Pelco HS4000TWR, HS4000TWL User Manual

®
HS4000TW Series
High-Security Camera Enclosure
Installation/Operation Manual
C492M-D (1/96)
Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 • USA • www.pelco.com
(800) 289-9100 or (1-559) 292-1981 • FAX (800) 289-9150 or (1-559) 292-3827
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120
TABLE OF CONTENTS
Section Page
1.0 WARNINGS ........................................................................................................................................1
2.0 SCOPE ............................................................................................................................................... 2
3.0 DESCRIPTION ................................................................................................................................... 2
3.1 MODELS ..................................................................................................................................2
4.0 SPECIFICATIONS .............................................................................................................................. 3
5.0 INSTALLATION .................................................................................................................................. 4
5.1 WALL/CEILING MOUNTING ....................................................................................................4
5.2 TAMPER SWITCH INSTALLATION .......................................................................................... 4
5.3 TAMPER SWITCH WIRING .....................................................................................................4
6.0 CARE AND MAINTENANCE .............................................................................................................. 5
7.0 EXPLODED ASSEMBLY DIAGRAM ..................................................................................................6
8.0 MECHANICAL PARTS LIST FOR HS4000TW SERIES ENCLOSURE .............................................6
9.0 WARRANTY AND RETURN INFORMATION.....................................................................................9
LIST OF ILLUSTRATIONS
Figure Page
1 HS4000TW Series Dimension Drawing ..........................................................................................3
2 HS4000TW Series Tamper Switch Installation................................................................................5
3 HS4000TW Series Enclosure Exploded Assembly Diagram .......................................................... 6
Revision History
Manual # Date Comments
C492M 5/90 Original manual. C492M 9/92 Rev. A. Cable entry information revised. C492M-B 9/95 Rev. B. Revised to include wiring instructions for tamper switch and
metric equivalents for specifications.
C492M-C 11/95 Rev. C. Revised to include updated tamper switch/bracket part numbers
and exploded view diagram.
C492M-D 1/96 Rev. D. Revised to include tamper switch installation, specification
description and new part numbers per ECO 95-397.
11/96 Revised to include updated mechanical parts list and exploded assembly
diagram.
Pelco, the Pelco Logo, Camclosure, Esprit, Genex, Legacy, and Spectra are registered trademarks of Pelco. © Copyright 1996, Pelco. All rights reserved. Endura and ExSite are trademarks of Pelco.
ii
INSTALLATION/OPERATION MANUAL HS4000TW SERIES HIGH-SECURITY CAMERA ENCLOSURES
1.0 WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
The product may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present
within this unit.
4. The installation method and materials should be capable of supporting four (4) times the weight of the enclosure, pan/tilt, camera and lens combination.
5. The camera and lens combination shall not exceed 20 lbs (9.06 kg).
This symbol indicates that there are important operating and maintenance instructions in the
literature accompanying this unit.
CAUTION:
TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER. NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
RISK OF ELECTRIC SHOCK.
CAUTION:
DO NOT OPEN.
Please thoroughly familiarize yourself with the information in this manual
prior to installation and operation.
Pelco Manual C492M-D (1/96) 1
2.0 SCOPE
3.1 MODELS
The information within this manual covers the installa­tion of the HS4000TW Series High Security Camera Enclosure.
Please thoroughly familiarize yourself with the infor­mation in this manual prior to installation and opera­tion.
3.0 DESCRIPTION
The HS4000TW Series high security camera enclosure is designed for indoor “through the wall” installation for such applications as prisons, detention cells, etc., requiring maximum protection from vandalism.
The HS4000TW is available in three (3) configurations: tilt down, straight angle (HS4000TWS); tilt down, right angle (HS4000TWR); and tilt down, left angle (HS4000TWL). Designed to function either as a wall or ceiling enclosure, the wide heavy gauge mounting flange ensures secure mounting. Access to the interior can be gained through the front or rear with a specially designed tool, eliminating the possibility of the enclo­sure being opened by unauthorized personnel. In addi­tion, a factory-installed tamper switch is mounted on the secured access cover.
HS4000TWS High security ceiling/wall enclo-
sure with tilt down, straight viewing angle constructed of heavy gauge steel, designed for installations such as prisons, de­tention cells, etc., requiring maximum protection from van­dalism. (UL)
HS4000TWR Same as HS4000TWS except
with tilt down, right viewing angle.
HS4000TWL Same as HS4000TWS except
with tilt down, left viewing angle. (UL)
Constructed of heavy gauge steel, the HS4000TW Se­ries will accept most CCD cameras with fixed focal length lenses ranging in size from 4 mm to 75 mm.
4.0 SPECIFICATIONS
ELECTRICAL
MECHANICAL
Window: 1/2" (1.27 cm) thick impact and
abrasion resistant Lexan
Camera Mounting: Multiple holes on camera sled
Maximum Camera/Lens Size: Accepts camera/lens combina-
tions (including BNC connector) up to:
15.0" L x 6.0" W x 4.75" H (38.10 cm x 15.24 cm x 12.06 cm)
Enclosure Mounting: Eight (8) .390" diameter holes
in 10" x 10" flange
Security: Tamper-resistant screws N.O./
N.C. switch contact on cover
Tamper Switch: Plunger type door switch with
“pull to cheat” feature. N.O./ N.C. contacts clearly marked on body of switch. DM electrical rating: 10A, 125V. Plunger type with .20" (0.51 cm)
Cable Entry: Two (2) cable knock-out holes
on rear plate
Tamper Switch: 1/4" (.63 cm) quick connect.
N.O./N.C. clearly marked on switch body. 10A, maximum switching current 125V, maxi­mum switching voltage.
GENERAL
Construction: Seam welded 10 gauge .134"
(0.34 cm) steel
Finish: Poly vinyl powder coat
Dimensions: See Figure 1
Environment: Indoor; 32° to 120° F
(0° to 48.89° C)
Unit Weight: 24 lbs (10.87 kg)
Figure 1. HS4000TW Series Dimension Drawing
Pelco Manual C492M-D (1/96) 3
5.0 INSTALLATION
5.2 TAMPER SWITCH INSTALLATION
Before installing the HS4000TW Series enclosure in a wall or ceiling, make certain that the mounting surface is able to support the full weight of the enclosure plus the camera and lens.
NOTE: The eight (8) fasteners required to se­cure the HS4000TW Series enclosure to a wall or ceiling (minimum 3/8” diameter recom­mended) are not supplied.
5.1 WALL/CEILING MOUNTING
To mount the enclosure to a wall or ceiling, perform the following steps:
1. Using the template supplied, mark the hole loca­tions and area to be cut out.
2. Drill mounting holes and cut wall/ceiling for en­closure body. Note the angle of the enclosure in relation to the mounting flange and remove suffi­cient material behind the wall to clear.
3. Insert the enclosure into the opening and attach with the required fasteners.
The HS4000TW High-Security enclosures come stanmdard from the factory with a tamper switch mounted on the secure access cover.
Should it become necessary to install a replacement switch, reference Figure 2 and perform the following steps:
1. Open the enclosure by removing the end plate from the desired “alarmed” opening.
2. Install the bracket so that the mounting studs go through the slots in the bracket.
NOTE: The slot in the bracket allows the switch to be used against either the 1/2" (1.27 cm) thick lexan window or the .134" (0.34 cm) thick metal plate.
3. If the switch is to be used against the metal plate, slide the bracket so that the studs are at the end of the slot that is furthest from the switch plunger.
4. If the switch is to be used against the Lexan win­dow, slide the bracket so that the studs are at the end of the slot nearest the switch plunger.
4. Install conduit fittings (not supplied) into holes on rear access plate and run required wiring through fittings.
5. Access to the interior of the enclosure can be gained from either the front (window) or rear by remov­ing the end plates. The end plates are secured by four (4) 1/4-20 “Tampruf” screws (four (4) each end). A special socket is provided (fits 1/4” square drive). The end plates are symmetrical and may be swapped end for end depending on the installation.
6. Remove the camera sled from the enclosure. Mount the camera/lens to the sled.
7. Make all appropriate connections (i.e., camera power, video (coax), and lens).
8. Replace the camera/lens/camera sled assembly back into the enclosure and tighten the 1/4-20 screw to secure the sled in place.
9. Replace the end plate(s) and check that all compo­nents clear. Secure with the 1/4-20 “Tampruf” screws provided.
5. When reinstalling the front/rear plate, position the plate flush with the end of the enclosure body.
5.3 TAMPER SWITCH WIRING
The tamper switch comes with both a “Normally Open” and a “Normally Closed” contact.
For a “Normally Open” circuit, use the “open” and “common” terminals; for a “Normally Closed” circuit, use the “closed” and “common” terminals.
6.0 CARE AND MAINTENANCE
Maintenance performed at regularly scheduled inter­vals will help prolong the operational life and appear­ance of the equipment.
Clean the Lexan window with a mild non-abra­sive detergent in water and a soft cloth regularly to help maintain picture clarity. For a heavily soiled window, use vinyl cleaner.
NOTE: Pelco offers a 24-hour, seven-day-a week Technical Assistance Program (TAP) de­signed to assist any customer with a technical problem involving Pelco equipment whether it’s the weekend or late at night. For technical as­sistance dial (800) 289-9100 and you will be connected to a Pelco TAP member who is trained to answer your questions.
Pelco also guarantees one-day turnaround on any Pelco equipment sent in for repair. This includes warranty and non-warranty items. Refer to the section on “Warranty and Return Information” in this manual for the proper pro­cedure.
Figure 2. HS4000TW Series Tamper Switch Installation
Pelco Manual C492M-D (1/96) 5
7.0 EXPLODED ASSEMBLY DIAGRAM
See Figure 3 for exploded assembly diagram of HS4000TW Series enclosure.
Figure 3. HS4000TW Series Enclosure Exploded Assembly Diagram
8.0 MECHANICAL PARTS LIST FOR HS4000TW SERIES ENCLOSURE
Item No. Qty Description Part Number
1 1 Window, Lexan, 5.75" x 4" x 0 .5", MR5 AH800010001 2 1 Weld Assembly (HS4000TWS) HS4000STR1000WA
Weld Assembly (HS4000TWL) HS4000LFT1000WA
Weld Assembly (HS4000TWR) HS4000RHT1000WA 3 2 Plate, Front/Rear HS40004003COMP 4 1 Sled EH40144001COMP 5 1 Plate, Blank/Knock-Out HS40004015COMP 6 2 Bracket, Switch, Break-In HS30004113COMP 7 2 Switch, Tamper SWI1DM401 8 8 Screw, 1/4-20x1/2", Rnd, Tampruf#10, SS ZH1/4-20X.50SRT 9 1 Socket, Tampruf #10, 1/4" Drive (not shown) ZTSOCKET10
A 4 1/4-20 Nut-Lock ZH1/420NUTCHN B 16 1/4" Flat Washer ZH260X562X65C C 1 1/4-20 x 1.25" Screw ZH1/420X1.25CS D 4 1/4" Split Lock Washer ZH1/4LWSSL E 4 1/4-20 Hex Nut ZH1/4-20NUTCH
F 4 #6 Lock Washer ZH6LWSIS
G 4 6-32 Hex Nut ZH6-32NUTSH
HS4000TW Mounting Template
Pelco Manual C492M-D (1/96) 7
(This page intentionally left blank.)
9.0 WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
• Five years on FT/FR8000 Series fiber optic products.
• Three years on Genex
keyboard).
• Three years on Camclosure
CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models, which have a five-year warranty.
• Two years on standard motorized or fixed focal length lenses.
• Two years on Legacy
DF5/DF8 Series fixed dome products.
• Two years on Spectra®, Esprit®, ExSite™, and PS20 scanners, includ-
ing when used in continuous motion applications.
• Two years on Esprit® and WW5700 Series window wiper (excluding
wiper blades).
• Eighteen months on DX Series digital video recorders, NVR300
Series network video recorders, and Endura network-based video products.
• One year (except video heads) on video cassette recorders (VCRs).
Video heads will be covered for a period of six months.
• Six months on all pan and tilts, scanners or preset lenses used in
continuous motion applications (that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state. If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice
number
3. Details of the defect or problem If there is a dispute regarding the
warranty of a product which does not fall under the warranty conditions stated above, please include a written explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
®
Series products (multiplexers, server, and
®
and fixed camera models, except the
®
, CM6700/CM6800/CM9700 Series matrix, and
Series distributed
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico, send goods to:
Service Department Pelco 3500 Pelco Way Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico and are instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco 3500 Pelco Way Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors 473 Eccles Avenue South San Francisco, CA 94080 USA Phone: 650-737-1700 Fax: 650-737-0933
Pelco Manual C492M-D (1/96) 9
®
World Headquarters
3500 Pelco Way
Clovis, California 93612 USA
USA & Canada
Tel: 800/289-9100
Fax: 800/289-9150
International
Tel: 1-559/292-1981
Fax: 1-559/348-1120
www.pelco.com
ISO9001
United States | Canda | United Kingdom | The Netherlands | Sinapore | Spain | Scandanavia | France
Middle East
|
10 Pelco Manual C492M-D (1/96)
Loading...