Pelco MPT9008CZ User Manual

®
MPT9008PZ/CZ
Coaxitron Switcher/Controller
Installation/Operation Manual
C558M (3/96)
Pelco • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • www.pelco.com
(800) 289-9100 or (1-559) 292-1981 • FAX (800) 289-9150 or (1-559) 292-3827
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120
TABLE OF CONTENTS
Section Page
1.0 WARNINGS ...................................................................................................................................... 1
2.0 SCOPE .............................................................................................................................................2
3.0 DESCRIPTION .................................................................................................................................2
4.0 INSTALLATION................................................................................................................................. 3
4.1 TERMINATING CONFIGURATION ........................................................................................... 3
4.2 NONTERMINATING LOOP-THROUGH CONFIGURATION ..................................................... 3
5.0 OPERATION ..................................................................................................................................... 5
5.1 SWITCHER/CONTROLLER ...................................................................................................... 5
5.1.1 Controls ........................................................................................................................... 5
6.0 MODELS .......................................................................................................................................... 6
7.0 SPECIFICATIONS ............................................................................................................................ 6
8.0 WARRANTY AND RETURN INFORMATION ................................................................................... 7
Pelco, the Pelco Logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco. © Copyright 1996, Pelco. All rights reserved.
Endura and ExSite are trademarks of Pelco.
LIST OF ILLUSTRATIONS
Figure Page
1 MPT9008CZ–Front View ................................................................................................................... 2
2 MPT9008CZ–Rear View .................................................................................................................... 3
3 MPT9008PZ/CZ–Configuring for Loop-Through Operation............................................................... 4
4 MPT9008PZ/CZ–Homing/Terminating Configuration ........................................................................4
5 MPT9008PZ/CZ–Homing/Looping Configuration .............................................................................. 5
REVISION HISTORY
Manual # Date Comments
C558M 3/96 Original version
Pelco Manual C558M (3/96) iii
(This page intentionally left blank.)
iv Pelco Manual C558M (3/96)
INSTALLATION/OPERATION MANUAL MPT9008PZ/CZ COAXITRON SWITCHER/CONTROLLER
1.0 WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
3. Only use replacement parts recommended by PELCO.
This product may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present
within this unit.
4. After replacement/repair of this unit’s electrical components, conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry.
This symbol indicates that there are important operating and maintenance instructions in the
literature accompanying this unit.
CAUTION:
TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER. NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
RISK OF ELECTRIC SHOCK.
CAUTION:
DO NOT OPEN.
Please thoroughly familiarize yourself with the information in this manual
prior to installation and operation.
Pelco Manual C558M (3/96) 1
2.0 SCOPE
CAMERA/LENS FUNCTIONS
The information contained within this manual covers the installation and operation of the MPT9008PZ/CZ Coaxitron Switcher/Controller.
Please thoroughly familiarize yourself with the infor­mation in this manual prior to installation and operation.
3.0 DESCRIPTION
As the name implies, the MPT9008PZ/CZ Coaxitron Switcher/Controller is a unit that provides both a Con­troller and Switcher in the same electronics package. (Reference Figure 1.) The integration of these dual functions into one package combines the functionality of the Coaxitron transmitter/controller and the conve­nience of an 8-input passive switcher with loop-through capabilities. The transmitter/controller provides up to 16 remote control functions without the need for control cables other than for a dedicated video cable for the normal transmission of a remote camera signal to the local monitoring and control position. The MPT9008PZ/ CZ lends itself to application in situations where short­to-medium distances are involved.
Typically, these 16 transmitter/control functions can be grouped as follows:
PTZ FUNCTIONS
1. Pan Left 5. Zoom In
2. Pan Right 6. Zoom Out
3. Tilt Up 7. Focus Near
4. Tilt Down 8. Focus Far
9. Iris Open 11. Camera Power On/Off
10. Iris Close 12. Auto/Manual Scan
AUXILIARY FUNCTIONS
13. AUX 1 (Manual Iris) 15. AUX 3
14. AUX 2 (Auto Iris) 16. AUX 4
Functions 1 through 10, 15 and 16 are momentary; that is, they are only actuated while the associated control switch located on the Coaxitron Switcher/Controller front panel is operated. Functions 11, 12, 13 and 14 are latching; that is, camera power, auto scan, and auto/ manual iris are latching functions and remain on until turned off. The latching iris function is not dedicated, and with proper interfacing, it can be used for some other latching function. Alternately, AUX 1, 2, 3 and 4 may be used as momentary functions to control such things as lights or gates with proper external interfacing. Up to ten functions can be operated simultaneously. Functions 11 through 16 must be used individually; although any one of these functions may be used simul­taneously with functions 1 through 10. These control functions are active and control only the camera posi­tion that is currently selected by the push buttons (1-8) on the front panel of the unit.
The switcher portion of the MPT9008CZ/PZ provides a convenient, inexpensive and reliable method of switch­ing up to 8 video inputs, one at a time, to a single monitor output. All switching is accomplished utilizing inter­locked manual push buttons. The number on each push button corresponds to the video input BNC on the rear of the unit; i.e., push button #1 corresponds to video input #1, etc. When any push button is depressed, the corresponding video input is displayed on the monitor and coax control functions are enabled for that camera position.
Figure 1. MPT9008CZ–Front View
2 Pelco Manual C558M (3/96)
The MPT9008PZ/CZ is shipped with terminated BNC inputs; however, the user can configure the unit for loop-through operation. See Section 4.2 and Figure 3. This makes it possible to loop signals through the MPT9008PZ/CZ switcher/controller to an additional switcher/controller and monitor at a remote location where the signal is terminated. Any switcher can be used at the second location and operate completely independent of the first location.
4.0 INSTALLATION
4.2 NONTERMINATING LOOP-THROUGH
CONFIGURATION
To configure the MPT9008PZ/CZ for loop-through operation reference Figure 3 and perform the following steps:
1. Remove power from the unit if not already done.
2. Remove the cover from the unit to expose the BNC inputs located in the left, rear, back panel area.
MPT9008PZ/CZ Switcher/Controllers can be installed in a number of configurations depending on your sys­tem requirements. The two basic types of configuration possibilities are shown in Figures 4 and 5, respectively, depending on whether or not the unit is configured as terminating or as loop-through.
4.1 TERMINATING CONFIGURATION
Both models of the switcher/controller are shipped from the factory as homing, terminated units. See section 4.2 for configuring the MPT9008PZ/CZ for loop-through operation.
3. Each BNC’s video input has a corresponding, like numbered, front panel push button. Associated with each BNC is a resistor as illustrated in Figure
3. Clip only the leads of those resistors whose video input you wish to configure as being loop-through. Figure 3, for example, shows the resistor lead for video input #1 being clipped.
4. After making the desired changes, replace the cover and resume operation.
NOTE: Looping switcher/controllers do not have internal termination. Inputs must be terminated with 75 ohms by other equipment in the system.
Figure 2. MPT9008CZ–Rear View
Pelco Manual C558M (3/96) 3
Figure 3. MPT9008PZ/CZ–Configuring for Loop-Through Operation
Figure 4. MPT9008PZ/CZ–Homing/Terminating Configuration
4 Pelco Manual C558M (3/96)
Figure 5. MPT9008PZ/CZ–Homing/Looping Configuration
5.0 OPERATION
In general, all operating controls on the transmitter are self explanatory. With the exception of the ON/OFF power switch and the 8-position joystick, all controls are center-off, spring return paddle switches (momen­tary on-off-on).
5.1 SWITCHER/CONTROLLER
The transmitter switcher/controller is housed in a 1-3/4" high enclosure, supplied as either a desk top unit (CZ suffix) or as a rack mount unit (PZ suffix). Up to eight video BNC connector inputs are available on the rear of the unit. Any of these video inputs are switch selectable, one at a time, to the available monitor and, while selected, coax control functions for the pan/tilt and camera are enabled.
Pelco Manual C558M (3/96) 5
5.1.1 Controls
Power ON/OFF Rocker switch Pan/Tilt 8-position joystick Zoom Paddle switch Tele/Wide Focus Paddle switch Near/Far Iris Paddle switch Open/Close Aux 1,2 Paddle switch Auto/Manual
Iris (latching function)
Camera Power Paddle switch On/Off (latching
function)
Pan Auto/Man Paddle switch Manual/Auto
(latching function)*
Aux 3, 4 Paddle switch (momentary
functions)*
*External requirements are needed for operation
6.0 MODELS
MPT9008CZ Coaxitron Switcher/Controller
capable of handling and/or controlling 8 video inputs, one at a time. 120 VAC input.
MPT9008CZ/220 Same as MPT9008CZ except
230 VAC input.
MPT9008PZ Same as MPT9008CZ except
rack-mount.
MPT9008PZ/220 Same as MPT9008PZ except
230 VAC input.
7.0 SPECIFICATIONS
ELECTRICAL
Input Voltage: 120 VAC, 60 Hz or 230 VAC,
50 Hz
Operating Distance: Cable distances are approximate
according to cable type used. 75 ohm coax required.
Cable Distance
Type Distance Using EA2000
RG59U 750 ft 9229 m) 3,000 ft (914.4 m) RG6 1,500 ft (457 m) 4,500 ft (1,371.6 m) RG11 1,800 ft (549 m) 6,000 ft (1,828.8 m) RG15 8,000 ft (2,438.4 m)
GENERAL
Ambient Temperature: -32°F to +120°F
(0°C to +48.89°C)
VIDEO
Power Consumption: Transmitter 2.5vA
Control Method: 15-pulse train (pulse width
modulated) superimposed on the video signal during the vertical blanking interval by the control transmitter. Pulse train occupies 1 TV line period
Pulse Amplitude: Approximately 1V p-p added to
video signal, 333 kHz nominal
Connectors:
Control/ Transmitter 16 BNC connectors; 8 for video
inputs, 8 for looping outputs
Monitor 1 BNC connector
Input Video Level: 1V p-p nominal; 2V p-p maxi-
mum at less than 75% APL;
1.5V p-p maximum at 90% APL
Inputs: 8 video signal inputs
Video Connectors: BNC
Termination: Input—75 ohm internal termina-
tion. Loop-through capability via clipped leads
Fuse Protection: 3 AG type:
120VAC, 2/10A, SB 230VAC, 1/10A, SB
Power Cord: 3-wire grounded #18 AWG
6 Pelco Manual C558M (3/96)
8.0 WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
• Five years on FT/FR8000 Series fiber optic products.
• Three years on Genex keyboard).
• Three years on Camclosure® and fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models, which have a five-year warranty.
• Two years on standard motorized or fixed focal length lenses.
• Two years on Legacy®, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products.
• Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, includ­ing when used in continuous motion applications.
• Two years on Esprit wiper blades).
• Eighteen months on DX Series digital video recorders, NVR300 Series network video recorders, and Endura network-based video products.
• One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.
• Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state. If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice
number
3. Details of the defect or problem If there is a dispute regarding the
warranty of a product which does not fall under the warranty conditions stated above, please include a written explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
®
Series products (multiplexers, server, and
®
and WW5700 Series window wiper (excluding
Series distributed
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department Pelco 3500 Pelco Way Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors 473 Eccles Avenue South San Francisco, CA 94080 USA Phone: 650-737-1700 Fax: 650-737-0933
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.
Pelco Manual C558M (3/96) 7
®
Pelco
3500 Pelco Way, Clovis, CA 93612-5699
(559) 292-1981 • (800) 289-9100
FAX (800) 289-9150 or (559) 292-3827
(Product specifications subject to change without notice.)
C558M
8 Pelco Manual C558M (3/96)
Loading...