Mounts
EWM, EPM, ECM100, and EPP
®
Important Safety Instructions
1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
2. Use only installation methods and materials capable of supporting four times the maximum specified load.
3. Use stainless steel hardware to fasten the mount to outdoor surfaces.
4. To prevent damage from water leakage when installing a mount outdoors on a roof or wall, apply sealant around the bolt holes between the mount and mounting surface.
Description
This manual contains the installation instructions for the following Esprit
®
mounts:
EWM Wall Mount Use to mount an Esprit system directly to a load bearing vertical surface.
EPM Pole Mount Use in conjunction with the EWM to mount an Esprit system to a pole.
ECM100 Corner Mount Use in conjunction with the EWM to mount an Esprit system to a building corner.
EPP Pedestal Adapter Use to mount an Esprit system directly to a pedestal mount.
Installation
EWM ESPRIT WALL MOUNT
1. Remove the knockouts from the conduit plate. Use the plate as a template. Mark the conduit and fastener positions onto the mounting surface. Prepare the surface.
2. Attach the gasket to the end of the EWM.
3. Install the conduit fittings (not supplied). If conduit is not used, install
sealing glands (supplied) on the conduit plate. Thread the wiring/cabling
through the conduit plate/sealing glands and EWM wall mount. Attach the EWM to the mounting surface with the appropriate hardware (not supplied). Refer to the manual supplied with the Esprit system to complete the installation.
NOTE: Refer to Tables A and B for wiring distances.
EPM ESPRIT POLE MOUNT
1. Thread wiring/cabling through the hole in the pole mount and attach the mount to the pole with three stainless steel straps (supplied).
2. Attach the gasket to the end of the EWM.
3. Remove the knockouts from the conduit plate. Install the conduit fittings (not supplied). If conduit is not used, install sealing glands (supplied) on the conduit plate. Route the wiring/cabling through the conduit plate/ sealing glands and EWM wall mount. Secure the EWM and conduit plate to the pole mount with the supplied hardware. Refer to the manual supplied with the Esprit system to complete the installation.
ECM100 ESPRIT CORNER MOUNT
1. Use the ECM100 mount as a template and mark the fastener positions onto the mounting surface. Prepare the surface. Route the wiring/ cabling through the ECM100. Attach the ECM100 to the mounting surface with the appropriate hardware (not supplied).
2. Attach the gasket to the end of the EWM.
3. Remove the knockouts from the conduit plate. Install the conduit fittings (not supplied). If conduit is not used, install sealing glands (supplied) on the conduit plate. Route the wiring/cabling through the conduit plate/ sealing glands and EWM wall mount. Secure the mount to the ECM100 with the supplied hardware. Refer to the manual supplied with the Esprit system to completed the installation.
NOTE: Refer to Tables A and B for wiring distances.