MC3820 and MC5720 Cameras Installation Instructions
INTRODUCTION
These instructions cover Pelcos MC3820 and MC5720 Series cameras. Read all of these instructions.
Use them to install your camera and have them available for its lifetime. Refer to Table A for the
camera models and their features. All cameras in the range are fitted with a direct drive (DD) lens
connector, have adjustable back focus and accept C and CS lenses.
TABLE A
Option
MC3820-3
MC3820-2X
MC5720-3
MC5720-2X
Monochrome
Resolution (TVL)
Sensitivity (lux @ f1.2)
CCD Sensor size
380 380 570 570
0.10.10.10.1
1/3“ 1/3“ 1/3“ 1/3“
Sony HyperHAD CCD
Adjustable Gamma (0.45 and 1.0)
Automatic Gain Control (AGC)
Backlight Compensation (BLC)
BLC on/off
Electronic Iris (EI)
EI on/off
Auto Iris connection
Line lock with phase adjust (AC only)
Page 2
Dimensions
4.82 (L) x 2.57 (W) x 2.34 (H) inches
(12.25 x 6.55 x 5.95 cm)
Supply
11 - 40 VDC or 14 - 30 VAC, 50/60Hz
230 VAC + 10% -15% 50Hz
Installation Instructions MC3820 and MC5720 Cameras
PRODUCT SAFETY
Ensure installation and servicing is carried out by qualified personnel.
Isolate from the supply circuit before any servicing.
Installation method and materials must be capable of supporting four times the total
weight of the unit.
Power supply cords must be connected as defined in national electrical codes of
practice for Class 1 earth protected equipment.
Low voltage cameras must be connected as defined in national electrical codes of
practice for Class 2 protection of double or reinforced insulation.
Safety critical components must only be replaced with recommended parts.
The maximum load on the rear (auto-iris) connector must not exceed 50 mA.
The maximum load on the direct drive connector must not exceed 25 mA.
REGULATORY NOTICES
Federal Communications Commission Part 15 - Digital devices
This Device complies with part 15 of the FCC rules. Operation is subject to the following two
conditions:
(1)this device may not cause harmful interference, and
(2) this device must accept any interference that may cause undesired operation.
CERTIFICATIONS
This product meets the requirements of the following standards:
Electromagnetic Compatibility
EN55022: 1995 limits and methods of measurement of radio disturbance characteristics of information
technology
EN50082-1: 1992 Generic immunity standard
Comprising:
IEC 1000-4-2:1995 Electrostatic discharge
IEC 1000-4-3:1995 Radiated electromagnetic fields
IEC 1000-4-6: Immunity to conducted disturbances, induced by radio-frequency fields
IEC 1000-4-4:1995 Fast transient bursts
Safety
EN 60950: 1992 Safety of information technology equipment, including electrical business equipment
DECLARATIONS
The manufacturer declares that the equipment supplied with this manual is compliant with the EMC
directive 89/336 EEC and the low voltage directive 73/23 EEC and CE marked accordingly.
Page 3
MC3820 and MC5720 Cameras Installation Instructions
CAUTIONS
CAUTION
In order to avoid damaging your camera, note the following points.
1) The camera has threaded mounting points on the top and bottom of the case. Only
use a standard, photographic mounting bolt with a 1/4-20 UNC thread.
2) Before fitting the lens, make sure that its back will not touch the CCD sensor or
associated components when fully installed.
3) Do not touch the image surface of the sensor. If the sensor is accidentally touched,
only clean it using isopropanol.
4) Do not expose the sensor to direct sunlight as this may impair the performance of
the camera.
POWER SUPPLY
The MC3820 and MC5720 Series cameras are available in 230 VAC or 11-40 VDC/14-30 VAC low
voltage types. The voltage required to operate the camera is clearly marked on the rear
panel of the camera. Power the low voltage cameras only from a class 2 isolated power
supply. The power consumption is less than 5 Watts.
230 VAC Power Supply
Cameras that are intended to operate directly from 230 VAC are fitted with a non-detachable power
supply cord. The voltage of operation is clearly marked on the rear panel of the camera. Generally
this is 230 VAC +10% /-15% at 50 Hz. Refer to the wiring instruction label attached to the supply
cord and terminate the cord with the appropriate circuit with a 3A fuse. CAMERAS MUST BE
CONNECTED TO A PROTECTIVE EARTH GROUND. Ensure that a secure means of isolation from
the AC power is provided for the camera in accordance with the national wiring regulations of the
country of installation.
Auto-switching power supply
Cameras fitted with an automatic selecting power supply operate between 11-40 VDC and 14-30
VAC. Connections and polarity are indicated above the screw terminals on the rear panel. The
power supply must be a class 2 isolated type.