6. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
7. Only use attachments/accessories specified by the manufacturer.
8. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such
as vases shall be placed on the apparatus.
9. Installation should be done only by qualified personnel and conform to all local codes.
10. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is
designed for indoor use only and it must not be installed where exposed to rain and moisture.
11. Use only installation methods and materials capable of supporting four times the maximum
specified load.
12. Use stainless steel hardware to fasten the mount to outdoor surfaces.
13. Only use replacement parts recommended by Pelco.
14. After replacement/repair of this unit’s electrical components, conduct a resistance measurement
between the line and exposed parts to verify the exposed parts have not been connected to the line
circuitry.
Open Source Software Notice
This product includes certain open source or other software originated from third parties that is subject to
the GNU General Public License (GPL), GNU Library/Lesser General Public License (LGPL), and different
and/or additional copyright licenses, disclaimers, and notices.
The exact terms of GPL, LGPL, and some other licenses are provided to you with this product. Please refer
to the exact terms of the GPL and LGPL at http://www.fsf.org (Free Software Foundation) or
http://www.opensource.org (Open Source Initiative) regarding your rights under said license. You may
obtain a complete corresponding machine-readable copy of the source code of such software under the
GPL or LGPL by sending your request to digitalsupport@pelco.com; the subject line should read Source
Code Request. You will then receive an e-mail with a link for you to download the source code.
This offer is valid for a period of three (3) years from the date of the distribution of this product by Pelco.
4C2941M-C (6/08)
Regulatory Notices
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However there is no guarantee that the interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and the receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
•Consult the dealer or an experienced radio/TV technician for help.
You may also find helpful the following booklet, prepared by the FCC: “How to Identify and Resolve
Radio-TV Interference Problems.” This booklet is available from the U.S. Government Printing Office,
Washington D.C. 20402.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment
can void your authority to operate this equipment under Federal Communications Commission’s rules.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
C2941M-C (6/08)5
Description
The IP3701H-2 Series is a high resolution, color video camera with a built-in 100Base-TX network interface
for live streaming to a standard Web browser (Microsoft
features open architecture connectivity for third-party software recording solutions and is also Endura
™
Enabled
to record, manage, configure, and view multiple live streams.
The camera also includes built-in Power over Ethernet (PoE), which supplies power to the camera through
the network. If PoE is not available, the camera is prewired for 24 VAC.
Before installing your camera, thoroughly familiarize yourself with the information in this manual.
®
Internet Explorer® or Firefox®). The camera
MODELS
IP3701H-2
IP3701H-2XHigh resolution, 470 TV lines, SuperHAD CCD, minimum illumination of 0.5 lux at f/1.2 and
High resolution, 480 TV lines, SuperHAD
40 IRE, NTSC
40 IRE, PAL
™
CCD, minimum illumination of 0.5 lux at f/1.2 and
6C2941M-C (6/08)
Basic System Configurations
3rd PARTY
RECORDING SOLUTION
TCP / IP / INTERNET
IMPORTANT NOTE. PLEASE READ. The network implementations in this document are shown as
general representations only and are not intended to show detailed network topologies. Your actual
network will differ, requiring changes or perhaps additional network equipment to accommodate the
systems as illustrated. Please contact your local Pelco Representative to discuss your specific
requirements.
CABLE MODEM ROUTER / SWITCH
WITH DHCP SERVER
TCP / IP / INTERNET
WEB
BROWSER
DHCP NETWORK
CAMERA
CAMERA
3rd PARTY
RECORDING SOLUTION
NOTE: FOR A SECURE NETWORK, PELCO RECOMMENDS
PLACING THE IP3701H CAMERA BEHIND A FIREWALL
Figure 1. DHCP Network Example
ENDURA
C2941M-C (6/08)7
WEB
BROWSER
Figure 2. Endura
®
Network Example
CAMERA
NETWORK SWITCH
3rd PARTY
RECORDING SOLUTION
TCP / IP / INTERNET
CAMERA
WEB
BROWSER
PRIVATE NETWORK
PC ACTS AS SERVER
TCP / IP / INTERNET
WEB
BROWSER
Figure 3. Private Network Example
CABLE MODEM ROUTER / SWITCH
(DHCP SERVER DISABLED)
IF NOT DHCP, CAMERA IS ASSIGNED
DEFAULT IP ADDRESS 192.168.0.20 ON
NETMASK 255.255.0.0
CAMERA
CAMERA 1 FIXED BUT
UNIQUE IP ADDRESS;
SAME SUBNET MASK
CAMERA
CAMERA
3rd PARTY
RECORDING SOLUTION
AS COMPUTER
CAMERA 2 FIXED BUT
UNIQUE IP ADDRESS;
SAME SUBNET MASK
AS COMPUTER
STAT IC NETWORK
(FIXED BUT UNIQUE IP ADDRESS;
SAME SUBNET MASK AS CAMERAS)
NOTE: FOR A SECURE NETWORK, PELCO RECOMMENDS
PLACING THE IP3701H SERIES CAMERA BEHIND A FIREWALL.
Figure 4. Static Network Example
8C2941M-C (6/08)
Loading...
+ 16 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.