Table A. Recommended Wire Gauge and Wiring Distances ............................................................ 9
Table B. Video Coaxial Cable Requirements ....................................................................................9
Pelco Manual C1982M-A (12/00) [ 3 ]
IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by qualified service and installation personnel.
2. Installation shall be done in accordance with all local and national electrical and mechanical
codes utilizing only approved materials.
3. Use only installation methods and materials capable of supporting four times the maximum
specified load.
4. Use only UL listed class 2 power supply.
5. To prevent fire or shock hazard, do not expose this appliance to rain or moisture.
DD/AI Lens Connector
The maximum load for a direct drive lens must not exceed 25 mA.
The maximum load for an auto-iris lens must not exceed 50 mA.
REGULATORY NOTICES
This equipment has been tested and found to comply with the limits of a Class B digital device,
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off and on, the user
is encouraged to try and correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device many not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
[ 4 ] Pelco Manual C1982M-A (12/00)
DESCRIPTION
The MC3500 and MC3600 Series are compact, monochrome video cameras with a 1/3-inch CCD imager. All
cameras have a direct drive/auto iris lens connector and adjustable back focus, and accept C and CS lenses.
Models
MC3500S-2Standard resolution, 330 TV lines, HyperHAD™ CCD, 1.0 lux at f1.2, EIA
MC3500S-2XStandard resolution, 380 TV lines, Hyper HAD+ CCD, 0.1 lux at f1.2, CCIR
MC3600H-2High resolution, 480 TV lines, EXview HAD CCD™, 1.0 lux at f1.2, EIA
MC3600H-2XHigh resolution, 570 TV lines, EXview HAD+ CCD 0.05 lux at f1.2, CCIR
Pelco Manual C1982M-A (12/00) [ 5 ]
CAMERA LAYOUT
BACK FOCUS
ADJUSTMENT
RING
BACK FOCUS
ADJUSTMENT
LOCKING
SCREW
MOUNT ADAPTER
PHASE ADJUSTMENT
LEVEL ADJUSTMENT
POWER SUPPLY
COSMETIC TRIM
RING
BNC VIDEO CONNECTOR
LENS CONNECTOR
LED
DIP SWITCHES
Figure 1. Camera Layout
NOTE: The cosmetic trim ring conceals the LED light for more discreet surveillance operations.
The trim ring also hides the power connectors and protects the DIP switches.
INSTALLATION
Lens Mounting
The MC3500 and MC3600 Series cameras can use fixed iris, manual iris, auto iris, or direct drive
lenses. Cameras are factory-set for CS-mount lenses, but easily adjusted for C-mount lenses.
1. C-Mount Lens Only - Loosen the two back focus locking screws. Rotate the back focus
adjustment ring fully counterclockwise before installing the C-mount lens (refer to the section on
Back Focus Adjustment
2. Remove the cosmetic trim ring from the back of the camera (refer to Figure 1). Set the lens mode
selector switch on the side of the camera to AI (auto iris video drive lens)or DD (auto iris DC drive
lens). Refer to the
3. Screw the lens onto the lens mount. Be careful to prevent dust from entering the space between the
lens and the CCD element. If necessary, use clean, compressed air to remove any foreign matter.
4. Thread the lens cable through the cosmetic trim ring.
5. Connect the direct drive (DD) or auto iris (AI) lens to the 4-pin iris drive connector located on the
side of the camera. Refer to Figure 2 for the pin connections for the iris drive connector.
).
Switch Settings
section. Switch setting is determined by the type of lens used.
Use a standard 1/4-20 screw (provided) with a maximum thread length of 3/8-inch (10 mm) for top or
bottom camera mounting. The mount adapter may be fitted to the top or bottom of the camera. The
camera is shipped with the mount adapter located on the top of the camera.
To change the mount adapter position:
1 Remove the four screws from the mount adapter located on the top of the camera.
2 Remove the trim cover from the bottom of the camera by prying it loose. Place the trim cover on
the top of the camera where the mount adapter was removed. Press into place.
3 Install the mount adapter to the bottom of the camera. Secure with the four screws removed in
step 1.
1
2
3
Figure 3. Camera Mounting
Pelco Manual C1982M-A (12/00) [ 7 ]
POWER AND VIDEO CONNECTIONS
To connect the camera power and video do the following:
1. Remove the rear cover from the camera (refer to Figure 1). Thread cabling through the rear cover.
2. Connect the power cable to the two pin power connector on the back of the camera using the terminal block connector provided. Refer to Table A for the recommended wire gauge to use for the
installation
3. Connect a video cable to the SIGNAL OUT connector (BNC) on the back of the camera. Refer to
Table A for the type of the video coaxial cable to use.
4. Reattach the rear cover to the back of the camera.
Power Connections
MC3500 and MC3600 Series cameras are designed to operate from a 12 VDC or 24 VAC power supply.
The power supply connections are shown in Figure 4. The LED on the back panel of the camera indicates
that power is connected. Use only a Class 2 isolated power supply. Power consumption is less than 4 watts.
CLASS 2
ISOLATED
POWER
SUPPLY
24 VAC12 VDC
CLASS 2
ISOLATED
POWER
SUPPLY
Figure 4. Power Supply Connections
To connect the camera power and video:
1. Remove the cosmetic trim ring from the camera (refer to Figure 1). Thread cabling through the
rear cover.
2. Connect the power cable to the two pin power connector on the back of the camera using the terminal block connector (provided). Refer to Table A for the recommend wire gauge and wiring distances.
3. Connect a video cable to the SIGNAL OUT connector (BNC) on the back of the camera. Refer to
Table B for the type of video coaxial cable to use.
4. Reattach the trim ring to the back of the camera.
AC Operation Only – If you are wiring more than one camera to the same transformer, connect one
side of the transformer to the same terminal on all cameras, and connect the other side of the transformer to the remaining terminal on all cameras. Failure to connect all of the cameras the same way
will cause the cameras to be out of phase with each other and may produce a vertical roll when
switching between cameras.
[ 8 ] Pelco Manual C1982M-A (12/00)
Table A. Recommended Wire Gauge and Wiring Distances
The following are the recommended maximum distances for 24 VAC applications and are calculated
with a 10-percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for
AC-powered devices.)
EXAMPLE: A camera that requires 10 vA and is installed 283 feet (86 m) from the transformer
would require a minimum wire gauge of 20 AWG.
NOTE:Distances are calculated in feet; values in parentheses are meters.
Table B. Video Coaxial Cable Requirements
Cable Type*Maximum Distance
RG59/U750 ft (229 m)
RG6/U1,000 ft (305 m)
RG11/U1,500 ft (457 m)
* Minimum cable requirements:
75 ohms impedance
All-copper center conductor
All-copper braided shield with 95% braid coverage
Pelco Manual C1982M-A (12/00) [ 9 ]
LENS SETUP AND FOCUS PROCEDURES
Video Drive Auto Iris Lens
When a video drive auto iris lens is used, the lens mode selector switch must be set to AI. Switch the
EI and AGC OFF. Refer to the lens instructions and adjust the lens for the optimum picture (video output level of 1V peak-to-peak). Switch the AGC ON. To focus, fully open the iris by covering the lens
with a suitable neutral density (ND*) filter. If the viewed scene is 6.5 feet (2 m) away or farther, set the
lens focus to infinity (far). Use the back focus adjustment ring (refer to the
Back Focus Adjustment
section) and focus on the selected scene. Remove the ND filter and set the lens focus as required.
Direct Drive (DC) Auto Iris Lens
When a direct drive lens is used, the lens mode selector switch must be set to DD. Switch the EI
and AGC OFF. Use an appropriate screwdriver to turn the lens level potentiometer (refer to Figure 1)
fully clockwise. Next, slowly adjust the potentiometer counterclockwise until the optimum picture is
obtained (video output level of 1V peak-to-peak). Switch the AGC ON. To focus, fully open the iris by
covering the lens with a suitable neutral density (ND*) filter. Select the scene to be viewed. If the
viewed scene is 6.5 feet (2 m) away or farther, set the lens focus to infinity (far). Use the back focus
adjustment ring (refer to the
Back Focus Adjustment
section) and focus on the selected scene. Re-
move the ND filter and set the lens focus as required.
Fixed Lens
Set the EI switch and AGC switch to ON. To focus, set the lens focus to infinity and view an image
greater than 6.5 feet (2 m) away. Focus the image with the back focus adjustment ring (refer to the
Back Focus Adjustment
section). Set the lens focus as required.
Manual Iris Lens
Set the EI switch and AGC switch to ON. To focus, open the iris fully and set the lens focus to infinity.
View an image greater than 6.5 feet (2 m) away. Focus the image with the back focus adjustment
ring (refer to the
Back Focus Adjustment
section). Adjust the lens focus and set the iris for the best
picture quality. The largest aperture gives the best light sensitivity, the smallest aperture the greatest
depth of field.
Zoom Lens
Set the lens focus to infinity (far) and fully open the iris by covering the lens with a suitable neutral
density (ND*) filter. Zoom out to the widest field of vision and view a distant object. Adjust the back
focus adjustment ring until the object is in focus (refer to the
Back Focus Adjustment
section). Next,
zoom fully in and adjust the lens focus until the object is again focused. Repeat these steps until the
full zoom range may be viewed with the minimum loss of focus.
5
AGC ON
5
AGC OFF
DIP SWITCH SETTINGS – WHITE REPRESENTS SWITCH POSITION
4
EI OFF
4
EI ON
Figure 5. AGC and EI Switch Settings
*NOTE: For best results, outdoors, use an ND3 filter.
[ 10 ] Pelco Manual C1982M-A (12/00)
BACK FOCUS ADJUSTMENT
The back focus adjustment is located at the front of the camera and is accessible from either side of
the case.
To adjust the back focus:
1. Loosen the two back focus locking screws (one on each side).
2. Turn the back focus ring:
a. Clockwise - Moves the CCD sensor assembly towards the back of the lens.
b. Counterclockwise - Moves the CCD sensor away from the lens.
3. When the back focus adjustment is satisfactory, tighten the locking screws. Do not over-turn or
force the back focus adjustment ring.
E
IS
W
K
C
LO
C
R
E
T
N
U
O
C
BACK FOCUS
ADJUSTMENT
BACK FOCUS
ADJUSTMENT
RING
C
Figure 6. Back Focus Adjustment
E
IS
W
K
C
LO
LOCKING SCREW
Pelco Manual C1982M-A (12/00) [ 11 ]
SWITCH SETTINGS
WHITE REPRESENTS
SWITCH POSITION
10
9
8
7
6
5
4
3
2
1
Figure 7. Switch Settings
10 LL/INT Synchronization Selection
Locks the frame rate to the power supply frequency. Eliminates vertical
roll caused by multiple cameras connected to the same switching device. Each camera output is synchronized to the frequency of the power
supply. Set the camera synchronization mode to one of the following:
Line Lock (LL) - Line-locks frame rate of cameras.
INT - Disables line lock.
9 Lens Mode Selector (AI/DD Switch)
The AI/DD switch setting is determined by the type of lens used:
AI - Auto iris lens
DD - Direct drive lens
10
LL
10
INT
9
AI
9
DD
8 Sharpness OFF/Sharpness SHP
This switch can be used to enhance detail in the image. Set the switch to
SHP to enhance the sharpness of the edges of the objects in the picture.
7 Gamma LO/Gamma HI
Two different gamma correction options are available:
Gamma HI - Linear response.
Gamma LO - Increases visibility in dark areas of the picture.
6 AGC HI/AGC NORM
This switch sets the AGC (Automatic Gain Control) feature of the camera.
Two settings are available. Selecting AGC HI will allow the camera’s AGC
circuit to apply more gain to the video signal but may result in slightly
more noise in the picture.
5 AGC OFF/AGC ON
Automatically adjusts the image to compensate for low light levels when
using fixed or manual iris lenses.
ON - Enables the AGC mode.
OFF - Disables the AGC mode.
[ 12 ] Pelco Manual C1982M-A (12/00)
8
OFF
8
SHP
7
HI
7
LO
6
HI
6
NORM
5
AGC
5
OFF
4 EI ON/EI OFF (Electronic Iris)
The EI (Electronic Iris) feature compensates for an excessive light level by automatically adjusting
shutter speed. When the EI is ON, the DD lens level potentiometer on the side of the camera may
be used to adjust the EI threshold level. The level is factory set to 1V peak-to-peak.
OFF - Disables the Electronic Iris mode. Use with auto iris/direct
drive lenses.
ON (Default setting) - Enables the Electronic Iris mode. Use with
4
OFF
4
EI
fixed or manual iris lenses.
3 and 2 BLC - Backlight Compensation
Use the BLC (Backlight Compensation) when a bright light source is behind the subject of interest.
If a strong background light such as a window exists, the camera will compensate by reducing the
overall exposure, making the areas surrounding the window too dark. Use the BLC feature to control the exposure of the scene.
Typically, the image in the center of the picture is used to calculate the exposure. The edges
where strong backlighting is likely to be are ignored.
BLC will function with a manual iris lens when the Electronic Iris feature is switched ON. For direct drive and auto iris lenses, BLC will still function even though the Electronic Iris feature is
switched OFF.
Three active zones are available when setting the Backlight Compensation mode. The lighting
from within the selected BLC active zone (the dark areas in Figure 8) is used to calculate the
scene exposure. To select a zone:
1. Set the WND ON/OFF switch to ON. This will superimpose the selected zone onto the monitor.
2. Use switches 3 and 2 to select one of the BLC active zones (refer to Figure 8).
3. Set the overlay window switch to OFF.
OFF
3
2
= BLC Active Zone -The area used to calculate picture exposure.
3
2
Figure 8. BLC Setup Switches
1 WND ON/WND OFF - BLC Setup Window
This switch allows you to turn the BLC window video overlay on or off.
The overlay is used in conjunction with switches 8 and 9 as an aid to
setting the Backlight Compensation feature.
3
2
1
WND
1
OFF
Pelco Manual C1982M-A (12/00) [ 13 ]
3
2
CAMERA PHASE ADJUSTMENT
When using one AC power supply in a multi camera system, a brief vertical roll may occur on the
monitor each time a camera view is switched. To eliminate vertical roll, adjust the phase control to
synchronize (line-lock), the cameras to one another. The synchronization switch (DIP switch 10) for
each camera must be set to LL. Use the potentiometer located on the side of the camera to make
adjustments.
It may be necessary to have two people in communication when adjusting the phase of the camera.
One person at the camera and another person at the monitor to observe the vertical roll and the effect of any adjustments made to the camera.
To synchronize the cameras do the following:
1. Choose a reference camera to which all other cameras will be phased.
2. Select a camera and synchronize it to the reference camera by turning the phase adjustment
control clockwise and/or counterclockwise.
3. Each time an adjustment is made, switch back and forth between the camera you are adjusting
and the reference camera. Repeat this process as many times necessary, until the roll between
the cameras is no longer noticeable.
4. Adjust the phase of all other cameras by repeating steps 2 through 3. Always adjust to the reference camera selected in step 1.
NOTE: The preferred method for camera phase adjustment is to use a dual trace oscilloscope to
align the vertical sync pulses of the reference camera to the selected camera(s).
[ 14 ] Pelco Manual C1982M-A (12/00)
SPECIFICATIONS
GENERAL
CCD Sensor:1/3-inch
Synchronization System: AC line lock or internal oscillator
Horizontal Resolution
MC3500S-2:380 TV lines
MC3600H-2:570 TV lines
Iris Control:Electronic/passive
Minimum Illumination
MC3500S-2:0.1 lux at f1.2
MC3600H-2:0.05 lux at f1.2
Signal-to-Noise Ratio52 dB (AGC Off)
Gain Control:Automatic
Vertical Phase:Adjustable 0° ±120°
Automatic Gain Control:Selectable by DIP switch setting
Backlight Compensation: Selectable by DIP switch setting
Scanning System525 lines, 2:1 interface
Auto Iris Lens Type:DC/video control
Video Output:1 Vp-p, 75 ohms
Iris Control Range1/60 - 1/100,000 second
ELECTRICAL
Power Requirements:14-30 VAC
Power Connector:2-pin terminal strip, push-in type
Video Connector:BNC
Lens Jack:4-pin connector (miniature square)
Power Consumption:Less than 4 watts
MECHANICAL
Lens MountC/CS mount (adjustable)
Camera MountUse 1/4-20 screw, top or bottom of camera housing
ENVIRONMENTAL
Operating Temperature:14° to 122°F (-10° to 50°C)
Storage Temperature:14° to 158°F (-10° to 70°C)
PHYSICAL
Dimensions:2.48 (W) x 2.67 (H) x 4.33 (D) inches (6.3 x 6.8 x 11 cm)
Weight (without lens):0.77 lb (0.35 kg)
(Design and product specifications subject to change without notice.)
11-40 VDC
Pelco Manual C1982M-A (12/00) [ 15 ]
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of
shipment.
Exceptions to this warranty are as noted below:
• Five years on FT/FR8000 Series fiber optic products.
• Three years on Genex
• Three years on Camclosure® and fixed camera models, except the CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and
MC3651H-2X camera models, which have a five-year warranty.
•Two years on standard motorized or fixed focal length lenses.
•Two years on Legacy
•Two years on Spectra
•Two years on Esprit
• Eighteen months on DX Series digital video recorders, NVR300 Series network video recorders, and Endura™ Series distributed network-based video
products.
• One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.
• Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight
prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this
warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s
liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products
shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential
damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state
to state.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and
provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written
explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization
number (CA number if returned for credit, and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate
address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the
following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
®
Series products (multiplexers, server, and keyboard).
®
, CM6700/CM6800/CM9700 Series matrix, and DF5/DF8 Series fixed dome products.
®
, Esprit®, ExSite™, and PS20 scanners, including when used in continuous motion applications.
®
and WW5700 Series window wiper (excluding wiper blades).
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors
473 Eccles Avenue
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco.