IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P enclo­sure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
4. The installation method and materials should be capable to supporting four times the weight of the enclosure, pan/tilt, camera and lens combination.
5. The camera and lens combination shall not exceed 20 pounds (9.06 kg).
The product and/or manual may bear the following marks:
This symbol indicates that danger­ous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and mainte­nance instructions in the literature accompanying this unit.
Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
DESCRIPTION
The HS4100BH is a high-security camera enclosure designed to be mounted in indoor walls in applications requiring maximum protection from vandalism, such as prisons and detention cells.
There is no exposed mounting hardware holding the enclosure to its mounting surface be­cause the HS4100BH replaces a half-size concrete block during construction of the wall. The HS4100BH is made of heavy-gauge steel and is equipped with a window of 1/2-inch (1.27 cm) thick, impact-resistant Lexan®.
The HS4100BH accepts most CCD cameras with fixed focal length lenses and some motor­ized zoom lenses. Access to the inside is through the front or rear with a specially designed tool, so the enclosure cannot be opened by unauthorized people. In addition, a factory-in­stalled tamper switch is mounted on the secured access cover.
INSTALLATION
The following parts are supplied:
1 Enclosure 1 Tampruf #10 socket, 1/4-inch drive
The HS4100BH is designed to be installed in a concrete block wall during construction. The enclosure’s dimensions allow it to replace a half-size block.
Before installing the HS4100BH enclosure in a wall, make certain the wall detail and construc­tion can support the full weight of the enclosure plus the camera and lens. The HS4100BH must not be considered a structural component in a wall. Make sure during construction that the access panels are not obstructed by mortar.
After incorporating the enclosure into the wall structure, follow the steps below to complete the installation.
1. Remove the appropriate knock-outs and route the required cables to the enclosure.
2. You can access the inside of the enclosure from either the front or rear. Use the supplied Tampruf #10 socket (fits 1/4-inch square drive).
• The hinged front swings down after you remove the two Tampruf screws.
• The rear plate comes off after you remove the four Tampruf screws.
3. The tamper switch comes with normally open and normally closed contacts. To wire the tamper switch:
• For a normally open circuit, use the OPEN and COMMON terminals.
• For a normally closed circuit, use the CLOSED and COMMON terminals.
4. Mount the camera and lens to the tilt table.
5. Make all appropriate connections (for example, camera power, video, and lens).
6. Position the camera and tighten the 1/4-20 fasteners to secure the tilt table in the desired position.
7. Close the cover (or replace the rear plate) and check that all components clear. Secure with the 1/4-20 Tampruf screws.
MAINTENANCE
Performing maintenance at regular intervals will help prolong the equipment’s operational life and appearance. Regularly clean the Lexan® window with a mild non-abrasive detergent in water and a soft cloth to help keep the picture clear. For a very dirty window, use vinyl cleaner.
SPECIFICATIONS
MECHANICAL
Window: 1/2-inch (1.27 cm) thick impact and abrasion resistant Lexan
Window Viewing Area: 3.50 in. H x 4.00 in. W (8.89 x 10.16 cm)
Camera Mounting: Adjustable tilt table
Maximum Camera/Lens Size: Accepts camera and lens combinations (including BNC connector) up to:
8.0 in. L x 6.0 in. W x 6.0 in. H (20.32 x 15.24 x 15.24 cm)
Enclosure Mounting: Replaces half-size concrete block during wall construction
Security: Tamper-resistant screws. N.O./N.C. switch contact on secure cover
ELECTRICAL
Cable Entry: Two cable knock-out holes on the rear plate for 1/2-inch (1.27 cm) diam-
eter conduit
Tamper Switch: Plunger-type switch with “pull to cheat” feature. 1/4-inch (0.63 cm) quick
connect. N.O./N.C. clearly marked on switch body. 10 A maximum switch­ing current, 125 V maximum switching voltage.
®