Prior to installation and use of this product, the following WARNINGS should be observed.
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions
5. Only use attachments/accessories specified by the manufacturer.
6. Installation should be done only by qualified personnel and conform to all local codes.
7. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is
designed for indoor use only and it must not be installed where exposed to rain and moisture.
8. Use only installation methods and materials capable of supporting four times the maximum
specified load.
9. Use stainless steel hardware to fasten the mount to outdoor surfaces.
10. To prevent damage from water leakage when installing a mount outdoors on a roof or wall, apply
sealant around the bolt holes between the mount and mounting surface.
11. Only use replacement parts recommended by Pelco.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage
constituting a risk of electric shock is present within
this unit.
This symbol indicates that there are important
operating and maintenance instructions in the
literature accompanying this unit.
Please thoroughly familiarize yourself with the information in this manual prior to installation and
operation.
C261M-D (4/14)3
Description
The EM1450 light duty wall mount has been designed for use with the EH2508, EH2512, EH2515, EH3508,
EH3512, and EH3515 enclosures. It can be installed on a wall or vertical surface, indoors or outdoors, and
is capable of supporting up to 9 kilograms (20 pounds).
The EM1450 has an adjustable tilt table that allows manual positioning of the enclosure.
PARTS LIST
The following parts are supplied.
Qty Description
1Mount, light duty wall
2Screws, Phillips pan head, 1/4-20 x 0.500-inch
1Installation manual
USER SUPPLIED PARTS LIST
The following installation parts and tools are needed but not supplied.
Qty Description
1Enclosure, EH2508, EH2512, EH2515, EH3508, EH3512, or EH3515
1Phillips screwdriver
2-4 Appropriate mounting fasteners depending on nature of mounting surface
1Appropriate water-tight sealant, if installing the product outdoors
Installing the Mount
1. Using the wall mount as a template, mark the holes for the mounting hardware on the mounting
surface.
WARNINGS:
•Make certain the mounting surface can support the full load of the mount,
enclosure, and camera.
•When installing the mount outdoors, seal the bolt holes with an appropriate
sealant to prevent water damage to the mounting surface. Apply the sealant
around the bolt holes located between the mount and the mounting surface.
2. Prepare the surface.
3. Attach the mount to the mounting surface with the appropriate hardware (not supplied). If you
install the mount outdoors, apply a sealant between the mount and the mounting surface.
4. Attach the enclosure to the tilt table with the two 1/4-20 x 0.500-inch screws (supplied).
5. Adjust the pan position of the mount:
a.Loosen the cap nut on the tilt table support bracket.
b.Adjust the pan position of the tilt table by moving it to the left or right.
c.Retighten the cap nut.
4C261M-D (4/14)
6. Adjust the tilt position of the mount:
a.Loosen the two screws on the tilt table.
b.Move the tilt table up or down.
c.Retighten the screws.
C261M-D (4/14)5
Specifications
MODEL
EM1450Light duty wall mount; for use with EH2508, EH2512, EH2515,
MECHANICAL
Suggested Mounting MethodSecure to solid surface with 2-4 fasteners, minimum M6
Enclosure Mounting2 each: 1/4-20 x 0.500-inch screws
Pan Adjustment360°
Tilt Adjustment ±75° (up or down)
Locking Method
Pan1/4-20 high crown cap nut
Tilt2 each: 3/8-16 x 0.500-inch bolts
GENERAL
Construction
Mounting ArmDie-cast aluminum
Tilt Table and Support BracketAluminum
FinishGray polyester powder coat
Maximum Load9 kg (20 lb)
Unit Weight0.91 kg (2 lb)
NOTE: VALUES IN PARENTHESES ARE INCHES; ALL OTHERS ARE CENTIMETERS.
EH3508, EH3512, and EH3515 enclosures
(1/4-inch) diameter recommended.
3.81
(1.50)
5.08
(2.00)
7.62
(3.00)
7.21
(2.84)
13.51
(5.32)
0.69 (Ø 0.272), 7X
8.81
(3.47)
4.42
(1.73)
26.75
(10.53)
28.50
(11.22)
6.99
(2.75)
3.81
(1.50)
0.87 (Ø 0.343),
1X
(1.25)
6C261M-D (4/14)
3.18
0.713 (Ø 0.281),
3X
7.26
(2.86)
8.84
(3.48)
WARRANTY STATEMENT
For information about Pelco’s product warranty and thereto related information, refer to www.pelco.com/warranty.
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive
2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE).
Contact your local dealer for procedures for recycling this equipment.
REVISION HISTORY
Manual #DateComments
C261M
C261M3/00Revised Figure 1 and installation step 4 per ECO 00-5634.
C261M-A2/06Revised to new format. Corrected measurements in dimension drawing.
C261M-B 1/08Revised mounting head hole pattern per ECO 07-17992.
C261M-C1/11Updated the Important Safety Instructions and Warranty, revised the Installation and Specifi-
C261M-D4/14Updated template, metric/imperial dimensions, and supplied screw size.
Pelco, the Pelco logo, and other trademarks a ssociated with Pelco products referred to in this publication are trademarks of P elco, Inc. or its affiliates.
All other product names and services are th e property of their respective companies. ONVIF and the ONVIF logo are trademarks of ONVIF Inc.
/99Original version.
3
cations sections, and applied current format.
Pelco, Inc. 625 W. Alluvial Fresno, California 93711 United States
USA & Canada Tel (800) 289-9100 Fax (800) 289-9150
International Tel +1 (559) 292-1981 Fax +1 (559) 348-1120
www.pelco.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.