Pelco EH3512, EH3515 User Manual 2

Page 1
®
EH3508/EH3512/
EH3515 Series
Environmental
Enclosure
Installation/
Operation Manual
C478M-L (11/03)
Pelco • 3500 Pelco Way, Clovis • CA 93612-5699 USA • Pelco Online @ http://www.pelco.com In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 • DataFAX (800) 289-9108 International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120 • DataFAX (1-559) 292-0435
Page 2
IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1. Installation and servicing should only be done by qualified service personnel and con­form to all local codes.
2. Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P enclo­sure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
3. Only use replacement parts recommended by Pelco.
4. After replacement/repair of this unit’s electrical components, conduct a resistance measurement between line and exposed parts to verify the exposed parts have not been connected to line circuitry.
5. The installation method and materials should be capable to supporting four times the weight of the enclosure, pan/tilt, camera and lens combination.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit.
This symbol indicates that there are impor­tant operating and maintenance instructions in the literature accompanying this unit.
Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
DESCRIPTION
The EH3508/EH3512/EH3515 Series are indoor/outdoor light-duty camera enclosures de­signed for use with various cameras on the market and accommodate fixed focal length or motorized zoom lenses, with or without auto-iris operation.
The lid of the enclosure is hinged in the front providing easy access during installation and when camera and lens adjustments are necessary. The camera sled also serves as an el­evation block. Y ou can remove, flip, and then reinstall the sled to elevate the camera. All wir­ing and cabling is brought into the enclosure through adjustable glands at the bottom rear of the enclosure.
The rear link-lock latch can be used with a padlock of suitable size for applications requiring additional security.
MODELS
EH3508 Enclosure, indoor/outdoor, 8.75-inch (22.23 cm) lower body length. (CE) EH3508-1 Same as EH3508 except unit is supplied with 120 VAC heater and defroster,
EH3508-2 Same as EH3508 except unit is supplied with 24 VAC heater and defroster, EH3508-3 Same as EH3508 except unit is supplied with 230 VAC heater and defroster, EH3512 Enclosure, indoor/outdoor, 12.75-inch (32.38 cm) lower body length. (CE)
EH3512-1 Same as EH3512 except unit is supplied with 120 VAC heater, defroster, EH3512-1HD Same as EH3512 except unit is supplied with 120 VAC heater and defroster, EH3512-2 Same as EH3512 except unit is supplied with 24 VAC heater, defroster, and EH3512-2HD Same as EH3512 except unit is supplied with 24 VAC heater and defroster,
13 watts. 13 watts. (CE) 13 watts.
and blower, 17 watts. 13 watts. blower, 15 watts. (CE) 13 watts. (CE)
2 Pelco Manual C478M-L (11/03)
Page 3
EH3512-3 Same as EH3512 except unit is supplied with 230 VAC heater, defroster, EH3512-3HD Same as EH3512 except unit is supplied with 230VAC heater and defroster, EH3515 Enclosure, indoor/outdoor, 15.75-inch (40.00 cm) lower body length. (CE)
EH3515-1 Same as EH3515 except unit is supplied with 120 VAC heater, defroster, EH3515-1HD Same as EH3515 except unit is supplied with 120 VAC heater and defroster, EH3515-2 Same as EH3515 except unit is supplied with 24 VAC heater, defroster, and EH3515-2HD Same as EH3515 except unit is supplied with 24 VAC heater and defroster, EH3515-3 Same as EH3515 except unit is supplied with 230 VAC heater, defroster, EH3515-3HD Same as EH3515 except unit is supplied with 230 VAC heater and defroster,
INSTALLATION
The following items are supplied to mount the enclosure:
2 1/4-20 x .500-inch hex head screws 2 Flat washers 2 Split washers
The following items are supplied to mount the camera:
2 1/4-20 x .375-inch Phillips-head screws
and blower, 22 watts. 13 watts.
and blower, 27 watts. 23 watts. blower, 25 watts. (CE) 23 watts. (CE) and blower, 32 watts. 23 watts.
Perform the following steps to install the enclosure, camera, and lens:
1. Unlatch and open the lid.
2. Remove the camera sled from the rail. a. Loosen the screws that hold the camera sled in place. b. Slide the sled forward so it can be lifted out over the screws. c. Remove the sled. d. Remove the parts tied to the sled.
3. If you are wiring the enclosure with cable, remove the glands and nuts from the parts bag and install them in the bottom of the enclosure. If you are wiring the enclosure with conduit, do not install the glands.
4. Attach the enclosure body to the appropriate mount using the instructions provided with the mount.
Attach the enclosure through the threaded mounting holes in the bottom of the enclo­sure. Use the 1/4-20 x .500 screws and washers provided (in the parts bag). Com­pletely tighten the screws to attach the enclosure body to the mounting surface.
5. Attach the camera to the sled with the 1/4-20 x .375-inch Phillips-head screws pro­vided (in the parts bag). You can attach the camera to either side of the sled. The side of the sled to which you mount the camera depends on the type of camera and lens you are attaching.
The edges of the sled are bent–one side up and the other side down. On one side of the sled, the lip is wide; on the other side of the sled, the lip is narrow. In a typical in­stallation, you mount the camera so that the holes in the wide lip of the sled fit over the sled mounting screws.
However, you can elevate the sled if you are installing a camera with a low optical cen­ter line or a camera with a large diameter lens. To elevate the sled (and therefore el­evate the camera), flip the sled over so that the holes in the narrow lip of the sled fit over the sled mounting screws.
6. Move the sled so that the sled mounting screws extend through the narrow part of sled mounting holes, and partially tighten the sled mounting screws.
Pelco Manual C478M-L (11/03) 3
Page 4
7. Pull the video and power cables through the glands or conduit on the bottom of the en­closure. Refer to Tables A and B to determine the size of power wire to use. Refer to Table C for the type of video coaxial cable to use.
8. Attach the cables to the camera.
9. If the enclosure has accessories that require power, connect the power to pins 1 and 2 on the PC Board (refer to Figures 1, 2, and 3 for information about accessory wiring). Connect ground to pin 3 if required.
You can connect the camera power to the PC board if the voltages are the same be­tween the accessories and camera. If you want to connect the camera power to the PC board, connect the camera power to pins 1 and 2. Connect ground to pin 3 if required.
10. If the camera lens is adjustable, extend the lens to its maximum length; verify that the camera is adjusted with the lens a minimum of 1/2 inch from the enclosure window.
11. Tighten the screws that secure the sled to the enclosure.
12. Adjust the glands for a tight fit around the cables.
13. Close the enclosure lid, and latch.
14. Adjust the camera focus and iris if necessary. If you need to adjust the focus and iris manually, open the enclosure lid, adjust the focus and iris, and close the enclosure lid.
INPUT, AC HIGH INPUT, AC LOW (NEUTRAL) GROUND
DEFROSTER
HEATER
24/120/230 VAC MODELS
1 2 3 4 5 6 7 8 9
10
DEFROSTER
120 VAC MODELS
1 2 3 4 5 6 7 8 9
10
DEFROSTER
Figure 2. EH3512-1/-1HD/-2/-2HD/-3/-3HD Wiring Diagram
INPUT, AC HIGH INPUT, AC LOW (NEUTRAL) GROUND
BLOWER
HEATER
230 VAC MODEL
1 2 3 4 5 6 7 8 9
10
Figure 1. EH3508-1/-2/-3 Wiring Diagram
24 VAC MODEL
1 2 3
DEFROSTER BLOWER
INPUT, AC HIGH INPUT, AC LOW (NEUTRAL) GROUND
120 VAC BLOWER
HEATER
4 5 6 7 8 9
10
RESISTOR
RED BLK
BRIDGE
NOTE: BLOWER APPLIES TO -1/-2/-3 MODELS ONLY.
INPUT, AC HIGH INPUT, AC LOW (NEUTRAL) GROUND
RED
DIODE
BLK CAP
HEATER
4 Pelco Manual C478M-L (11/03)
Page 5
120 VAC MODEL
24 VAC MODEL
DEFROSTER
INPUT, AC HIGH
1 2 3 4 5 6 7 8 9
10
INPUT, AC LOW (NEUTRAL) GROUND
BLOWER
FRONT HEATER
REAR HEATER
1 2 3
DEFROSTER BLOWER
4 5 6 7 8 9
10
INPUT, AC HIGH INPUT, AC LOW (NEUTRAL) GROUND
RED BLK
BRIDGE
RED
DIODE
BLK CAP
FRONT HEATER
REAR HEATER
230 VAC MODEL
INPUT, AC HIGH INPUT, AC LOW (NEUTRAL) GROUND
120 VAC BLOWER
FRONT HEATER
REAR HEATER
RESISTOR
NOTE: BLOWER APPLIES TO -1/-2/-3 MODELS ONLY.
DEFROSTER
1 2 3 4 5 6 7 8 9
10
Figure 3. EH3515-1/-1HD/-2/-2HD/-3/-3HD Wiring Diagram
CAUTION:
When using a single power source for both camera and accessories, consider the camera power
consumption when determining the wire gauge. T able A does not include camera power.
Table A. Enclosure Accessory Wiring Distances
The following cable sizes are the minimum recommended for use with the heater and defroster combination in enclosures in the EH3508 Series, and the heater, defroster, and blower combination in enclosures in the EH3512 Series and EH3515 Series only.
Model Number Input Voltage Accessories Power Consumption Cable Size Cable Distance
EH3508-1 120 VAC Heater 13 watts 20 AWG 5,456 ft (1,662 m) EH3512-1HD at 60 Hz Defroster 18 AWG 8,680 ft (2,645 m)
16 AWG 13,777 ft (4,199 m) 14 AWG 21,978 ft (6,698 m)
EH3508-2 24 VAC Heater 13 watts 20 AWG 218 ft (66 m) EH3512-2HD at 60 Hz Defroster 18 AWG 347 ft (105 m)
16 AWG 551 ft (167 m) 14 AWG 879 ft (267 m)
EH3508-3 230 VAC Heater 13 watts 20 AWG 20,045 ft (6,109 m) EH3512-3HD at 50 Hz Defroster 18 AWG 31,890 ft (9,720 m)
16 AWG 50,612 ft (15,426 m) 14 AWG 80,738 ft (24,608 m)
EH3512-1 120 VAC Heater 17 watts 20 AWG 4,172 ft (1,271 m)
at 60 Hz Defroster 18 AWG 6,658 ft (2,023 m)
Blower 16 AWG 10,535 ft (3,211 m)
14 AWG 16,806 ft (5,122 m)
EH3512-2 24 VAC Heater 15 watts 20 AWG 189 ft (57 m)
at 60 Hz Defroster 18 AWG 300 ft (91 m)
Blower 16 AWG 477 ft (145 m)
14 AWG 761 ft (231 m)
EH3512-3 230 VAC Heater 22 watts 20 AWG 11,845 ft (3,610 m)
at 50 Hz Defroster 18 AWG 18,844 ft (5,743 m)
Blower* 16 AWG 29,907 ft (9,115 m)
14 AWG 47,709 ft (14,541 m)
EH3515-1 120 VAC Heater 27 watts 20 AWG 29 ft (8 m)
at 60 Hz Defroster 18 AWG 47 ft (14 m)
Blower 16 AWG 75 ft (22 m)
14 AWG 120 ft (36 m)
*Blower and resistor are 4.5 watts each for a total circuit power of 9 watts.
(Continued on next page)
Pelco Manual C478M-L (11/03) 5
Page 6
Table A. Enclosure Accessory Wiring Distances (Continued)
Model Number Input Voltage Accessories Power Consumption Cable Size Cable Distance
EH3515-2 24 VAC Heater 25 watts 20 AWG 128 ft (39 m)
EH3515-3 230 VAC Heater 32 watts 20 AWG 21 ft (6 m)
EH3515-1HD 120 V AC Heater 23 watts 20 AWG 21 ft (6 m)
EH3515-2HD 24 V AC Heater 23 watts 20 AWG 108 ft (32 m)
EH3515-3HD 230 V AC Heater 23 watts 20 AWG 11 ft (3 m)
*Blower and resistor are 4.5 watts each for a total circuit power of 9 watts.
at 60 Hz Defroster 18 AWG 204 ft (62 m)
Blower 16 AWG 323 ft (98 m)
14 AWG 516 ft (157 m)
at 50 Hz Defroster 18 AWG 34 ft (10 m)
Blower* 16 AWG 55 ft (16 m)
14 AWG 88 ft (26 m)
at 60 Hz Defroster 18 AWG 66 ft (20 m)
16 AWG 54 ft (16 m) 14 AWG 87 ft (26 m)
at 60 Hz Defroster 18 AWG 172 ft (52 m)
16 AWG 274 ft (83 m) 14 AWG 437 ft (133 m)
at 50 Hz Defroster 18 AWG 18 ft (5 m)
16 AWG 28 ft (8 m) 14 AWG 45 ft (13 m)
Table B. 24 V AC Wiring Distances
The following are the recommended maximum distances for 24 VAC applications and are calculated with a 10-percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC-powered devices.)
Wire Gauge
20 AWG 18 AWG 16 AWG 14 AWG 12 AWG 10 AWG
(0.5mm2) (1.0mm2) (1.5mm2) (2.5mm2) (4.0mm2) (6.0mm2)
Total VA
10 283 451 716 1142 1811 2880
(86) (137) (218) (348) (551) (877)
20 141 225 358 571 905 1440
(42) (68) (109) (174) (275) (438)
30 94 150 238 380 603 960
(28) (45) (72) (115) (183) (292)
40 70 112 179 285 452 720
(21) (34) (54) (86) (137) (219)
50 56 90 143 228 362 576
(17) (27) (43) (69) (110) (175)
60 47 75 119 190 301 480
Total VA consumed
(14) (22) (36) (57) (91) (146)
70 40 64 102 163 258 411
(12) (19) (31) (49) (78) (125)
80 35 56 89 142 226 360
(10) (17) (27) (43) (68) (109)
90 31 50 79 126 201 320
(9) (15) (24) (38) (61) (97)
100 28 45 71 114 181 288
(8) (13) (21) (34) (55) (87)
Table C. Video Coaxial Cable Wiring Distances
Cable Type* Maximum Distance
RG59/U 750 ft (229 m) RG6/U 1,000 ft (305 m) RG11/U 1,500 ft (457 m)
* Minimum cable requirements:
75 ohms impedance All-copper center conductor All-copper braided shield with 95% braid coverage
Maximum distance from transformer to load
EXAMPLE:
An enclosure that requires 80 vA and is installed 35 feet (10 m) from the transformer would require a minimum wire gauge of 20 AWG.
NOTE:
Distances are calculated in feet; values in parenthe-
ses are meters.
6 Pelco Manual C478M-L (11/03)
Page 7
OPERATION
If your enclosure has a thermostatically controlled heater, the thermostat is set to turn on at 50°F (10°C) and to turn off at 80°F (27°C).
If your enclosure has a blower and/or defroster, they operate continuously.
MAINTENANCE
Regularly scheduled maintenance prolongs the operational life and appearance of the equipment. Clean the window regularly with a soft cloth using a mild, nonabrasive detergent and water to maintain picture clarity.
SERVICE MANUAL
If you need to repair the camera enclosure, obtain a service manual in one of the following ways:
Go to Pelco’s web site at
Call Pelco’s DataFax service at 1-800-289-9108 or 1-559-292-0435 and request docu­ment number 24788.
Contact Pelco’s Literature Department and request service manual C478SM.
SPECIFICATIONS
ftp://www.pelco.com
and find service manual C478SM.
Camera Mounting: Multiple holes on adjustable camera sled; camera sled mounts in
Camera and Lens Size Accommodates camera and lens combinations (including BNC con-
Viewing Window: Lexan®, .187-inch (4.75 mm) thick, optically clear, impact-resistant, Viewing Area
EH3508/EH3512/ EH3515: 2.25 in. H x 2.63 in. W (5.71 x 6.68 cm) All other models: 2.00-inch (5.08 cm) diameter circle
Cable Entry: Two PG13.5 compression glands on bottom at rear of enclosure; Cable Entry Holes: 0.875-inch diameter; will accept 0.50-inch (1.27 cm) conduit fitting Latch: Link-lock No. 3, stainless steel, can be secured with padlock (not
GENERAL
Construction: Extruded and die-cast aluminum body Dimensions: Refer to Figure 4 Environment: -10° to 120°F (-23° to 49°C) Weight EH3508: 2.67 lb (1.21 kg)
threaded strip for easier removal and can be inverted for additional camera elevation.
nector) up to 2.87 in. W x 3.00 in. H (7.28 x 7.62 cm) and the follow­ing lengths: EH3508: 6.80 in. (17.27 cm) EH3508-1/-2/-3: 5.00 in. (12.70 cm) EH3512: 10.25 in. (26.03 cm) EH3512-1/-2/-3: 9.00 in. (22.86 cm) EH3512-1HD/-2HD/-3HD: 10.00 in. (25.40 cm) EH3515: 13.25 in. (33.66 cm) EH3515-1/-2/-3: 12.00 in. (30.48 cm) EH3515-1HD/-2HD/-3HD: 13.00 in. (33.02 cm)
MR5 coated (U.L. 94HB rated).
maximum cable diameter 0.47-inch (1.19 cm). when compression gland is removed. supplied).
EH3508-1/-2/-3: 2.76 lb (1.25 kg) EH3512: 3.40 lb (1.58 kg) EH3512-1/-2/-3/-1HD/-2HD/-3HD: 3.85 lb (1.75 kg) EH3515: 4.10 lb (1.86 kg) EH3515-1/-2/-3/-1HD/-2HD/-3HD: 4.47 lb (2.03 kg)
(Design and product specifications subject to change without notice.)
Pelco Manual C478M-L (11/03) 7
Page 8
EH3508
A 14.75 (37.47) 17.75 (45.09)
10.75 (27.30)
B 12.75 (32.38) 15.75 (40.00)
8.75 (22.22)
C11.25 (28.57) 14.25 (36.20)
7.32 (18.59)
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES
Figure 4. EH3508, EH3512, EH3515 Dimension Drawing
WARRANTY AND RETURN INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Exceptions to this warranty are as noted below:
• Five years on Pelco manufactured cameras (CC3500/CC3600/CC3700 and MC3500/MC3600 Series); two years on all other cameras.
• Three years on Genex® Series (multiplexers, server, and keyboard) and 090 Series Camclosure Camera System.
•Two years on 100/150, 200 and 300 Series Camclosure® Camera Systems.
•Two years on cameras and all standard motorized or fixed focal length lenses.
•Two years on Legacy®, CM6700/CM6800/CM6800E/CM8500/CM9500/CM9740/CM9760 Matrix, DF5 and DF8 Series Fixed Dome products.
•Two years on Spectra®, Esprit®, and PS20 Scanners, including when used in continuous motion applications.
•Two years on Esprit and WW5700 series window wiper (excluding wiper blades).
• Eighteen months on DX Series digital video recorders.
• One year (except video heads) on video cassette recorders (VCRs). Video heads will be covered for a period of six months.
• Six months on all pan and tilts, scanners or preset lenses used in continuous motion applica­tions (that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products. Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have additional rights, which are subject to variation from state to state.
5.14
(13.05)
3.88
(9.86)
EH3512 EH3515
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to obtain a Repair Authorization number (RA), and provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
®
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions stated above, please include a written explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico:
Service Department Pelco 3500 Pelco Way Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico:
Intermediate Consignee Ultimate Consignee
American Overseas Air Freight Pelco 320 Beach Road 3500 Pelco Way Burlingame, CA 94010 Clovis, CA 93612-5699 USA USA
C
A
B
2.00
(5.08)
REVISION HISTORY
Manual # Date Comments
C478M-H 6/97 Rev H. Revised to include new models (EH3515, EH3515-1, EH3515-2, EH3515-3). C478M-I 8/98 Removed installation instructions for heater and blower kits, which have a separate manual. Moved exploded assembly
diagram and parts list to new service/maintenance manual. Added certifications.
C478M-J 6/99 Moved the EH3508 Series enclosures from manual C1435M-A. Updated the description, installation instructions, and
specifications. Updated wiring diagrams and dimension drawing. Modified per ECO 99-4749, which changed heater and defroster design.
C478M-K 7/99 Incorporated addendum of July 1, 1999. Added watts to model numbers. Added footnote to explain discrepancy of 230 VAC
blower wattage. Revised camera and lens dimensions for heater/defroster models.
C478M-L 11/03 Updated certifications and corrected lens size specification.