Pelco FR85011A User Manual

INSTALLATION
FT85011A/FR85011A Fiber Transmitter
®
and Receiver
Single-Channel Digitally Encoded Video with Bidirectional Data
C2604M (7/06)

Contents

Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Models. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Front Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Data Communication Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Mounting the Transmitter/Receiver into a Rack . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Mounting the Transmitter/Receiver to a Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

List of Illustrations

1 FT85011A Transmitter and FR85011A Receiver Single-Channel Video
and Data Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2 Front Panel of FT85011A Transmitter and FR85011A Receiver . . . . . . . . . . . . . . . . . . . 10
3 Rear Panel of FT85011A Transmitter and FR85011A Receiver . . . . . . . . . . . . . . . . . . . . 11
4 Data Selection Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5 Mounting the FT85011A Transmitter/FR85011A Receiver Using the Wall Clip. . . . . . . 15
6 FT85011A Transmitter/FR85011A Receiver Connections . . . . . . . . . . . . . . . . . . . . . . . . 16
7 RS-232 Data Communication Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
8 RS-422 Data Communication Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
9 RS-485 2-Wire (Half Duplex) Data Communication Wiring . . . . . . . . . . . . . . . . . . . . . . 20
10 RS-485 4-Wire (Full Duplex) Data Communication Wiring . . . . . . . . . . . . . . . . . . . . . . . 21
11 Manchester Data Communication Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
12 Bi-Phase Data Communication Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

List of Tables

A Data Communication Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
B Data Connector Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
C Troubleshooting with Front-Panel Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
C2604M (7/06) 3

Important Safety Instructions

1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the points where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
14. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases shall be placed on the apparatus.
WARNING:
15. or moisture.
16. Installation should be done only by qualified personnel and conform to all local codes.
17. Use only installation methods and materials capable of supporting four times the maximum specified load.
18. A CCC-approved power cord must be used to power this equipment when used in China.
CAUTION:
19. To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
To reduce the risk of fire or electric shock, do not expose this apparatus to rain
These servicing instructions are for use by qualified service personnel only.
4 C2604M (7/06)
The product and/or manual may bear the following marks:
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
C2604M (7/06) 5

Regulatory Notices

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission’s rules.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
6 C2604M (7/06)

Product Overview

DESCRIPTION

The FT85011A/FR85011A fiber transmitter and receiver provide the ability to transmit one unidirectional composite video channel and one bidirectional data channel over one optical fi ber. In addition, patent­pending technology provides the solution for allowing Coaxitron be transmitted the full distance of the fiber (up to 6 km for multimode fiber and up to 46 km for single­mode fiber). Figure 1 illustrates FT85011A transmitter and FR85011A receiver single-channel video and data applications.
®
pan/tilt/zoom (PTZ) control data to
ONE VIDEO INPUT
DATA
ONE VIDEO INPUT
COAXITRON
DATA
Figure 1.
FT85011A
TRANSMITTER
AND BIDIRECTIONAL DATA APPLICATION
FT85011A
TRANSMITTER
SINGLE-CHANNEL VIDEO
AND COAXITRON DATA APPLICATION
ONE
FIBER
SINGLE-CHANNEL VIDEO
ONE
FIBER
FR85011A RECEIVER
FR85011A RECEIVER
FT85011A Transmitter and FR85011A Receiver Single-Channel Video
ONE
VIDEO
OUTPUT
DATA
ONE
VIDEO
OUTPUT
COAXITRON
DATA
and Data Applications
Features of the FT85011A/FR85011A fiber optic transmission system include the following:
8-bit digitally encoded video for high-quality video transmission over a single fiber
Bidirectional data channel that supports RS-232, RS-422, RS-485 (2-wire/4-wire), Manchester, Bi-Phase, and Coaxitron communication
Patent-pending transmission technology allowing for Coaxitron control at full-distance capabilities
Integrated wavelength division multiplexing (WDM), allowing video and data channels to be transmitted in the same fiber using different wavelengths
Multimode fiber support for distances up to 6 km
Single-mode fiber support for distances up to 46 km
Exceeds all requirements for the RS-250C Medium-Haul Transmission specification
Compatible with NTSC, PAL, and SECAM video standards
C2604M (7/06) 7
Meets NEMA TS 2 and Caltrans traffic signal control equipment standards for ambient operating temperature, mechanical shock and vibration, humidity with condensation, high-line/low-line voltage conditions, and transient voltage protection
NOTE:
Conformal coating is required for operation in environments with relative humidity
above 95% (condensing).
No performance adjustments required
12 VDC or 24 VAC power supply
Stand-alone and rack-mountable modular design
LED indicators for monitoring of signal status, laser status, data activity, and operating power
In addition, note the following:
The FT85011A transmitter/FR85011A receiver is a Class 1 laser product that complies with FDA radiation performance standard 21CFR Subchapter J and with IEC 60825-1 Edition 1.2, 2001-08.
In addition to compatibility with each other, the FT85011A transmitter and the FR85011A receiver are compatible with other fiber models:
The FT85011A transmitter is backward compatible with the FR85011 receiver.
The FR85011A receiver is backward compatible with the FS85011 and FT85011 transmitters.
For optical power budget and maximum transmission distance specifications of the various module-compatible pairs, refer to the
Specifications
section. For additional information about
the FR85011, FS85011, and FT85011 modules, refer to the manual supplied with the modules.
8 C2604M (7/06)

MODELS

The FT85011A/FR85011A fiber transmitter and receiver consist of the following series of models :
Multimode Models:*
FT85011AMSTR Single-channel fiber optic video transmitter/data transceiver; multimode,
ST connector
FR85011AMSTR Single-channel fiber optic video receiver/data transceiver; multimode,
ST connector
Single-Mode Models:*
FT85011ASSTR Single-channel fiber optic video transmitter/data transceiver; single-mode,
ST connector
FR85011ASSTR Single-channel fiber optic video receiver/data transceiver; single-mode,
ST connector
FT85011ASFCR Single-channel fiber optic video transmitter/data transceiver; single-mode,
FC connector
FR85011ASFCR Single-channel fiber optic video receiver/data transceiver; single-mode,
FC connector
*For conformal coated models, replace the first letter F in the model number with the letter
The conformal coated version of FT85011AMSTR, for example, is CT85011AMSTR.
OPTIONAL ACCESSORIES
The following optional accessories are available:
WM5001-3U Wall mount base kit for single-width module
WM5001-3UEXP Wall mount expansion kit for single-width modul e
RK5000-3U 19-inch rack mount chassis for 14 slots (no power), 3 RUs
RK5000PS-3U 19-inch rack mount chassis for 12 slots with power, 3 RUs
EPS5000-120 External rack power supply, 1 RU, dual 120 W power outputs
RK5001B-3U Blank filler panel, single width
RK5002B-3U Blank filler panel, double width
RK5001-1UEXP Adapter kit that allows a 3 RU single-width fiber module to be used in
RK5000PS-5U rack mount chassis
C.
C2604M (7/06) 9

FRONT PANEL

The front panel of the FT85011A transmitter and the FR85011A receiver provides LED indicators that allow you to monitor data activity, signal status, laser status, and operating power (refer to Figure 2).
  
Tx
Rx
1
Tx
Rx
 
FT85011A
TRANSMITTER
Figure 2.
DATA TX LED
DATA RX LED
VIDEO PRESENT LED
OPTIC FAULT LED (optical signal status/laser status indicator)
POWER LED (Pelco badge)
For detailed information about the front-panel indicators, refer to the
Front Panel of FT85011A Transmitter and FR85011A Receiver
FR85011A
RECEIVER
 
 
Troubleshooting
section.
10 C2604M (7/06)