Pelco MR5000 User Manual

®
Installation/Operation
ICS-DO101ABK Integrated Camera System for the MR5000 Series Public View System
C2436M-B (9/02)
Pelco
• 3500 Pelco Way • Clovis, CA 93612-5699 USA •
In North America and Canada:
International Customers:
Tel (800) 289-9100 • FAX (800) 289-9150
Tel +1(559) 292-1981 • FAX +1(559) 348-1120
'
[ 2 ] Pelco Manual C2436M-B (9/02)
TABLE OF CONTENTS
IMPORTANT SAFEGUARDS AND WARNINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
ADJUSTMENTS (COLOR CAMERA ONLY) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
VERTICAL PHASE (24 VAC OPERATION ONLY) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
AUTO IRIS LEVEL ADJUSTMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
FOCUS ADJUSTMENT FOR FIXED FOCAL LENGTH LENS WITH AUTO IRIS . . . . . . . . . . . . . . 9
SWITCH SETTINGS FOR FIXED FOCAL LENGTH LENS WITH AUTO IRIS . . . . . . . . . . . . . . . . 9
SWITCH SETTINGS FOR FIXED FOCAL LENGTH LENS WITHOUT AUTO IRIS . . . . . . . . . . . 10
SWITCH SETTINGS FOR VARIFOCAL LENS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
REGULATORY NOTICES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
WARRANTY AND RETURN INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Pelco Manual C2436M-B (9/02) [ 3 ]
[ 4 ] Pelco Manual C2436M-B (9/02)
IMPORTANT SAFEGUARDS AND WARNINGS
1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6 or 6P enclosure, it is designed for indoor use only and must not be installed where exposed to rain and moisture.
3. Use only installation methods and materials capable of supporting four times the maximum specified load.
DESCRIPTION
Designed specifically for the MR5000 Series Public View System, the ICS-DO101ABK Integrated Camera System packages a camera and lens into a small, discreet, high-security dome.
Pelco’s MR5000 Public Viewing Station is specifically designed for retail applications to provide a clear, visual warning to potential shoplifters that these premises are under surveillance. When properly installed the station is an effective deterrent against shoplifting.
INSTALLATION
IMPORTANT
To maximize tamper resistance when not using the side conduit opening for wire connections, verify that the conduit plug and set screw are tight.
1
Attach Adapter Plate to Base of ICS-DO101ABK
1. Align the adapter plate to the base of the ICS-DO101ABK.
2. Using the two 10-32 x .375-inch pan head screws and internal lock washers, attach the base of the ICS-DO101ABK to the adapter plate.
Pelco Manual C2436M-B (9/02) [ 5 ]
2 Prepare Video and Electrical Cabling
1. Temporarily remove the bottom end cap of the MR5000 Series mount if it is installed.
2. Feed the 42-inch video cable (provided) through the monitor feedthrough hole in the mount arm and out the bottom end of the mount arm.
3. Pull power wires through the ICS-DO101ABK feedthrough located at the bottom of the mount arm. Remove the .50-inch plug if it is installed.
4. Pull wires through the adapter plate of the ICS-DO101ABK and into the base of the ICS-DO101ABK.
5. Use the supplied 3/16-inch Allen wrench and slightly loosen
5/16-18 x .75-inch Allen pan head screws that secure the MR5000M mount base to the mount arm.
6. Feed the video cable attached to the ICS-DO101ABK back box through the ICS-DO101ABK feedthrough in the mount arm and out the bottom end of the mount arm.
7. Hook the adapter plate over the loosened screws. Tighten the screws to secure the adapter plate to the mount.
(do not remove)
the two
3 Connect Video and Power
1. Connect the video cable. Place the cable inside the MR5000 Series mount arm and install the bottom end cap of the mount to conceal the cable.
2. Depending on the input voltage, connect either the 12 VDC or 24 VAC input power wires to the appropriate positions on the terminal block inside the base.
3.
12 VDC Operation Only –
The camera is set for 24 VAC operation at the factory. For 12 VDC operation remove the jumper from the 24 VAC position and install it on the 12 VDC position.
[ 6 ] Pelco Manual C2436M-B (9/02)
CAUTION
Heater elements could be hot! When camera power is on, use caution when adjusting the camera. This applies to all models.
4 Install Camera
1. Some indoor installations do not require a
heater. If the installation does not require a heater, remove the heater board from the cam­era assembly. To remove the heater apply pressure and press on the corner of the board.
2. If the heater is installed, plug the heater con­nector from the camera into the mating con­nector inside the base. Plug the video con­nector from the camera into the mating connector inside the base.
Turn on power to the camera and monitor.
3. If you have a varifocal lens, hold the assem­bly in your hand and point the lens toward what you want to view. Loosen the focal length and focus locking screws. Adjust ac­cording to scene detail. Retighten the screws.
4. Always make sure the tab on the camera bracket is pointing out of the enclosure (away from the mount). Gently squeeze the bracket, place it against the shoulder inside the base, and gently release.
Proper camera orientation: The camera bracket tab points out of the enclosure and the top of the camera is pointed in the oppo­site direction.
Pelco Manual C2436M-B (9/02) [ 7 ]
5 Install Dome and
Trim Ring
1. Align the screw holes in the trim ring with those in the camclosure base.
2. Domes with Liners (only) – Position the viewing window over the lens of the camera. a. Loosen the three Phillip screws located in the dome. b. Insert the blade of a standard screwdriver in one of the
adjustment grooves. Move dome into position.
c. Tighten the three Phillip screws to lock liner in place.
3. Tighten the tamper-resistant screws with the supplied 1/8-inch hollow screwdriver bit.
ADJUSTMENT GROOVE
DOME LINER
LOOSEN SCREWS
ADJUSTMENTS (COLOR CAMERA ONLY)
If you have a color camera, it is set up at the factory and normally requires no adjustments. Sometimes, however, adjustments may be necessary.
1. Remove the dome and trim ring using the supplied 1/8-inch hollow screwdriver bit.
2. Adjust the vertical phase, iris level, focus, or switch settings (refer to procedures below).
3. Replace the dome and trim ring.
Ver tical Phase (24 VAC Operation Only)
Adjustment is required if there is vertical roll when switching between two cameras.
1. Reverse the 24 VAC connections on one camera. If both cameras are connected to the same transformer, this should solve the problem.
2. If reversing the connections does not solve the problem, or if cameras are connected to different transformers, turn the adjust­ment screw on one camera (while switching as rapidly as possible between the two camera views) until the switching is clean and there is no vertical roll. If more than two cameras are out of syn-
Auto Iris Level Adjustment
If you have a varifocal lens or fixed focal length lens with an auto iris, you can adjust the level setting to increase or decrease brightness.
[ 8 ] Pelco Manual C2436M-B (9/02)
Focus Adjustment for Fixed Focal Length Lens with Auto Iris
CAUTION
Heater elements could be hot! When camera power is on, use caution when adjusting the camera.
To adjust the focus, it may be necessary to remove the heater board in order to loosen the locking screw on the bottom of the lens.
To remove the heater board:
1. Disconnect the four-pin heater wiring.
2. Wait for the heater elements to cool if they are hot.
3. Apply pressure and press on the corner of the board.
To adjust the focus:
FOCUS ADJUSTMENT SCREW
1. Loosen the locking screw on the bottom of the lens.
2. Move the screw in the slot to bring the picture into focus.
3. Retighten the locking screw.
4. Replace the heater board if it was removed.
5. Reconnect the four-pin heater wiring.
ADJUSTMENT SLOT
BOTTOM VIEW OF CAMERA WITH HEATER BOARD REMOVED
Switch Settings for Fixed Focal Length Lens with Auto Iris
Refer to the switch drawing. The switch is located next to the lens. Automatic backlight compensation (factory setting) is used under varying lighting conditions (such as outdoors) or fixed lighting conditions where there are no bright spots that darken other picture details. Manual backlight compensation is used in fixed lighting conditions to optimize the picture detail when there are bright spots.
ALC/ELC switch: Always ALC
Y/DC switch: Always DC
Auto backlight compensation: BLC switch OFF
ABL switch ON
Manual backlight compensation: BLC switch ON
ABL switch OFF
FACTORY SETTINGS
ALCYBLC
ON
OFF
DC
ELC
= SWITCH POSITION
OFF
ABL
OFF
Pelco Manual C2436M-B (9/02) [ 9 ]
Switch Settings for Fixed Focal Length Lens Without Auto Iris
Refer to the switch drawing. The switch is located next to the lens. Automatic backlight compensation (factory setting) is used under varying lighting conditions (such as outdoors) or fixed lighting conditions where there are no bright spots that darken other picture details. Manual backlight compensation is used in fixed lighting conditions to optimize the picture detail when there are bright spots.
ALC/ELC switch: Always ELC
Y/DC switch: Not used
Auto backlight compensation: BLC switch OFF
ABL switch ON
Manual backlight compensation: BLC switch ON
ABL switch OFF
FACTORY SETTINGS
ALCYBLC
ON
OFF
NOT USED
DC
ELC
= SWITCH POSITION
OFF
ABL
OFF
Switch Settings for Varifocal Lens
The high resolution camera with varifocal lens and auto iris is configured at the factory for optimal performance in lighting conditions where auto iris is required. It is also configured with the shutter speed set at 1/60 (NTSC) or 1/50 (PAL) and AGC
1AWB Automatic white balance 2 GAM Gamma function 3AGC Automatic gain control 4 ESC Electronic shutter control 5 BLC Backlight compensation 6FL Flickerless 7AE Automatic exposure 8 Not used
AE Functions
set at 6 dB of gain.
To enable automatic exposure
Turn on switch 7, and then turn on/off switch 4 for electronic shutter control, switch 5 for backlight compensation, and switch 6 for flickerless motion.
To manually set and lock AWB
Place a white background in front of camera and turn off switch 1.
For gamma correction
Switch to accurately reproduce scene brightness; when turned on, y = 0.6, and when turned off, y = 1.0.
For gain control
Switch 3 On increases gain by 6 dB, and switch 3 Off increases gain by 18 dB.
FACTORY SETTINGS
12345678
OFF
= SWITCH POSITION
To enable auto iris and manually set shutter speed
Turn off switch 7; set switches 4, 5, and 6 for the desired shutter speed.
CAUTION
Do not change the shutter speed unless you understand how changing the settings will affect the scene detail.
Shutter Switch Number and Position
Speed 7 6 5 4
1/60 (NTSC) 1/50 (PAL) 1/100 Off On On 1/250 On Off On 1/500 Off Off On 1/1000 On On Off 1/2000 Off On Off 1/4000 On Off Off 1/10000 Off Off Off
On On On
Off
[ 10 ] Pelco Manual C2436M-B (9/02)
SPECIFICATIONS
Electrical
Input Voltage: 12 VDC or 24 VAC, ±10% Power Consumption: 13 watts or less Video Connector: BNC Operating Te mperature: -50° to 122°F (-46° to 50°C)
De-ices to -10°F (-23°C)
General
Cable Entry: 3/4-inch (1.91 cm) conduit fitting
and 3/4-inch (1.91 cm) opening
for NPT threaded pipe Pan/Tilt Adjustment: Manual; 360° pan; 180° tilt
(Design and product specifications subject to change without notice.)
Ratings: NEMA 4, IP 66 when installed
properly CE UL/cUL
Construction: Aluminum with steel camera
mounting bracket and polycar-
bonate dome Finish: Gray polyester powder coat Dimensions
Base: 3.70 (H) x 5.30 (W) inches
(9.40 x 13.50 cm)
Bubble: 3.75-inch diameter
Environment: Low temperature,
indoor/outdoor Unit Weight: 2.20 lb (1.00 kg)
Regulatory Notices
FCC Class A (monochrome, EIA cameras only)
This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the in­struction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to cor­rect the interference at his own expense.
FCC Class B (color, NTSC cameras only–except varifocal)
This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interfer­ence by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Pelco Manual C2436M-B (9/02) [ 11 ]
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
• Five years on FT/FR8000 Series fiber optic products.
• Three years on Genex
• Three years on Camclosure MC3651H-2X camera models, which have a five-year warranty.
•Two years on standard motorized or fixed focal length lenses.
•Two years on Legacy
•Two years on Spectra
•Two years on Esprit
• Eighteen months on DX Series digital video recorders, NVR300 Series network video recorders, and Endura products.
• One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.
• Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department Pelco 3500 Pelco Way Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA
®
Series products (multiplexers, server, and keyboard).
®
and fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and
®
, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products.
®
, Esprit®, ExSite™, and PS20 scanners, including when used in continuous motion applications.
®
and WW5700 Series window wiper (excluding wiper blades).
Series distributed network-based video
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors 473 Eccles Avenue South San Francisco, CA 94080 USA Phone: 650-737-1700 Fax: 650-737-0933
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco.
Endura and ExSite are trademarks of Pelco.
©Copyright 2002, Pelco. All rights reserved.
REVISION HISTORY
Manual # Date Comments
C2436M 9/01 Original version. C2436M-A 7/02 Added instructions for fixed lens with auto iris. C2436M-B 9/02 Revised installation instructions – bracket and camera assembled at factory. Added iris level
adjustment for fixed lens with auto iris.
[ 12 ] Pelco Manual C2436M-B (9/02)
Loading...