILT
9.00
(22.86)
0.375 (0.95) 4X
EQ SP ON 7.00 (17.78) B.C.
0.375 (0.95) 4X
EQ SP ON 7.25 (18.42) B.C.
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES.
International Standards
Organization Registered Firm;
ISO 9001 Quality System
C368 / REVISED 3-29-11
TECHNICAL SPECIFICATIONS
MODELS
PT1260EX Explosionproof/weatherproof pan/tilt,
PT1260EX/220 Same as PT1260EX except 230 VAC operation
PT1260EX/PP Same as PT1260EX except has preset option;
PT1260EX/PP/230 Same as PT1260EX/PP except 230 VAC
120 VAC
requires preset control
operation
ELECTRICAL
Input Voltage
PT1260EX, PT1260EX/PP 120 VAC, 50/60 Hz
PT1260EX/220,
PT1260EX/PP/230 230 VAC, 50/60 Hz
Power Requirements
PT1260EX, PT1260EX/PP Pan Tilt
Running 0.48 A (57.5 VA) 0.48 A (57.5 VA)
Starting 0.60 A (72.5 VA) 0.60 A (72.5 VA)
PT1260EX/220,
PT1260EX/PP/230 Pan Tilt
Running 0.19 A (43.7 VA) 0.27 A (62.1 VA)
Starting 0.19 A (43.7 VA) 0.27 A (62.1 VA)
Connectors Explosionproof gland (supplied)
Motors Two-phase induction type, instantaneous
Limit Switches 5 A each (pan and tilt); internal adjustment
Conductor Requirements 6, unshielded (functions: left, right, up, down,
Maximum Operating Distances*
PT1260EX and PT1260EX/PP
6 Conductors Cable Size Maximum Distance
PT1260EX/220 and
PT1260EX/PP/230
6 Conductors 20 AWG (0.5mm2) 2,463 ft (750 m)
*Distances are calculated with both motors (pan and tilt) running and
assuming a 10% voltage drop.
reversing
motor common, safety ground); PP option
requires 4 additional conductors
2
20 AWG (0.5mm
18 AWG (1.0mm2) 778 ft (237 m)
16 AWG (1.5mm2) 1,235 ft (376 m)
18 AWG (1.0mm2) 3,918 ft (1,194 m)
16 AWG (1.5mm2) 6,218 ft (1,895 m)
) 489 ft (149 m)
MECHANICAL
Pan 0° to 355° movement in horizontal plane
Speed 6°/sec ±1°
Torque 50 ft-lb with specified voltage
Tilt ±90° movement in vertical plane
Speed 3°/sec ±0.5°
Torque 100 ft-lb with specified voltage
Maximum Load 100 lb (45.4 kg) at 5" (12.7 cm) from tilt table
surface to center of gravity
Gearing Adjustable worm-gear final drive to prevent
drift and minimize backlash
Bearings
Pan Sealed, heavy-duty ball bearings
Tilt Oilite bronze bushing
Braking Mechanical
Duty Cycle 50% duty cycle; 30 minute rating
GENERAL
Construction Anodized, aluminum plate; all internal and
external parts corrosion protected; stainless
steel fasteners
Tilt Shaft Type 316 stainless steel
Finish Gray polyester powder coat
Environment Indoor/outdoor operation
Temperature –10° to 120°F (–23° to 49°C)
Unit Weight 69 lb (31.2 kg)
Shipping Weight 75 lb (34 kg)
CERTIFICATIONS/RATINGS
• UL Listed (PT1260EX and PT1260EX/PP)
• For use in Class I (Groups C and D) and Class II (Groups E, F, and G)
hazardous locations (PT1260EX and PT1260 EX/PP)
• Meets NEMA Type 4X standards
RECOMMENDED CONTROLS
Coaxitron® or Matrix See individual specification sheets for
information. Preset pan/tilt must be used with
Coaxitron or matrix control with PP capability
and preset receiver.
MPTAZ Series Desktop pan/tilt and zoom lens control with
auto/random scan for 120/230/24 VAC
pan/tilts.
Pelco by Schneider Electric
3500 Pelco Way, Clovis, California 93612-5699 United States
USA & Canada
International
www.pelco.com
Tel (800) 289-9100 Fax (800) 289-9150
Tel +1 (559) 292-1981 Fax +1 (559) 348-1120
RECOMMENDED ENCLOSURES
EHX*E Series Explosionproof enclosure
Pelco, the Pelco logo, and other trademarks associated with Pelco products referred
to in this publication are trademarks of Pelco, Inc. or its affiliates. All other
product names and services are the property of their respective companies.
Product specifications and availability are subject to change without notice.
©Copyright 2011, Pelco, Inc. All rights reserved.