FTV/FRV40D2(M,S)1(ST,FC)
4-CHANNEL 10-BIT DIGITALLY ENCODED VIDEO + 2 BIDIRECTIONAL DATA CHANNELS + 1 BIDIRECTIONAL CONTACT CLOSURE
utilizing state of the art 10-bit digital encoding and decoding for very high quality
video transmission, along with two channels of bidirectional data and one
bidirectional contact closure over one single mode or multimode optical fiber.
This equipment is environmentally hardened and suitable for use in
unconditioned roadside or out-of plant installations.
The FTV/FRV40D2(M,S)1(ST,FC) is compatible with NTSC, PAL and SECAM
video transmission protocols and supports bi-directional RS232, RS422 and
RS485 (2W/4W) data. See Figure 4 on Page 4 for data selection.
See Figure 6 on Page 6 for contact switch positions.
Bi-Color LED indicators are provided to indicate the status of the system, video
and data. See Figure 7 on Page 6 for LED indication explanations.
These units are interchangeable between stand-alone or card mount
configurations. See Figure A on Page 7 for mounting instructions.
See Figures 1 – 7 for complete installation details. No additional parts or power
supplies are required.
C5634M-A / REV 07-24-14
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the points where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
14. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases shall be placed on the apparatus.
15. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
16. Installation should be done only by qualified personnel and conform to all local codes.
17. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
18. Use only installation methods and materials capable of supporting four times the maximum specified load.
19. A CCC-approved power cord must be used to power this equipment when used in China.
20. CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
C5634M-A / REV 07-24-14
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981
INSTALLATION AND OPERATION MANUAL FTV/FRV40D2(M,S)1(ST,FC)
GND
+Vin
PWR
123
4
OPTICAL
IN/OUT
VIDEOOUT
DATA 1
GND
BIAS DOUT - DOUT +
TERM
DIN - DIN +
DATA 2
GND
BIAS DOUT - DOUT +
TERM
DIN - DIN +
OUT
OUT
IN IN
CONTACT
GND
+Vin
PWR
123
4
OPTICAL
IN/OUT
VIDEOIN
DATA 1
GND
BIAS DOUT - DOUT +
TERM
DIN - DIN +
DATA 2
GND
BIAS DOUT - DOUT +
TERM
DIN - DIN +
OUT
OUT
IN IN
CONTACT
GND
+Vin
PWR
123
4
OPTICAL
IN/OUT
VIDEOOUT
DATA 1
GND
BIAS DOUT - DOUT +
TERM
DIN - DIN +
DATA 2
GND
BIAS DOUT - DOUT +
TERM
DIN - DIN +
OUT
OUT
IN IN
CONTACT
FIGURE 1 – FTV/FRV40D2(M,S)1(ST,FC) TRANSMITTER AND RECEIVER
MULTIMODE OR SINGLE MODE OPTICAL FIBER
BLACK WITH WHITE STRIPE
BLACK Power Supply: Surface Mount: 9 VDC @ 2W Rack Mount: From Rack
FIGURE 2 – TRANSMITTER
REAR PANEL REAR PANELFRONT PANEL FRONT PANEL
FTV40D2S1ST
4CHANNEL DIGITAL
VIDEOTRANSMITTER
+
2CHANNELSOF
BI-DIRECTIONAL DATA
BI-DIRECTIONAL CONTACT
LINK
VIDEO 1
+
1234
12 12
VIDEO 2
VIDEO3
VIDEO 4
ON
DATA 1
DATA 2
POWER
CONTACT
DATA 1
DATA 2
GND
BIAS DOUT ­DOUT +
TERM
DIN ­DIN +
GND
BIAS DOUT ­DOUT +
TERM
DIN ­DIN +
OUT
OUT
IN IN
NOTE: Remove Electrical Connector for Rack Mount Units
FIGURE 3 – RECEIVER
FRV40D2S1ST
4CHANNEL
DIGITAL VIDEORECEIVER
IN/OUT
OPTICAL
DATA 1
DATA 2
VIDEOIN
CONTACT
GND
+Vin
123
4
PWR
BI-DIRECTIONAL DATA
BI-DIRECTIONAL C ONTACT
+
2CHANNELSOF
+
LINK
VIDEO 1
VIDEO 2
VIDEO3
VIDEO 4
POWER
GND BIAS
DOUT -
CONTACT
1234
DATA 1
12 12
DATA 2
ON
DATA 1
DATA 2
DOUT +
TERM
DIN ­DIN +
GND
BIAS DOUT ­DOUT +
TERM
DIN ­DIN +
OUT
OUT
DATA 1
DATA 2
VIDEOOUT
IN IN
CONTACT
GND
+Vin
IN/OUT
OPTICAL
123
PWR
4
C5634M-A / REV 07-24-14
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981
INSTALLATION AND OPERATION MANUAL FTV/FRV40D2(M,S)1(ST,FC)
DATA 1
12 12
CONTACT
1234
123
OPTICAL
IN/OUT
DATA 1
D
FIGURE 4 – DATA SWITCH POSITIONS
The mode for each data channel is configured using a pair switches on the front panel of the unit.
1) RS232 2) RS422, Bi-Phase or Manchester
Switch
GND BIAS
DOUT -
OUT +
TERM
DIN ­DIN +
1) RS232
DIN (–) DOUT (–) GND
1
2
3) RS485 2-Wire, Sensornet
1
2
2) RS422, Bi-Phase, Manchester
DIN (+) DIN (–) DOUT (+) DOUT (–) GND
1
2
4) RS485 4-Wire
1
2
3) RS485 2-Wire, Sensornet
DIN (+) DIN (–) GND
4) RS485 4-Wir
DIN (+) DIN (–) DOUT (+) DOUT (–) GND
Termination Note
A 120 ohm termination resistor is applied to the differential inputs when TERM is wired directly to DIN – (see diagram below).
C5634M-A / REV 07-24-14
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981
INSTALLATION AND OPERATION MANUAL FTV/FRV40D2(M,S)1(ST,FC)
FIGURE 5 – DATA CONNECTIONS
See Page 4 for Switch Settings
RS-232
RS-422
Bi-phase or Manchester
2-Wire
RS-485,
Sensornet
Customer
Equipment
Data Transmit
Data Receive
Signal Ground
Data Out (+)
Data Out (-)
Data In (+)
Data In (-)
Data In (+)
Data In (-)
Data (A)
Data (B)
Transmitter
DIN(-)
DOUT(-)
GND
DIN(+)
DIN(-)
DOUT(+)
DOUT(-)
DOUT(+)
DOUT(-)
DIN(+)
DIN(-)
Receiver
DOUT(-)
DIN(-)
GND
DOUT(+)
DOUT(-)
DIN(+)
DIN(-)
DIN(+)
DIN(-)
DIN(+)
DIN(-)
Customer
Equipment
Data Receive
Data Transmit
Signal Ground
Data In (+)
Data In (-)
Data Out (+)
Data Out (-)
Data Out (+)
Data Out (-)
Data (A)
Data (B)
4-Wire
RS-485
Data Out (A)
Data Out (B)
Data In (A)
Data In (B)
DIN(+)
DIN(-)
DOUT(+)
DOUT(-)
DOUT(+)
DOUT(-)
DIN(+)
DIN(-)
Data In (A)
Data In (B)
Data Out (A)
Data Out (B)
C5634M-A / REV 07-24-14
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981
INSTALLATION AND OPERATION MANUAL FTV/FRV40D2(M,S)1(ST,FC)
123
4
OPTICAL
IN/OUT
VIDEOOUT
DATA 1
GND BIAS
TERM
DIN - DIN +
DATA 2
GND BIAS
TERM
DIN - DIN +
CONT
CO
T
FIGURE 6 – CONTACT SWITCH POSITIONS
OUT OUT
IN IN
1234
NTAC
ACT
The four CONTACT switches on the front of the unit set the operating mode of the CONTACT OUT terminal pair.
It can either function as an alarm to indicate fault conditions, or it can function as a contact closure to indicate the state of the CONTACT IN terminal pair on the rear of the unit at the other end of the fiber.
1 2 3 4
ON OFF OFF OFF Closed when optical Port has established link.
Open when Optical Port has lost link.
ON ON ON OFF Closed when Optical Port has established link and all video signals are present.
Open when Optical Port has lost Link, or if a Video signal is lost.
ON ON ON ON Contact Closure mode.
State based on CONTACT IN at other end of fiber link.
FIGURE 7 – LED INDICATORS
LINK VIDEO (1 – 4) DATA (1 – 2) POWER
GREEN Communication link has been
established over optical fiber
RED Communication link has not been
established
OFF Not powered up correctly Unit powered down
Active video signal present
on the BNC connector.
No video signal No data signal
Active data signal
present
Unit powered up
C5634M-A / REV 07-24-14
TECH SUPPORT: (800) 289-9100 INTERNATIONAL: +1 (559) 292-1981
MECHANICAL INSTALLATION INSTRUCTIONS
INSTALLATION CONSIDERATIONS
This fiber-optic link is supplied as a Standalone/Rack module. Units should be installed in dry locations protected from extremes of temperature and humidity.
CARD CAGE RACKS
CAUTION: Although the units are hot-swappable and may be installed
without turning power off to the rack, the manufacturer recommends that the power supply be turned off and that the rack power supply is disconnected from any power source. Note: Remove electrical connector before installing in card cage rack.
1. Make sure that the card is oriented right side up, and slide it into the card guides in the rack until the edge connector at the back of the card seats in the corresponding slot in the rack’s connector panel. Seating may require thumb pressure on the top and bottom of the card’s front panel.
CAUTION: Take care not to press on any of the LEDs.
2. Tighten the two thumb screws on the card until the front panel of the card is seated against the front of the rack.
WARNING: Unit is to be used with a Listed Class 2 or LPS power supply.
FIGURE A
Dimensions are for a standard two slot module
.2 (5.2)
11.9 (4.7)
0.63 (0.25)
7.5 (2.9) 15 (5.9)
IMPORTANT SAFEGUARDS: A) Elevated Operating Ambient - If installed in a closed or multi-unit rack
assembly, the operating ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified by the manufacturer.
B) Reduced Air Flow - Installation of the equipment in a rack should be such
that the amount of air flow required for safe operation of the equipment is not compromised.
5.5 (2.2)
C5634M-A / REV 07-24-14
PRODUCT WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
•Five years: –Fiber optic products – Unshielded Twisted Pair (UTP) transmission products –CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and
MC3651H-2X camera models
• Three years: –FD Series and BU Series analog camera models –Fixed network cameras and network dome cameras with Sarix –Sarix thermal imaging products (TI and ESTI Series) –Fixed analog camera models (C20 Series, CCC1390H Series, C10DN Series,
and C10CH Series) – EH1500 Series enclosures –Spectra –Spectra HD dome products –Camclosure
®
IV products (including Spectra IV IP)
®
IS Series integrated camera systems
– DX Series video recorders (except DX9000 Series which is covered for a
period of one year), DVR5100 Series digital video recorders, Digital Sentry
Series hardware products, DVX Series digital video recorders, and NVR300
Series network video recorders
®
– Endura – Genex
Series distributed network-based video products
®
Series products (multiplexers, server, and keyboard) – PMCL200/300/400 Series LCD monitors –PMCL5xxF Series and PMCL5xxNB Series LCD monitors
•Two years: –Standard varifocal, fixed focal, and motorized zoom lenses – DF5/DF8 Series fixed dome products
®
–Legacy –Spectra III
Series integrated positioning systems
, Spectra Mini, Spectra Mini IP, Esprit®, ExSite®, ExSite IP, and
PS20 scanners, including when used in continuous motion applications – Esprit Ti and TI2500 Series thermal imaging products – Esprit and WW5700 Series window wiper (excluding wiper blades) –CM6700/CM6800/CM9700 Series matrix – Digital Light Processing (DLP
®
) displays (except lamp and color wheel). The lamp and color wheel will be covered for a period of 90 days. The air filter is not covered under warranty.
®
technology
•Six months: – All pan and tilts, scanners, or preset lenses used in continuous motion
applications (preset scan, tour, and auto scan modes)
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to a Pelco designated location. Repairs made necessary by reason of misuse,
alteration, normal wear, or accident are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental, or consequential damages (including loss of use, loss of profit, and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state.
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization
®
following information:
number (RA), and provide the
1. Model and serial number
2. Date of shipment, P. O. number, sales order number, or Pelco invoice number
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product that does not fall under the warranty conditions stated above, please include a written explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
RETURNS
To expedite parts returned for repair or credit, please call Pelco at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair) and designated return location.
All merchandise returned for credit may be subject to a 20 percent restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid.
Revised 1-12-12
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.
Pelco, the Pelco logo, and other trademarks associated with Pelco products referred to in this publication are trademarks of Pe .cnI ,ocleP ,2102 thgirypoC © .setailiffa sti ro .cnI ,ocl All other product names and services are the property of their respective companies. All rights reserved. Product specifications and availability are subject to change without notice.
www.pelco.com
Pelco, Inc. 625 W. Alluvial, Fresno, California 93711 United States
USA & Canada Tel (800) 289-9100 Fax (800) 289-9150
International Tel +1 (559) 292-1981 Fax +1 (559) 348-1120
Loading...