IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
3. Only use replacement parts recommended by Pelco.
4. After replacement/repair of this unit’s electrical components, conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry.
Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.
MODELS
Blower Kits
BK700 For use with E706 or E708 Series Enclosure, 120 VAC, 60 Hz, 4 watts,
10 cfm internal air circulation
BK700/220 Same as BK700 except 230 VAC, 50 Hz, 9 watts, 8 cfm internal air
circulation
BK700/24 Same as BK700 except 24 VAC, 3 watts, 19 cfm of internal air circulation
Heater Kits
HK706-1 Thermostatically controlled, 120 VAC, 80 watts, for E706 Series Enclosure
only. Activates ON at 40°F (4°C) and OFF at 60°F (16°C) HK706-2 Same as HK706-1 except 24 VAC HK706-3 Same as HK706-1 except 230 VAC HK708/10-1 Thermostatically controlled, 120 VAC, 107 watts, for E708 Series
Enclosure only. Activates ON at 40°F (4°C) and OFF at 60°F (16°C) HK708/10-2 Same as HK708/10-1 except 24 VAC, 66 watts HK708/10-3 Same as HK708/10-1 except 230 VAC, 84 watts
INSTALLATION
CAUTION:
When a single power source is used for both the camera and accessories, the camera power consumption must be taken into consideration when determining the wire gauge. However, the following chart does not include camera power because of the many variations.
Table A. Power Requirements and Recommended Cable Sizes
Model Number Input Voltage Power Consumption Cable Size Cable Distance
BK700 120 VAC 4 watts 22 AWG 10,651 feet (3,246 m)
BK700/24 24 VAC 3 watts 20 AWG 914 feet (279 m)
20 AWG 17,143 feet (5,225 m) 18 AWG 27,108 feet (8,262 m) 16 AWG 43,062 feet (13,125 m)
18 AWG 1,446 feet (441 m) 16 AWG 2,297 feet (700 m) 14 AWG 3,650 feet (1,113 m)
Continued on next page
Table A. Power Requirements and Recommended Cable Sizes (Continued)
Model Number Imput Voltage Power Consumption Cable Size Cable Distance
BK700/200 230 VAC 9 watts 20 AWG 25,609 feet (7,805 m)
HK706-1 120 VAC 80 watts 20 AWG 533 feet (162 m)
HK706-2 24 VAC 80 watts 20 AWG 34 feet (10 m)
HK706-3 230 VAC 80 watts 20 AWG 2,881 feet (878 m)
HK708/10-1 120 VAC 107 watts 22 AWG 398 feet (121 m)
HK708/10-2 24 VAC 66 watts 20 AWG 42 feet (13 m)
HK708/10-3 230 VAC 84 watts 20 AWG 2,744 feet (836 m)
Combination of 120 VAC 84 watts 22 AWG 507 feet (155 m)
BK700 & 20 AWG 816 feet (249 m) HK706-1 18 AWG 1,291 feet (393 m)
Combination of 24 VAC 83 watts 20 AWG 33 feet (10 m)
BK700-24 & 18 AWG 52 feet (16 m)
HK706-2 16 AWG 83 feet (25 m)
Combination of 230 VAC 89 watts 20 AWG 2,590 feet (789 m)
BK700/220 & 18 AWG 4,095 feet (1,248 m)
HK706-3 16 AWG 6,505 feet (1,983 m)
Combination of 120 VAC 111 watts 22 AWG 384 feet (117 m)
BK700 & 20 AWG 618 feet (188 m)
HK708/10-1 18 AWG 977 feet (298 m)
Combination of 24 VAC 69 watts 20 AWG 40 feet (12 m)
BK700/24 & 18 AWG 63 feet (19 m) HK708/10-2 16 AWG 100 feet (30 m)
Combination of 230 VAC 93 watts 20 AWG 2,748 feet (755 m)
BK700/220 & 18 AWG 3,919 feet (1,194 m)
HK708/10-3 16 AWG 6,225 feet (1,897 m)
18 AWG 40,495 feet (12,342 m) 16 AWG 64,328 feet (19,606 m) 14 AWG 102,239 feet (31,161 m)
18 AWG 857 feet (261 m) 16 AWG 1,355 feet (413 m) 14 AWG 2,153 feet (656 m)
18 AWG 54 feet (17 m) 16 AWG 86 feet (26 m) 14 AWG 137 feet (42 m)
18 AWG 4,556 feet (1,389 m) 16 AWG 7,237 feet (2,206 m) 14 AWG 11,502 feet (3,506 m)
20 AWG 641 feet (195 m) 18 AWG 1,013 feet (3092 m) 16 AWG 1,6102 feet (491 m)
18 AWG 66 feet (20 m) 16 AWG 104 feet (32 m) 14 AWG 166 feet (51 m)
18 AWG 4,399 feet (1,322 m) 16 AWG 6,8928 feet (2,101 m) 14 AWG 10,954 feet (3,339 m)
16 AWG 2,051 feet (625 m)
14 AWG 132 feet (40 m)
14 AWG 10,339 feet (3,151 m)
16 AWG 1,552 feet (473 m)
14 AWG 159 feet (48 m)
14 AWG 9,894 feet (3,016 m)
Blower Kit
If you are istalling the blower kit in conjunction with a heater kit, skip this section and refer to
Blower and Heater Kits (Dual Installation)
To install a blower kit, perform the following steps:
1. Attach the blower assembly onto the brackets at the rear of the camera sled using the hardware provided (see Figure 1).
2. Wire as shown in Figure 2. Refer to Table A for recommended cable sizes.
.