Pelco • 3500 Pelco Way, Clovis • CA 93612-5699 USA • Pelco Online @ http://www.pelco.com
In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 • DataFAX (800) 289-9108
International Customers: Tel (1-559) 292-1981 or FAX (1-559) 348-1120 • DataFAX (1-559) 292-0435
Page 2
IMPORTANT SAFEGUARDS AND WARNINGS
Prior to installation and use of this product, the following WARNINGS should be observed.
1.Installation and servicing should only be done by qualified service personnel and conform to all local codes.
2.Unless the unit is specifically marked as a NEMA Type 3, 3R, 3S, 4, 4X ,6 or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to
rain and moisture.
3.Only use replacement parts recommended by Pelco.
4.After replacement/repair of this unit’s electrical components, conduct a resistance
measurement between line and exposed parts to verify the exposed parts have not
been connected to line circuitry.
5.The installation method and materials should be capable to supporting four times the
weight of the enclosure, pan/tilt, camera and lens combination.
The product and/or manual may bear the following marks:
This symbol indicates that dangerous voltage
constituting a risk of electric shock is present
within this unit.
This symbol indicates that there are important operating and maintenance instructions
in the literature accompanying this unit.
Please thoroughly familiarize yourself with the information in this manual prior to installation
and operation.
CAUTION:
RISK OF ELECTRIC SHOCK.
DO NOT OPEN.
DESCRIPTION
The EH3508/EH3512/EH3515 Series are indoor/outdoor light-duty camera enclosures designed for use with various cameras on the market and accommodate fixed focal length or
motorized zoom lenses, with or without auto-iris operation.
The lid of the enclosure is hinged in the front providing easy access during installation and
when camera and lens adjustments are necessary. The camera sled also serves as an elevation block. Y ou can remove, flip, and then reinstall the sled to elevate the camera. All wiring and cabling is brought into the enclosure through adjustable glands at the bottom rear
of the enclosure.
The rear link-lock latch can be used with a padlock of suitable size for applications requiring
additional security.
MODELS
EH3508Enclosure, indoor/outdoor, 8.75-inch (22.23 cm) lower body length. (CE)
EH3508-1Same as EH3508 except unit is supplied with 120 VAC heater and defroster,
EH3508-2Same as EH3508 except unit is supplied with 24 VAC heater and defroster,
EH3508-3Same as EH3508 except unit is supplied with 230 VAC heater and defroster,
EH3512Enclosure, indoor/outdoor, 12.75-inch (32.38 cm) lower body length. (CE)
EH3512-1Same as EH3512 except unit is supplied with 120 VAC heater, defroster,
EH3512-1HD Same as EH3512 except unit is supplied with 120 VAC heater and defroster,
EH3512-2Same as EH3512 except unit is supplied with 24 VAC heater, defroster, and
EH3512-2HD Same as EH3512 except unit is supplied with 24 VAC heater and defroster,
EH3512-3Same as EH3512 except unit is supplied with 230 VAC heater, defroster,
EH3512-3HD Same as EH3512 except unit is supplied with 230VAC heater and defroster,
EH3515Enclosure, indoor/outdoor, 15.75-inch (40.00 cm) lower body length. (CE)
EH3515-1Same as EH3515 except unit is supplied with 120 VAC heater, defroster,
EH3515-1HD Same as EH3515 except unit is supplied with 120 VAC heater and defroster,
EH3515-2Same as EH3515 except unit is supplied with 24 VAC heater, defroster, and
EH3515-2HD Same as EH3515 except unit is supplied with 24 VAC heater and defroster,
EH3515-3Same as EH3515 except unit is supplied with 230 VAC heater, defroster,
EH3515-3HD Same as EH3515 except unit is supplied with 230 VAC heater and defroster,
INSTALLATION
The following items are supplied to mount the enclosure:
21/4-20 x .500-inch hex head screws
2Flat washers
2Split washers
The following items are supplied to mount the camera:
21/4-20 x .375-inch Phillips-head screws
and blower, 22 watts.
13 watts.
and blower, 27 watts.
23 watts.
blower, 25 watts. (CE)
23 watts. (CE)
and blower, 32 watts.
23 watts.
Perform the following steps to install the enclosure, camera, and lens:
1.Unlatch and open the lid.
2.Remove the camera sled from the rail.
a.Loosen the screws that hold the camera sled in place.
b.Slide the sled forward so it can be lifted out over the screws.
c.Remove the sled.
d.Remove the parts tied to the sled.
3.If you are wiring the enclosure with cable, remove the glands and nuts from the parts
bag and install them in the bottom of the enclosure. If you are wiring the enclosure
with conduit, do not install the glands.
4.Attach the enclosure body to the appropriate mount using the instructions provided
with the mount.
Attach the enclosure through the threaded mounting holes in the bottom of the enclosure. Use the 1/4-20 x .500 screws and washers provided (in the parts bag). Completely tighten the screws to attach the enclosure body to the mounting surface.
5.Attach the camera to the sled with the 1/4-20 x .375-inch Phillips-head screws provided (in the parts bag). You can attach the camera to either side of the sled. The side
of the sled to which you mount the camera depends on the type of camera and lens
you are attaching.
The edges of the sled are bent–one side up and the other side down. On one side of
the sled, the lip is wide; on the other side of the sled, the lip is narrow. In a typical installation, you mount the camera so that the holes in the wide lip of the sled fit over the
sled mounting screws.
However, you can elevate the sled if you are installing a camera with a low optical center line or a camera with a large diameter lens. To elevate the sled (and therefore elevate the camera), flip the sled over so that the holes in the narrow lip of the sled fit
over the sled mounting screws.
6.Move the sled so that the sled mounting screws extend through the narrow part of sled
mounting holes, and partially tighten the sled mounting screws.
Pelco Manual C478M-L (11/03)3
Page 4
7.Pull the video and power cables through the glands or conduit on the bottom of the enclosure. Refer to Tables A and B to determine the size of power wire to use. Refer to
Table C for the type of video coaxial cable to use.
8.Attach the cables to the camera.
9.If the enclosure has accessories that require power, connect the power to pins 1 and 2
on the PC Board (refer to Figures 1, 2, and 3 for information about accessory wiring).
Connect ground to pin 3 if required.
You can connect the camera power to the PC board if the voltages are the same between the accessories and camera. If you want to connect the camera power to the PC
board, connect the camera power to pins 1 and 2. Connect ground to pin 3 if required.
10. If the camera lens is adjustable, extend the lens to its maximum length; verify that the
camera is adjusted with the lens a minimum of 1/2 inch from the enclosure window.
11. Tighten the screws that secure the sled to the enclosure.
12. Adjust the glands for a tight fit around the cables.
13. Close the enclosure lid, and latch.
14. Adjust the camera focus and iris if necessary. If you need to adjust the focus and iris
manually, open the enclosure lid, adjust the focus and iris, and close the enclosure lid.
When using a single power source for both camera and accessories, consider the camera power
consumption when determining the wire gauge. T able A does not include camera power.
Table A. Enclosure Accessory Wiring Distances
The following cable sizes are the minimum recommended for use with the heater and defroster combination in enclosures in the
EH3508 Series, and the heater, defroster, and blower combination in enclosures in the EH3512 Series and EH3515 Series only.
Model NumberInput VoltageAccessoriesPower ConsumptionCable SizeCable Distance
EH3508-1120 VACHeater13 watts20 AWG5,456 ft (1,662 m)
EH3512-1HDat 60 HzDefroster18 AWG8,680 ft (2,645 m)
16 AWG13,777 ft (4,199 m)
14 AWG21,978 ft (6,698 m)
EH3508-224 VACHeater13 watts20 AWG218 ft(66 m)
EH3512-2HDat 60 HzDefroster18 AWG347 ft(105 m)
16 AWG551 ft(167 m)
14 AWG879 ft(267 m)
EH3508-3230 VACHeater13 watts20 AWG20,045 ft (6,109 m)
EH3512-3HDat 50 HzDefroster18 AWG31,890 ft (9,720 m)
16 AWG50,612 ft (15,426 m)
14 AWG80,738 ft (24,608 m)
EH3512-1120 VACHeater17 watts20 AWG4,172 ft (1,271 m)
at 60 HzDefroster18 AWG6,658 ft (2,023 m)
Blower16 AWG10,535 ft (3,211 m)
14 AWG16,806 ft (5,122 m)
EH3512-224 VACHeater15 watts20 AWG189 ft(57 m)
at 60 HzDefroster18 AWG300 ft(91 m)
Blower16 AWG477 ft(145 m)
14 AWG761 ft(231 m)
EH3512-3230 VACHeater22 watts20 AWG11,845 ft (3,610 m)
at 50 HzDefroster18 AWG18,844 ft (5,743 m)
Blower*16 AWG29,907 ft (9,115 m)
14 AWG47,709 ft (14,541 m)
EH3515-1120 VACHeater27 watts20 AWG29 ft(8 m)
at 60 HzDefroster18 AWG 47 ft(14 m)
Blower16 AWG75 ft(22 m)
14 AWG120 ft(36 m)
*Blower and resistor are 4.5 watts each for a total circuit power of 9 watts.
(Continued on next page)
Pelco Manual C478M-L (11/03)5
Page 6
Table A. Enclosure Accessory Wiring Distances (Continued)
Model NumberInput VoltageAccessoriesPower ConsumptionCable SizeCable Distance
EH3515-224 VACHeater25 watts20 AWG128 ft(39 m)
EH3515-3230 VACHeater32 watts20 AWG21 ft(6 m)
EH3515-1HD120 V ACHeater23 watts20 AWG21 ft(6 m)
EH3515-2HD24 V ACHeater23 watts20 AWG108 ft(32 m)
EH3515-3HD230 V ACHeater23 watts20 AWG11 ft(3 m)
*Blower and resistor are 4.5 watts each for a total circuit power of 9 watts.
at 60 HzDefroster18 AWG204 ft(62 m)
Blower16 AWG323 ft(98 m)
14 AWG516 ft(157 m)
at 50 HzDefroster18 AWG34 ft(10 m)
Blower*16 AWG55 ft(16 m)
14 AWG88 ft(26 m)
at 60 HzDefroster18 AWG66 ft(20 m)
16 AWG54 ft (16 m)
14 AWG87 ft(26 m)
at 60 HzDefroster18 AWG172 ft(52 m)
16 AWG274 ft (83 m)
14 AWG437 ft(133 m)
at 50 HzDefroster18 AWG18 ft(5 m)
16 AWG28 ft(8 m)
14 AWG45 ft(13 m)
Table B. 24 V AC Wiring Distances
The following are the recommended maximum distances for 24
VAC applications and are calculated with a 10-percent voltage
drop. (Ten percent is generally the maximum allowable voltage
drop for AC-powered devices.)
RG59/U750 ft (229 m)
RG6/U1,000 ft (305 m)
RG11/U1,500 ft (457 m)
* Minimum cable requirements:
75 ohms impedance
All-copper center conductor
All-copper braided shield with 95% braid coverage
Maximum distance from transformer to load
EXAMPLE:
An enclosure that requires 80 vA and is
installed 35 feet (10 m) from the transformer would require a
minimum wire gauge of 20 AWG.
NOTE:
Distances are calculated in feet; values in parenthe-
ses are meters.
6Pelco Manual C478M-L (11/03)
Page 7
OPERATION
If your enclosure has a thermostatically controlled heater, the thermostat is set to turn on at
50°F (10°C) and to turn off at 80°F (27°C).
If your enclosure has a blower and/or defroster, they operate continuously.
MAINTENANCE
Regularly scheduled maintenance prolongs the operational life and appearance of the
equipment. Clean the window regularly with a soft cloth using a mild, nonabrasive detergent
and water to maintain picture clarity.
SERVICE MANUAL
If you need to repair the camera enclosure, obtain a service manual in one of the following
ways:
•Go to Pelco’s web site at
•Call Pelco’s DataFax service at 1-800-289-9108 or 1-559-292-0435 and request document number 24788.
•Contact Pelco’s Literature Department and request service manual C478SM.
SPECIFICATIONS
ftp://www.pelco.com
and find service manual C478SM.
Camera Mounting:Multiple holes on adjustable camera sled; camera sled mounts in
Camera and
Lens SizeAccommodates camera and lens combinations (including BNC con-
EH3508/EH3512/
EH3515:2.25 in. H x 2.63 in. W (5.71 x 6.68 cm)
All other models:2.00-inch (5.08 cm) diameter circle
Cable Entry:Two PG13.5 compression glands on bottom at rear of enclosure;
Cable Entry Holes:0.875-inch diameter; will accept 0.50-inch (1.27 cm) conduit fitting
Latch:Link-lock No. 3, stainless steel, can be secured with padlock (not
GENERAL
Construction:Extruded and die-cast aluminum body
Dimensions:Refer to Figure 4
Environment:-10° to 120°F (-23° to 49°C)
WeightEH3508:2.67 lb (1.21 kg)
threaded strip for easier removal and can be inverted for additional
camera elevation.
nector) up to 2.87 in. W x 3.00 in. H (7.28 x 7.62 cm) and the following lengths:
EH3508:6.80 in. (17.27 cm)
EH3508-1/-2/-3:5.00 in. (12.70 cm)
EH3512:10.25 in. (26.03 cm)
EH3512-1/-2/-3:9.00 in. (22.86 cm)
EH3512-1HD/-2HD/-3HD:10.00 in. (25.40 cm)
EH3515:13.25 in. (33.66 cm)
EH3515-1/-2/-3:12.00 in. (30.48 cm)
EH3515-1HD/-2HD/-3HD:13.00 in. (33.02 cm)
MR5 coated (U.L. 94HB rated).
maximum cable diameter 0.47-inch (1.19 cm).
when compression gland is removed.
supplied).
EH3508-1/-2/-3:2.76 lb (1.25 kg)
EH3512:3.40 lb (1.58 kg)
EH3512-1/-2/-3/-1HD/-2HD/-3HD: 3.85 lb (1.75 kg)
EH3515:4.10 lb (1.86 kg)
EH3515-1/-2/-3/-1HD/-2HD/-3HD: 4.47 lb (2.03 kg)
(Design and product specifications subject to change without notice.)
Pelco Manual C478M-L (11/03)7
Page 8
EH3508
A14.75 (37.47)17.75 (45.09)
10.75 (27.30)
B12.75 (32.38)15.75 (40.00)
8.75 (22.22)
C11.25 (28.57)14.25 (36.20)
7.32 (18.59)
NOTE: VALUES IN PARENTHESES ARE CENTIMETERS; ALL OTHERS ARE INCHES
Pelco will repair or replace, without charge, any merchandise proved defective in material or
workmanship for a period of one year after the date of shipment. Exceptions to this warranty are
as noted below:
• Five years on Pelco manufactured cameras (CC3500/CC3600/CC3700 and MC3500/MC3600
Series); two years on all other cameras.
• Three years on Genex® Series (multiplexers, server, and keyboard) and 090 Series Camclosure
Camera System.
•Two years on 100/150, 200 and 300 Series Camclosure® Camera Systems.
•Two years on cameras and all standard motorized or fixed focal length lenses.
•Two years on Legacy®, CM6700/CM6800/CM6800E/CM8500/CM9500/CM9740/CM9760
Matrix, DF5 and DF8 Series Fixed Dome products.
•Two years on Spectra®, Esprit®, and PS20 Scanners, including when used in continuous
motion applications.
•Two years on Esprit and WW5700 series window wiper (excluding wiper blades).
• Eighteen months on DX Series digital video recorders.
• One year (except video heads) on video cassette recorders (VCRs). Video heads will be
covered for a period of six months.
• Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco
shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis,
California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident
are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the
specific use or application made of the Products. Pelco’s liability for any claim, whether based on
breach of contract, negligence, infringement of any rights of any party or product liability, relating
to the Products shall not exceed the price paid by the Dealer to Pelco for such Products. In no
event will Pelco be liable for any special, incidental or consequential damages (including loss of
use, loss of profit and claims of third parties) however caused, whether by the negligence of
Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The Dealer may also have
additional rights, which are subject to variation from state to state.
5.14
(13.05)
3.88
(9.86)
EH3512EH3515
If a warranty repair is required, the Dealer must contact Pelco at (800) 289-9100 or (559) 292-1981 to
obtain a Repair Authorization number (RA), and provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice number
®
3. Details of the defect or problem
If there is a dispute regarding the warranty of a product which does not fall under the warranty conditions
stated above, please include a written explanation with the product when returned.
Method of return shipment shall be the same or equal to the method by which the item was received by
Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100
or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if
returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and
freight should be prepaid. Ship to the appropriate address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto Rico:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto Rico:
Intermediate ConsigneeUltimate Consignee
American Overseas Air FreightPelco
320 Beach Road3500 Pelco Way
Burlingame, CA 94010Clovis, CA 93612-5699
USAUSA
C
A
B
2.00
(5.08)
REVISION HISTORY
Manual #DateComments
C478M-H6/97Rev H. Revised to include new models (EH3515, EH3515-1, EH3515-2, EH3515-3).
C478M-I8/98Removed installation instructions for heater and blower kits, which have a separate manual. Moved exploded assembly
diagram and parts list to new service/maintenance manual. Added certifications.
C478M-J6/99Moved the EH3508 Series enclosures from manual C1435M-A. Updated the description, installation instructions, and
specifications. Updated wiring diagrams and dimension drawing. Modified per ECO 99-4749, which changed heater and
defroster design.
C478M-K7/99Incorporated addendum of July 1, 1999. Added watts to model numbers. Added footnote to explain discrepancy of 230 VAC
blower wattage. Revised camera and lens dimensions for heater/defroster models.
C478M-L11/03Updated certifications and corrected lens size specification.