Prior to installation and use of this product, the following WARNINGS should be observed:
1.Installation and servicing should only be done by Qualified Service Personnel and
conform to all Local codes.
2.Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6 or 6P enclo-
sure, it is designed for indoor use only and it must not be installed where exposed to
rain or moisture.
3.Only use replacement parts recommended by Pelco.
4.After replacement/repair of this unit’s electrical components, conduct a resistance
measurement between line and exposed parts to verify the exposed parts and have
not been connected to line circuitry.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a
risk of electric shock is present within this unit.
This symbol indicates that there are important operating and
maintenance instructions in the literature accompanying this
unit.
CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. NO USER-SERVICEABLE
PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
Please thoroughly familiarize yourself with the information in this manual prior to installation
and operation.
Pelco Manual C545M-E (2/02)3
Page 4
DESCRIPTION
The MPS5DT and MPS524DT Scanner Controls provide precise and reliable control of
Pelco PS20 and PS20-24 Series Scanners. The controls can still be used with older scanner models such as Pelco PS7, PS7-24, PS30A, and PS30-24.
An additional line is available to power the PS20 scanner and camera/enclosure eliminating
the need for power at the scanner location.
The front panel switches operate left and right control, and automatic scan control.
These controls can be used as desktop models or up to three units can be rack mounted in
a R300 Rack Kit.
Use the RB24 Relay Box to extend the control’s operating distance up to 13,000 feet using
16 AWG.
MODELS
MPS5DTDesktop control for 120 VAC scanners (PS20, PS30A) UL
MPS524DTDesktop control for 24 VAC scanners (PS7-24, PS20-24, PS30-24) UL
MPS524DT/220Same as MPS524DT except with 230 VAC input; Desktop control for
OPTIONS
R300Rack mount kit. Up to three units can be racked horizontally in a single
RB115Low voltage relay box for use with 24 VAC control and 120 VAC scan-
RB24Low voltage relay box for use with 24 VAC control and 24 VAC scan-
24 VAC scanners (PS7-24, PS20-24, PS30-24) CE
rack kit.
ners. Extends operating distance (control to relay box) up to 13,000
feet using 16 AWG.
ners. Extends operating distance (control to relay box) up to 13,000
feet using 16 AWG.
4Pelco Manual C545M-E (2/02)
Page 5
INSTALLATION
The following items are supplied:
•MPS5DT, MPS524DT, or MPS524DT/220
•6-pin mating connector with pins
•2 screws
CONNECTOR ASSEMBLY
The first thing you must do is assemble the mating connector. The following steps apply to
all AMP style connectors regardless of pin size or pin number. Refer to Figure 1 during assembly.
1.Slide the connector clamp assembly over the conductor cable.
NOTE:
Pin 5 is not used
with PS7 and PS30 Series
Scanners.
2.Determine the size of wire to use. Refer to the
Specifications
section.
3.Prepare the wires from the conductor cable as follows:
a.Strip at least 1" from the cable jacket to expose the wires. You may need to strip
more from the cable jacket if you have more wires.
b.Strip 1/8" from each wire.
c.Using an AMP-style crimper, crimp the wires and their insulation to the connector
pins. Refer to Detail A in Figure 1.
4.Slide the connector pins into the appropriate holes in the connector body until they
snap into place. You can see the pin assignments in Table A.
Table A. PIN Assignments
PINFUNCTION
1Common/AC Low
2Right
3Left
4Auto
5120 VAC HI for PS20 scanner and camera power or
8Chassis Ground
5.Push the connector clamp assembly towards the connector body and screw it onto the
connector body. Be careful not to disturb the wires.
24 VAC HI for PS20-24 scanner and camera power
6.Attach the appropriate clamp with the screws provided and tighten.
1/8"
1"
FRONT VIEW
OR
13
47
811
1214
00103
Figure 1. Connector Assembly
Pelco Manual C545M-E (2/02)5
Page 6
COMPLETING THE INSTALLATION
1.Attach the mating connector to the connector on the rear of the scanner control.
2.Attach the other end of the cable to the scanner.
3.Plug the power cord on the back of the scanner control into a 120 VAC outlet
(MPS5DT and MPS524DT models) or a 230 VAC outlet (MPS524DT/220 model).
OPERATION
Turn the control on and test its operation using the following procedures:
MANUAL OPERATION
Move the rocker switch to the “MANUAL” position.
When you move the other rocker switch to the “LEFT” position, the scanner pans to the left.
When you move it to the “RIGHT” position, the scanner pans to the right.
AUTO SCAN OPERATION
Move the rocker switch to the “AUTO” position.
The scanner pans to the right until it reaches its limit, then pans to the left.
The scanner automatically continues right/left panning until the “MANUAL” switch is set
again or the scanner is turned off.
SPECIFICATIONS
CONTROLS
Left/Right:Rocker switch, LEFT/RIGHT
Auto Scan:Rocker switch, AUTO/MANUAL
Power:Rocker switch, ON/OFF
Pilot Lamp:Long life neon
Power Cord:Unit is supplied with grounded power cord (either U. S. Standard
or Continental European Standard)
Output Connector:AMP CPC type, 14 pin (mate supplied)
Cable Requirements:4 conductors for PS7/PS30 models and 6 for PS20/PS20-24 models
Operating Distances:The following are the recommended cable distances between the
control and the listed scanners. The PS20 and PS20-24 are pow-
ered locally and do not use power from the controller.
20 AWG18 AWG16 AWG
(0.5 mm2)(1.0 mm2)(1.5 mm2)
PS7-24
PS30A
PS30-24
PS20
PS20-24
745 ft1185 ft1885 ft
(227 m)(361 m)(575 m)
2265 ft3605 ft5720 ft
(690 m)(1098 m)(1743 m)
115 ft185 ft295 ft
(35 m)(56 m)(90 m)
2,300 ft3,700 ft5,900 ft
(701 m)(1,127 m)(1,798 m)
5,600 ft9,000 ft14,300 ft
(1,706 m)(2,743 m)(4,368 m)
NOTE: A relay box can be used to extend the maximum operating
distance (control to relay box) to 13,000 feet using 16 AWG.
GENERAL
Construction
Cover:Steel, black polyester powder coat
Chassis:Steel, zinc plated
Panel:Aluminum, black polyester powder coat with white silkscreen
Unit Size:5.50 (W) x 1.75 (H) x 8.90 (D) inches (13.97 x 4.45 x 22.61 cm)
Refer to Figure 2.
Unit Weight
MPS5DT:3 lb (1.36 kg)
MPS524DT:4 lb (1.80 kg)
MPS524DT/220:4 lb (1.80 kg)
(Design and specifications are subject to change without notice.)
Figure 2. Dimension Drawing
Pelco Manual C545M-E (2/02)7
Page 8
REGULATORY NOTICES
This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective
in material or workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
• Five years on Pelco manufactured cameras (CC3500/CC3600 and MC3500/
MC3600 Series); two years on all other cameras.
• Three years on Genex® Series (multiplexers, server, and keyboard).
•Two years on cameras and all standard motorized or fixed focal length lenses.
•Two years on Legacy®, Camclosure™ Camera Systems, CM6700/CM6800/
CM8500/CM9500/CM9740/CM9760 Matrix, DF5 and DF8 Series Fixed Dome
products.
•Two years on Spectra®, Esprit™, and PS20 Scanners, including when used
in continuous motion applications.
•Two years on WW5700 series window wiper (excluding wiper blades).
• Eighteen months on DX Series digital video recorders.
• One year (except video heads) on video cassette recorders (VCRs). Video
heads will be covered for a period of six months.
• Six months on all pan and tilts, scanners or preset lenses used in continuous
motion applications (that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of
Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid
to Pelco, Clovis, California. Repairs made necessary by reason of misuse,
alteration, normal wear, or accident are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss
resulting from the specific use or application made of the Products. Pelco’s
liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall
not exceed the price paid by the Dealer to Pelco for such Products. In no event
will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether
by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer
may also have additional rights, which are subject to variation from state to state.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100
or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide
the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall
under the warranty conditions stated above, please include a written explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by which
the item was received by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call
the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and
refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned
CA or RA number and freight should be prepaid. Ship to the appropriate
address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico:
Intermediate ConsigneeUltimate Consignee
American Overseas Air FreightPelco
320 Beach Road3500 Pelco Way
Burlingame, CA 94010Clovis, CA 93612-5699
USAUSA
REVISION HISTORY
Manual #DateComments
C545M3/85Original version.
C545M1/90Rev. A. Revised to include MPS524DT/220.
C545M9/90Rev. B. Revised page 2 and Figures 2 and 6.
C545M-C10/94Rev. C. Revised to 2-Column Format. Incorporated new wiring diagrams (Figs. 5 and 6) and updated fuse values per
ECO #94-482. Revised Figure 2 and cable assembly instructions in Section 4.1.
C545M-D6/96Rev. D.Figures 5 and 6 revised to include new wire colors and new transformer, part #TRF22282.30.70F.
3/97Fuse value updated in Figure 6.
5/97Manual formatted to new style. Optional R300 Rack mount instructions removed. Figures 4 and 5 updated per ECO
#97-125 (wiring colors and connections).
C545M-E2/02Manual formatted to new style. New scanner models added. Figures 2-4 removed.