7. Do not block any ventilation openings. Install in accordance with the manufacturer’s
instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other
apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has
two blades with one wider than the other. A grounding type plug has two blades and a third
grounding prong. The wide blade or the third prong are provided for your safety. If the provided
plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience
receptacles, and the points where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold
with the apparatus. When a cart is used, use caution when moving the cart/apparatus
combination to avoid injury from tip-over.
13. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has
been damaged in any way, such as power-supply cord or plug is damaged, liquid has been
spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
14. Apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids,
such as vases shall be placed on the apparatus.
15. WARNING: To reduce the risk of fire or electric shock, do not expose this apparatus to rain or
moisture.
16. Installation should be done only by qualified personnel and conform to all local codes.
17. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is
designed for indoor use only and it must not be installed where exposed to rain and moisture.
18. Use only installation methods and materials capable of supporting four times the maximum
specified load.
19. A CCC-approved power cord must be used to power this equipment when used in China.
20. CAUTION: These servicing instructions are for use by qualified service personnel only. To
reduce the risk of electric shock do not perform any servicing other than that contained in the
operating instructions unless you are qualified to do so.
C2649M (9/07)5
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage
constituting a risk of electric shock is present
within this unit.
This symbol indicates that there are important
operating and maintenance instructions in the
literature accompanying this unit.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
6C2649M (9/07)
Regulatory Notices
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) this device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
RADIO AND TELEVISION INTERFERENCE
This equipment has been tested and found to comply with the limits of a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case
the user will be required to correct the interference at his own expense.
Changes and Modifications not expressly approved by the manufacturer or registrant of this
equipment can void your authority to operate this equipment under Federal Communications
Commission’s rules.
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
C2649M (9/07)7
Product Overview
DESCRIPTION
The FT106011/FR106011 fiber transmitter and receiver provide simultaneous transmission of one
unidirectional video channel, two bidirectional audio channels, one bidirectional data channel, and
one bidirectional contact closure over one optical fiber (refer to Figure 1).
VIDEO
AUDIO
DATA
CONTACT
CLOSURE
Figure 1. FT106011/FR106011 Video, Audio, Data, and Contact Closure Transmission
Features of the FT106011/FR106011 fiber optic transmission system include the following:
•10-bit digitally encoded video for high-quality video transmission over a single fiber
•Two bidirectional 24-bit digitally encoded audio channels with user-selectable 600-ohm
balanced or 47K-ohm unbalanced input impedance
•Bidirectional data channel with user-selectable RS-232, RS-422, RS-485 (2-wire/4-wire),
Manchester, Bi-Phase, and Coaxitron
•Bidirectional contact closure that allows a choice of normally open or normally closed outputs
•Multimode fiber support for distances up to 6 km (3.7 mi)
•Single-mode fiber support for distances up to 38 km (23.6 mi)
•Laser diode for transmission of optical signals
NOTE: The FT106011 transmitter/FR106011 receiver is a Class 1 laser product that complies
with FDA radiation performance standard 21CFR Subchapter J and with IEC 60825-1 Edition 1.2,
2001-08.
•Patent-pending transmission technology allowing Coaxitron control at full-distance capabilities
•Compatible with NTSC, PAL, and SECAM video standards
•Designed to meet NEMA TS 2 and Caltrans traffic signal control equipment standards for
ambient operating temperature, mechanical shock and vibration, humidity with condensation,
high-line/low-line voltage conditions, and transient voltage protection
NOTE: Conformal coating is required for operation in environments with relative humidity
above 95 percent (condensing).
•No performance adjustments required
•12 VDC or 24 VAC power supply
•Stand-alone and rack-mountable modular design
•LED indicators for monitoring of signal status, laser status, data activity, contact closure
activation, and operating power
FT106011
TRANSMITTER
ONE
FIBER
®
communication
FR106011
RECEIVER
VIDEO
AUDIO
DATA
CONTACT
CLOSURE
8C2649M (9/07)
MODELS
The FT106011/FR106011 fiber transmitter and receiver consist of the following series of models:
Multimode Models:*
FT106011MSTRFiber optic video transmitter with two bidirectional audio channels, one
FR106011MSTRFiber optic video receiver with two bidirectional audio channels, one
Single-Mode Models:*
FT106011SSTRFiber optic video transmitter with two bidirectional audio channels, one
FR106011SSTRFiber optic video receiver with two bidirectional audio channels, one
FT106011SFCRFiber optic video transmitter with two bidirectional audio channels, one
FR106011SFCRFiber optic video receiver with two bidirectional audio channels, one
*For conformal coated models, replace the first letter F in the model number with the letter C.
The conformal coated version of FT106011MSTR, for example, is CT106011MSTR.
bidirectional data channel, and one bidirectional contact closure; multimode,
ST connector
bidirectional data channel, and one bidirectional contact closure; multimode,
ST connector
bidirectional data channel, and one bidirectional contact closure; single-mode,
ST connector
bidirectional data channel, and one bidirectional contact closure; single-mode,
ST connector
bidirectional data channel, and one bidirectional contact closure; single-mode,
FC connector
bidirectional data channel, and one bidirectional contact closure; single-mode,
FC connector
OPTIONAL ACCESSORIES
The following optional accessories are available:
WM5001-3UWall mount base kit for single-width module
WM5001-3UEXPWall mount expansion kit for single-width module
RK5000-3U19-inch rack mount chassis for 14 slots (no power), 3 RUs
RK5000PS-3U19-inch rack mount chassis for 12 slots with power, 3 RUs
EPS5000-120External rack power supply, 1 RU, dual 120 W power outputs
RK5001B-3UBlank filler panel, single width
RK5002B-3UBlank filler panel, double width
RK5001-1UEXPAdapter kit that allows a 3 RU single-width fiber module to be used in
C2649M (9/07)9
RK5000PS-5U rack mount chassis
FRONT PANEL
The front panel of the FT106011 transmitter and FR106011 receiver provides LED indicators that allow
you to monitor contact closure activation, audio signal status, data activity, video signal status, optical
signal/laser status, and operating power (refer to Figure 2).
FT106011
TRANSMITTER
FR106011
RECEIVER
Figure 2. Front Panel of FT106011 Transmitter and FR106011 Receiver
CONTACT CLOSURE LED
AUDIO PRESENT LED
DATA ACTIVITY LED
VIDEO PRESENT LED
OPTIC FAULT LED (optical signal status/laser status indicator)
POWER LED (Pelco badge)
For additional information about the front-panel LEDs, refer to the Troubleshooting section.
10C2649M (9/07)
REAR PANEL
All connections to the FT106011 transmitter and FR106011 receiver are made to the rear panel of the
modules (refer to Figure 3).
Figure 3. Rear Panel of FT106011 Transmitter and FR106011 Receiver
RACK POWER/ALARM CONNECTOR, 4-pin connector for power/alarm connection of rackmounted module
STAND-ALONE POWER CONNECTOR, 2-pin connector for power connection of stand-alone
module; removable mating connector with screw terminals (not shown)
FIBER OPTIC CONNECTOR, ST or FC (dependent on FT106011/FR106011 model)
BNC CONNECTOR, 75-ohm analog video input (FT106011)/output (FR106011)
For additional information about rear-panel connections, refer to the Installation section.
C2649M (9/07)11
Installation
PACKAGE CONTENTS
The following items are supplied:
1FT106011 transmitter or FR106011 receiver
1Regulated switching power supply with four plug adapters (North American, Australian, U.K.,
and European configurations); 100-240 VAC, 50-60 Hz input, 12 VDC output
11 small flat-tip screwdriver
1Wall clip with two 4-40 x 0.25-inch Phillips pan head screws with lock washers (for attachment
of single module to wall)
1 FT106011/FR106011 Fiber Transmitter and Receiver Installation manual (this manual)
SETTING THE AUDIO SIGNAL AND IMPEDANCE MODE
An Audio Select switch, which is a 10-position rotary switch, is provided on the bottom of the
FT106011 transmitter and the FR106011 receiver (refer to Figure 5). The Audio Select switch allows
you to set the desired audio mode of operation.
With the FT106011 transmitter/FR106011 receiver powered off, set the Audio Select switch to the
desired mode of operation using the supplied screwdriver. Table B lists Audio Select switch settings
and associated audio modes of operation as indicated on the bottom of the units.
NOTE: If you wish to change the audio mode after the FT106011 transmitter/FR106011 receiver has
been powered on, power off the transmitter/receiver, change the audio mode, and then power on the
transmitter/receiver again.
12C2649M (9/07)