Pelco ICISA6500 User Manual

ICISA6500
®
Inter-Check
Interface Cable
Installation/Operation Manual
C1053M (7/98)
1.0 WARNINGS Prior to installation and use of this product, the following WARNINGS should be
observed.
2. Only use replacement parts recommended by Pelco.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of elec­tric shock is present within this unit.
This symbol indicates that there are important operating and mainte­nance instructions in the literature accompanying this unit.
Please thoroughly familiarize yourself with the information in this
Pelco • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • www.pelco.com In North America and Canada: Tel (800) 289-9100 • FAX (800) 289-9150
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120
manual prior to installation and operation.
2.0 DESCRIPTION The ICISA6500 is an Inter-Check
register.
®
interface cable for the Samsung 6500 cash
3.0 INSTALLATION 1. Make sure you have the following equipment before you begin the installation:
1 ICI1000S or ICI2000D Inter-Check® Register Interface 1 ICI1000WK or ICI2000WK Wiring Kit 1 ICISA6500 Interface Cable for each register
NOTE:
If you have an ICI2000D in­terface and two registers, the instruc­tions apply to both registers.
NOTE:
To receive data from the Samsung 6500, the protocol must be reset to RS-232 STANDARD PRINTER and the communication parameters must be set for DATA NON-INVERTED. (Executing a PIM Default Load does not auto­matically set the channel param­eters to the values listed in Table B.)
2. Connect a coaxial cable between the port labeled VIDEO OUT on the Inter­Check® and a CCTV monitor. Connect a coaxial cable between your camera and the port labeled VIDEO IN on the Inter-Check type of video coaxial cable to use.
®
. Refer to Table A for the
Table A. Video Coaxial Cable Requirements
Cable Type* Maximum Distance
RG59/U 750 ft (229 m)
RG6/U 1,000 ft (305 m)
RG11/U 1,500 ft (457 m)
* Minimum cable requirements:
75 ohms impedance All-copper center conductor All-copper braided shield with 95% braid coverage
3. Power up all units.
4. In the programming mode on the Inter-Check®, go to the DIAGNOSTICS MENU and select the (DL) PIM DEFAULT LOAD option. (Refer to the proper ICI1000S or ICI2000D manual for menu programming instructions.)
It is best to enable the Default Load option even if your installation does not require a PIM module. The Default Load sets all Inter-Check® communication parameters to the specific values needed to communicate with the ICI1000PIM module.
5. When the prompt “SYSTEM INITIALIZED” appears on the monitor, return to the PROGRAMMING MENU and set the data protocol for RS-232 STANDARD PRINTER and communication parameters to DATA NON-INVERTED. (Refer to Table B for the Inter-Check® communication parameters for the Samsung
6500.)
Table B. Inter-Check® Default Communication Parameters
Communication Parameters Protocol
9600 BAUD RS-232 STANDARD PRINTER 8 BITS NO PARITY NRZ ASCII DATA NON-INVERTED
6. Turn off and unplug the cash register.
7. Connect the ICISA6500 interface cable into an available Com Port on your cash register. Com 1 is preferred but you can also use Com 2. (Refer to Figure 1.)
8. Wire the ICISA6500 to the Inter-Check®, as shown in your ICI1000S or ICI2000D manual, using the wiring kit diagram appropriate for RS-232 com­munication.
2 Pelco Manual C1053M (7/98)