PMCS15A, PMCS17A, and PMCS19A
Super-High Resolution Color Monitors
C1991M-C (9/04)
Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 USA • www.pelco.com
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150
International Customers: Tel +1 (559) 292-1981 or FAX +1 (559) 348-1120
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus
(including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two
blades with one wider than the other. A grounding plug has two blades and a third grounding prong.
The wide blade or the third prong are provided for your safety. If the provided plug does not fit into
your outlet consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience
receptacles, and the points where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the
apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid
injury from tip-over.
13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been
damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or
objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does
not operate normally, or has been dropped.
14. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such
as vases shall be placed on the apparatus.
15. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or
moisture.
16. Installation should be done only by qualified personnel and conform to all local codes.
17. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is
designed for indoor use only and it must not be installed where exposed to rain and moisture.
18. Use only installation methods and materials capable of supporting four times the maximum specified
load.
19. Only use replacement parts recommended by Pelco.
20. A CCC-approved power cord must be used to power this equipment when used in China.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a
risk of electric shock is present within this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
[ 2 ] Pelco Manual C1991M-C (9/04)
REGULATORY NOTICES
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However there is no guarantee that the interference will not occur
in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected.
• Consult the dealer or an experienced radio/TV technician for help.
You may also find helpful the following booklet, prepared by the FCC: “How to Identify and Resolve
Radio-TV Interference Problems.” This booklet is available from the U.S. Government Printing Office,
Washington D.C. 20402.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment
can void your authority to operate this equipment under Federal Communications Commission’s rules.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
DESCRIPTION
The PMCS15A, PMCS17A, and PMCS19A are super-high resolution color monitors. All monitors have
computer-grade picture tubes. The PMCS15A and PMCS17A produce horizontal resolution of 700 TV
lines and PMCS19A produces 800 TV lines. Standard high resolution monitors produce only about 350
TV lines.
The monitors automatically detect the power supply input (90-260 VAC, 50/60 Hz).
Models
PMCS15ASuper-high resolution color monitor, 15-inch (38.10 cm)
PMCS17ASuper-high resolution color monitor, 17-inch (43.18 cm)
PMCS19ASuper-high resolution color monitor, 19-inch (48.26 cm)
Pelco Manual C1991M-C (9/04) [ 3 ]
INSTALLATION
The monitor may be placed on any flat surface (desk or table) or rack-mounted. To rack-mount the
monitor follow the instructions supplied with the rack mount kit.
Video and Power Connections
1. Video Cable Connection (Refer to Table A for video coaxial cable requirements.)
a. Connect the video cable to the BNC video input labeled V1 IN on the back panel of the monitor.
If the installation requires a second video input, connect a video cable to the BNC video input labeled V2 IN.
b. Looping Operation Only - Connect a video cable to the BNC connector labeled V1 OUT. If the in-
stallation requires a second video output, connect a video cable to the BNC video output labeled
V2 OUT. Refer to Figures 2 and 3.
2. Impedance Switch Setting
a. Terminating Operation Only - Set the termination switch to 75Ω position.
b. Looping Operation Only - Set the impedance switch to the V1-HI and V2-HI positions. Refer to
Figures 2 and 3.
3. Plug the power cord (provided) into the AC INLET connection on the back panel. Plug the other end
of the cord into a power receptacle.
FRONT
VOLUME SHARP BRIGHTCONT . COLORTINT
BAC K
V1-H I
75
V2-H I
75
AC INLET
V2 IN
V1 INAU1 IN
V2 OUT
V1 OUT
AU1 OUT
AU1 AU2
VIDEO 1 VIDEO 2 S-VIDEO
AU2 IN
Y/C-HI
75
AU2 OUT
S-VIDEO IN
S-VIDEO OUT
Figure 1. Models PMCS15A, PMCS17A, and PMCS19A Color Monitors, Front and Back Panels
[ 4 ] Pelco Manual C1991M-C (9/04)
Table A. Video Coaxial Cable Requirements
Cable Type*Maximum Distance
RG59/U750 ft (229 m)
RG6/U1,000 ft (305 m)
RG11/U1,500 ft (457 m)
* Minimum cable requirements:
75 ohms impedance
All-copper center conductor
All-copper braided shield with 95% braid coverage
V1-H
CAMERACAMERA
V1-L
V1 INAU1 IN
V2-H
V2-L
V1OUT
V2 IN
AU1 OU T
V2OUT
AU2 OUT
S-VHS IN
AU2 IN
S-HI
S-LO
S-VHS OU T
VCRVCR
Figure 2. Looping Operation - One Monitor with External Video Equipment
V1-H
V1-L
V1 INAU1 IN
V2-H
V2-L
V1OU T
CAMERA
V2 IN
AU2 IN
S-HI
AU1 OUT
AU2 OUT
S-LO
V2 OUT
S-VHS IN
S-VHS OUT
V1-H
V1-L
V1 INAU1 IN
V2-H
V2-L
V1OUT
V1-H
V1-L
AU2 OUT
S-VHS IN
AU2 IN
S-HI
S-LO
S-VHS OUT
V1 INAU1 IN
V2-H
V2-L
V1OUT
V2 IN
AU2 IN
V2 OUT
AU1 OUT
AU2 OUT
V2 IN
V2 OUT
AU1 OUT
VCR
Figure 3. Looping Operation - Maximum of Three Monitors with External Video Equipment
Pelco Manual C1991M-C (9/04) [ 5 ]
S-VHS IN
S-HI
S-LO
S-VHS OUT
OPERATION
1. Set the video format switch located on the front panel to one of the following settings:
VIDEO1 - Composite video (NTSC/PAL) mode
VIDEO2 - Composite video (NTSC/PAL) mode for two, video input operation
S-VIDEO - S-VHS mode if the S-VHS input jack on the back of the monitor is used
2. If required adjust the picture using the control knobs on the front panel.
Front Panel Adjustments
TINTColor phase adjustment. Turn clockwise to increase the greenish tones in the picture.
Turn counterclockwise to increase the reddish tones in the picture.
COLORColor saturation level. Turn the control knob clockwise to increase the saturation level
CONTContrast adjustment. Proper adjustment will allow maximum gradations between the
BRIGHT Brightness display adjustment. Turn the control clockwise to increase brightness and
SHARPSharpness adjustment. Adjust control knob to obtain the clearest picture.
VOLUME Audio adjustment. Turn the control clockwise to increase volume and counterclockwise
and counterclockwise to decrease the saturation level.
darkest and lightest picture contrast. Turn the control clockwise to increase picture contrast and counterclockwise to decrease contrast.
counterclockwise to decrease brightness.
to decrease volume.
MAINTENANCE
If the quality of the picture is poor and cannot be improved by making adjustments on the front control
panel, inspect all system connections and cable runs.
To reduce the risk of electrical shock, do not remove the cover or back of monitor. No user-serviceable
parts are inside. Refer servicing to qualified personnel, or contact the Pelco Customer Service Department for assistance. Refer to the Warranty and Return Information section.
[ 6 ] Pelco Manual C1991M-C (9/04)
SPECIFICATIONS
ELECTRICAL
Input Voltage90-260 VAC, 50/60 Hz, autoranging
Power Consumption
ConstructionSteel cabinet
FinishBlack with black bezel around screen
Dimensions
PMCS15A14.0 (W) x 12.9 (H) x 15.0 (D) inches
PMCS17A16.0 (W) x 14.5 (H) x 16.0 (D) inches
PMCS19A17.4 (W) x 16.4 (H) x 17.5 (D) inches
Weight
PMCS15A35 lb (15.8 kg)
PMCS17A43 lb (19.5 kg)
PMCS19A53 lb (24.0 kg)
2 looping outputs
2 looping outputs
1 looping output
(35.6 x 32.7 x 38.1 cm)
(40.6 x 36.9 x 40.6 cm)
(44.0 x 41.5 x 44.5 cm)
ENVIRONMENTAL
Operating Temperature32° to 106°F (0° to 41°C)
Humidity0% to 90% (noncondensing)
This equipment contains electrical or electronic components that must be recycled
properly to comply with Directive 2002/96/EC of the European Union regarding the
disposal of waste electrical and electronic equipment (WEEE). Contact your local
dealer for procedures for recycling this equipment.
(Design and product specifications subject to change without notice.)
Pelco Manual C1991M-C (9/04) [ 7 ]
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of
shipment.
Exceptions to this warranty are as noted below:
• Five years on FT/FR8000 Series fiber optic products.
• Three years on Genex
• Three years on Camclosure® and fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and
MC3651H-2X camera models, which have a five-year warranty.
•Two years on standard motorized or fixed focal length lenses.
•Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products.
•Two years on Spectra
•Two years on Esprit® and WW5700 Series window wiper (excluding wiper blades).
• Eighteen months on DX Series digital video recorders, NVR300 Series network video recorders, and Endura™ Series distributed network-based video
products.
• One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.
• Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight
prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this
warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s
liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products
shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential
damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state
to state.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and
provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written
explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization
number (CA number if returned for credit, and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate
address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the
following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
REVISION HISTORY
Manual #DateComments
C1991M11/00Original version.
C1991M-A01/01Added ETL and cETL certifications.
C1991M-B2/01Added information on model PMCS19A.
C1991M-C9/04Added information on model PMCS15A. Deleted model PMCS14A. Revised unit weights.
®
Series products (multiplexers, server, and keyboard).
®
, Esprit®, ExSite™, and PS20 scanners, including when used in continuous motion applications.
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors
473 Eccles Avenue
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco.