Pelco ES-MKIT User Manual

ES-MKIT Marine Kit C2211M (12/04)
®
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Only use attachments/accessories specified by the manufacturer.
6. Installation should be done only by qualified personnel and conform to all local codes.
7. This product is not suitable for splash zone installations. Only use stainless steel marine-rated enclosures and pan and tilts for splash zone installations.
DESCRIPTION
The ES-MKIT marine kit is designed to protect the Esprit® Series positioning system from galvanic corrosion by electrically isolating the system from the mounting structure. When installed correctly the marine kit eliminates the conductive path between the aluminum Esprit mount/adapter and the dissimilar metal of the mounting structure.
The ES-MKIT includes the following parts:
Qty Description
1 Gasket 4 0.620 x 0.360-inch nylon shoulder washers 4 0.328 x 0.562-inch stainless steel flat washers
IMPORTANT:
Galvanic corrosion is a process that is common in a marine environment. It requires marine installation techniques to protect the installation. If you are unfamiliar with such installation techniques, you should consult a marine installation expert.
Pelco cannot accept any responsibility for incorrect installations that result in galvanic corrosion damage to the unit.
This product must be installed correctly to provide protection against galvanic corrosion. Failure to follow these installation instructions will void the warranty
E
INSTALLATION
To install the ES-MKIT marine kit, refer to Figure 1 and do the following:
1. Align the mounting holes of the mount/adapter with the mounting holes of the gasket.
2. Secure the mount/adapter and the gasket to the mounting structure by doing the following:
a. Insert a shoulder washer in a mounting hole of the mount/adapter and then place a flat
washer over the shoulder washer.
b. Insert a bolt through the flat washer and shoulder washer. Use bolts with a maximum
diameter of 3/8-inch (0.95 cm). The bolts are not supplied.
c. Hand-tighten the bolt to the mounting structure.
d. Repeat the above steps to secure all sides of the mount/adapter.
e. Tighten the four bolts.
3. To complete the installation of the EWM wall mount or EPP pedestal adapter, refer to the installation instructions supplied with the mount/adapter.
4. Use a resistance meter to verify that a conductive path does not exist after the installation is completed.
5. Use a galvanic isolator (not supplied) to connect the Esprit ground to safety ground. The galvanic isolator must have a duty rating exceeding 135% of the service rating. Galvanic isolators are sold at most marine shops.
SHOULDER WASHER
FLAT WASHER
GASKET
BOLT (NOT SUPPLIED)
EWM MOUNT
Figure 1.
ES-MKIT Installation
Worldwide Headquarters • 3500 Pelco Way • Clovis, California 93612 USA • www.pelco.com
USA & Canada • Tel: 800/289-9100 • Fax: 800/289-9150
International • Tel: 1-559/292-1981 • Fax: 1-559/348-1120
sprit, Pelco and the Pelco logo are registered trademarks of Pelco. ©Copyright 2004, Pelco. All rights reserved.