HB6000, HB6000/220, and
HB6024
Heater/Blower Kits
Installation/Operation
Manual C496M (12/90)
1.0 WARNINGS
Prior to installation and use of this product, the following
WARNINGS should be observed.
1. Installation and servicing should only be done by
Qualified Service Personnel and conform to all
Local codes.
2. Installation should be in accordance with all
applicable local and national electric codes, utilizing
approve materials only.
3. Only use replacement parts recommended by Pelco.
Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.
2.0 SCOPE
The information within this manual covers the installation of the HB6000, HB6000/220, and HB6024 Heater/
Blower Kits.
3.0 DESCRIPTION
The HB6000 (120 VAC), HB6000/220 (230 VAC), and
the HB6024 (24 VAC) are field installed heater/blower
kits for the HS1000 and HS6000 series high security
enclosures. These heater/blower kits will help stabilize
the internal enclosure temperatures when the enclosures
are subjected to more extreme conditions.
The heaters provide 80 watts of heat thermostatically
controlled to turn ON at 40°F (4.44°C) and OFF at 60°F
(15.56°C).
Pelco • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • www.pelco.com
(800) 289-9100 or (1-559) 292-1981 • FAX (800) 289-9150 or (1-559) 292-3827
International customers call (1-559) 292-1981 or FAX (1-559) 348-1120
3.1 MODELS
3.2 INPUT POWER REQUIREMENTS
HB6000 120 VAC thermostatically controlled
heater and blower. Heater provides
80 watts of heat and activates ON at
40°F (4.44°C) and OFF at 60°F
(15.56°C). Blower provides internal
air circulation (12 cfm at 4 watts) and
activates ON at 110°F (43.33°C) and
OFF at 80°F (26.67°C).
HB6000/220 Same as HB6000 except 230 VAC
operation. (Blower: 12 cfm at 4.5 watts)
HB6024 Same as HB6000 except 24 VAC
operation. (Blower: 19 cfm at 3 watts)
Input Power
Model Voltage Consumption Cable Size Cable Distance
HB6000 120 VAC 90 watts 22 Awg 464.7 ft (141.64 m)
Blower: HB6000 — 0.04 amp (4.5 vA)
HB6000/220 — 0.04 amp (4.5 vA)
HB6024 — 0.18 amp (4.5 vA)
Heater: HB6000 — 0.68 amp (80 vA)
HB6000/220 — 0.68 amp (80 vA)
HB6024 — 3.30 amp (80 vA)
3.3 RECOMMENDED CABLE SIZE
CAUTION: When using a single power
source for both the camera and accessories, the
camera power consumption must be taken into
consideration when determining the wire gauge.
The following cable sizes are the minimum recommended for use with the combination of blower/heater/
camera.
20 Awg 738.9 ft (225.22 m)
18 Awg 1,175.5 ft (358.29 m)
16 Awg 1,865.7 ft (568.66 m)
HB6000/220 230 VAC 90 watts 24 Awg 1,047.4 ft (319.25 m)
22 Awg 1,666.0 ft (507.80 m)
20 Awg 2,649.2 ft (807.48 m)
18 Awg 4,214.6 ft (1,284.61 m)
16 Awg 6,688.8 ft (2,038.75 m)
HB6024 24 VAC 90 watts 20 Awg 31.5 ft (9.60 m)
18 Awg 50.2 ft (15.30 m)
16 Awg 79.6 ft (24.26 m)
14 Awg 127.0 ft (38.71 m)
2 Pelco Manual C496M (12/90)
3.4 POWER REQUIREMENTS
4.2 BLOWER/PCB ASSEMBLY
The blower and heater require a 24 VAC/120 VAC/230
VAC, 50/60 Hz single phase power source. They use
the following wattage when in operation.
Blower: 4.5 watts
Heater: 80 watts
4.0 INSTALLATION
To install the HB6000, HB6000/220, and HB6024 perform the following steps. Refer to Figure 1.
4.1 HEATER ASSEMBLY
1. Open the cover or access door.
2. The heater brackets are designed to attach to two
(2) adjacent studs retaining the window.
3. Remove any two (2) adjacent nuts and washers
(preferably at the bottom of the window) on both
sides of the window.
4. Place the heater brackets on the studs, heaters
angled away from the window, and replace and
tighten the hardware.
1. Open the cover or access door(s).
2. On the HS1000, the blower/PCB bracket is designed to attach to any two (2) adjacent studs retaining the bottom plate. On the HS6000, the
blower/PCB bracket is designed to attach to the
two (2) studs at the bottom of the window.
3. On the HS1000, remove any two (2) adjacent nuts
and washers retaining the bottom plate to the
mounting frame. On the HS6000, remove the nuts
and washers retaining the bottom of the window.
4. Place the blower/PCB bracket over the studs and
replace and tighten the hardware
Figure 1. HB6000, HB6000/220, and HB6024 Assembly
Pelco Manual C496M (12/90) 3