TABLE OF CONTENTS
Section Page
1.0 WARNINGS.....................................................................................................................................1
2.0 SCOPE............................................................................................................................................2
3.0 DESCRIPTION................................................................................................................................2
3.1 MODELS ...............................................................................................................................2
3.2 OPTIONS ..............................................................................................................................2
4.0 INSTALLATION ...............................................................................................................................3
4.1 CEILING MOUNTING (FLUSH) ............................................................................................3
4.2 MID-WALL MOUNTING ........................................................................................................3
4.3 WINDOW INSTALLATION.....................................................................................................3
4.4 TAMPER SWITCH INSTALLATION ......................................................................................4
4.5 TAMPER SWITCH WIRING..................................................................................................4
5.0 CARE AND MAINTENANCE ..........................................................................................................4
6.0 EXPLODED ASSEMBL Y DIAGRAM ...............................................................................................7
7.0 MECHANICAL PARTS LIST FOR HS2000 ENCLOSURE..............................................................7
8.0 SPECIFICATIONS...........................................................................................................................8
9.0 WARRANTY AND RETURN INFORMATION .................................................................................9
LIST OF ILLUSTRATIONS
Figure Page
1 HS2000 Series Tamper Switch Installation .....................................................................................4
2 HS2000 Exploded Assembly Diagram ............................................................................................7
3 HS2000 Dimension Drawing ...........................................................................................................8
REVISION HISTORY
Manual # Date Comments
C494M 5/90 Original version. C494M 9/93 Rev. A. Put into two-column format. Exploded assembly diagram and
parts list updated.
C494M-B 9/95 Rev. B. Revised to include wiring instructions for tamper switch and put
into new two-column format.
C494M-C 11/95 Rev. C. Revised to include updated tamper switch/bracket part numbers
and exploded view diagram.
C494M-D 1/96 Rev. D. Revised to include tamper switch installation, specification
description and new part numbers per ECO 95-397.
4/96 Revised Section 7.0, item no. 1 to part number HS10004313COMP.
12 Pelco Manual C494M-D (1/96)
ii
INSTALLATION/OPERATION MANUAL HS2000 SERIES HIGH SECURITY ENCLOSURE
1.0 WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by Qualified Service Personnel and conform to all Local codes.
2. Unless the unit is specifically marked as a NEMA T ype 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is de­signed for indoor use only and it must not be in­stalled where exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
The product may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present
within this unit.
4. The camera and lens combination shall not exceed 20 lbs (9.06 kg).
5. The installation method and materials should be capable of supporting four (4) times the weight of the enclosure, pan/tilt, camera and lens combina­tion.
This symbol indicates that there are important operating and maintenance instructions in the
literature accompanying this unit.
CAUTION:
TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER. NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
RISK OF ELECTRIC SHOCK.
CAUTION:
DO NOT OPEN.
Please thoroughly familiarize yourself with the information in this manual
prior to installation and operation.
Pelco Manual C494M-D (1/96) 1
2.0 SCOPE
3.1 MODELS
The information within this manual covers the installa­tion of the HS2000 High Security Camera Enclosure.
3.0 DESCRIPTION
The HS2000 high security camera enclosure is designed for indoor “corner mount” installation for such appli­cations as elevators, parking garages, classrooms, of­fices, detention cells, etc., requiring maximum protec­tion from vandalism in an unobtrusive package. De­signed to fit flush to the ceiling in a corner, an optional hood (HS2000H) allows the HS2000 to be mounted lower on the wall and still retain the enclosure’s integ­rity. An impact-resistant clear Lexan window is sup­plied, an optional smoked window is available.
Constructed of medium gauge steel, the HS2000 will accept many of the smaller CCD cameras with fixed focal length and auto-iris lenses. There is no exposed mounting hardware securing the HS2000 to its mount­ing surface. Opening the enclosure can only be accom­plished by removing the tamper-resistant screw from the bottom. In addition, a factory-installed tamper switch is mounted on the secured access cover.
HS2000 High security corner mount enclo-
sure designed to fit flush with the ceiling. For use in applications such as elevators, parking garages, classrooms, offices, detention cells, etc., requiring maximum pro­tection from vandalism in an un­obtrusive package.
HS2000/BR Same as HS2000 except brass
plated finish.
HS2000/CH Same as HS2000 except chrome
plated finish.
3.2 OPTIONS
HS2000H Hood for mid-wall mounting of
HS2000 enclosure.
HS200010019 Smoked window, 1/4" (6.35 mm)
thick, impact and abrasion-resis­tant Lexan.
2 Pelco Manual C494M-D (1/96)
4.0 INSTALLATION
4.2 MID-WALL MOUNTING
Before installing the HS2000 to a wall, make certain that the mounting surface is able to support the full weight of the enclosure plus the camera and lens.
The tilt table and tilt table mounting brackets may be removed to provide adequate clearance for mounting the enclosure.
NOTE: The four (4) fasteners required to se­cure the HS2000 to a wall (minimum 3/8" di­ameter recommended) are not supplied.
4.1 CEILING MOUNTING (FLUSH)
To mount the enclosure to a wall (tight to the ceiling), perform the following steps:
1. Remove the cover from the mounting bracket. A special socket is provided (fits 1/4" square drive).
2. Using the mounting bracket or the template pro­vided, mark and drill holes in the mounting sur­face.
3. Attach the enclosure with the required fasteners.
T o mount the HS2000 enclosure mid-wall, use the op­tional hood, HS2000H, and perform the following steps:
1. Determine the position for the hood. Using it as a template, mark and drill holes in the mounting sur­face.
2. Attach the hood with the required fasteners (mini­mum 3/8" diameter recommended).
3. Continue with steps 1-8 in Section 4.1.
4.3 WINDOW INSTALLATION
The HS2000 is provided with a clear Lexan 1/4" thick viewing window. An optional smoked window, HS200010019, is available.
Instructions for installing the optional smoked window are as follows:
1. Remove the cover from the mounting bracket. A special socket is provided.
2. Remove the four (4) 1/4-20 elastic locknuts and 1/4" flat washers.
4. Route the required cables through the back or top.
5. Mount the camera/lens to the tilt table.
6. Make all appropriate connections (i.e., camera power, video (coax), lens).
7. Position the camera and tighten the 1/4-20 fasten­ers to secure the tilt table in place.
8. Replace the cover and check that all components clear. Secure with the 1/4-20 “T ampruf” screw pro­vided.
NOTE: A plate is provided to prevent access through the top of this enclosure. If needed, it is mounted with the mounting bracket using the same mounting holes and hardware.
3. Remove the window.
4. Remove the protective coatings from the new win­dow and place the window over the four (4) 1/4-20 studs.
5. Replace the hardware and replace the cover.
Pelco Manual C494M-D (1/96) 3
4.4 TAMPER SWITCH INSTALLATION
5.0 CARE AND MAINTENANCE
The HS2000 enclosures come standard from the fac­tory with a tamper switch installed. Should it become necessary to install a replacement switch, refer to Fig­ure 1 for the correct position of the bracket/switch and perform the following steps:
1. Remove the front cover.
2. Install the bracket/switch and secure with lockwashers and nuts.
4.5 TAMPER SWITCH WIRING
The tamper switch comes with both a “Normally Open” and a “Normally Closed” contact.
For a “Normally Open” circuit, use the “open” and “common” terminals; for a “Normally Closed” circuit, use the “closed” and “common” terminals.
Maintenance performed at regularly scheduled inter­vals will help prolong the operational life and appear­ance of the equipment.
1. Clean the Lexan window with a mild non-abra­sive detergent in water and a soft cloth regularly to help maintain picture clarity. For a heavily soiled window, use vinyl cleaner.
NOTE: Pelco offers a 24-hour, seven-day-a week T echnical Assistance Program (T AP) de­signed to assist any customer with a technical problem involving Pelco equipment whether it’s the weekend or late at night. For technical as­sistance dial (800) 289-9100 and you will be connected to a Pelco TAP member who is trained to answer your questions.
Pelco also guarantees one-day turnaround on any Pelco equipment sent in for repair. This includes warranty and non-warranty items. Refer to the section on “Warranty and Return Information” in this manual for the proper pro­cedure.
Figure 1. HS2000 Series Tamper Switch Installation
4 Pelco Manual C494M-D (1/96)
HS2000 Mounting Template
Pelco Manual C494M-D (1/96) 5
(This page intentionally left blank.)
6 Pelco Manual C494M-D (1/96)
6.0 EXPLODED ASSEMBLY DIAGRAM
Figure 2. HS2000 Exploded Assembly Diagram
7.0 MECHANICAL PARTS LIST FOR HS2000 ENCLOSURE
Item No. Qty Description Part Number
1 1 Bracket, Switch, Break-In HS10004313COMP 2 1 Window, 8" x 7" x .25" Drilled MR5 Clear Lexan HS200010009 3 1 Plate, Mounting HS20004001COMP 4 1 Cover, Front, Beige HS20004003COMP
Cover, Front, Brass Plated HS20004003BRCMP
Cover, Front, Chrome Plated HS20004003CHCMP 5 1 Tilt Table HS20004007COMP 6 1 Cover, Top, Corner Mount HS20004023COMP 7 1 Bracket, Mount, Tilt Table, Left HS20004115COMP 8 1 Bracket, Mount, Tilt Table, Right HS20004215COMP 9 1 Switch, Tamper SWI1DM401
A 2 Screw, 1/4-20 x 1/2", Round, Tampruf #10, SS ZH1/4-20X.50SRT B 1 Screw, 1/4-20 x 3/4", Round, Tampruf #10, SS ZH1/4-20X.75SRT C 2 Tape, Two-Sided, Acrylic x inch ZHTAPE1.00X.025 D 2 Bolt, 1/4-20 x 5/8" Hex Head C/S SS ZH1/420X.625CH E 2 Nut, Hex, 1/4-20, SS ZH1/4-20NUTCH
F 4 Washer, Split Lock, 1/4" SS ZH1/4LWSSL
G 7 Washer, Flat 3/16" Special, SS ZH260X562X65C H 4 Washer, Flat 15/16", SS ZH932X1.75X130
I 4 Nut, Lock 1/4-20 Nylon Insert, SS ZH1/420NUTCHN J 1 Socket, Tampruf #10, 1/4" Drive (not shown) ZTSOCKET10
Pelco Manual C494M-D (1/96) 7
8.0 SPECIFICATIONS
MECHANICAL
Window: 1/4" (6.35 mm) thick impact and
abrasion resistant clear Lexan
Camera Mounting: Adjustable tilt table
Maximum Camera/Lens Size: Accepts camera/lens combina-
tions (including BNC connector) up to:
3.0" H x 3.0" W x 6.0" L (7.62 cm x 7.62 cm x 15.24 cm)
Enclosure Mounting: Four (4) .390" (0.99 cm) diam-
eter holes on protected rear sur­face
Security: Tamper-resistant screw N.O./
N.C. switch contact on cover
Tamper Switch: Plunger type door switch with
“pull to cheat” feature. N.O./ N.C. contacts clearly marked on body of switch. DM electrical rating: 10A, 125V. Plunger type with .20" (0.51 cm)
ELECTRICAL
Cable Entry: Access through back and top
Tamper Switch: 1/4" (.63 cm) quick connect. N.O./
N.C. clearly marked on switch body. 10A, maximum switching current 125V, maximum switching voltage.
GENERAL
Construction: Formed 14 gauge .074" (0.19 cm)
steel
Finish: Poly vinyl powder coat
Dimensions: See Figure 3
Environment: Indoor
32° to 120° F (0° to 48.89° C)
Unit Weight: 6 lbs 6 oz (2.72 kg)
Figure 3. HS2000 Dimension Drawing
8 Pelco Manual C494M-D (1/96)
9.0 WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one (1) year after the date of shipment.
Six (6) months on all pan and tilts, scanners or preset lenses used in continuous motion applications (e.g., preset scan, tour and auto scan modes).
Two (2) years on Legacy®, Intercept® and CM8500/ CM9500/CM9750 Matrix products.
Two (2) years on WW5700 series window wiper (excluding wiper blades).
Pelco will warranty all replacement parts and repairs for 90 days from the date of shipment. All goods for warranty work shall be sent freight prepaid to our Clovis, California facility. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty. Pelco is not liable for any incidental or consequential expenses or liability incurred by the customer as a result of field repair, installation, or any other reason.
If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written explanation with the product when returned.
Ship freight prepaid to: Pelco
300 West Pontiac Way Clovis, CA 93612-5699
Method of return shipment shall be the same as method by which the repair item is received by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289- 9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair). Goods returned for repair or credit should be clearly identified with the assigned CA/RA number and freight should be prepaid. All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Ship freight prepaid to: Pelco
300 West Pontiac Way Clovis, CA 93612-5699
The above warranty is in lieu of any other expressed or implied warranty, condition, or guarantee by Pelco of the equipment listed herein. Pelco makes no warranties except for intended use and will not be liable for any loss, damage, or costs arising, whether consequential or incidental, from the use of said merchandise.
This warranty gives you specific legal rights. You may also have additional rights, which are subject to variation from state to state.
If a warranty repair is required, contact Pelco at (800) 289-9100 or (559) 292-1981 for a Repair Authorization number (RA), and provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order
number, or Pelco invoice number
3. Details of the defect or problem
Pelco Manual C494M-D (1/96) 9
®
Pelco
300 West Pontiac Way
Clovis, CA 93612-5699 USA
(559) 292-1981 • (800) 289-9100
FAX (800) 289-9150 or (559) 292-3827 DataFAX (800) 289-9108 or (559) 292-0435
International customers call 1-559-292-1981 or FAX 1-559-348-1120
(Product specifications subject to change without notice.)
C494M-D
10 Pelco Manual C494M-D (1/96)
Loading...