5. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
6. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus
(including amplifiers) that produce heat.
7. Only use attachments/accessories specified by the manufacturer.
8. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the
apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid
injury from tip-over.
9. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been
damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or
objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not
operate normally, or has been dropped.
10. Installation should be done only by qualified personnel and conform to all local codes.
11. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is
designed for indoor use only and it must not be installed where exposed to rain and moisture.
12. Use only installation methods and materials capable of supporting four times the maximum
specified load.
13. Use stainless steel hardware to fasten the mount to outdoor surfaces.
14. To prevent damage from water leakage when installing a mount outdoors on a roof or wall, apply
sealant around the bolt holes between the mount and mounting surface.
15. CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce
the risk of electric shock do not perform any servicing other that contained in the operating
instructions unless you are qualified to do so.
16. Only use replacement parts recommended by Pelco.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage
constituting a risk of electric shock is present within
this unit.
This symbol indicates that there are important
operating and maintenance instructions in the
literature accompanying this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
2C3429M-A (1/08)
Regulatory Notices
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However there is no guarantee that the interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and the receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
•Consult the dealer or an experienced radio/TV technician for help.
You may also find helpful the following booklet, prepared by the FCC: “How to Identify and Resolve
Radio-TV Interference Problems.” This booklet is available from the U.S. Government Printing Office,
Washington D.C. 20402.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment
can void your authority to operate this equipment under Federal Communications Commission’s rules.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
The materials used in the manufacture of this document and its components are compliant to the
requirements of Directive 2002/95/EC.
This equipment contains electrical or electronic components that must be recycled properly to
comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical
and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this
equipment.
C3429M-A (1/08)3
Description
The 310 Series Camclosure® integrated camera system is a track-light design that mounts to a wall or
ceiling. The system incorporates a camera and lens package into a small, unobstructive, medium-security
enclosure designed for areas subject to vandalism. The system is quick and easy to install in a variety of
indoor or outdoor applications. It is ideal for residential, office, mall, hospital, school, parking garage,
correction and detention, and other medium-security installations subject to vandalism.
PARTS LIST
The following parts are supplied:
Qty Description
1Camclosure integrated camera system
1Hollow screwdriver bit (1/8-inch)
4C3429M-A (1/08)
Installation
PREPARE WALL OR CEILING
Prepare the wall or ceiling according to one of the following options.
•Mounting directly to wall or ceiling
Figure 1. Wall/Ceiling Mounting
•Mounting to a 4S electrical box with 404 plaster ring
4S ELECTRICAL BOX
WALL OR
CEILING
ICS310-AP
ADAPTER
PLATE (NOT
SUPPLIED)
6-32 X 0.50 SECURITY SCREW
(SUPPLIED WITH ADAPTER PLATE)
WALL OR
CEILING
404 PLASTER RING
Figure 2. Mounting to a 4S Electrical Box
•Mounting to ICS310-COND conduit adapter (not supplied)
WALL OR
CEILING
CONDUIT
ADAPTER
Figure 3. Conduit Mounting
C3429M-A (1/08)5
•Mounting to a 2-gang electrical box
2-GANG ELECTRICAL BOX
WALL OR
CEILING
ICS310-AP
ADAPTER
PLATE (NOT
SUPPLIED)
6-32 X 0.50 SECURITY SCREW
(SUPPLIED WITH ADAPTER PLATE)
Figure 4. Mounting to a 2-Gang Electrical Box
CONNECT VIDEO AND POWER
1. Some indoor installations do not require a heater. If the installation does not require a heater,
disconnect the heater wiring.
a.Remove the cover with the supplied 1/8-inch hollow screwdriver bit.
b.Remove the camera from the mounting bracket, and unplug the 4-pin heater connector in the
base.
c.Reinstall the camera. If the camera has a varifocal lens, leave the cover off; it will be
reinstalled later. Otherwise, reinstall the cover.
2. Connect the power input wires to the power wires of the IS310 base (refer to Table A).
Tab le A . Power Input
Voltage Red Wire Black Wire
12 VDC + Ground
24 VAC ~ ~
3. Connect the video cable/wires:
•BNC: Connect the BNC connector from the unit to a mating BNC connector.
•UTP: Connect the blue wire to Video +; connect the gray wire to Video -.