Pelco FR82041 User Manual

INSTALLATION
FT82041/FR82041 Unmanaged
®
Ethernet Switch
Four 10BASE-T/100BASE-TX Ports and One 100BASE-FX Fiber Port
C2623M (2/07)

Contents

Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Appendix. RJ-45 Connector Pinouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Models. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Optional Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Front Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Setting 10BASE-T/100BASE-TX Port Modes of Operation. . . . . . . . . . . . . . . . . . . . . . . 11
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Mounting the FT82041/FR82041 Module into a Rack . . . . . . . . . . . . . . . . . . . . . 13
Mounting the FT82041/FR82041 Module to a Wall . . . . . . . . . . . . . . . . . . . . . . . 13
Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
List of Illustrations
1 FT82041 and FR82041 Point-to-Point Application. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2 Front Panel of FT82041 and FR82041 Modules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
3 Rear Panel of FT82041 and FR82041 Modules (SC Fiber Connector Shown). . . . . . . . . 10
4 TX Mode Switches for 10BASE-T/100BASE-TX Ports 1-4 . . . . . . . . . . . . . . . . . . . . . . . 11
5 Mounting the FT82041/FR82041 Module Using the Wall Clip. . . . . . . . . . . . . . . . . . . . 14
6 FT82041/FR82041 Module Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
7 RJ-45 MDI/MDI-X Connector Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
List of Tables
A TX Mode Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
B Troubleshooting with Front-Panel Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
C Troubleshooting with Rear-Panel Indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
D RJ-45 MDI/MDI-X Connector Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Important Safety Instructions

1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the points where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
14. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases shall be placed on the apparatus.
15. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
16. Installation should be done only by qualified personnel and conform to all local codes.
17. Use only installation methods and materials capable of supporting four times the maximum specified load.
18. A CCC-approved power cord must be used to power this equipment when used in China.
19. CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
4 C2623M (2/07)
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.

Regulatory Notices

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission’s rules.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
6 C2623M (2/07)

Product Overview

DESCRIPTION

The FT82041/FR82041 unmanaged Ethernet switch provides four 10BASE-T/100BASE-TX ports and one 100BASE-FX fiber port for the transport of bidirectional Ethernet data. Designed for point-to-point applications, the FT82041 and FR82041 switches are used in combination with one another to provide wavelength compatibility (refer to Figure 1).
FOUR 10/100 Mbps
CONNECTIONS
FOUR 10/100 Mbps
CONNECTIONS
FT82041
ONE
FIBER
FR82041
Figure 1. FT82041 and FR82041 Point-to-Point Application
Features of the FT82041/FR82041 Ethernet data transmission system include the following:
User-selectable networking functions for each 10BASE-T/100BASE-TX port:
Autonegotiation between 10 Mbps and 100 Mbps data rates and between full-duplex
and half-duplex modes
10 Mbps or 100 Mbps selectable
Full-duplex or half-duplex mode selectable
Enabling/disabling of flow control
NOTE: The 100BASE-FX fiber port is automatically forced to full-duplex 100 Mbps operation.
Auto MDI/MDI-X (Medium Dependent Interface/Medium Dependent Interface Crossover) operation
Compliant with IEEE 802.3, 802.3u, 802.3x standards
Multimode fiber support for distances up to 2 km
Single-mode fiber support for distances up to 46 km
Integrated wavelength division multiplexing (WDM), which allows bidirectional data to be
transmitted in a single fiber
Laser diode for transmission of optical signals
NOTE: The FT82041/FR82041 switch is a Class 1 laser product that complies with FDA radiation performance standard 21CFR Subchapter J and with IEC 60825-1 Edition 1.2, 2001-08.
Compatible with other Ethernet equipment:
10BASE-T/100BASE-TX compatibility with all Pelco
©
and third-party 10BASE-T/
100BASE-TX Ethernet devices
Fiber optic compatibility with all Pelco Ethernet devices that support WDM
Environmentally hardened
Designed to meet NEMA TS 2 and Caltrans traffic signal control equipment standards for ambient operating temperature, mechanical shock and vibration, humidity with condensation, high-line/low-line voltage conditions, and transient voltage protection
NOTE: Conformal coating is required for operation in environments with relative humidity above 95 percent (condensing).
No performance adjustments required
12 VDC or 24 VAC power supply
Stand-alone and rack-mountable modular design
LED indicators for monitoring of optic signal/laser status, 100BASE-FX port status including far
end fault indication (FEFI), 10BASE-T/100BASE-TX port status, and operating power

MODELS

The FT82041 and FR82041 modules consist of the following series of models:
Multimode Models
FT82041MSTR-1 Unmanaged Ethernet switch, four 10BASE-T/100BASE-TX ports, one multimode
FR82041MSTR-1 Unmanaged Ethernet switch, four 10BASE-T/100BASE-TX ports, one multimode
FT82041MSCR-1 Unmanaged Ethernet switch, four 10BASE-T/100BASE-TX ports, one multimode
FR82041MSCR-1 Unmanaged Ethernet switch, four 10BASE-T/100BASE-TX ports, one multimode
Single-Mode Models
FT82041SSTR-1 Unmanaged Ethernet switch, four 10BASE-T/100BASE-TX ports, one single-
FR82041SSTR-1 Unmanaged Ethernet switch, four 10BASE-T/100BASE-TX ports, one single-
FT82041SSCR-1 Unmanaged Ethernet switch, four 10BASE-T/100BASE-TX ports, one single-
FR82041SSCR-1 Unmanaged Ethernet switch, four 10BASE-T/100BASE-TX ports, one single-
*For conformal coated models, replace the first letter F in the model number with the letter C.
The conformal coated version of FT82041MSTR-1, for example, is CT82041MSTR-1.
Single-mode FC connector is available upon request. Contact the factory for additional information.
*
ST fiber port, one fiber, fiber optic compatibity with FR82041MSTR-1 and other multimode ST Pelco Ethernet devices that support WDM
ST fiber port, one fiber, fiber optic compatibility with FT82041MSTR-1 and other multimode ST Pelco Ethernet devices that support WDM
SC fiber port, one fiber, fiber optic compatibility with FR82041MSCR-1 and other multimode SC Pelco Ethernet devices that support WDM
SC fiber port, one fiber, fiber optic compatibility with FT82041MSCR-1 and other multimode SC Pelco Ethernet devices that support WDM
*†
mode ST fiber port, one fiber, fiber optic compatibility with FT82041MSCR-1 and other single-mode ST Pelco Ethernet devices that support WDM
mode ST fiber port, one fiber, fiber optic compatibility with FT82041SSTR-1 and other single-mode ST Pelco Ethernet devices that support WDM
mode SC fiber port, one fiber, fiber optic compatibility with FR82041SSCR-1 and other single-mode SC Pelco Ethernet devices that support WDM
mode SC fiber port, one fiber, fiber optic compatibility with FT82041SSCR-1 and other single-mode SC Pelco Ethernet devices that support WDM
8 C2623M (2/07)

OPTIONAL ACCESSORIES

The following optional accessories are available:
WM5001-3U Wall mount base kit for single-width module WM5001-3UEXP Wall mount expansion kit for single-width module RK5000-3U 19-inch rack mount chassis for 14 slots (no power), 3 RUs RK5000PS-3U 19-inch rack mount chassis for 12 slots with power, 3 RUs EPS5000-120 External rack power supply, 1 RU, dual 120 W power outputs RK5001B-3U Blank filler panel, single width RK5002B-3U Blank filler panel, double width RK5001-1UEXP Adapter kit that allows a 3 RU single-width fiber module to be used in
RK5000PS-5U rack mount chassis

FRONT PANEL

Figure 2 illustrates the front panel of the FT82041 and FR82041 modules.
FT82041 FR82041
Figure 2. Front Panel of FT82041 and FR82041 Modules
ì
Reset Button: Restarts the unit
î
100BASE-FX Status LED
ï
Optic Fault LED: Optical signal status/laser status indicator
ñ
Power LED: Pelco badge
For detailed information about the front-panel LEDs, refer to Troubleshooting on page 17.
Loading...