Attachment of Ferrite to Data Cable of FT85081 Transmitter
A snap-on ferrite is supplied with the FT85081MSTR, FT85081SSTR, and FT85081SFCR transmitters. The ferrite must be attached to the data cable of the transmitters to comply with FCC and CE emissions requirements.
After data connections are made to the data connector on the transmitter, attach the ferrite to the data cable. When attaching the ferrite to the cable, position the ferrite as close as possible to the transmitter.
NOTE: The ferrite should fit securely around the cable. If the ferrite is loose and slides along the cable, loop the cable through the ferrite before closing the ferrite. If, however, the thickness of the cable prevents the ferrite from closing, use a tie wrap to hold the ferrite in place rather than looping the cable.
Pelco World Headquarters • 3500 Pelco Way, Clovis, California 93612-5699 USA USA & Canada: Tel: 800/289-9100 • Fax: 800/289-9150 International: Tel: 1-559/292-1981 • Fax: 1-559/348-1120
®
www.pelco.com
INSTALLATION
FT85081/FR85081 Fiber Transmitter
®
and Receiver
Eight-Channel Digitally Encoded Video with Bidirectional Data
C1648M (4/05)

Contents

Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Front Panel - FT85081 Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Front Panel - FR85081 Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Rear Panel - FT85081 Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Rear Panel - FR85081 Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Package Contents. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Data Communication Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Mounting the Transmitter/Receiver into a Rack . . . . . . . . . . . . . . . . . . . . . . . . . .14
Mounting the Transmitter/Receiver Using the Wall Clip. . . . . . . . . . . . . . . . . . . . 15
Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

List of Illustrations

1 Eight-Channel Video FT85081 Transmitter and FR85081 Receiver
with Bidirectional Data Channel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2 Front Panel of FT85081 Transmitter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
3 Front Panel of FR85081 Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
4 Rear Panel of FT85081 Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5 Rear Panel of FR85081 Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
6 Data Selection Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
7 Mounting the FT85081 Transmitter/FR85081 Receiver Using the Wall Clip. . . . . . . . . . 15
8 FT85081 Transmitter/FR85081 Receiver Connections. . . . . . . . . . . . . . . . . . . . . . . . . . .16
9 RS-232 Data Communication Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
10 RS-422 Data Communication Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
11 RS-485 2-Wire (Half Duplex) Data Communication Wiring. . . . . . . . . . . . . . . . . . . . . . .20
12 RS-485 4-Wire (Full Duplex) Data Communication Wiring . . . . . . . . . . . . . . . . . . . . . . .21
13 Manchester Data Communication Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
14 Bi-Phase Data Communication Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
2 C1648M (4/05)

List of Tables

A Data Selection Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
B Data Connector Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
CTroubleshooting with Front-Panel Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
C1648M (4/05) 3

Important Safety Instructions

1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the points where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/ apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
15. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases shall be placed on the apparatus.
WARNING:
16. rain or moisture.
17. Installation should be done only by qualified personnel and conform to all local codes.
18. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
19. Use only installation methods and materials capable of supporting four times the maximum specified load.
To reduce the risk of fire or electric shock, do not expose this apparatus to
4 C1648M (4/05)
CAUTION:
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
To reduce the risk of electric shock do not perform any servicing other that contained in the operating instructions unless you are qualified to do so.
The product and/or manual may bear the following marks:
These servicing instructions are for use by qualified service personnel only.
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
C1648M (4/05) 5

Regulatory Notices

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission’s rules.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
6 C1648M (4/05)

Product Overview

DESCRIPTION

The FT85081/FR85081 fiber transmitter and receiver provide the ability to transmit eight unidirectional composite video channels and one bidirectional data channel over one optical fiber (refer to Figure 1).
EIGHT VIDEO
INPUTS
DATA
Figure 1.
FT85081
TRANSMITTER
ONE
FIBER
FR85081
RECEIVER
Eight-Channel Video FT85081 Transmitter and FR85081 Receiver
EIGHT VIDEO
OUTPUTS
DATA
with Bidirectional Data Channel
Features of the FT85081/FR85081 fiber optic transmission system include the following:
8-bit digitally encoded video for high-quality multi-channel video transmission over a single fiber
Bidirectional data channel that supports RS-232, RS-422, RS-485 (2-wire/4-wire), Manchester, and Bi-Phase communication
•Wavelength division multiplexing (WDM), allowing video and data channels to be transmitted in the same fiber using different wavelengths
Multimode fiber support for distances up to 1 km (0.6 mi)
Single-mode fiber support for distances up to 30 km (18.6 mi)
Exceeds all requirements for the RS-250C Medium-Haul Transmission specification
Compatible with NTSC, PAL, and SECAM video standards
No performance adjustments required
12 VDC or 24 VAC power supply
Standalone and rack-mountable modular design
LED indicators for monitoring of signal status, data activity, and operating power
NOTE:
The FT85081 transmitter/FR85081 receiver is a Class 1 laser product that complies with FDA radiation performance standard 21CFR Subchapter J and with IEC 60825-1 Edition 1.2, 2001-08.
C1648M (4/05) 7

MODELS

The FT85081/FR85081 fiber transmitter and receiver consist of the following series of models:
Multimode Models:
FT85081MSTR Eight-channel fiber optic video transmitter/single-channel data transceiver;
FR85081MSTR Eight-channel fiber optic video receiver/single-channel data transceiver;
Single-Mode Models:
FT85081SSTR Eight-channel fiber optic video transmitter/single-channel data transceiver;
FR85081SSTR Eight-channel fiber optic video receiver/single-channel data transceiver;
FT85081SFCR Eight-channel fiber optic video transmitter/single-channel data transceiver;
FR85081SFCR Eight-channel fiber optic video receiver/single-channel data transceiver;
OPTIONAL ACCESSORIES
The following optional accessories are available: RK5000-3U 19-inch rack mount chassis for 14 slots (no power), 3 RUs RK5000PS-3U 19-inch rack mount chassis for 12 slots with power, 3 RUs EPS5000-120 External/redundant power supply, 1 RU, 120 W x 2 RK5001B-3U Blank filler panel, single width RK5002B-3U Blank filler panel, double width RK5003-1UEXP Adapter kit that allows a 3 RU triple-width fiber optic module to be used in
multimode, ST connector
multimode, ST connector
single-mode, ST connector
single-mode, ST connector
single-mode, FC connector
single-mode, FC connector
RK5000PS-5U rack mount chassis
8 C1648M (4/05)

FRONT PANEL

The front panel of the FT85081 transmitter and the FR85081 receiver provides LED indicators that allow you to monitor data activity, signal status, and operating power. The following sections provide a view of the front panel of the FT85081 transmitter and the FR85081 receiver.
FRONT PANEL - FT85081 TRANSMITTER
Figure 2 illustrates the front panel of the FT85081 transmitter.
 
8
Tx
Rx
7
6
5
4
3
2
1
Figure 2.
DATA TX LED
DATA RX LED
CARRIER DETECT LED
POWER LED (Pelco badge)
VIDEO PRESENT LEDs (1-8)
For detailed information about the front-panel indicators, refer to the
Front Panel of FT85081 Transmitter