Pelco FR106011 User Manual

INSTALLATION
FT106011/FR106011 Fiber Transmitter and Receiver
Video with Bidirectional Audio, Data, and Contact Closure
C2649M (9/07)
Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Regulatory Notices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Front Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Setting the Audio Signal and Impedance Mode . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Setting the Data Communication Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Mounting the Transmitter/Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Mounting the Transmitter/Receiver into a Rack . . . . . . . . . . . . . . . . . . . . . . 16
Mounting the Transmitter/Receiver to a Wall . . . . . . . . . . . . . . . . . . . . . . . 16
Connecting the Transmitter/Receiver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

List of Illustrations

1 FT106011/FR106011 Video, Audio, Data, and Contact Closure Transmission . . . 8
2 Front Panel of FT106011 Transmitter and FR106011 Receiver . . . . . . . . . . . . . . 10
3 Rear Panel of FT106011 Transmitter and FR106011 Receiver . . . . . . . . . . . . . . 11
4 Audio Select Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
5 Data Select Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
6 Mounting the FT106011 Transmitter/FR106011 Receiver Using the Wall Clip . 17
7 FT106011 Transmitter/FR106011 Recei ver Connections. . . . . . . . . . . . . . . . . . . 19
8 Normally Open Contact Closure Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
9 Normally Closed Contact Closure Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
10 RS-232 Data Communication Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
11 RS-422 Data Communication Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
12 RS-485 2-Wire (Half Duplex) Data Communication Wiring . . . . . . . . . . . . . . . . 24
13 RS-485 4-Wire (Full Duplex) Data Communication Wiring. . . . . . . . . . . . . . . . . 25
14 Manchester Data Communication Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
15 Bi-Phase Data Communication Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
16 Balanced Audio Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
17 Unbalanced Audio Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
C2649M (9/07) 3
List of Tables
A Audio Select Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
B Data Select Switch Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
C Contact Closure Pin Assignments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
D Data Connector Pin Assignments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
E Audio Connector Pin Assignments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
F Troubleshooting with Front-Panel Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
4 C2649M (9/07)

Important Safety Instructions

1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the points where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
14. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases shall be placed on the apparatus.
15. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.
16. Installation should be done only by qualified personnel and conform to all local codes.
17. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
18. Use only installation methods and materials capable of supporting four times the maximum specified load.
19. A CCC-approved power cord must be used to power this equipment when used in China.
20. CAUTION: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.
C2649M (9/07) 5
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
6 C2649M (9/07)

Regulatory Notices

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Changes and Modifications not expressly approved by the manufacturer or registrant of this equipment can void your authority to operate this equipment under Federal Communications Commission’s rules.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
C2649M (9/07) 7

Product Overview

DESCRIPTION

The FT106011/FR106011 fiber transmitter and receiver provide simultaneous transmission of one unidirectional video channel, two bidirectional audio channels, one bidirectional data channel, and one bidirectional contact closure over one optical fiber (refer to Figure 1).
VIDEO
AUDIO
DATA CONTACT CLOSURE
Figure 1. FT106011/FR106011 Video, Audio, Data, and Contact Closure Transmission
Features of the FT106011/FR106011 fiber optic transmission system include the following:
10-bit digitally encoded video for high-quality video transmission over a single fiber
Two bidirectional 24-bit digitally encoded audio channels with user-selectable 600-ohm balanced or 47K-ohm unbalanced input impedance
Bidirectional data channel with user-selectable RS-232, RS-422, RS-485 (2-wire/4-wire), Manchester, Bi-Phase, and Coaxitron
Bidirectional contact closure that allows a choice of normally open or normally closed outputs
Multimode fiber support for distances up to 6 km (3.7 mi)
Single-mode fiber support for distances up to 38 km (23.6 mi)
Laser diode for transmission of optical signals
NOTE: The FT106011 transmitter/FR106011 receiver is a Class 1 laser product that complies with FDA radiation performance standard 21CFR Subchapter J and with IEC 60825-1 Edition 1.2, 2001-08.
Patent-pending transmission technology allowing Coaxitron control at full-distance capabilities
Compatible with NTSC, PAL, and SECAM video standards
Designed to meet NEMA TS 2 and Caltrans traffic signal control equipment standards for ambient operating temperature, mechanical shock and vibration, humidity with condensation, high-line/low-line voltage conditions, and transient voltage protection
NOTE: Conformal coating is required for operation in environments with relative humidity above 95 percent (condensing).
No performance adjustments required
12 VDC or 24 VAC power supply
Stand-alone and rack-mountable modular design
LED indicators for monitoring of signal status, laser status, data activity, contact closure activation, and operating power
FT106011
TRANSMITTER
ONE
FIBER
®
communication
FR106011
RECEIVER
VIDEO
AUDIO
DATA CONTACT CLOSURE
8 C2649M (9/07)

MODELS

The FT106011/FR106011 fiber transmitter and receiver consist of the following series of models:
Multimode Models:*
FT106011MSTR Fiber optic video transmitter with two bidirectional audio channels, one
FR106011MSTR Fiber optic video receiver with two bidirectional audio channels, one
Single-Mode Models:*
FT106011SSTR Fiber optic video transmitter with two bidirectional audio channels, one
FR106011SSTR Fiber optic video receiver with two bidirectional audio channels, one
FT106011SFCR Fiber optic video transmitter with two bidirectional audio channels, one
FR106011SFCR Fiber optic video receiver with two bidirectional audio channels, one
*For conformal coated models, replace the first letter F in the model number with the letter C.
The conformal coated version of FT106011MSTR, for example, is CT106011MSTR.
bidirectional data channel, and one bidirectional contact closure; multimode, ST connector
bidirectional data channel, and one bidirectional contact closure; multimode, ST connector
bidirectional data channel, and one bidirectional contact closure; single-mode, ST connector
bidirectional data channel, and one bidirectional contact closure; single-mode, ST connector
bidirectional data channel, and one bidirectional contact closure; single-mode, FC connector
bidirectional data channel, and one bidirectional contact closure; single-mode, FC connector

OPTIONAL ACCESSORIES

The following optional accessories are available:
WM5001-3U Wall mount base kit for single-width module
WM5001-3UEXP Wall mount expansion kit for single-width module
RK5000-3U 19-inch rack mount chassis for 14 slots (no power), 3 RUs
RK5000PS-3U 19-inch rack mount chassis for 12 slots with power, 3 RUs
EPS5000-120 External rack power supply, 1 RU, dual 120 W power outputs
RK5001B-3U Blank filler panel, single width
RK5002B-3U Blank filler panel, double width
RK5001-1UEXP Adapter kit that allows a 3 RU single-width fiber module to be used in
C2649M (9/07) 9
RK5000PS-5U rack mount chassis

FRONT PANEL

The front panel of the FT106011 transmitter and FR106011 receiver provides LED indicators that allow you to monitor contact closure activation, audio signal status, data activity, video signal status, optical signal/laser status, and operating power (refer to Figure 2).
FT106011
TRANSMITTER
FR106011
RECEIVER
Figure 2. Front Panel of FT106011 Transmitter and FR106011 Receiver
CONTACT CLOSURE LED
AUDIO PRESENT LED
DATA ACTIVITY LED
VIDEO PRESENT LED
OPTIC FAULT LED (optical signal status/laser status indicator)
POWER LED (Pelco badge)
For additional information about the front-panel LEDs, refer to the Troubleshooting section.
10 C2649M (9/07)

REAR PANEL

All connections to the FT106011 transmitter and FR106011 receiver are made to the rear panel of the modules (refer to Figure 3).
Figure 3. Rear Panel of FT106011 Transmitter and FR106011 Receiver
RACK POWER/ALARM CONNECTOR, 4-pin connector for power/alarm connection of rack­mounted module
STAND-ALONE POWER CONNECTOR, 2-pin connector for power connection of stand-alone module; removable mating connector with screw terminals (not shown)
FIBER OPTIC CONNECTOR, ST or FC (dependent on FT106011/FR106011 model)
CONTACT CLOSURE CONNECTOR, 6-pin connector; removable mating connector with tension clamps (not shown)
DATA CONNECTOR, 8-pin connector; removable mating connector with tension clamps (not shown)
AUDIO CONNECTOR, 12-pin connector; removable mating connector with tension clamps (not shown)
BNC CONNECTOR, 75-ohm analog video input (FT106011)/output (FR106011)
For additional information about rear-panel connections, refer to the Installation section.
C2649M (9/07) 11

Installation

PACKAGE CONTENTS

The following items are supplied:
1 FT106011 transmitter or FR106011 receiver
1 Regulated switching power supply with four plug adapters (North American, Australian, U.K.,
and European configurations); 100-240 VAC, 50-60 Hz input, 12 VDC output
1 1 small flat-tip screwdriver
1 Wall clip with two 4-40 x 0.25-inch Phillips pan head screws with lock washers (for attachment
of single module to wall)
1 FT106011/FR106011 Fiber Transmitter and Receiver Installation manual (this manual)

SETTING THE AUDIO SIGNAL AND IMPEDANCE MODE

An Audio Select switch, which is a 10-position rotary switch, is provided on the bottom of the FT106011 transmitter and the FR106011 receiver (refer to Figure 5). The Audio Select switch allows you to set the desired audio mode of operation.
With the FT106011 transmitter/FR106011 receiver powered off, set the Audio Select switch to the desired mode of operation using the supplied screwdriver. Table B lists Audio Select switch settings and associated audio modes of operation as indicated on the bottom of the units.
NOTE: If you wish to change the audio mode after the FT106011 transmitter/FR106011 receiver has been powered on, power off the transmitter/receiver, change the audio mode, and then power on the transmitter/receiver again.
12 C2649M (9/07)
Loading...
+ 28 hidden pages