I N S T A L L A T I O N
Esprit® Series Mounts
EWM, EPM, ECM100,
EPP2
Wall, Pole, Corner, and Pedestal
C225M-G (5/21)

Important Safety Instructions
1. Installation and servicing should only be done by qualified service personnel and conform to all local codes.
2. Use only installation methods and materials capable of supporting four times the maximum specified load.
3. Use stainless steel hardware to fasten the mount to outdoor surfaces.
4. To prevent damage from water leakage when installing a mount outdoors on a roof o
mount and mounting surface.
Description
This manual contains the installation instructions for the following Esprit® mounts:
NOTE: Esprit mounts do not ship with conduit fittings or mounting hardware, unless noted otherwise.
EWM Wall Mount: Use to mount an Esprit system directly to a vertical load bearing surface.
Qty Description
1 Wall mount
1 Conduit plate
1 Gasket
3 10-32 x 3/4-inch Philips flat head screws
2 Sealing glands
EPM Pole Mount: Use with EWM to m
Qty Description
1 Pole mount
3 Stainless steel straps
4 3/8-inch flat washers
4 5/16-18 nuts
4 5/16-inch lock washers
r wall, apply sealant around the bolt holes between the
ount an Esprit system to a pole.
ECM100 Corner Mount: Use with EWM to mount an Esprit system to a building corner.
Qty Description
1 Corner mount
1 Corner mount with 5/16-18 x 1.25-inch studs
4 3/8-inch flat washers
4 5/16-18 nuts
4 5/16-inch lock washers
EPP2 Pedestal Adapter: Use to mount an Esprit system directly to a pedestal mount; includes pedestal adapter only.
Qty Description
3 10-32 x 1/2-inch Phillips flathead screws
2 C225M-G (5/21)

Installation
NOTE: Before installing any mount or Esprit system, refer to Video and Power Cable Wiring Distances on page 5.
EWM ESPRIT WALL MOUNT
1. Remove one or both knockouts from the conduit plate.
2. Using the plate as a template, mark the conduit and fastener positions on the mounting surface.
3. Prepare the mounting surface.
Figure 1. Conduit Plate Knockouts and Sealing Glands
4. Install conduit fitting
5. Attach the gasket (supplied) to the end of the EWM mount.
6. Thread the wiring/cabling through the conduit plate/sealing glands and the EWM mount.
7. Use mounting hardware (not supplied) to secure the EWM to the mounting surface.
8. Refer to the manual supplied with the Esprit
s (not supplied) or sealing glands (supplied) in the conduit plate (refer to Figure 1).
Figure 2. Attaching the Gasket to the EWM
system to complete the installation.
C225M-G (5/21) 3